Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
truss
Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Timberland Home Center-Brazil, IN. Liu, Xuegang Pages or sheets covered by this seal: I30503586 thru I30503620 My license renewal date for the state of Indiana is July 31, 2018. 1700581 Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. IMPORTANT NOTE: EATON B 16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. July 20,2017 Job 1700581 Truss A Truss Type COMMON Qty 10 Ply 1 EATON B Job Reference (optional) I30503586 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:43:53 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-AZupOltMCkGNiYjQkBHceQbL2chwLn2NZT_hEZywVGa Scale = 1:63.1 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 3x8 4x6 3x8 5x6 3x6 3x8 3x6 2x4 3x6 2x4 5x6 3x6 8-1-0 8-1-0 16-0-0 7-11-0 23-11-0 7-11-0 32-0-0 8-1-0 -0-11-4 0-11-4 8-1-0 8-1-0 16-0-0 7-11-0 23-11-0 7-11-0 32-0-0 8-1-0 32-11-4 0-11-4 0- 6 - 6 9- 1 0 - 6 0- 6 - 6 7.00 12 Plate Offsets (X,Y)-- [2:0-1-0,0-0-9], [2:0-6-0,0-1-3], [8:0-1-0,0-0-9], [8:0-6-0,0-1-3] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.91 0.70 0.31 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.36 0.11 (loc) 2-14 2-14 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 124 lb FT = 0% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S 1650F 1.6E *Except* 1-4,6-9: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 7-10,3-14: 2x4 SPF Stud/No.3 WEDGE Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-12, 3-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=1333/0-3-8, 8=1333/0-3-8 Max Uplift 2=-106(LC 6), 8=-106(LC 6) Max Grav 2=1430(LC 12), 8=1430(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2203/143, 3-5=-1537/179, 5-7=-1537/179, 7-8=-2203/143 BOT CHORD 2-14=-20/1763, 12-14=-20/1763, 10-12=-20/1763, 8-10=-20/1763 WEBS 5-12=-44/967, 7-12=-780/132, 7-10=0/351, 3-12=-780/132, 3-14=0/351 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=106, 8=106. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss A1 Truss Type COMMON Qty 9 Ply 1 EATON B Job Reference (optional) I30503587 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:43:54 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-emSBb5u_z2ODJiHcIuorBe7WE01B4EJWo7jEm0ywVGZ Scale = 1:62.4 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 3x8 4x6 3x8 5x6 3x6 3x8 3x6 2x4 3x6 2x4 3x6 3x4 3x4 3x6 8-1-0 8-1-0 16-0-0 7-11-0 23-11-0 7-11-0 31-8-8 7-9-8 -0-11-4 0-11-4 8-1-0 8-1-0 16-0-0 7-11-0 23-11-0 7-11-0 31-8-8 7-9-8 0- 6 - 6 9- 1 0 - 6 0- 8 - 7 7.00 12 Plate Offsets (X,Y)-- [2:0-1-0,0-0-9], [2:0-6-0,0-1-3], [9:Edge,0-0-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.94 0.70 0.31 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.36 0.10 (loc) 2-14 2-14 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 127 lb FT = 0% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-6,6-9: 2x4 SPF-S 1650F 1.6E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 7-10,3-14: 2x4 SPF Stud/No.3 WEDGE Left: 2x4 SPF Stud/No.3 SLIDER Right 2x4 SPF Stud/No.3 4-4-11 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-12, 3-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=1329/0-3-8, 9=1261/0-3-8 Max Horz 2=14(LC 6) Max Uplift 2=-107(LC 6), 9=-71(LC 6) Max Grav 2=1424(LC 12), 9=1385(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2192/143, 3-5=-1528/180, 5-7=-1521/180, 7-9=-2126/144 BOT CHORD 2-14=-35/1750, 12-14=-35/1750, 10-12=-34/1700, 9-10=-34/1700 WEBS 5-12=-44/940, 7-12=-719/131, 7-10=0/334, 3-12=-777/132, 3-14=0/350 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9 except (jt=lb) 2=107. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss AG Truss Type GABLE Qty 1 Ply 1 EATON B Job Reference (optional) I30503588 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:43:55 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-6y0ZpRvckLW4xssosbJ4jrguEQXgpjpf1nTnISywVGY Scale: 3/16"=1' Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 51 52 3x6 4x6 3x6 3x4 3x8 3x6 3x4 3x8 3x6 32-0-0 32-0-0 -0-11-4 0-11-4 16-0-0 16-0-0 32-0-0 16-0-0 32-11-4 0-11-4 0- 6 - 6 9- 1 0 - 6 0- 6 - 6 7.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-15], [2:0-2-5,Edge], [26:0-0-0,0-0-15], [26:0-2-5,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.10 0.05 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 27 27 26 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 208 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 *Except* 14-39,13-40,15-38: 2x4 SPF No.2 WEDGE Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 14-39, 13-40, 15-38 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 32-0-0. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 39, 42, 43, 44, 45, 46, 47, 48, 49, 50, 36, 35, 34, 33, 32, 31, 30, 29, 28 Max Grav All reactions 250 lb or less at joint(s) 2, 39, 40, 42, 43, 44, 45, 46, 47, 48, 49, 50, 38, 36, 35, 34, 33, 32, 31, 30, 29, 28, 26 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 39, 42, 43, 44, 45, 46, 47, 48, 49, 50, 36, 35, 34, 33, 32, 31, 30, 29, 28. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss AG1 Truss Type GABLE Qty 1 Ply 1 EATON B Job Reference (optional) I30503589 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:43:56 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-b8ax0nwFVfexZ0R?PJrJG3CuVpikY8qpGRCLquywVGX Scale = 1:63.1 Sheet Back Right Option 2-9-11 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 38 39 11 3x8 4x6 3x8 5x6 3x6 3x8 3x6 3x6 3x10 3x4 3x4 3x6 1-1 0 - 8 8-1-0 8-1-0 16-0-0 7-11-0 23-11-0 7-11-0 29-2-5 5-3-5 30-0-0 0-9-11 32-0-0 2-0-0 -0-11-4 0-11-4 8-1-0 8-1-0 14-1-11 6-0-11 16-0-0 1-10-5 23-11-0 7-11-0 32-0-0 8-1-0 32-11-4 0-11-4 0- 6 - 6 9- 1 0 - 6 0- 6 - 6 7.00 12 Plate Offsets (X,Y)-- [2:0-1-0,0-0-9], [2:0-6-0,0-1-3], [9:0-1-4,0-1-8] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.83 0.76 0.31 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.36 0.10 (loc) 2-16 2-16 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 166 lb FT = 0% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP 2400F 2.0E *Except* 1-4,6-10: 2x4 SPF-S 1650F 1.6E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 7-12,3-16: 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 WEDGE Left: 2x4 SPF Stud/No.3 SLIDER Right 2x4 SPF Stud/No.3 4-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-14, 3-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=1326/0-3-8, 9=1146/2-3-8, 11=197/0-3-8 Max Uplift 2=-108(LC 6), 9=-118(LC 6) Max Grav 2=1422(LC 12), 9=1223(LC 12), 11=227(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2183/145, 3-5=-1525/182, 5-7=-1518/182, 7-9=-2114/152 BOT CHORD 2-16=-22/1747, 14-16=-22/1747, 12-14=-26/1682, 11-12=-26/1682, 9-11=-26/1682 WEBS 5-14=-45/937, 7-14=-695/137, 7-12=0/277, 3-14=-771/131, 3-16=0/345 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=108, 9=118. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss AT Truss Type Roof Special Qty 6 Ply 1 EATON B Job Reference (optional) I30503590 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:43:57 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XeYQfm2PxzqYJJ2FDiRGXBznUVV-3L8KE7wtGzmoA90Bz0MYpGl01D0pHV?yU5yuNKywVGW Scale = 1:69.5 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 18 196x12 MT18HS 6x12 MT18HS 3x8 4x9 2x4 3x6 2x4 6x10 5x6 10x20 MT18HS 3x6 2x4 5x6 3x6 5x6 2-3-8 2-3-8 3-3-8 1-0-0 8-5-6 5-1-14 15-0-0 6-6-10 16-0-0 1-0-0 23-11-0 7-11-0 32-0-0 8-1-0 2-3-8 2-3-8 8-5-6 6-1-14 16-0-0 7-6-10 23-11-0 7-11-0 32-0-0 8-1-0 32-11-4 0-11-4 0- 6 - 6 9- 1 0 - 6 0- 6 - 6 1- 6 - 0 0- 6 - 0 0- 6 - 0 7.00 12 12.00 12 Plate Offsets (X,Y)-- [3:0-1-0,0-2-8], [3:0-1-12,0-1-12], [3:0-3-6,0-0-14], [4:0-4-12,0-3-0], [8:0-1-0,0-0-9], [8:0-6-0,0-1-3], [12:0-1-4,0-1-4], [12:0-11-12,Edge], [17:0-1-8,0-1-12] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.97 0.83 0.70 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.27 -0.68 0.52 (loc) 3-15 3-15 8 l/defl >999 >557 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 158 lb FT = 0% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-4: 2x8 SP 2250F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 *Except* 7-13: 2x4 SPF No.2 WEDGE Right: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. Except: 1 Row at midpt 5-13 WEBS 1 Row at midpt 4-14, 7-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=1242/0-3-8, 8=1322/0-3-8 Max Horz 1=-14(LC 6) Max Uplift 1=-79(LC 6), 8=-107(LC 6) Max Grav 1=1365(LC 12), 8=1417(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-957/83, 2-3=-363/72, 3-4=-2705/161, 4-5=-1832/172, 5-7=-1567/182, 7-8=-2180/142 BOT CHORD 3-15=-36/2449, 14-15=-32/2456, 13-14=0/1547, 5-13=-593/0, 10-12=0/326, 8-10=-20/1745 WEBS 4-15=0/310, 4-14=-1248/148, 5-14=0/1684, 10-13=-46/1422, 7-13=-714/127, 7-10=0/307 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=107. 9) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss B Truss Type SPECIAL Qty 7 Ply 1 EATON B Job Reference (optional) I30503591 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:43:58 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-XXiiRSxV1GvfoJbNXktnLUID?dLs0z46jlhSvnywVGV Scale = 1:61.5 1 2 3 4 5 6 7 8 9 1014131211 15 16 3x6 4x6 3x6 5x6 3x6 6x12 3x10 6x8 3x4 2x4 3x4 5x6 2x4 8-10-7 8-10-7 17-6-15 8-8-7 26-3-6 8-8-7 30-0-0 3-8-10 -0-11-4 0-11-4 7-1-14 7-1-14 14-1-11 6-11-14 20-10-1 6-8-5 26-3-6 5-5-5 30-0-0 3-8-10 30-11-4 0-11-4 0- 6 - 6 8- 9 - 6 9- 9 - 6 0- 6 - 6 1- 0 - 0 7.00 12 3.50 12 Plate Offsets (X,Y)-- [2:0-1-0,0-0-9], [2:0-6-0,0-1-3], [9:0-0-9,0-0-2], [9:0-10-0,0-0-5], [9:0-2-15,1-5-5], [9:0-0-3,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.89 0.85 0.58 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.21 -0.65 0.20 (loc) 11-12 11-12 9 l/defl >999 >548 n/a L/d 240 180 n/a PLATES MT20 Weight: 122 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 *Except* 5-14,5-12: 2x4 SPF No.2 WEDGE Left: 2x4 SPF Stud/No.3, Right: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=1253/0-3-8, 9=1253/0-3-8 Max Horz 2=-28(LC 6) Max Uplift 2=-101(LC 6), 9=-103(LC 6) Max Grav 2=1342(LC 12), 9=1343(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2025/143, 3-5=-1931/213, 5-7=-1833/184, 7-8=-3499/232, 8-9=-3621/135 BOT CHORD 2-14=-1/1621, 12-14=0/1062, 11-12=-9/1794, 9-11=-60/3067 WEBS 3-14=-458/174, 5-14=-65/731, 5-12=-24/820, 7-12=-710/166, 7-11=-72/1491 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=101, 9=103. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss BG Truss Type GABLE Qty 1 Ply 1 EATON B Job Reference (optional) I30503592 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:43:59 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-?jF4foy7oa1WQTAa5RO0uhqWV1s2lXzFyPR?RDywVGU Scale: 3/16"=1' Sheet Back Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 43 3x6 4x6 3x6 3x4 3x8 3x6 3x6 3x4 3x8 26-3-6 26-3-6 30-0-0 3-8-10 -0-11-4 0-11-4 14-1-11 14-1-11 30-0-0 15-10-5 30-11-4 0-11-4 0- 6 - 6 9- 9 - 6 1- 0 - 0 0- 6 - 6 1- 0 - 0 7.00 12 3.50 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-15], [2:0-2-5,Edge], [22:0-0-14,0-1-8], [22:0-2-15,0-9-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.33 0.15 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 0.03 0.00 (loc) 23 23 22 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 175 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 *Except* 12-33: 2x4 SPF No.2 WEDGE Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 12-33 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 30-0-0. (lb) - Max Horz 2=-27(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 2, 22, 33, 36, 37, 38, 39, 40, 41, 42, 31, 30, 29, 28, 27, 26 except 25=-126(LC 6) Max Grav All reactions 250 lb or less at joint(s) 2, 24, 22, 33, 34, 36, 37, 38, 39, 40, 41, 32, 31, 30, 29, 28, 27, 26 except 42=334(LC 12), 25=402(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 21-25=-404/142 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 22, 33, 36, 37, 38, 39, 40, 41, 42, 31, 30, 29, 28, 27, 26 except (jt=lb) 25=126. 11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2, 24, 33, 34, 36, 37, 38, 39, 40, 41, 42, 32, 31, 30, 29, 28, 27, 26, 25. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss C Truss Type Piggyback Base Qty 10 Ply 1 EATON B Job Reference (optional) I30503593 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:00 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-TwpSs8zlZu9N1dlme9vFQvNbER7dU_iPB3AYzfywVGT Scale = 1:57.0 1 2 3 4 5 6 7 12 11 10 9 8 4x6 4x6 2x4 3x6 3x8 3x4 5x9 2x4 5x9 3x8 6-4-2 6-4-2 15-7-14 9-3-12 22-0-0 6-4-2 -1-3-4 1-3-4 6-4-2 6-4-2 11-0-0 4-7-14 15-7-14 4-7-14 22-0-0 6-4-2 23-3-4 1-3-4 3- 7 - 1 4 10 - 0 - 0 3- 7 - 1 4 10 - 0 - 0 12.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [3:0-4-4,0-1-12], [5:0-4-4,0-1-12], [6:0-3-8,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.72 0.51 0.19 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.31 0.01 (loc) 9-11 9-11 8 l/defl >999 >836 n/a L/d 240 180 n/a PLATES MT20 Weight: 129 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-12,2-11,6-8,6-9: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-12 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-11, 4-9 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)12=953/0-3-8, 8=953/0-3-8 Max Uplift 12=-105(LC 4), 8=-105(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-759/164, 3-4=-510/180, 4-5=-510/180, 5-6=-759/164, 2-12=-904/133, 6-8=-904/133 BOT CHORD 9-11=0/482 WEBS 2-11=0/429, 6-9=0/429 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 12=105, 8=105. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss CG Truss Type Piggyback Base Structural Gable COMMON l l Gable l Gable Qty 1 Ply 1 EATON B Job Reference (optional) I30503594 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:01 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-x6Nq3UzNKBHEfnKyCsQUz6wmAqVcDQHYPjw6W6ywVGS Scale = 1:59.5 Sheet Front Right Option 4-4-2 1 Ply 7/16" 4x8 OSB 1 2 3 4 5 6 7 17 16 15 13 12 11 10 9 814 4x6 4x6 3x6 3x8 3x4 5x9 5x9 3x8 2x8 6-4-2 6-4-2 14-0-0 7-7-14 15-7-14 1-7-14 17-7-14 2-0-0 22-0-0 4-4-2 -1-3-4 1-3-4 6-4-2 6-4-2 7-7-14 1-3-12 11-0-0 3-4-2 15-7-14 4-7-14 22-0-0 6-4-2 23-3-4 1-3-4 3- 7 - 1 4 10 - 0 - 0 3- 7 - 1 4 10 - 0 - 0 12.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [3:0-4-4,0-1-12], [5:0-4-4,0-1-12], [6:0-3-8,Edge], [29:0-1-0,0-2-4], [29:0-4-0,0-0-4], [31:0-1-12,0-1-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.71 0.33 0.23 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.12 0.00 (loc) 14-16 14-16 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 283 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-17,2-16,6-8,6-13: 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 3-16, 4-13, 5-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 8-3-8 except (jt=length) 17=0-3-8, 14=0-3-8. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 17, 8, 11, 9 except 13=-180(LC 4) Max Grav All reactions 250 lb or less at joint(s) 12, 11, 10, 9 except 17=684(LC 1), 8=313(LC 8), 13=699(LC 8), 14=281(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-506/154, 3-4=-329/173, 2-17=-630/123, 6-8=-271/92 WEBS 4-13=-437/61, 5-13=-306/28 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 8, 11, 9 except (jt=lb) 13=180. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss D Truss Type COMMON Qty 1 Ply 1 EATON B Job Reference (optional) I30503595 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:01 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-x6Nq3UzNKBHEfnKyCsQUz6wjCqVLDSqYPjw6W6ywVGS Scale = 1:59.9 1 2 3 4 5 8 7 6 4x6 2x4 2x4 3x8 6x8 6x8 7-0-0 7-0-0 14-0-0 7-0-0 -1-3-4 1-3-4 7-0-0 7-0-0 14-0-0 7-0-0 15-3-4 1-3-4 2- 7 - 1 0 9- 7 - 1 0 2- 7 - 1 0 12.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [4:0-3-8,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.90 0.35 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.12 0.00 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 74 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 *Except* 3-7: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-10-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)8=633/0-5-8, 6=633/0-5-8 Max Uplift 8=-83(LC 4), 6=-83(LC 4) Max Grav 8=654(LC 8), 6=654(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-510/123, 3-4=-510/123, 2-8=-591/117, 4-6=-591/117 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss DG Truss Type Roof Special Supported Gable Qty 1 Ply 1 EATON B Job Reference (optional) I30503596 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:02 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-PIxDHq_?5VP5Hxv9mZyjWKS3UEtKyo?heNff2YywVGR Scale = 1:60.2 Sheet Front Full Sheathing 1 Ply 7/16" 4x8 OSB 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 4x6 3-8-8 3-8-8 10-3-8 6-7-0 14-0-0 3-8-8 -1-3-4 1-3-4 3-8-8 3-8-8 7-0-0 3-3-8 10-3-8 3-3-8 14-0-0 3-8-8 15-3-4 1-3-4 3- 7 - 1 4 10 - 7 - 1 4 3- 7 - 1 4 3- 0 - 0 12.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-R 0.22 0.24 0.52 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 0.08 (loc) 14 15 16 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 226 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-27,11-19: 2x4 SPF Stud/No.3 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: 26-27,19-20. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 14-0-0. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 27, 26, 20, 19, 24, 29, 22, 17 except 30=-261(LC 4), 16=-261(LC 4), 23=-221(LC 5), 28=-140(LC 4), 18=-140(LC 4) Max Grav All reactions 250 lb or less at joint(s) 30, 16, 27, 26, 20, 19, 24, 25, 28, 29, 22, 21, 18, 17 except 23=501(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-30=-211/266, 2-3=-90/251, 3-4=-126/254, 4-5=-142/285, 5-6=-161/305, 6-7=-212/369, 7-8=-235/387, 8-9=-235/387, 9-10=-212/369, 10-11=-162/305, 11-12=-142/285, 12-13=-126/254, 13-14=-90/251, 14-16=-211/266 WEBS 8-23=-479/243 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Bearing at joint(s) 26, 20 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 27, 26, 20, 19, 24, 29, 22, 17 except (jt=lb) 30=261, 16=261, 23=221, 28=140, 18=140. 12) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 23, 24, 25, 22, 21. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss DG1 Truss Type Common Supported Gable Qty 1 Ply 1 EATON B Job Reference (optional) I30503597 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:02 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-PIxDHq_?5VP5Hxv9mZyjWKS3gEwJyuVheNff2YywVGR Scale = 1:54.7 Sheet Front Full Sheathing 1 Ply 7/16" 4x8 OSB 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 4x6 14-0-0 14-0-0 -1-3-4 1-3-4 7-0-0 7-0-0 14-0-0 7-0-0 15-3-4 1-3-4 2- 7 - 1 0 9- 7 - 1 0 2- 7 - 1 0 12.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-R 0.21 0.05 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 -0.00 0.00 (loc) 13 12 14 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 223 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 *Except* 7-19: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 7-19 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 14-0-0. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 21, 22, 23, 17, 16, 15 except 24=-166(LC 4), 14=-166(LC 4), 19=-182(LC 5) Max Grav All reactions 250 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15 except 19=440(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-134/260, 5-6=-188/327, 6-7=-211/347, 7-8=-211/347, 8-9=-188/327, 9-10=-134/260 WEBS 7-19=-424/209 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 21, 22, 23, 17, 16, 15 except (jt=lb) 24=166, 14=166, 19=182. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss DT Truss Type ROOF SPECIAL Qty 5 Ply 1 EATON B Job Reference (optional) I30503598 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:03 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-uVVbUA?espXyu5TLKHTy2X?C?eCZhCxrt1PCa_ywVGQ Scale = 1:61.1 1 2 3 4 5 6 7 14 13 12 11 10 9 8 4x6 2x4 3x6 2x4 2x4 3x6 3x4 2x4 3x8 3x6 3x4 3x6 1-5-8 1-5-8 7-0-0 5-6-8 12-6-8 5-6-8 14-0-0 1-5-8 -1-3-4 1-3-4 1-5-8 1-5-8 7-0-0 5-6-8 12-6-8 5-6-8 14-0-0 1-5-8 15-3-4 1-3-4 2- 7 - 1 0 9- 7 - 1 0 2- 7 - 1 0 1- 0 - 0 12.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.36 0.30 0.73 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.10 0.16 (loc) 11-12 11-12 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 84 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)14=633/0-5-8, 8=633/0-5-8 Max Uplift 14=-83(LC 4), 8=-83(LC 4) Max Grav 14=654(LC 8), 8=654(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-522/111, 4-5=-522/111, 2-14=-640/102, 6-8=-640/102 BOT CHORD 11-12=0/280, 10-11=0/280 WEBS 12-13=-466/7, 3-12=-423/32, 9-10=-466/7, 5-10=-423/32, 4-11=-33/267, 2-13=-12/527, 6-9=-12/527 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 8. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss EG Truss Type GABLE Qty 1 Ply 1 EATON B Job Reference (optional) I30503599 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:04 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-Mh3ziW0Gd6fpWE2Xt__BblYOD2ZMQm9_5h8m6RywVGP Scale = 1:62.5 Sheet Front Full Sheathing 1 Ply 7/16" 4x8 OSB 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 28 27 26 25 24 23 22 21 20 19 18 17 16 29 32 30 33 31 342x8 4x6 2x8 5x6 5x6 5x6 2- 6 - 0 17-5-8 17-5-8 -1-3-4 1-3-4 8-8-12 8-8-12 17-5-8 8-8-12 18-8-12 1-3-4 1- 3 - 1 9- 1 1 - 1 3 1- 3 - 1 12.00 12 Plate Offsets (X,Y)-- [4:0-3-0,0-3-0], [12:0-3-0,0-3-0], [26:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.27 0.14 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 -0.00 0.00 (loc) 15 14 16 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 257 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 *Except* 7-23,9-21: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 29, 30, 31, 32, 33 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 17-5-8. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 28, 16, 23, 24, 25, 26, 21, 20, 19, 18 except 27=-109(LC 4), 17=-114(LC 4) Max Grav All reactions 250 lb or less at joint(s) 28, 16, 23, 24, 25, 26, 27, 21, 20, 19, 18, 17, 22 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 28, 16, 23, 24, 25, 26, 21, 20, 19, 18 except (jt=lb) 27=109, 17=114. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss EGR Truss Type Common Girder Qty 1 Ply 2 EATON B Job Reference (optional) I30503600 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:04 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-Mh3ziW0Gd6fpWE2Xt__BblYMK2Y4QgQ_5h8m6RywVGP Scale = 1:61.7 1 2 3 4 5 11 10 9 8 7 6121314151617 3x8 4x6 3x8 5x6 6x8 12x12 3x6 12x12 3x6 12x12 5x6 4-6-2 4-6-2 8-8-12 4-2-10 12-11-6 4-2-10 17-5-8 4-6-2 4-6-2 4-6-2 8-8-12 4-2-10 12-11-6 4-2-10 17-5-8 4-6-2 1- 3 - 1 9- 1 1 - 1 3 1- 3 - 1 12.00 12 Plate Offsets (X,Y)-- [6:Edge,0-2-8], [7:0-3-8,0-6-0], [10:0-3-8,0-6-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.39 0.22 0.65 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.14 0.01 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 260 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x8 SP 2250F 1.8E WEBS 2x4 SPF Stud/No.3 *Except* 3-8: 2x4 SPF No.2, 1-11,5-6: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)11=6416/0-3-8, 6=6125/0-3-8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-5227/0, 2-3=-3998/14, 3-4=-3998/14, 4-5=-5361/0, 1-11=-4423/0, 5-6=-4511/0 BOT CHORD 10-11=0/738, 8-10=0/3628, 7-8=0/3723, 6-7=0/866 WEBS 3-8=0/5267, 4-8=-1526/66, 4-7=0/1906, 2-8=-1385/72, 2-10=0/1694, 1-10=0/2964, 5-7=0/2930 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 4) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 6-11=-20 Concentrated Loads (lb) Vert: 11=-1248 8=-1241 10=-1241 12=-1241 13=-1241 14=-1241 15=-1241 16=-1241 17=-1243 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss F Truss Type Common Qty 4 Ply 1 EATON B Job Reference (optional) I30503601 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:05 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-qtdLvs1uOQng8OdjRiVQ7y4RsSpS9Ek8KLuJftywVGO Scale = 1:24.7 1 2 3 4 6 5 7 8 4x6 3x6 3x6 3x6 2x4 7-2-0 7-2-0 14-4-0 7-2-0 -0-11-4 0-11-4 7-2-0 7-2-0 14-4-0 7-2-0 0- 3 - 1 5 2- 8 - 1 0 0- 3 - 1 5 4.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.79 0.53 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.20 0.03 (loc) 4-6 4-6 4 l/defl >999 >862 n/a L/d 240 180 n/a PLATES MT20 Weight: 37 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)4=559/0-3-8, 2=629/0-3-8 Max Horz 2=15(LC 6) Max Uplift 4=-78(LC 6), 2=-126(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1059/143, 3-4=-1057/142 BOT CHORD 2-6=-79/939, 4-6=-79/939 WEBS 3-6=0/341 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 2=126. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss FG Truss Type Common Supported Gable Qty 1 Ply 1 EATON B Job Reference (optional) I30503602 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:05 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-qtdLvs1uOQng8OdjRiVQ7y4X6Su09FB8KLuJftywVGO Scale = 1:24.7 Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 10 9 8 7 11 12 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 3x4 14-4-0 14-4-0 -0-11-4 0-11-4 7-2-0 7-2-0 14-4-0 7-2-0 0- 3 - 1 5 2- 8 - 1 0 0- 3 - 1 5 4.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.39 0.24 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 0.03 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 41 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 14-4-0. (lb) - Max Horz 2=15(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 6, 10, 2 except 9=-428(LC 12), 7=-104(LC 6) Max Grav All reactions 250 lb or less at joint(s) 6, 9, 2 except 10=609(LC 9), 7=636(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-9=-135/260, 3-10=-421/165, 5-7=-449/178 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 10, 2 except (jt=lb) 9=428, 7=104. 10) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 6, 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss H Truss Type MONO TRUSS Qty 8 Ply 1 EATON B Job Reference (optional) I30503603 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:06 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-I3Aj7B1W8kvXlYCw?P0fgAdllrGGuj8HZ?dtBJywVGN Scale = 1:19.7 1 2 3 5 4 5x9 2x4 2x4 3-11-8 3-11-8 -1-3-4 1-3-4 3-11-8 3-11-8 0- 4 - 7 3- 0 - 2 2- 4 - 4 8.00 12 Plate Offsets (X,Y)-- [3:0-3-3,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.20 0.11 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 -0.00 (loc) 2-5 2-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 3-5: 2x4 SPF Stud/No.3 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)3=130/0-3-8, 2=243/0-3-8 Max Horz 2=122(LC 4) Max Uplift 3=-28(LC 4), 2=-53(LC 4) Max Grav 3=173(LC 8), 2=243(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss HG Truss Type GABLE Qty 1 Ply 1 EATON B Job Reference (optional) I30503604 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:06 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-I3Aj7B1W8kvXlYCw?P0fgAdm0rHDujYHZ?dtBJywVGN Scale = 1:19.7 Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 6 5 2x4 2x4 2x4 2x4 2x4 -1-3-4 1-3-4 3-11-8 3-11-8 0- 4 - 7 3- 0 - 2 8.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.19 0.05 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 0.00 0.00 (loc) 1 1 5 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 16 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=187/3-11-8, 5=19/3-11-8, 6=176/3-11-8 Max Horz 2=45(LC 4) Max Uplift 2=-64(LC 4), 5=-22(LC 5), 6=-30(LC 4) Max Grav 2=211(LC 6), 5=25(LC 6), 6=245(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5, 6. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss J Truss Type SPECIAL Qty 9 Ply 1 EATON B Job Reference (optional) I30503605 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:07 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-mGk6KX28v11NNin6Z7XuDNAszFV7dzMQofNQjlywVGM Scale = 1:23.6 2 3 4 5 1 6 6x12 3x4 4x6 4x6 4-7-4 4-7-4 13-11-8 9-4-4 4-7-4 4-7-4 9-1-10 4-6-6 13-11-8 4-9-14 0- 5 - 1 1 3- 1 1 - 9 2- 1 1 - 9 1- 0 - 0 3.00 12 Plate Offsets (X,Y)-- [3:0-5-12,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.43 0.52 0.83 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.45 0.12 (loc) 2 2-5 5 l/defl >897 >362 n/a L/d 240 180 n/a PLATES MT20 Weight: 62 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-3: 2x8 SP 2250F 1.8E BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)5=541/0-3-8, 1=542/0-7-4 Max Horz 1=67(LC 6) Max Uplift 5=-113(LC 6), 1=-100(LC 6) Max Grav 5=624(LC 9), 1=564(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1579/403 BOT CHORD 2-5=-405/1603 WEBS 3-5=-1588/452 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 5=113. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss JG Truss Type GABLE Qty 1 Ply 1 EATON B Job Reference (optional) I30503606 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:07 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-mGk6KX28v11NNin6Z7XuDNAsDFZ4d9wQofNQjlywVGM Scale: 1/2"=1' Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 18 3x6 3x4 13-11-8 13-11-8 -0-11-4 0-11-4 13-11-8 13-11-8 0- 5 - 1 1 3- 1 1 - 9 3.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.41 0.26 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.03 0.06 0.00 (loc) 1 1 11 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 53 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 13-11-8. (lb) - Max Horz 2=46(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 2, 12, 13, 14, 15, 17 except 16=-203(LC 12) Max Grav All reactions 250 lb or less at joint(s) 11, 12, 13, 14, 15, 16 except 2=251(LC 9), 17=590(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-17=-411/164 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 12, 13, 14, 15, 17 except (jt=lb) 16=203. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss JG1 Truss Type GABLE Qty 1 Ply 1 EATON B Job Reference (optional) I30503607 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:08 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-ESIUYt3mgL9E?sMI6q28lbi4hfxxMdea0J6zGCywVGL Scale = 1:10.1 Sheet Back Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 2x4 2x4 2x8 -0-11-4 0-11-4 3-11-8 3-11-8 0- 5 - 1 1 1- 5 - 9 3.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.24 0.16 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 0.03 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 11 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)4=146/3-11-8, 2=216/3-11-8 Max Horz 2=19(LC 6) Max Uplift 4=-39(LC 6), 2=-82(LC 6) Max Grav 4=153(LC 9), 2=218(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss L Truss Type Monopitch Qty 8 Ply 1 EATON B Job Reference (optional) I30503608 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:08 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-ESIUYt3mgL9E?sMI6q28lbi56fxHMdHa0J6zGCywVGL Scale = 1:16.4 1 2 3 4 6 5 7 2x4 3x4 5x6 2x4 2x4 0-9-4 0-9-4 3-2-1 2-4-13 3-11-8 0-9-7 -0-11-4 0-11-4 3-11-8 3-11-8 0- 4 - 5 2- 8 - 0 1- 4 - 8 1- 3 - 8 1- 8 - 0 1- 0 - 0 7.00 12 5.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.15 0.14 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 6 2-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 2-6: 2x6 SPF No.2 WEBS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=229/0-9-4, 5=125/0-1-8 Max Horz 2=60(LC 6) Max Uplift 2=-65(LC 6), 5=-14(LC 6) Max Grav 2=231(LC 9), 5=151(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Bearing at joint(s) 2, 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss PB1 Truss Type Piggyback Qty 10 Ply 1 EATON B Job Reference (optional) I30503609 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:08 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-ESIUYt3mgL9E?sMI6q28lbi2tfxCMdia0J6zGCywVGL Scale = 1:30.4 1 2 3 45 6 4x6 2x4 2x4 2x4 9-3-12 9-3-12 4-7-14 4-7-14 9-3-12 4-7-14 0- 5 - 3 4- 6 - 4 0- 1 - 1 0 0- 5 - 3 0- 1 - 1 0 12.00 12 Plate Offsets (X,Y)-- [2:0-2-6,0-1-0], [4:0-2-6,0-1-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.36 0.14 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 0.02 0.00 (loc) 5 5 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 29 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=221/8-2-2, 4=221/8-2-2, 6=252/8-2-2 Max Uplift 2=-62(LC 4), 4=-62(LC 4) Max Grav 2=243(LC 8), 4=243(LC 8), 6=263(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss PB2 Truss Type GABLE Qty 1 Ply 1 EATON B Job Reference (optional) I30503610 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:09 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-iesslD4ORfH5c0xVgYaNIoFHS3Ju547jFzsXoeywVGK Scale = 1:31.1 Sheet Front Full Sheathing 1 Ply 7/16" 4x8 OSB 2 3 4 5 6 10 9 8 1 7 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 9-3-12 9-3-12 4-7-14 4-7-14 9-3-12 4-7-14 -0 - 0 - 4 4- 7 - 1 0 4- 7 - 1 4 0- 1 - 2 0- 1 - 1 0 12.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.11 0.05 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 61 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 9-3-12. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 2, 6, 9, 10, 8 except 1=-162(LC 8), 7=-162(LC 8) Max Grav All reactions 250 lb or less at joint(s) 1, 7, 9 except 2=304(LC 8), 6=304(LC 8), 10=263(LC 8), 8=263(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Bearing at joint(s) 1, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6, 9, 10, 8 except (jt=lb) 1=162, 7=162. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss V1 Truss Type Valley Qty 1 Ply 1 EATON B Job Reference (optional) I30503611 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:10 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-ArQEyZ41CyPyE9WhEF5cq0oQSTc4qVdtUdb4K4ywVGJ Scale = 1:51.2 1 2 3 4 5 8 7 63x4 4x6 3x4 5x6 2x4 2x4 2x4 2x4 16-1-12 16-1-12 8-0-14 8-0-14 16-1-12 8-0-14 8- 0 - 1 4 12.00 12 Plate Offsets (X,Y)-- [7:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.22 0.18 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 60 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 16-1-12. (lb) - Max Uplift All uplift 100 lb or less at joint(s) except 8=-155(LC 4), 6=-157(LC 4) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=480(LC 7), 6=478(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-382/200, 4-6=-382/200 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 155 lb uplift at joint 8 and 157 lb uplift at joint 6. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss V2 Truss Type Valley Qty 1 Ply 1 EATON B Job Reference (optional) I30503612 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:10 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-ArQEyZ41CyPyE9WhEF5cq0oRBTdKqWFtUdb4K4ywVGJ Scale = 1:44.0 1 2 3 4 5 8 7 63x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 13-9-12 13-9-12 6-10-14 6-10-14 13-9-12 6-10-14 6- 1 0 - 1 4 12.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.18 0.10 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 50 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 13-9-12. (lb) - Max Uplift All uplift 100 lb or less at joint(s) except 8=-140(LC 4), 6=-140(LC 4) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=410(LC 7), 6=410(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-334/180, 4-6=-334/180 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 140 lb uplift at joint 8 and 140 lb uplift at joint 6. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss V3 Truss Type Valley Qty 1 Ply 1 EATON B Job Reference (optional) I30503613 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:11 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-f1_cAv5fzGXpsJ5toycrNDKTcsxEZyB0iHLesXywVGI Scale = 1:37.0 1 2 3 43x6 4x6 3x6 2x4 11-5-12 11-5-12 5-8-14 5-8-14 11-5-12 5-8-14 5- 8 - 1 4 12.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.71 0.25 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 36 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=240/11-5-12, 3=240/11-5-12, 4=382/11-5-12 Max Uplift 1=-37(LC 4), 3=-37(LC 4) Max Grav 1=269(LC 7), 3=269(LC 7), 4=415(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 37 lb uplift at joint 1 and 37 lb uplift at joint 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss V4 Truss Type Valley Qty 1 Ply 1 EATON B Job Reference (optional) I30503614 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:11 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-f1_cAv5fzGXpsJ5toycrNDKY7syjZzG0iHLesXywVGI Scale = 1:30.8 1 2 3 42x8 4x6 2x8 2x4 9-1-12 9-1-12 4-6-14 4-6-14 9-1-12 4-6-14 4- 6 - 1 4 12.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.42 0.15 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=188/9-1-12, 3=188/9-1-12, 4=299/9-1-12 Max Uplift 1=-32(LC 4), 3=-32(LC 4) Max Grav 1=212(LC 7), 3=212(LC 7), 4=326(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 32 lb uplift at joint 1 and 32 lb uplift at joint 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss V5 Truss Type Valley Qty 1 Ply 1 EATON B Job Reference (optional) I30503615 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:12 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-7DY?NF6HkafgTTg4Lg74vRtkBGI8IR6Axw4BPzywVGH Scale = 1:23.6 1 2 3 42x4 4x6 2x4 2x4 6-9-12 6-9-12 3-4-14 3-4-14 6-9-12 3-4-14 3- 4 - 1 4 12.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.34 0.14 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 21 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=146/6-9-12, 3=146/6-9-12, 4=197/6-9-12 Max Uplift 1=-37(LC 4), 3=-37(LC 4) Max Grav 1=170(LC 7), 3=170(LC 7), 4=205(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 37 lb uplift at joint 1 and 37 lb uplift at joint 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss V6 Truss Type Valley Qty 1 Ply 1 EATON B Job Reference (optional) I30503616 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:12 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-7DY?NF6HkafgTTg4Lg74vRtoZGKUIRMAxw4BPzywVGH Scale = 1:14.0 1 2 3 4 2x4 4x6 2x4 2x4 4-5-12 4-5-12 2-2-14 2-2-14 4-5-12 2-2-14 2- 2 - 1 4 12.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.12 0.06 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=90/4-5-12, 3=90/4-5-12, 4=122/4-5-12 Max Uplift 1=-24(LC 4), 3=-24(LC 4) Max Grav 1=106(LC 7), 3=106(LC 7), 4=127(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 24 lb uplift at joint 1 and 24 lb uplift at joint 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss V7 Truss Type Valley Qty 1 Ply 1 EATON B Job Reference (optional) I30503617 8.030 s Feb 17 2017 MiTek Industries, Inc. Wed Jul 19 16:54:44 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:o1IbswuJ5L0wI_ogbZwuS8z0PC7-55dVKurhj8nK14M3nmfUINSdcmi5JwtlYcPc?hywRbP Scale = 1:16.5 1 2 3 5 4 2x8 2x4 2x4 2x4 2x4 5-7-13 5-7-13 9-2-11 3-6-14 2- 3 - 1 1 3.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.21 0.13 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 23 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=145/9-2-11, 4=93/9-2-11, 5=394/9-2-11 Max Horz 1=24(LC 7) Max Uplift 1=-21(LC 6), 4=-15(LC 6), 5=-91(LC 6) Max Grav 1=147(LC 11), 4=111(LC 8), 5=415(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-310/141 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 21 lb uplift at joint 1, 15 lb uplift at joint 4 and 91 lb uplift at joint 5. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss V8 Truss Type Valley Qty 1 Ply 1 EATON B Job Reference (optional) I30503618 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:13 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:o1IbswuJ5L0wI_ogbZwuS8z0PC7-bQ6Nbb7vVtoX5dEGvNeJSeQoNgZf1utJAaqkxPywVGG Scale = 1:12.2 1 2 3 4 2x8 2x4 2x4 6-6-11 6-6-11 1- 7 - 1 1 3.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.82 0.51 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 WEBS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=209/6-6-11, 3=209/6-6-11 Max Horz 1=17(LC 6) Max Uplift 1=-49(LC 6), 3=-53(LC 6) Max Grav 1=215(LC 11), 3=219(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 49 lb uplift at joint 1 and 53 lb uplift at joint 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss V9 Truss Type Valley Qty 1 Ply 1 EATON B Job Reference (optional) I30503619 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:13 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-bQ6Nbb7vVtoX5dEGvNeJSeQxegf21uUJAaqkxPywVGG Scale = 1:20.5 1 2 3 4 2x4 4x6 2x4 2x4 5-9-8 5-9-8 2-10-12 2-10-12 5-9-8 2-10-12 2- 1 0 - 1 2 12.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.23 0.10 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=122/5-9-8, 3=122/5-9-8, 4=164/5-9-8 Max Uplift 1=-32(LC 4), 3=-32(LC 4) Max Grav 1=142(LC 7), 3=142(LC 7), 4=171(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 32 lb uplift at joint 1 and 32 lb uplift at joint 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 Job 1700581 Truss V10 Truss Type Valley Qty 1 Ply 1 EATON B Job Reference (optional) I30503620 8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Jul 19 12:44:10 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:XKfs12wh5zLTEiE4KIN98jzfLiZ-ArQEyZ41CyPyE9WhEF5cq0oT_TcrqX7tUdb4K4ywVGJ Scale = 1:11.5 1 2 3 2x4 3x6 2x4 3-5-8 3-5-8 1-8-12 1-8-12 3-5-8 1-8-12 1- 8 - 1 2 12.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.06 0.13 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=110/3-5-8, 3=110/3-5-8 Max Uplift 1=-13(LC 4), 3=-13(LC 4) Max Grav 1=123(LC 7), 3=123(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 13 lb uplift at joint 1 and 13 lb uplift at joint 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. July 20,2017 e d g e o f t r u s s . f r o m o u t s i d e " 1 6 / 1 - 0 P R O D U C T C O D E A P P R O V A L S J O I N T S A R E G E N E R A L L Y N U M B E R E D / L E T T E R E D C L O C K W I S E A R O U N D T H E T R U S S S T A R T I N G A T T H E J O I N T F A R T H E S T T O T H E L E F T . C H O R D S A N D W E B S A R E I D E N T I F I E D B Y E N D J O I N T N U M B E R S / L E T T E R S . W 4 - 6 W3-6 W 3 - 7 W2-7 W 1 - 7 C1-8 C 5 - 6 C 6 - 7 C 7 - 8 C4-5 C 3 - 4 C 2 - 3 C 1 - 2 TOP CHORD TOP CHORD 8 7 6 5 4 3 2 1 B O T T O M C H O R D S T O P C H O R D S B E A R I N G L A T E R A L B R A C I N G L O C A T I O N I n d i c a t e s l o c a t i o n w h e r e b e a r i n g s ( s u p p o r t s ) o c c u r . I c o n s v a r y b u t r e a c t i o n s e c t i o n i n d i c a t e s j o i n t n u m b e r w h e r e b e a r i n g s o c c u r . M i n s i z e s h o w n i s f o r c r u s h i n g o n l y . I n d i c a t e d b y s y m b o l s h o w n a n d / o r b y t e x t i n t h e b r a c i n g s e c t i o n o f t h e o u t p u t . U s e T o r I b r a c i n g i f i n d i c a t e d . T h e f i r s t d i m e n s i o n i s t h e p l a t e w i d t h m e a s u r e d p e r p e n d i c u l a r t o s l o t s . S e c o n d d i m e n s i o n i s t h e l e n g t h p a r a l l e l t o s l o t s . 4 x 4 P L A T E S I Z E T h i s s y m b o l i n d i c a t e s t h e r e q u i r e d d i r e c t i o n o f s l o t s i n c o n n e c t o r p l a t e s . " 1 6 / 1 F o r 4 x 2 o r i e n t a t i o n , l o c a t e p l a t e s 0 - C e n t e r p l a t e o n j o i n t u n l e s s x , y o f f s e t s a r e i n d i c a t e d . D i m e n s i o n s a r e i n f t - i n - s i x t e e n t h s . A p p l y p l a t e s t o b o t h s i d e s o f t r u s s a n d f u l l y e m b e d t e e t h . 1 " 4 / 3 P L A T E L O C A T I O N A N D O R I E N T A T I O N S y m b o l s N u m b e r i n g S y s t e m 1 . A d d i t i o n a l s t a b i l i t y b r a c i n g f o r t r u s s s y s t e m , e . g . d i a g o n a l o r X - b r a c i n g , i s a l w a y s r e q u i r e d . S e e B C S I . 2 . T r u s s b r a c i n g m u s t b e d e s i g n e d b y a n e n g i n e e r . F o r w i d e t r u s s s p a c i n g , i n d i v i d u a l l a t e r a l b r a c e s t h e m s e l v e s m a y r e q u i r e b r a c i n g , o r a l t e r n a t i v e T o r I b r a c i n g s h o u l d b e c o n s i d e r e d . 3 . N e v e r e x c e e d t h e d e s i g n l o a d i n g s h o w n a n d n e v e r s t a c k m a t e r i a l s o n i n a d e q u a t e l y b r a c e d t r u s s e s . 4 . P r o v i d e c o p i e s o f t h i s t r u s s d e s i g n t o t h e b u i l d i n g d e s i g n e r , e r e c t i o n s u p e r v i s o r , p r o p e r t y o w n e r a n d a l l o t h e r i n t e r e s t e d p a r t i e s . 5 . C u t m e m b e r s t o b e a r t i g h t l y a g a i n s t e a c h o t h e r . 6 . P l a c e p l a t e s o n e a c h f a c e o f t r u s s a t e a c h j o i n t a n d e m b e d f u l l y . K n o t s a n d w a n e a t j o i n t l o c a t i o n s a r e r e g u l a t e d b y A N S I / T P I 1 . 7 . D e s i g n a s s u m e s t r u s s e s w i l l b e s u i t a b l y p r o t e c t e d f r o m t h e e n v i r o n m e n t i n a c c o r d w i t h A N S I / T P I 1 . 8 . U n l e s s o t h e r w i s e n o t e d , m o i s t u r e c o n t e n t o f l u m b e r s h a l l n o t e x c e e d 1 9 % a t t i m e o f f a b r i c a t i o n . 9 . U n l e s s e x p r e s s l y n o t e d , t h i s d e s i g n i s n o t a p p l i c a b l e f o r u s e w i t h f i r e r e t a r d a n t , p r e s e r v a t i v e t r e a t e d , o r g r e e n l u m b e r . 1 0 . C a m b e r i s a n o n - s t r u c t u r a l c o n s i d e r a t i o n a n d i s t h e r e s p o n s i b i l i t y o f t r u s s f a b r i c a t o r . G e n e r a l p r a c t i c e i s t o c a m b e r f o r d e a d l o a d d e f l e c t i o n . 1 1 . P l a t e t y p e , s i z e , o r i e n t a t i o n a n d l o c a t i o n d i m e n s i o n s i n d i c a t e d a r e m i n i m u m p l a t i n g r e q u i r e m e n t s . 1 2 . L u m b e r u s e d s h a l l b e o f t h e s p e c i e s a n d s i z e , a n d i n a l l r e s p e c t s , e q u a l t o o r b e t t e r t h a n t h a t s p e c i f i e d . 1 3 . T o p c h o r d s m u s t b e s h e a t h e d o r p u r l i n s p r o v i d e d a t s p a c i n g i n d i c a t e d o n d e s i g n . 1 4 . B o t t o m c h o r d s r e q u i r e l a t e r a l b r a c i n g a t 1 0 f t . s p a c i n g , o r l e s s , i f n o c e i l i n g i s i n s t a l l e d , u n l e s s o t h e r w i s e n o t e d . 1 5 . C o n n e c t i o n s n o t s h o w n a r e t h e r e s p o n s i b i l i t y o f o t h e r s . 1 6 . D o n o t c u t o r a l t e r t r u s s m e m b e r o r p l a t e w i t h o u t p r i o r a p p r o v a l o f a n e n g i n e e r . 1 7 . I n s t a l l a n d l o a d v e r t i c a l l y u n l e s s i n d i c a t e d o t h e r w i s e . 1 8 . U s e o f g r e e n o r t r e a t e d l u m b e r m a y p o s e u n a c c e p t a b l e e n v i r o n m e n t a l , h e a l t h o r p e r f o r m a n c e r i s k s . C o n s u l t w i t h p r o j e c t e n g i n e e r b e f o r e u s e . 1 9 . R e v i e w a l l p o r t i o n s o f t h i s d e s i g n ( f r o n t , b a c k , w o r d s a n d p i c t u r e s ) b e f o r e u s e . R e v i e w i n g p i c t u r e s a l o n e i s n o t s u f f i c i e n t . 2 0 . D e s i g n a s s u m e s m a n u f a c t u r e i n a c c o r d a n c e w i t h A N S I / T P I 1 Q u a l i t y C r i t e r i a . F a i l u r e t o F o l l o w C o u l d C a u s e P r o p e r t y D a m a g e o r P e r s o n a l I n j u r y G e n e r a l S a f e t y N o t e s * P l a t e l o c a t i o n d e t a i l s a v a i l a b l e i n M i T e k 2 0 / 2 0 s o f t w a r e o r u p o n r e q u e s t . I n d u s t r y S t a n d a r d s : 6 - 4 - 8 d i m e n s i o n s s h o w n i n f t - i n - s i x t e e n t h s ( D r a w i n g s n o t t o s c a l e ) © 2 0 1 2 M i T e k ® A l l R i g h t s R e s e r v e d M i T e k E n g i n e e r i n g R e f e r e n c e S h e e t : M I I - 7 4 7 3 r e v . 1 0 / 0 3 / 2 0 1 5 W E B S e d g e o f t r u s s . f r o m o u t s i d e " 1 6 / 1 - 0 I C C - E S R e p o r t s : E S R - 1 3 1 1 , E S R - 1 3 5 2 , E S R 1 9 8 8 E R - 3 9 0 7 , E S R - 2 3 6 2 , E S R - 1 3 9 7 , E S R - 3 2 8 2 J O I N T S A R E G E N E R A L L Y N U M B E R E D / L E T T E R E D C L O C K W I S E A R O U N D T H E T R U S S S T A R T I N G A T T H E J O I N T F A R T H E S T T O T H E L E F T . C H O R D S A N D W E B S A R E I D E N T I F I E D B Y E N D J O I N T N U M B E R S / L E T T E R S . W 4 - 6 W3-6 W 3 - 7 W2-7 W 1 - 7 C1-8 C 5 - 6 C 6 - 7 C 7 - 8 C4-5 C 3 - 4 C 2 - 3 C 1 - 2 TOP CHORD TOP CHORD 8 7 6 5 4 3 2 1 B O T T O M C H O R D S T O P C H O R D S B E A R I N G I n d i c a t e s l o c a t i o n w h e r e b e a r i n g s ( s u p p o r t s ) o c c u r . I c o n s v a r y b u t r e a c t i o n s e c t i o n i n d i c a t e s j o i n t n u m b e r w h e r e b e a r i n g s o c c u r . 4 x 4 P L A T E S I Z E T h i s s y m b o l i n d i c a t e s t h e r e q u i r e d d i r e c t i o n o f s l o t s i n c o n n e c t o r p l a t e s . " 1 6 / 1 F o r 4 x 2 o r i e n t a t i o n , l o c a t e p l a t e s 0 - 1 " 4 / 3 P L A T E L O C A T I O N A N D O R I E N T A T I O N S y m b o l s N u m b e r i n g S y s t e m G e n e r a l S a f e t y N o t e s * P l a t e l o c a t i o n d e t a i l s a v a i l a b l e i n M i T e k 2 0 / 2 0 s o f t w a r e o r u p o n r e q u e s t . I n d u s t r y S t a n d a r d s : A N S I / T P I 1 : N a t i o n a l D e s i g n S p e c i f i c a t i o n f o r M e t a l P l a t e C o n n e c t e d W o o d T r u s s C o n s t r u c t i o n . D S B - 8 9 : D e s i g n S t a n d a r d f o r B r a c i n g . B C S I : B u i l d i n g C o m p o n e n t S a f e t y I n f o r m a t i o n , G u i d e t o G o o d P r a c t i c e f o r H a n d l i n g , I n s t a l l i n g & B r a c i n g o f M e t a l P l a t e C o n n e c t e d W o o d T r u s s e s . 6 - 4 - 8 d i m e n s i o n s s h o w n i n f t - i n - s i x t e e n t h s W E B S T r u s s e s a r e d e s i g n e d f o r w i n d l o a d s i n t h e p l a n e o f t h e t r u s s u n l e s s o t h e r w i s e s h o w n . L u m b e r d e s i g n v a l u e s a r e i n a c c o r d a n c e w i t h A N S I / T P I 1 s e c t i o n 6 . 3 T h e s e t r u s s d e s i g n s r e l y o n l u m b e r v a l u e s e s t a b l i s h e d b y o t h e r s .