HomeMy WebLinkAboutA012.02 1/4 : 12
5 : 12
2 1/4 : 12
ROOF NOTES:ROOF FRAMING NOTES:
-FURNISH & INSTALL NEW DOUBLE 1-3/4"W X 16"H LVL RIDGE BEAM
AS SHOWN IN PLANS.
-FURNISH & INSTALL NEW 2X8" SYP RAFTERS @ 16" O/C AS SHOWN
ON PLANS. NEW RAFTERS TO BE ATTACHED TO TOP PLATES WITH
SIMPSON STRONG-TIE (OR EQUIV.) RAFTER STRAPS AS SHOWN ON
DETAILS.
-FURNISH & INSTALL NEW 2X6 LOOKOUT RAFTERS @ 24" O/C AS
SHOWN ON PLANS AND DETAILS.
-FURNISH & INSTALL NEW 2X6 SUBFASCIA AS SHOWN ON PLANS
AND DETAILS..
-FURNISH & INSTALL NEW 7/16" OSB ROOF DECKING OVER RAFTERS.
-FURNISH & INSTALL NEW 2X6 RAFTERS FROM EXISTING LOWER
SHED ROOF PLANE TO TOP OF NEW DECKING.
NOTES:ROOF CONSTRUCTION NOTES:
-FURNISH & INSTALL NEW ICE & WATER SHIELD ON LOWER LEVEL ROOF SURFACES
AS SHOWN.
-FURNISH & INSTALL NEW FLASHING ALONG WALLS.
-FURNISH & INSTALL NEW METAL DRIP EDGE ALONG RAKES AND GUTTER APRON
ALONG EAVES.
-FURNISH & INSTALL NEW METAL IN VALLEY TO MATCH NEW STANDING SEAM ROOF.
-FURNISH & INSTALL NEW STANDING SEAM METAL ROOF WITH HIDDEN FASTENERS
& CLIPS ON EXISTING LOWER LEVEL ROOF AND NEW LOWER LEVEL ROOF AS
SHOWN.
-FURNISH & INSTALL NEW METAL RIDGE CAP TO MATCH NEW STANDING SEAM
ROOF.
-FURNISH & INSTALL 6" GUTTERS AND 4"X3" DOWNSPOUTS ALONG ALL EAVES OF
NEW METAL ROOF AREAS. PROFILE & COLOR OF GUTTERS TO MATCH EXISTING.
DOWNSPOUTS TO DRAIN ONTO FINISH GRADE TO MATCH EXISTING.
#1
of
12
Date:
04.24.18
Sheet:
Revision:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been
prepared by Case Design &
Remodeling solely for its use and
should not be reproduced or relied
upon by any other parties.
Dimensions shown or scaled are
subject to change per actual job
condition and must be verified.
Materials are to be supplied as
specified as equal or standard
when not uniquely specified.
Installed materials may vary in
appearance from drawings.
Reference manufacturer's product
data for actual appearance and
specifications.
An
d
e
r
s
o
n
Re
s
i
d
e
n
c
e
Th
r
e
e
-
S
e
a
s
o
n
s
Ro
o
m
Ad
d
i
t
i
o
n
& Ou
t
d
o
o
r
Li
v
i
n
g
Ar
v
i
e
& Ke
l
l
y
An
d
e
r
s
o
n
60
1
7
Ta
n
a
n
a
Dr
.
Ca
r
m
e
l
,
In
d
i
a
n
a
46
0
3
3
Approved By:
Date:
5
FINAL
Craig Dice
Designer
cdice@caseindy.com
Dave Null
Lead Designer
dnull@caseindy.com
PROPOSED ROOF FRAMING & ROOF PLAN
SCALE: 3/16" = 1'
#2 06.20.18
07/12/18
Mike Sheeks