HomeMy WebLinkAbouts002FLOOR SYSTEM PER PRINT 34" T&G SHEATHING R-19 INSULATION ZIP BOARD SHEATHING 2x4 WALLS = R-13 INSULATION 2x6 WALLS = R-19 INSULATION 12" DRYWALL 2x4 OR 2x6 DOUBLE TOP PLATE 2x4 OR 2x6 SILL INSULATION BAFFLE R-38 INSULATION OR BETTER COMPOSITE SHINGLES 716" SHEATHING GUTTER 1'-0" 15# FELT PRE-ENGINEERED TRUSSES 1x6 FASCIA VINYL VENTED SOFFIT BLOCK FOR SOFFIT FRIEZE PER ELEVATION 2x4 OR 2x6 DOUBLE TOP PLATE SCALE: 1 2- STORY WALL SECTION - BASEMENT 1" = 1'-0" POURED WALL - FULL SIDING INSULATION BAFFLE R-38 INSULATION OR BETTER COMPOSITE SHINGLES 716" SHEATHING GUTTER 1'-0" 15# FELT PRE-ENGINEERED TRUSSES 1x6 FASCIA VINYL VENTED SOFFIT BLOCK FOR SOFFIT FRIEZE PER ELEVATION BLOCKING 2x4 OR 2x6 DOUBLE TOP PLATE INSULATION BAFFLE R-38 INSULATION OR BETTER COMPOSITE SHINGLES 716" SHEATHING GUTTER 1'-0" 15# FELT PRE-ENGINEERED TRUSSES 1x6 FASCIA VINYL VENTED SOFFIT BLOCK FOR SOFFIT FRIEZE PER ELEVATION 2x4 OR 2x6 DOUBLE TOP PLATE SILL TO BE A MINIMUM OF 15° SLOPE (BRICK OR STONE) BRICK VENEER ALUMINUM COIL FLASHING TUCKED AND TAPED UNDER HOUSE WRAP T/O WAINSCOT PER PLAN 1 D1.1 SCALE: 3 RANCH WALL SECTION - BASEMENT 1" = 1'-0" POURED WALL - FULL BRICK SCALE: 2 RANCH WALL SECTION - BASEMENT 1" = 1'-0" POURED WALL - BRICK WAINSCOT 12"Ø 'TITEN' BOLT OR EQUIV. OR MAB-15 STRAP OR EQUIV. FLOOR SYSTEM PER PRINT 2x4 P.T. SILL - w/ SILL SEALER 34" T&G SHEATHING R-19 INSULATION ZIP BOARD SHEATHING R-11 DRAPED INSULATION - TOP 4'-0" OF WALL (MIN. 30" BELOW GRADE) GRADE - MAY VARY 8" MIN . 2x4 OR 2x6 SILL 2x4 WALLS = R-13 INSULATION 2x6 WALLS = R-19 INSULATION 12"Ø 'TITEN' BOLT OR EQUIV. OR MAB-15 STRAP FLOOR SYSTEM PER PRINT 2x4 P.T. SILL - w/ SILL SEALER 34" T&G SHEATHING R-19 INSULATION ZIP BOARD SHEATHING R-11 DRAPED INSULATION - TOP 4'-0" OF WALL (MIN. 30" BELOW GRADE) GRADE - MAY VARY 8" MIN . 2x4 OR 2x6 SILL WEEP HOLES @ 33"o.c. MAX. FLASHING PER SPECS 2x4 WALLS = R-13 INSULATION 2x6 WALLS = R-19 INSULATION 12"Ø 'TITEN' BOLT OR EQUIV. OR MAB-15 STRAP FLOOR SYSTEM PER PRINT 2x4 P.T. SILL - w/ SILL SEALER 34" T&G SHEATHING R-19 INSULATION ZIP BOARD SHEATHING R-11 DRAPED INSULATION - TOP 4'-0" OF WALL (MIN. 30" BELOW GRADE) GRADE - MAY VARY 8" MIN . 2x4 OR 2x6 SILL WEEP HOLES @ 33"o.c. MAX. FLASHING PER SPECS 2x4 WALLS = R-13 INSULATION 2x6 WALLS = R-19 INSULATION 8" CONCRETE FOUNDATION 12" GRAVEL FILL MIN. 3" Ø PERFORATED DRAIN TILE 312" CONCRETE SLAB 4" GRAVEL FILL 8"x16" CONCRETE FOOTING FELT FLASHING 6 MIL VAPOR BARRIER 8" CONCRETE FOUNDATION 12" GRAVEL FILL MIN. 3" Ø PERFORATED DRAIN TILE 312" CONCRETE SLAB 4" GRAVEL FILL 8"x16" CONCRETE FOOTING FELT FLASHING 6 MIL VAPOR BARRIER 8" CONCRETE FOUNDATION 12" GRAVEL FILL MIN. 3" Ø PERFORATED DRAIN TILE 312" CONCRETE SLAB 4" GRAVEL FILL 8"x16" CONCRETE FOOTING FELT FLASHING 6 MIL VAPOR BARRIER Sheet: Issued Date: Sheet Title : LSP Date: BASE PLAN REVISION: 11 x 1 7 P R I N T S A R E 1 2 S C A L E LSP By: LSP Rev: 5 6 Job #: 04-19-16 8/25/17 11/6/17 1/24/18 3/22/18 Cl a y t o n II 7 8 10 4 7 Se r e n i t y Ct Bo n b a r pr 06-19-18 ---- M/ I H o m e s I n c . M/I H O M E S PR E S T I G E SE R I E S 20 1 6 © BB-28 M/ I H o m e s I n d i a n a p o l i s R e g i o n Ar c h i t e c t u r e D e p a r t m e n t 84 2 5 W o o d f i e l d C r o s s i n g B l v d . In d i a n a p o l i s , I N 4 6 2 4 0 Ph 3 1 7 . 2 5 5 . 9 9 0 0 D4.7 BASEMENT WALL SECTIONS - POURED - RANCH 07/26/18 William Hohlt