Loading...
HomeMy WebLinkAboutA000.4PLOTTED: June 13, 2017 / SCA / 2975-IN-NAPLES-EC01.DWG A3-EC01 1FB.3Euro Country2 Car Side EntryElevations and Roof Plan1901 North Roselle Road, Suite 1000Schaumburg, Illinois 60195Pulte Central Zone102/05/2016PLAN REVISIONS........................ PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2017 Joel Hampshire3/30/2015 GARAGE LEFT 2975-Naples 1815.0000 -- 06/13/2017 SCALE:FRONT ELEVATION1/4" = 1'-0"- ROOF SHINGLES, PER SPEC FYPON #LV12X24 OR APPROVED EQUAL\A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION 8" FASCIA, PER SPEC8" FRIEZE, PER SPEC4" CORNER BOARD, PER SPECHORIZONTAL SIDING, PER SPEC BRICK SOLDIER COURSE, PER SPEC18"x60" PANEL SHUTTERS, PER SPEC BRICK SOLDIER COURSE, PER SPEC 1x3 OVER 8" RAKE BOARD, PER SPEC 4" FRIEZE, PER SPEC STONE SILL, PER SPEC STONE VENEER, PER SPEC 1214 2030 FX 8:12 \A1;2'-6" 8:12 12:12 8:12 12:12 12:12 12:12 8:12 3:122650 FX \A1;3'-1"\A1;3'-1" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;PLATE HEIGHT \A1;1'-0" \A1;7'-8{\H0.750000x;\S3#8;}"\A1;7'-4{\H0.750000x;\S3#4;}" \A1;4'-0"\A1;4'-0" 4" FRIEZE, PER SPEC 1214 1214 1214 12141214 1214 1214 1214 BLACKOUT WINDOW 4" TRIM BOARD, PER SPEC 6" TRIM BOARD, PER SPECFYPON BRACKET #DTLB6X6X5\POR APPROVED EQUAL 6" TRIM BOARD, PER SPEC \A1;3'-6"\A1;MIN. LINE OF ROOF w/ BONUS ROOM OPT. TOP OF FOOTING STONE SILL, PER SPEC SCALE:ROOF PLAN1/8" = 1'-0"- OPT. GUTTER AND DOWNSPOUTS \pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION, TYP. "A"2986ROOF AREA:SQ. FT. \pxi-4,l4,ql,t3;OPT. POT VENTS"B"28ROOF AREA:SQ. FT. 14:12 14:12 14:12 \pxi-4,l4,ql,t3;POT VENT \A1;13'-0" \A1;5'-8{\H0.750000x;\S1#2;}"\A1;2'-7" \A1;7'-5" \A1;1'-3"\A1;2'-7" \A1;6'-10{\H0.750000x;\S1#4;}" \A1;32'-8" \A1;3'-6"\A1;2'-4{\H0.750000x;\S241#256;}" \A1;3'-6"\A1;3'-6" 14:1214:12 14:12 14:1214:12 14:12 14:12 14:12 14:1214:1214:1214:12 8:12 8:12 8:12 8:12 8:12 8:12 14:128:12 \A1;12'-0" \A1;10'-0" \A1;5'-0" 8:12 8:12 3:12 3:12 SCALE:LEFT ELEVATION1/8" = 1'-0"- TOP OF PLATE ROOF SHINGLES, PER SPEC WINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}" 8" FASCIA, PER SPEC10" FRIEZE, PER SPEC 4" CORNER BOARD, PER SPEC4" TRIM BOARD (TYP.), PER SPECHORIZONTAL SIDING, PER SPECOPT. MASONRY WRAP, PER SPEC STONE VENEER, PER SPECBRICK SOLDIER COURSE, PER SPEC 4" FRIEZE, PER SPEC10" FRIEZE, PER SPEC \A1;2'-6" \A1;15'-6{\H0.750000x;\S1#4;}" TOP OF PLATE1x3 OVER 8" RAKE BOARD, PER SPEC4" FRIEZE, PER SPEC 128 128128128 128 128 \A1;3'-6"\A1;MIN. TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}"\A1;3'-6"\A1;MIN. ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPEC4" FRIEZE, PER SPEC BRICK SOLDIER COURSE, PER SPECSTONE VENEER, PER SPEC BLACKOUT WINDOW OPT. MASONRY WRAP, PER SPEC4" CORNER BOARD, PER SPEC4" TRIM BOARD (TYP.), PER SPEC SCALE:RIGHT ELEVATION1/8" = 1'-0"- \A1;2'-6" \A1;7'-1{\H0.750000x;\S1#8;}"\A1;HEAD HT. 123 128 128 128 1214 128 2030 FX 2030 FX 1x3 OVER 6" RAKE BOARD, PER SPEC4" FRIEZE, PER SPEC 10" FRIEZE, PER SPEC4" TRIM BOARD, PER SPEC \A1;15'-6{\H0.750000x;\S1#8;}" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}" 1214 OPT. MASONRY WRAP, PER SPEC4" CORNER BOARD, PER SPEC ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPEC HARDIE PANEL (SMOOTH), PER SPEC6" TRIM BOARD (TYP.), PER SPEC SCALE:REAR ELEVATION1/8" = 1'-0"- \A1;15'-6{\H0.750000x;\S1#8;}"\A1;PLATE HT. 1214 1214 1214 8" TRIM BOARD, PER SPEC 4" TRIM BOARD, PER SPEC 6" TRIM BOARD (TYP.), PER SPEC ELEVATION EC01 ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 2986 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POTVENTS ONLY 3.98 4.98 4.66 46.89 11 0 AT EAVE 5.97 4.98 5.28 53.11 0 76.00 TOTAL (MIN)9.95 9.95 9.94 100.00 3 HIGH - RIDGE VENT 3.98 4.98 5.00 50.00 0 0 40.00 AT EAVE 5.97 4.98 5.00 50.00 0 72.00 TOTAL (MIN)9.95 9.95 10.00 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION EC01 ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 28 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POTVENTS ONLY 0.04 0.05 0.28 80.00 0 1 AT EAVE 0.06 0.05 0.07 20.00 0 1.00 TOTAL (MIN)0.09 0.09 0.35 100.00 3 HIGH - RIDGE VENT 0.04 0.05 0.13 64.29 0 0 1.00 AT EAVE 0.06 0.05 0.07 35.71 0 1.00 TOTAL (MIN)0.09 0.09 0.19 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 07/12/18 Mike Sheeks