Loading...
HomeMy WebLinkAboutE100.01. ALL LOADING/WIRE SIZING & DESIGN TO BE DETERMINED & INSTALLED BY A LICENSED ELECTRICAL CONTRACTOR PER LOCAL & NATIONAL CODES, RULES & ORDINANCES.\P\P2. ALL WIRE TO BE COPPER, UNLESS SPECIFIED OTHERWISE.\P\P3. CONDUIT ROUTING AND DEVICE/ EQUIPMENT LOCATIONS SHOWN ARE DIAGRAMMATIC ONLY, CONTRACTOR SHALL FIELD ROUTE AND LOCATE AS REQUIRED.\P\P4. COORDINATE LOCATIONS OF ELECTRICAL FIXTURES, DEVICES, OUTLETS, ETC. WITH ARCHITECTURAL PLANS PRIOR TO ROUGH-IN WORK.\P\P5. CONTRACTOR SHALL COORDINATE ALL WORK WITH OHTER TRADES PRIOR TO INSTALLATION; REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR EXACT LOCATION AND SIZE OF EQUIPMENT WHICH ARE PROVIDED BY OTHERS AND CONNECTED BY ELECTRICIAN.\P\P6. VERIFY ALL DOOR SWINGS WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGHING IN FOR LIGHT SWITCHES. Electrical Schedule TableSymbolTypeAdditional NotesS C CH PC1420R V 220VAFCI AFCIGDOGFIPHTVWP/GFISDISPS4S 3S CW DETECTOR - SMOKE DETECTOR - SMOKE/CARBON MONOXIDE COMBINATION DISCONNECT - SWITCHEDEQUIPMENT - CHIMES - DOORBELL FAN - CEILING W/ LIGHTFAN - EXHAUSTFAN - EXHAUST W/ LIGHTFAN - EXHAUST W/ LIGHT-VENT TO EXTERIORGAS TAPLIGHT - CEILINGLIGHT - CEILING MOUNTED HANGING FIXTURELIGHT - CEILING-PULL CHAINLIGHT - FLUORESCENT-UNDER CAB-14LIGHT - FLUORESCENT-UNDER CAB-20LIGHT - RECESSEDLIGHT - RECESSED-EYEBALLLIGHT - RECESSED-VAPOR PROOFLIGHT - WALLLIGHT-WALL-4 BULBOUTLET - 220VOUTLET - AFCIOUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - DUPLEX-SPLIT WIRED - AFCIOUTLET - GARAGE DOOROUTLET - GFIOUTLET - PHONEOUTLET - TVOUTLET - WATERPROOF-GFISWITCH - DISPOSALSWITCH - FOUR WAYSWITCH - LIGHTSWITCH - PUSH BUTTONSWITCH - THREE WAY WATER STUB FOR ICE MAKER THE SMOKE DETECTORS SHALL BE AC POWERED AND HAVE BATTERY BACKUP. THE INSTALLATION SHALL ALSO MEET NFPA 72-07. A CARBON MONOXIDE ALARM IS REQUIRED OUTSIDE OF SLEEPING AREAS ON EACH FLOOR FAN BOX PER NEC. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL) CAT 5ERG-6 50 CFM MIN INTERMITTENT FAN TO EXTERIOR50 CFM MIN INTERMITTENT FAN TO EXTERIOR50 CFM MIN INTERMITTENT FAN TO EXTERIOR THERMOSTAT THERMOSTAT SHALL BE PROGRAMMABLE T CASUAL LIVINGOFFICE WIC FOYER RETREAT PWDR. GATHERING NOOK WIC O. SUITE PORCH 2 CAR GARAGE O. BATH LIN DINING KITCHEN 1 CAR GARAGE LAUN PANTRY FIRST FLOOR ELECTRICAL PLAN1/4" = 1'-0" GFI FAN, VENT \PTO EXT.SS RWP LIGHT/FAN, VENT TO EXT.S S GFI GFI FAN, VENT \PTO EXT. S S S GDO STO BELOW WP/GFIS S 3S 3S GFI DED.GFI 220V GFI GFI GFI TO LIGHT ABOVE R3STO ABOVES4 R RR RR R 3S R R R R R R 3S 3S3S3SS4 SS S3S SSS S S PC GFI 3S S 3SRR 3S 3S R GDO PC DED. 3S S GFIGFI GFI GFI DED.220V DED. S S 3S TO LIGHT ABOVE GFISSRS PLOTTED: June 11, 2018 / Rudolph Sanchez / PLAN-4634-IN-WCLY-MEPP.DWG F i r s t F l o o r E l e c t r i c a l P l a n 6.10 PLAN NAME SHEET COMMUNITY NAME PRODUCTION MANAGER LAWSON COMMUNITY ID RELEASE DATE:DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN IDLEGACY PLAN NUMBER / NAME SPECIFICATION LEVEL GARAGE HANDING REV # PROJECT TYPE CURRENT NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS ARCHITECT OF RECORD:ENGINEER OF RECORD: 05/11/2018Joel Hampshire (c) Copyright PulteGroup, Inc. - 2012 I n d i a n a D i v i s i o n 1 1 5 9 0 N . M e r i d i a n S t , S u i t e 5 3 0 C a r m e l , I n d i a n a 4 6 0 3 2 SINGLE FAMILY WestClay ---- GARAGE RIGHT Red Plan 2 1816.0000 LOT 319 4634 SCHWARZ ENGINEERINGGODUCO DESIGN - ARCHITECTS 07/11/18 William Hohlt