HomeMy WebLinkAbouta00702 DOOR JAMB @ HORIZONTAL SIDING SCALE: PLAN DETAIL HORIZONTAL SIDING, TYPICAL J-CHANNEL TRIM, TYPICAL 1x TRIM SURROUND - REFER TO ELEVATIONS LINE OF THRESHOLD BELOW ENTRY DOOR WITH FACTORY APPLIED BRICK MOULD CAULK CONTINUOUS OUTSIDE & BEHIND BRICK MOULD - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR DOOR OPN'G. 05 DOOR JAMB @ MASONRY VENEER SCALE: PLAN DETAIL CAULK, CONTINUOUS LINE OF THRESHOLD BELOW LINE OF CONCRETE STEP BELOW ENTRY DOOR WITH FACTORY APPLIED BRICK MOULD CAULK CONTINUOUS OUTSIDE & BEHIND BRICK MOULD - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR DOOR OPN'G NOTE: REFER TO TYPICAL WALL SECTIONS AND GENERAL NOTES FOR BRICK TIE REQUIREMENTS. MASONRY VENEER, TYP. - BRICK SHOWN, STONE SIM. 10DOOR HEAD WITH WOOD TRIM PANEL ABOVE SCALE: 3" = 1'-0" 08 SCALE: DOOR JAMB WITH WOOD TRIM PLAN DETAIL CAULK, CONTINUOUS MASONRY VENEER, TYPICAL LINE OF THRESHOLD BELOW LINE OF CONCRETE STOOP BELOW 1x TRIM OVER P.T. 5/4 BACK-UP - REFER TO ELEVATIONS ENTRY DOOR WITH FACTORY APPLIED BRICK MOULD CAULK CONTINUOUS OUTSIDE & BEHIND BRICK MOULD - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR DOOR OPN'G 11 DOOR HEAD @ COVERED PORCH SCALE: ENTRY DOOR WITH FACTORY APPLIED BRICK MOULD CAULK CONTINUOUS OUTSIDE & BEHIND BRICK MOULD - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR DOOR OPN'G. BRICK BEYOND 2x CEILING RAFTER - REFER TO PLANS & SECTIONS 06 DOOR THRESHOLD @ BRICK VENEER SCALE: 8" THICK CAST-IN-PLACE CONCRETE FOUNDATION WALL - UNLESS NOTED OTHERWISE ON FOUNDATION PLAN CAULK, CONTINUOUS DOOR JAMB BEYOND 5/8x4 BLOCKING, TYPICAL BRICK ROWLOCK SILL - SLOPE 1/4" - HOLD 1/4" BELOW THRESHOLD, TYP. FINISH FLOORING SHOWN DASHED - REFER TO PLANS BRICK VENEER BEYOND 'FLASH & SEAL' FLASHING 6" 1/2" FIBER EXPANSION BOARD, TYPICAL CONC. HAUNCH BEYOND REFER TO FOUNDATION PLANS ALUMINUM PAN - SET IN 3 BEADS OF CAULK 12 MASONRY VENEER w/ DECORATIVE SURROUND SCALE: 8" THICK CAST-IN-PLACE CONCRETE FOUNDATION WALL - UNLESS NOTED OTHERWISE ON FOUNDATION PLAN 1x6 TRIM OVER P.T. 1x BLOCKING - HOLD 1/4" BELOW THRESHOLD - HOLD 1/4" OFF T/ PORCH SLAB - w/ 45° BEVEL @ TOP FLASH & SEAL' FLASHING 6" CAULK, CONTINUOUS SYNTHETIC DECORATIVE DOOR SURROUND BEYOND -REFER TO ELEV'S DOOR THRESHOLD CONC. HAUNCH BEYOND REFER TO FOUNDATION PLANS CAULK, CONTINUOUS DOOR JAMB BEYOND FINISH FLOORING SHOWN DASHED - REFER TO PLANS BRICK VENEER BEYOND 5/8x4 BLOCKING, TYPICAL ALUMINUM PAN - SET IN 3 BEADS OF CAULK DOOR HEAD @ HORIZONTAL SIDING01 SCALE: HORIZONTAL SIDING, TYPICAL STRUCTURAL SHEATHING, TYPICAL ENTRY DOOR WITH FACTORY APPLIED BRICK MOULD OVERLAP STRUCTURAL SHEATHING 2" @ TOP PLATE TYPICAL 1x TRIM, TYPICAL - REFER TO ELEVATIONS J-CHANNEL TRIM, TYPICAL CAULK CONTINUOUS OUTSIDE & BEHIND BRICK MOULD - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR DOOR OPN'G 24" POLY FLASHING @ BAND BOARD, TYPICAL BREAK MTL DRIP EDGE FLASH'G - NAIL & CAULK T/ FLASHING TO WALL SHEATHING, TYPICAL - EXTEND FLASH'G 1/2"± BEYOND OUTSIDE EDGE OF BRICK MOULD - SUPPLIED & INSTALLED BY DOOR INSTALLER. 5/16" HARDIPANEL - SMOOTH FINISH, TYPICAL - HOLD 1/4" OFF BRICK MOULD 1x TRIM, TYPICAL - HOLD TRIM 1/16" OFF BRICK MOULD - REFER TO ELEVATIONS FOR SIZES AND PROFILES VENEER BEYOND - REFER TO ELEVATIONS, (BRICK SHOWN) BREAK MTL DRIP EDGE FLASH'G - NAIL & CAULK T/ FLASHING TO WALL SHEATHING, TYPICAL - EXTEND FLASH'G 1/2"± BEYOND OUTSIDE EDGE OF BRICK MOULD - SUPPLIED & INSTALLED BY DOOR INSTALLER ENTRY DOOR WITH FACTORY APPLIED BRICK MOULD CAULK CONTINUOUS OUTSIDE & BEHIND BRICK MOULD - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR DOOR OPN'G 1x TRIM, TYPICAL - w/ 30° BEVEL @ TOP EDGE - HOLD TRIM 1/16" OFF BRICK MOULD - REFER TO ELEVATIONS FOR SIZES AND PROFILES PVC MOULDING, TYPICAL - REFER TO ELEVATIONS FOR SIZE AND LOCATION 3" = 1'-0" 3" = 1'-0" 3" = 1'-0"3" = 1'-0" 3" = 1'-0" 3" = 1'-0" 3" = 1'-0" 03 DOOR THRESHOLD @ SIDING / CULTURED STONE SCALE: 3" = 1'-0" 8" THICK CAST-IN-PLACE CONCRETE FOUNDATION WALL - UNLESS NOTED OTHERWISE ON FOUNDATION PLAN CAULK, CONTINUOUS DOOR JAMB BEYOND 1x6 TRIM, TYPICAL - HOLD 14" BELOW THRESHOLD - HOLD 14" OFF T/ PORCH SLAB FINISH FLOORING SHOWN DASHED - REFER TO PLANS 6" CAULK, CONTINUOUS CONC. HAUNCH BEYOND REFER TO FOUNDATION PLANS STRUCTURAL SHEATHING - EXTEND SHEATHING TO 12" BELOW T/ FDN WALL - w/ POLY EXTENDED 1" BELOW T/ FOUNDATION 5/8 x 4 BLOCKING, TYPICAL ALUMINUM PAN - SET IN 3 BEADS OF CAULK 'FLASH & SEAL' FLASHING METAL DRIP - NAIL & TAPE TO SHEATHING - USE 1" ROOFING NAILS @ EA. STUD 07 SCALE: 3" = 1'-0" DOOR HEAD WITH WOOD TRIM STEEL LINTEL, TYPICAL - RE: GENERAL NOTES FOR SIZE & BEARING REQUIREMENTS CAULK, CONTINUOUS 1x TRIM OVER P.T. 5/4 BACK-UP - REFER TO ELEVATIONS BREAK MTL DRIP EDGE FLASH'G - NAIL & CAULK T/ FLASHING TO WALL SHEATHING, TYPICAL - EXTEND FLASH'G 1/2"“ BEYOND OUTSIDE EDGE OF BRICK MOULD - SUPPLIED & INSTALLED BY DOOR INSTALLER ENTRY DOOR WITH FACTORY APPLIED BRICK MOULD CAULK CONTINUOUS OUTSIDE & BEHIND BRICK MOULD - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR DOOR OPN'G MASONRY VENEER MASONRY VENEER, TYP. - BRICK SHOWN, STONE SIM 18" MYLAR FLASHING -EXTEND 8" BEYOND EA. SIDE OF DOOR -NAIL & CAULK T/ FLASH'G TO SHEATHING, TYP. BRICK WEEPHOLES, TYPICAL -ANGLE UP FROM BTM OF SOLDIER -2'-0" o.c. & AT EA. SIDE OF OPN'G -KEEP WEEPS TO MINIMUM (3/16") 04 SCALE: 3" = 1'-0" DOOR HEAD @ MASONRY VENEER STEEL LINTEL, TYPICAL - RE: GENERAL NOTES FOR SIZE & BEARING REQUIREMENTS ENTRY DOOR WITH FACTORY APPLIED BRICK MOULD CAULK CONTINUOUS OUTSIDE & BEHIND BRICK MOULD - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR DOOR OPN'G MASONRY VENEER, TYP. - BRICK SHOWN, STONE SIM NOTE: 7/8"“ AIR SPACE @ BRICK VENEER, TYPICAL GROUT SOLID W/ 15# FELT OR OTHER APPROVED WEATHER-RESISTANT MATERIAL @ STONE VENEER ONLY, TYPICAL 09 ARCHED DOOR HEAD @ BRICK VENEER SCALE: 3" = 1'-0" MASONRY VENEER, TYPICAL CAULK, CONTINUOUS 1x TRIM OVER P.T. 5/4 BACK-UP - REFER TO ELEVATIONS ARCHED BRICK HEADER - BRICK SHOWN, STONE SIM BREAK MTL DRIP EDGE FLASH'G - NAIL & CAULK T/ FLASHING TO WALL SHEATHING, TYPICAL - EXTEND FLASH'G 1/2"“ BEYOND OUTSIDE EDGE OF BRICK MOULD - SUPPLIED & INSTALLED BY DOOR INSTALLER ENTRY DOOR WITH FACTORY APPLIED BRICK MOULD CAULK CONTINUOUS OUTSIDE & BEHIND BRICK MOULD - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR DOOR OPN'G 18" MYLAR FLASHING -EXTEND 8" BEYOND EA. SIDE OF DOOR -NAIL & CAULK T/ FLASH'G TO SHEATHING, TYP. BRICK WEEPHOLES, TYPICAL -ANGLE UP FROM BTM OF SOLDIER -2'-0" o.c. & AT EA. SIDE OF OPN'G -KEEP WEEPS TO MINIMUM (3/16") BREAK MTL DRIP EDGE FLASH'G - NAIL & CAULK T/ FLASHING TO WALL SHEATHING, TYPICAL - EXTEND FLASH'G 1/2"“ BEYOND OUTSIDE EDGE OF BRICK MOULD - SUPPLIED & INSTALLED BY DOOR INSTALLER 18" MYLAR FLASHING -EXTEND 8" BEYOND EA. SIDE OF DOOR -NAIL & CAULK T/ FLASH'G TO SHEATHING, TYP. BRICK WEEPHOLES, TYPICAL -ANGLE UP FROM BTM OF SOLDIER -2'-0" o.c. & AT EA. SIDE OF OPN'G -KEEP WEEPS TO MINIMUM (3/16") W I L L I A M L . K A U F H O L Z A R C H I T E C T T A L L Y N S RI D G E RE A S O N FO R PL O T : PL O T DA T E : Job No. Sheet No. IN HO M E S I T E N O . OF F I C E R E V I E W : M A S T E R BY : DA T E : C DA T E : 39 4 0 OL Y M P I C B L V D E R L A N G E R , KY 41 0 1 8 PH : (8 5 9 ) 34 1 - 4 7 0 9 F I E L D SP E C HO T L I N E : (8 5 9 ) 34 1 - 4 7 0 9 CO P Y R I G H T A L L RI G H T S R E S E R V E D F I S C H E R HO M E S , In c . JO B IN F O : DA T E : P E R M I T : S I G N -O F F : CO N S T R U C T I O N : RE V I S I O N : RE V I S I O N : RE V I S I O N : RE V I S I O N : HO M E TY P E : PL A N : 6/ 2 9 / 2 0 1 8 2: 1 2 PM # TLR010190000 T L R 0 1 0 1 9 0 0 0 0 * M A R K E T HO M E * 1 4 4 0 4 TR A H A N DR I V E C L A Y T O N 54 - 3 7 0 - C L A Y T O N FR E N C H MA N O R WI T H BR I C K C A R M E L , IN 1 9 0 5 /2 0 1 7 MP -- - - -- - - -- - - 6 -2 7 -1 8 -- - - 6 -2 9 -1 8 -- - - -- - - -- - - -- - - -- - - -- - - fi e l d s p e c c h a n g e @ f i s c h e r h o m e s . c o m R E V I S E D BY : -- - - -- - - -- - - S A P P H I R E T R A D E S U P P O R T s a p p h i r e t r a d e p a r t n e r s @ f i s c h e r h o m e s .c o m Fi s c h e r Ho m e s In d i a n a p o l i s II , LL C f /k /a Fi s c h e r Ho m e s In d i a n a p o l i s II , L. P . D1.1 07/24/18 William Hohlt