Loading...
HomeMy WebLinkAboutGN 2 COVER SHEETSh e e t In f o r m a t i o n Copyright © 2017, (2017) The Drees Company. All Rights Reserved. 211 GRANDVIEW DRIVE, FORT MITCHELL, KY 41017 PHONE: [859] 578-4200 RESIDENCE FOR: House Name: Series: Plan No.: Job Number: Drawing Date: Coord Name: Coord Phone: Drawing Scale: 1/8" = 1'0" Drawn By: 0C.1 WENINGER 14305 DUFTON COURT ALBANY PLACE ALB-0042-00 06/25/2018 MELISSA P. SERIES_NM PLAN_NM 859-578-4290 the CRESTWOOD SSP Elevation "C" Cover Sheet Index to the Drawings Sheet No. Sheet Name 0C.1 Cover Sheet 0N.1 General Notes 0P.1 Plot Plan 1.01 Foundation Plan 1.02 Lower Level Framing Plan 1.03 Lower Level Mechanical Plan 2.01F First Floor Framing Plan 2.01S First Floor Structural Plan 2.02F Second Floor Framing Plan 2.02S Second Floor Structural Plan 2.04 Roof Plan 3.01 First Floor Subfloor Plan 3.02 Second Floor Subfloor Plan 4.01 First Floor Mechanical Plan 4.02 Second Floor Mechanical Plan 5.01 Building Sections 6.01 Front Elevation 6.02 Garage Side Elevation 6.03 Rear Elevation 6.04 Side Elevation 7.01 House Specific Details 7.02 House Specific Details 7.03 House Specific Details Division: INDIANAPOLIS Building Code: 2005 INDIANA RESIDENTIAL CODE Redraws Plan Review: 07/10/2018 1) PULLED EXERCISE ROOM & MECHANICAL EQUIPMENT 5' 2) ADDED 4040 EGRESS WITH METAL WELL TO EXERCISE ROOM 3) CONVERTED FLUSH MOUNT LIGHTS IN FINISH BASEMENT & FRONT PORCH TO CAN LIGHTS 4) SWAPPED DOOR/WINDOW LOCATIONS AT FLEX ROOM 5) ADDED TRANSOM ABOVE WINDOW AT FLEX ROOM 6) MOVED POCKET DOOR AT FLEX ROOM 7) CONVERTED RANGE TO COOKTOP 8) ADDED CAN LIGHT AT MASTER SHOWER 9) CHANGED DOOR SWING AT POWDER ROOM Plan Review: XX/XX/XX Xxxxx Customer Plan Review Signature I understand that my new Drees home will be built in general comformance to the plans, specifications, selections and the Purchase Agreement, all of which I have reviewed and approved. This set of plans may not reflect the elevations or options for my house. Drees draws the standard plans complete with the most common options. The subcontractor's sets will show only the options I selected in my selection sheets. I have reviewed the plot plan for my house and understand that there may be some field adjustments as to the exact location of the house on the lot. I further understand that my home will not be built exactly like any other Drees home or Model and that some minor variations from my plans and specifications may occur since every home that is built has it's own set of unique construction problems that must be dealt with as the home is being built. Customer: ______________________________________________ Date: _____________ Customer: ______________________________________________ Date: _____________ Building Height: As Required Brick Calculations: Sheet X.XX Fenestration Calculations: Total Wall Square Footage: ________ Total Window Square Footage: ________ Total Fenestration %: ________ Square Footage Living Areas 1st Floor 2746 SF 2nd Floor 1128 SF Finished Basement 1453 SF 5327 SF Unfinished Areas Crawl Space 501 SF Front Covered Porch 128 SF Garage 697 SF Rear Covered Porch 310 SF Unfinished Basement 786 SF 2422 SF Square Footage total may vary by +1 SF due to automated rounding of first and second floor area Architecture Plan Review: No Comments Items drawn on any drawings and not written in the contract selctions WILL NOT be included in the site specific drawings.See Comments Customer Request: Design Solution: Reason For Modification: Comments: 4. XXX 3. XXX 4. XXX 3. XXX 4. XXX 3. XXX 4. XXX 3. XXX 2. "8' HOLLOW CORE INTERIOR DOORS STANDARD LOCATION" 1. (1)"GAS LINE TO EXTERIOR STUB-OUT AT WALL" 2. NOT SHOWN 1. NOT SHOWN 2. LOCATION NOT PROVIDED 1. LOCATION NOT PROVIDED 2. 1. N/A N/A 07/30/18 Mike Sheeks