HomeMy WebLinkAboutA000.3SCALE:FRONT ELEVATION1/4" = 1'-0"-
\A1;1'-1"
1012
1012
3:12
SHINGLES PERSUB. SPECS.
9" CROSSHEAD14" PANELED SHUTTERS (TYP.)
FYPON LV12x36 OR EQUIV., TYP.
SHINGLES PERSUB. SPECS.
STONE VENEERPER SPECS9" CROSSHEAD
OPT. STANDING SEAM METAL ROOF W/ SEAMS @ 18" O.C.
4" TRIM SURROUND ON DOOR STONE VENEER PER SPECS
\A1;2'-11{\H0.75x;\S5#8;}"
\A1;3'-6"
VERTICAL SIDING PER SPECS
STONE SILL6" TRIM BOARD (TYP.)DRIP CAP
9" CROSSHEAD OVER DOOR
\A1;2'-11{\H0.75x;\S5#8;}"
C L
10123:12
20202020
GABLE VENT PER SPEC
SHINGLES PER SUB SPECS.SHINGLES PER SUB SPECS.FIXEDFIXED
\A1;24'-6{\H0.75x;\S1#2;}"\A1;6'-0"
\A1;8'-1{\H0.75x;\S1#8;}"\A1;7'-2{\H0.75x;\S7#8;}"
ROOF W/\POPT. LOFT
\A1;9'-1{\H0.75x;\S1#8;}"\A1;OPT. 10'-1{\H0.7x;\S1#8;}" \A1;8'-2{\H0.75x;\S7#8;}"\A1;9'-2{\H0.7x;\S7#8;}" @ OPT. 10' PL.
WINDOW HEIGHT
1st FLR LINE
PLATE HEIGHT
SECOND FLOOR PLATE (OPT. LOFT)WINDOW HDR. HGT.
TOP OF FOUNDATION\A1;4'-6" A.F.F.
9" CROSSHEAD4" TRIM BOARD4" SILL (SEE PORCH DETAIL)VERTICAL SIDING PER SPECS
SCALE:REAR ELEVATION1/8" = 1'-0"-
OPT. BRICK HEIGHT
SCALE:LEFT ELEVATION1/8" = 1'-0"-
OPT. DOOR\PPER PLAN
\A1;8'-4{\H0.75x;\S3#8;}"\A1;HDR. HGT. @ 4010 OPT. BRICK HEIGHT
127 127
SCALE:ROOF PLAN1/8" = 1'-0"-
ROOF AREA"A"3104 SQ. FT.
10:12 10:12
\A1;10'-0"10:1210:12
5:12
5:12
OPT. POT VENTS
\A1;14'-0"5:12
10:12
3:12
3:12
OPT. GUTTER AND DOWNSPOUTS
OPT 7:12 OPT 7:12
OPT 7:12
5:12OPT 7:12 5:12OPT 7:12
\A1;8'-0"\A1;8'-0"
\A1;8'-0"
ELEVATION CT2H
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 3104 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 4.14 5.17 5.08 49.73 12 0
AT EAVE 6.21 5.17 5.14 50.27 0 74.00
TOTAL (MIN)10.35 10.35 10.22 100.00
3
HIGH -
RIDGE VENT 4.14 5.17 6.00 53.87 0 0 48.00
AT EAVE 6.21 5.17 5.14 46.13 0 74.00
TOTAL (MIN)10.35 10.35 11.14 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
\A1;1'-1"\A1;1'-1"
512
\A1;2'-0"WINDOW HEIGHT
1st FLR LINE
CEILING HEIGHT
STONE VENEER
PER SPECS6" CORNER BD.
ON FRONT ELEV. &4" ON SIDES& REAR ELEV.OPT. BRICK HEIGHT
SECOND FLOOR PLATE (OPT. LOFT)
\A1;8'-1{\H0.75x;\S1#8;}"\A1;7'-2{\H0.75x;\S7#8;}"
WINDOW HDR. HGT.
OPT. WINDOWS\PPER PLAN
127ROOF W/\POPT. LOFT 127
\A1;9'-1{\H0.75x;\S1#8;}"\A1;OPT. 10'-1{\H0.7x;\S1#8;}" \A1;8'-2{\H0.75x;\S7#8;}"\A1;9'-2{\H0.7x;\S7#8;}" @ OPT. 10' PL.TOP OF FOUNDATION
\A1;1'-1"
1 9 0 0 G o l f R o a d , S u i t e 3 0 0
S c h a u m b u r g , I l l i n o i s 6 0 1 7 3
Mi
d
w
e
s
t
Z
o
n
e
O
f
f
i
c
e
...........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2017
RICK STARKEY06/07/2013
GARAGE LEFT
Croix
1993.301
--
08/01/2017
PLOTTED: October 6, 2017 / Mark Muurisepp / 1993-CROIX-CZ-BAS2-EL-CT2H.DWG
A3
CT2H-2GS.1
Cot
t
a
g
e
2
H
-
S
l
a
b
2 C
a
r
F
r
o
n
t
E
n
t
r
y
w
/
G
o
l
f
C
a
r
t
S
t
o
r
a
g
e
A
r
e
a
Fro
n
t
,
S
i
d
e
a
n
d
R
e
a
r
E
l
e
v
a
t
i
o
n
s
,
R
o
o
f
P
l
a
n
a
n
d
V
e
n
t
i
l
a
t
i
o
n
S
c
h
e
d
u
l
e
stone wainscoting in shadow
6:12 in shadow wood
12" overhangs 4
sides
07/10/18
Mike Sheeks