Loading...
HomeMy WebLinkAboutA000.21901 North Roselle Road, Suite 1000Schaumburg, Illinois 60195Pulte Central Zone102/05/2016PLAN REVISIONS........................ PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2016 Joel Hampshire3/30/2015 GARAGE LEFT 2975-Naples 1815.0000 -- 01/02/2017 PLOTTED: January 8, 2017 / SCA / 2975-IN-FRMP.DWG Building Sections and Details Full Basement3.31b SCALE 1/4" = 1'-0"SECTION THRU FOYER & GATHERING - ELEVATION 1 \A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.7x;\S1#8;}" (WINDOW HEAD HT, TYP.) \A1;7' 2-1/2" ( WINDOW HEAD HT. TYP. ) 128 128 BASEMENT DINING ROOM FOYER R-38 BLOWN \PINSULATION OPEN BELOW FLOOR SYSTEM PER MANUF. PRE-ENGINEERED GARAGE TRUSSES @ 24" O.C. MAX. SEE TRUSS DRAWINGS DESIGNED & PREPARED BY OTHERS FLOOR SYSTEM PER MANUF. TOP OF FOOTING SECOND FLOOR PL.BOTTOM OF HEADER SECOND FLOOR HT.FIRST FLOOR PL.BOTTOM OF HEADER FIRST FLOOR HT.TOP OF PLATE GARAGE PL. 126 128 3080 FR. DOOR TOP OF FOOTING \A1;7'-11{\H0.750000x;\S1#2;}" \A1;8'-11{\H0.750000x;\S1#2;}" @ OPT. 9' BASEMENT \A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.7x;\S1#8;}" (WINDOW HEAD HT, TYP.) \A1;7' 2-1/2" ( WINDOW HEAD HT. TYP. ) TOP OF FOOTING SECOND FLOOR PL.BOTTOM OF HEADER SECOND FLOOR HT.FIRST FLOOR PL.BOTTOM OF HEADER FIRST FLOOR HT.TOP OF PLATE GARAGE PL.\A1;1'-0"\A1;2'-0"\A1;13'-11{\H0.750000x;\S1#2;}"\A1;2'-0" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;10'-1{\H0.750000x;\S1#8;}" BASEMENT OWNER'S SUITE BEDROOM #2 GARAGEOWNER'S BATHOWNER'S WIC LAUNDRY \A1;8'-1{\H0.750000x;\S1#8;}"\A1;5'-2{\H0.750000x;\S1#4;}" \A1;1'-3{\H0.750000x;\S1#8;}" \A1;1'-2{\H0.750000x;\S7#8;}" \A1;3'-11{\H0.750000x;\S1#2;}" FLOOR SYSTEM PER MANUF. FLOOR SYSTEM PER MANUF. PRE-ENGINEERED ROOF TRUSSES @ 24" O.C. MAX. SEE TRUSS DRAWINGS DESIGNED & PREPARED BY OTHERS PRE-ENGINEERED ROOF TRUSSES @ 24" O.C. MAX. SEE TRUSS DRAWINGS DESIGNED & PREPARED BY OTHERS PRE-ENGINEERED ROOF TRUSSES @ 24" O.C. MAX. SEE TRUSS DRAWINGS DESIGNED & PREPARED BY OTHERS 128 128 BEDROOM #3BATH #2 SCALE 1/4" = 1'-0"THRU OWNER'S SUITE, LAUNDRY, GARAGE - ELEVATION 1 126 TOP OF FOOTING \A1;7'-11{\H0.750000x;\S1#2;}" \A1;8'-11{\H0.750000x;\S1#2;}" @ OPT. 9' BASEMENT \A1;12'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-7{\H0.750000x;\S1#2;}" 1214 1214 BASEMENT OFFICE \A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.7x;\S1#8;}" (WINDOW HEAD HT, TYP.) TOP OF FOOTING FIRST FLOOR PL.BOTTOM OF HEADER FIRST FLOOR HT.TOP OF PLATE GARAGE PL. SCALE 1/4" = 1'-0"THRU OWNER'S SUITE, LAUNDRY, GARAGE - ELEVATION 1 \A1;6{\H0.750000x;\S1#8;}"\A1;3'-0" PRE-ENGINEERED ROOF TRUSSES @ 24" O.C. MAX. SEE TRUSS DRAWINGS DESIGNED & PREPARED BY OTHERS 129 \A1;7'-11{\H0.750000x;\S1#2;}" \A1;8'-11{\H0.750000x;\S1#2;}" @ OPT. 9' BASEMENTTOP OF FOOTING 07/12/18 Mike Sheeks