HomeMy WebLinkAboutE200.01. ALL LOADING/WIRE SIZING & DESIGN TO BE DETERMINED & INSTALLED BY A LICENSED ELECTRICAL CONTRACTOR PER LOCAL & NATIONAL CODES, RULES & ORDINANCES.\P\P2. ALL WIRE TO BE COPPER, UNLESS SPECIFIED OTHERWISE.\P\P3. CONDUIT ROUTING AND DEVICE/ EQUIPMENT LOCATIONS SHOWN ARE DIAGRAMMATIC ONLY, CONTRACTOR SHALL FIELD ROUTE AND LOCATE AS REQUIRED.\P\P4. COORDINATE LOCATIONS OF ELECTRICAL FIXTURES, DEVICES, OUTLETS, ETC. WITH ARCHITECTURAL PLANS PRIOR TO ROUGH-IN WORK.\P\P5. CONTRACTOR SHALL COORDINATE ALL WORK WITH OHTER TRADES PRIOR TO INSTALLATION; REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR EXACT LOCATION AND SIZE OF EQUIPMENT WHICH ARE PROVIDED BY OTHERS AND CONNECTED BY ELECTRICIAN.\P\P6. VERIFY ALL DOOR SWINGS WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGHING IN FOR LIGHT SWITCHES.
Electrical Schedule TableSymbolTypeAdditional NotesS
C
CH
PC1420R
V
220VAFCI
AFCIGDOGFIPHTVWP/GFISDISPS4S
3S
CW
DETECTOR - SMOKE
DETECTOR - SMOKE/CARBON MONOXIDE COMBINATION
DISCONNECT - SWITCHEDEQUIPMENT - CHIMES - DOORBELL
FAN - CEILING W/ LIGHTFAN - EXHAUSTFAN - EXHAUST W/ LIGHTFAN - EXHAUST W/ LIGHT-VENT TO EXTERIORGAS TAPLIGHT - CEILINGLIGHT - CEILING MOUNTED HANGING FIXTURELIGHT - CEILING-PULL CHAINLIGHT - FLUORESCENT-UNDER CAB-14LIGHT - FLUORESCENT-UNDER CAB-20LIGHT - RECESSEDLIGHT - RECESSED-EYEBALLLIGHT - RECESSED-VAPOR PROOFLIGHT - WALLLIGHT-WALL-4 BULBOUTLET - 220VOUTLET - AFCIOUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - DUPLEX-SPLIT WIRED - AFCIOUTLET - GARAGE DOOROUTLET - GFIOUTLET - PHONEOUTLET - TVOUTLET - WATERPROOF-GFISWITCH - DISPOSALSWITCH - FOUR WAYSWITCH - LIGHTSWITCH - PUSH BUTTONSWITCH - THREE WAY
WATER STUB FOR ICE MAKER
THE SMOKE DETECTORS SHALL BE AC POWERED AND HAVE BATTERY BACKUP. THE INSTALLATION SHALL ALSO MEET NFPA 72-07.
A CARBON MONOXIDE ALARM IS REQUIRED OUTSIDE OF SLEEPING AREAS ON EACH FLOOR
FAN BOX PER NEC. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL)
CAT 5ERG-6
50 CFM MIN INTERMITTENT FAN TO EXTERIOR50 CFM MIN INTERMITTENT FAN TO EXTERIOR50 CFM MIN INTERMITTENT FAN TO EXTERIOR
THERMOSTAT THERMOSTAT SHALL BE PROGRAMMABLE T
GAME ROOMBEDROOM 2
BEDROOM 3 PRINCESS SUITE
LOFT
WIC
WIC
WIC
BATH 3
BATH 2
OPEN TO BELOW
OPEN TO BELOW
LIN
LIN
SECOND FLOOR ELECTRICAL PLAN1/4" = 1'-0"
SSSS
SGFI
GFI
S
S
S
3S
3S S
SSS
3SPC
S S
S4
S4 TO BELOW
SLIGHT/FAN, \PVENT TO EXT.
SR
R
R
R R
LIGHT/FAN, \PVENT TO EXT.
3S3S
TO BELOW
LIGHT/FAN, \PVENT TO EXT.
PLOTTED: May 15, 2018 / Rudolph Sanchez / PLAN-4634-IN-WCLY-MEPP.DWG
S e c o n d F l o o r E l e c t r i c a l P l a n
6.11
PLAN NAME
SHEET
COMMUNITY NAME
PRODUCTION MANAGER
LAWSON COMMUNITY ID
RELEASE DATE:DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN IDLEGACY PLAN NUMBER / NAME
SPECIFICATION LEVEL
GARAGE HANDING
REV #
PROJECT TYPE
CURRENT
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
ARCHITECT OF RECORD:ENGINEER OF RECORD:
05/11/2018Joel Hampshire
(c) Copyright PulteGroup, Inc. - 2012
I n d i a n a D i v i s i o n
1 1 5 9 0 N . M
e r i d i a n S t , S u i t e 5 3 0
C
a
r m e l , I n
d
i a
n
a
4
6
0
3
2
SINGLE FAMILY
WestClay
----
GARAGE RIGHT
Red
Plan 2
1816.0000
LOT 319
4634
SCHWARZ ENGINEERINGGODUCO DESIGN - ARCHITECTS
07/11/18
William Hohlt