HomeMy WebLinkAbout18070137 State ReleaseELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
Use Internet Browser to View this report, other browsers are not compatible to view this report
Page 1/2
CONSTRUCTION DESIGN RELEASE
State Form 41191 (R9/5-98)
Report Printed on: July 23, 2018
Project number Release date
398388 03/07/18
Construction type Occupancy classification
Scope of release
II-B, SPK F-1, B, ADD, REM
Type of release
Project name
Street address
City County
ARCH ELEC FDN MECH
PLUM STR
Standard
World Wide Motors
3900 E 96th Street
INDIANAPOLIS MARION
To: Owner / Architect / Engineer
Versatile Construction Group
Trent A A Baxter PE19700309
570 Tracy Road
Suite 610
Whiteland IN 46184
Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans
and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety
Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000.
The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of
the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions
listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All
construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with
and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation
of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and
void, if the work authorized is not commenced within one (1) year from the above date.
CONDITIONS:
14B
14W1104A
14B0601IIB
4G0603AE
A2
14B100910
14B10073
AREL
This project has been reviewed under the 2014 Indiana Building Code.
Required means of egress shall be maintained during construction and demolition, remodeling or
alterations and additions to any building, in accordance with Section 1104, IFC (675 IAC 22-2.5).
The minimum construction type permitted for this building is Type II-B. Building elements shall be
protected as specified in Chapters 5, 6, and Table 601, IBC (675 IAC 13-2.6).
Detailed plans and specifications of the fire suppression system shall be filed with the required
application and appropriate fees in accordance with 675 IAC 12-6-3(a), 675 IAC 12-6-7(g)(17), and
675 IAC 13-1-8. (N.F.P.A. 13)
An elevator installation permit shall be obtained from the Elevator Safety Division in accordance with
IESC (675 IAC 21-1-1). Please visit: http://www.in.gov/dhs/2374.htm
A flight of stairs shall not have a vertical rise greater than 12 feet between floor levels or landings in
accordance with Section 1009.10, IBC (675 IAC 13-2.6).
In order to be considered part of an accessible means of egress, a stairway shall have a clear width
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
Use Internet Browser to View this report, other browsers are not compatible to view this report
Page 2/2
Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the
Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above -
stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire
and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you
choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will
be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will
be final, and you must comply with its requirements.
Code review official
Address (name,title of local official,street,city,state and ZIP code
KEVIN HANSON
Michael Bennett
Division of Compliance
1200 Madison Ave Suite 100
Indianapolis, IN 46204
Manager of Bldg Code Analysis
Fax & e-mail: 3173278475, planreview.class1@indy.gov
khanson@dhs.in.gov Director, Division of Fire and Building Safety
of 48 inches minimum between handrails in accordance with Section 1007.3, IBC (675 IAC 13-2.6).
NOTE: Flexible air ducts, both metallic and nonmetallic, shall comply with Sections 603.6.1,
603.6.1.1, 603.6.3 and 603.6.4, IMC. Flexible air connectors, both metallic and nonmetallic, shall
comply with Sections 603.6.2 through 603.6.4, IMC, in accordance with Section 603.6, IMC.
THIS IS NOT AN APPROVAL. Possession of this Construction Design Release does not grant or
imply approval of the released work, nor is it a statement that said work meets all applicable rules of
the Indiana Fire and Building Safety Commission. All work must be in full compliance with the
applicable rule, and responsibility for such compliance rests with the applicant.
Indiana Department of Homeland Security
DIVISION OF FIRE & BUILDING SAFETY
PLAN REVIEW DIVISION
402 W. Washington St., Room E245
Indianapolis, IN 46204
Fax & e-mail:
SUPPORT HOOSIER SAFETY
Available At Your Local Licence Branch
In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform
exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a
copy of the design release.
3175353581, tbaxter@versatile-llc.com