HomeMy WebLinkAbouta010 @ FIBER CEMENT BOARD PANEL
SCALE:
'SONOLASTIC NP-1' CAULK OVER ALL
NAIL HOLES AND OUTSIDE EDGE OF
NAILING FLANGE.
- SMOOTH w/ APPLICATOR
- INSTALL IN SUCH A MANNER SO AS TO
PREVENT MOISTURE FROM ENTERING
THE TOP & SIDES OF THE EXTERIOR
WINDOW OPN'G.
06 3" = 1'-0"
STRUCTURAL SHEATHING, TYPICAL
FIBER CEMENT BOARD PANEL, TYPICAL
1x TRIM, TYPICAL
- w/ 10° BEVEL @ TOP EDGE
- w/ FIBER CEMENT BOARD PANEL
BACK-UP
- REFER TO ELEVATIONS FOR SIZES
AND PROFILES
@ FIBER CEMENT BOARD PANEL
14" BEAD OF 'SONOLASTIC NP-1'
CAULK, CONT. BTWN FLANGE AND
SHEATHING
- TYPICAL, ALL (4) SIDES
SCALE:05 3" = 1'-0"
STRUCTURAL SHEATHING, TYPICAL
FIBER CEMENT BOARD PANEL, TYPICAL
@ FIBER CEMENT BOARD PANEL
'SONOLASTIC NP-1' CAULK OVER ALL
NAIL HOLES AND OUTSIDE EDGE OF
NAILING FLANGE
- SMOOTH w/ APPLICATOR
- INSTALL IN SUCH A MANNER SO AS TO
PREVENT MOISTURE FROM ENTERING
THE TOP & SIDES OF THE EXTERIOR
WINDOW OPN'G
1x TRIM, TYPICAL
- w/ FIBER CEMENT BOARD PANEL
BACK-UP
- REFER TO ELEVATIONS FOR SIZES
AND PROFILES
PLAN DETAIL - WINDOW JAMB w/ WOOD TRIM
FIBER CEMENT BOARD PANEL, TYPICAL
SCALE:08 3" = 1'-0"
'SONOLASTIC NP-1' CAULK OVER ALL
NAIL HOLES AND OUTSIDE EDGE OF
NAILING FLANGE
- SMOOTH w/ APPLICATOR
- INSTALL IN SUCH A MANNER SO AS TO
PREVENT MOISTURE FROM ENTERING
THE TOP & SIDES OF THE EXTERIOR
WINDOW OPN'G
@ FIBER CEMENT BOARD PANEL
FIBER CEMENT BOARD PANEL, TYPICAL
SCALE: 09 3" = 1'-0"
1x4 CORNER TRIM
- OVER FIBER CEMENT BOARD PANEL
FIBER CEMENT BOARD PANEL
- EXTEND TO CORNER
FRONT ELEVATION
SCALE:
w/ FIBER CEMENT BOARD PANEL
3" = 1'-0"
PLAN DETAIL - 1x4 TRIM @ CORNER SECTION - WINDOW SILL w/ WOOD TRIM SECTION - WINDOW HEAD w/ SLOPED WOOD TRIM
SECTION - WINDOW HEAD w/ WOOD TRIM
@ GABLE END w/ LAPPED 1x8 RAKE BOARDS
SECTION - FIBER CEMENT BOARD PANEL
07 SCALE: 3" = 1'-0"
1x8 RAKE BOARD
- w/ 1x6 BACK-UP
1x8 FRIEZE BOARD
- w/ FIBER CEMENT BOARD PANEL
BACK-UP
FIBER CEMENT BOARD PANEL, TYPICAL
STRUCTURAL SHEATHING
(STRUCTURAL & WATER REPELLENT)
-GABLE SHT'G TO OVERLAP WALL
SHT'G 2" MINIMUM.
1 8 "
MA
X
.
@ VERTICAL SEAM - GABLE END
SCALE:
SECTION - FIBER CEMENT BOARD PANEL
6" = 1'-0"
- 2x4 FLATS @ 16" o.c.
GABLE END TRUSS
1x BATTEN
- REFER TO ELEVATIONS FOR
SIZES AND PROFILES
NOTE:
ALWAYS PROVIDE STUD DIRECTLY
BEHIND BATTEN / BUTT JOINT
1 8 "
MA
X
.
@ VERTICAL SEAM
SCALE:
SECTION - FIBER CEMENT BOARD PANEL
6" = 1'-0"
FRAME WALL @ 16" o.c.
1x BATTEN
- REFER TO ELEVATIONS FOR
SIZES AND PROFILES
FIBER CEMENT BOARD PANEL, TYPICAL
- MAX. 18" GAP @ SEAMS
NAILING PATTERN NOTE:
2" x 6d GALVANIZED NAILS TO BE 6" o.c. ON
PERIMETER and 12" o.c. IN THE FIELD
- KEEP FASTENERS 2" AWAY FROM CORNERS
& 38" MIN. FROM EDGE OF PANEL
'H' STRIP CONNECTOR
FIBER CEMENT BOARD PANEL, TYPICAL
FRAME WALL @ 16" o.c.
6" = 1'-0"
SECTION - FIBER CEMENT BOARD PANEL
SCALE:
@ VERTICAL SEAM
12
01
02
03
18" STRUCTURAL SHEATHING
18" STRUCTURAL
SHEATHING
18" STRUCTURAL SHEATHING
FIBER CEMENT BOARD PANEL, TYPICAL
- MAX. 18" GAP @ SEAMS
1x TRIM, TYPICAL
- w/ 10° BEVEL @ TOP EDGE
- w/ FIBER CEMENT BOARD PANEL
BACK-UP
- REFER TO ELEVATIONS FOR SIZES
AND PROFILES
112" NAIL @ EVERY OTHER NAILING HOLE
IN WINDOW FLANGE
- NAIL HEAD TO BE WIDER THAN HOLE IN
FLANGE
14" BEAD OF 'SONOLASTIC NP-1'
CAULK, CONT. BTWN FLANGE AND
SHEATHING
- TYPICAL, ALL (4) SIDES
112" NAIL @ EVERY OTHER NAILING HOLE
IN WINDOW FLANGE
- NAIL HEAD TO BE WIDER THAN HOLE IN
FLANGE
14" BEAD OF 'SONOLASTIC NP-1'
CAULK, CONT. BTWN FLANGE AND
SHEATHING
- TYPICAL, ALL (4) SIDES
14" BEAD OF 'SONOLASTIC NP-1'
CAULK, CONT. BTWN FLANGE AND
SHEATHING
- TYPICAL, ALL (4) SIDES
112" NAIL @ EVERY OTHER NAILING HOLE
IN WINDOW FLANGE
- NAIL HEAD TO BE WIDER THAN HOLE IN
FLANGE
1x TRIM, TYPICAL
- w/ 10° BEVEL @ TOP EDGE
- w/ FIBER CEMENT BOARD PANEL
BACK-UP
- REFER TO ELEVATIONS FOR SIZES
AND PROFILES
BREAK MTL DRIP EDGE FLASH'G
- NAIL & CAULK T/ FLASHING TO WALL
SHEATHING, TYPICAL
- EXTEND FLASH'G 1/2" BEYOND
OUTSIDE EDGE OF WINDOW
'SONOLASTIC NP-1' CAULK OVER ALL
NAIL HOLES AND OUTSIDE EDGE OF
NAILING FLANGE
- SMOOTH w/ APPLICATOR
- INSTALL IN SUCH A MANNER SO AS TO
PREVENT MOISTURE FROM ENTERING
THE TOP & SIDES OF THE EXTERIOR
WINDOW OPN'G
112" NAIL @ EVERY OTHER NAILING HOLE
IN WINDOW FLANGE
- NAIL HEAD TO BE WIDER THAN HOLE IN
FLANGE
BREAK MTL DRIP EDGE FLASH'G
- NAIL & CAULK T/ FLASHING TO WALL
SHEATHING, TYPICAL
- EXTEND FLASH'G 1/2" BEYOND
OUTSIDE EDGE OF WINDOW
APPROVED ANCHORS @ 3"o.c., TYPICAL
APPROVED FASTENER
@ 3"o.c., TYPICAL
STRUCTURAL SHEATHING, TYPICAL
112" NAIL @ EVERY OTHER NAILING HOLE
IN WINDOW FLANGE
- NAIL HEAD TO BE WIDER THAN HOLE IN
FLANGE
NOTE:
WINDOW NAILING FLANGE MUST
HAVE A CONTINUOUS LAP OF
1-1/8" OVER THE SHEATHING, TYP.
14" BEAD OF 'SONOLASTIC NP-1' CAULK,
CONT. BTWN FLANGE AND SHEATHING
- TYPICAL, ALL (4) SIDES
'SONOLASTIC NP-1' CAULK OVER ALL
NAIL HOLES AND OUTSIDE EDGE OF
NAILING FLANGE
- SMOOTH w/ APPLICATOR
- INSTALL IN SUCH A MANNER SO AS TO
PREVENT MOISTURE FROM ENTERING
THE TOP & SIDES OF THE EXTERIOR
WINDOW OPN'G
HARDBOARD FRIEZE
- TRIM TO MATCH WINDOW HEADER HEIGHTS
- REFER TO ELEVATIONS FOR SIZES AND PROFILES
- w/ FIBER CEMENT BOARD PANEL BACK-UP
w/ FIBER CEMENT BOARD PANEL
SCALE: 04 3" = 1'-0"
SECTION - WINDOW HEAD @ FRIEZE BOARD
@ BAND BOARD TRIM w/ SIDING BELOW
PLAN DETAIL - FIBER CEMENT BOARD PANEL
SCALE:11 3" = 1'-0"
@ BAND BOARD TRIM w/ TRIM BELOW
SECTION - FIBER CEMENT BOARD PANEL
10 SCALE: 3" = 1'-0"
1x TRIM BOARD
- REFER TO ELEVATIONS FOR SIZES AND
PROFILES
- w/ FIBER CEMENT BOARD PANEL BACK-UP
FIBER CEMENT BOARD PANEL, TYPICAL
- HOLD OFF T/ TRIM 14"
METAL DRIP FLASHING
- NAIL & TAPE TO SHEATHING
- USE 1" ROOFING NAILS @ EA. STUD
1 4 "
1x TRIM BOARD
- REFER TO ELEVATIONS FOR SIZES AND
PROFILES
FIBER CEMENT BOARD PANEL, TYPICAL
- HOLD OFF T/ TRIM 14"
METAL DRIP FLASHING
- NAIL & TAPE TO SHEATHING
- USE 1" ROOFING NAILS @ EA. STUD
1 4 "
HORIZONTAL SIDING, TYPICAL
J-CHANNEL TRIM, TYPICAL
STRUCTURAL SHEATHING, TYPICAL
FIBER CEMENT BOARD PANEL, TYPICAL
1x TRIM BOARD (SHOWN BEYOND)
- REFER TO ELEVATIONS FOR SIZES AND PROFILES
- w/ FIBER CEMENT BOARD PANEL BACK-UP
STRUCTURAL SHEATHING, TYPICAL
NAILING PATTERN NOTE:
2" x 6d GALVANIZED NAILS TO BE 6" o.c. ON
PERIMETER and 12" o.c. IN THE FIELD
- KEEP FASTENERS 2" AWAY FROM CORNERS
& 38" MIN. FROM EDGE OF PANEL
NAILING PATTERN NOTE:
2" x 6d GALVANIZED NAILS TO BE 6" o.c. ON
PERIMETER and 12" o.c. IN THE FIELD
- KEEP FASTENERS 2" AWAY FROM CORNERS
& 38" MIN. FROM EDGE OF PANEL
NOTE:
ALWAYS PROVIDE STUD DIRECTLY
BEHIND PANEL JOINT / 'H' STRIP
CONNECTOR
NOTE:
ALWAYS PROVIDE STUD DIRECTLY
BEHIND BATTEN / BUTT JOINT
1x2 SYNBOARD TRIM
- EXTEND 1" BEYOND 1x BEVELED TRIM
W
I
L
L
I
A
M L .
K A U F H O L Z
A R C H I T E C
T
T A L L Y N S RI
D
G
E
RE
A
S
O
N
FO
R
PL
O
T
:
PL
O
T
DA
T
E
:
Job No.
Sheet No.
IN
HO
M
E
S
I
T
E
N O .
OF
F
I
C
E
R E V I E W :
MA
S
T
E
R
BY
:
DA
T
E
:
C
DA
T
E
:
39
4
0
OL
Y
M
P
I
C
B L V D E R L A N G E R , KY
41
0
1
8
PH
:
(8
5
9
)
34
1
-
4
7
0
9
F I E L D SP
E
C
HO
T
L
I
N
E
:
(8
5
9
)
34
1
-
4
7
0
9
CO
P
Y
R
I
G
H
T
A L L RI
G
H
T
S
R E S E R V E D
FI
S
C
H
E
R
HO
M
E
S
,
In
c
.
JO
B
IN
F
O
:
DA
T
E
:
P E R M I T :
S I G N -O F F :
CO
N
S
T
R
U
C
T
I
O
N
:
RE
V
I
S
I
O
N
:
R E V I S I O N :
RE
V
I
S
I
O
N
:
RE
V
I
S
I
O
N
:
HO
M
E
TY
P
E
:
PL
A
N
:
6/
2
9
/
2
0
1
8
2:
1
3
PM
#
TLR010190000
T L R 0 1 0 1 9 0 0 0 0 * M A R K E T HO
M
E
*
1 4 4 0 4 TR
A
H
A
N
DR
I
V
E
C L A Y T O N
54
-
3
7
0
-
C
L
A
Y
T
O
N
FR
E
N
C
H
MA
N
O
R
WI
T
H
BR
I
C
K
C A R M E L , IN
1 9
0 5 /2 0 1 7
MP
--
-
-
--
-
-
--
-
-
6 -2 7 -1 8
--
-
-
6 -2 9 -1 8
--
-
-
--
-
-
--
-
-
--
-
-
--
-
-
--
-
-
fi
e
l
d
s
p
e
c
c
h
a
n
g
e
@
f
i
s
c
h
e
r
h
o
m
e
s
.
c
o
m
RE
V
I
S
E
D
BY
:
--
-
-
--
-
-
--
-
-
S A P P H I R E T R A D E SU
P
P
O
R
T
s a p p h i r e t r a d e p a r t n e r s @ f i s c h e r h o m e s .c o m
Fi
s
c
h
e
r
Ho
m
e
s
In
d
i
a
n
a
p
o
l
i
s
II
,
L L C f /k /a
Fi
s
c
h
e
r
Ho
m
e
s
In
d
i
a
n
a
p
o
l
i
s
II
,
L.
P
.
D1.4
07/24/18
William Hohlt