Loading...
HomeMy WebLinkAbout154IL� F m J B \ O co 00 . W > ID J ¢ ¢ (n J U W LnH O N f as U J IL m U H F- J C7 D_ Q / o mow oaaa f / / N ..UN N W W N W W U J (n mHm UI:3Ja /a I - Z r// co m U1 O 00 O O mm ¢ ¢ Q U O O / ZZ f ¢ Q mal I- tn N f \ N W W l9 U U / m¢a Baa Y N N LO nj Y Y XX mx N / / U1 \ J J W COmW W J W Z > m O a fuj ooLlil aIZa O .. O J (n EL Z) 199-10 FOOTING NOTES: SOIL SEARING PRESSURE USED IN DESIGN 15 1,500 P5F AT WALL SPREAD FOOTINGS E THICKENED SLABS. UNSUITABLE SOILS WERE ENCOUNTERED ON SITE PER PRELIMINARY 501L INVESTIGATIVE REPORT OF JUNE 11, 2004 BY ALT F WITZIG ENGINEERING, INC. UNDERCUTTING a SOIL INPROVEMENT 5" AS COMPACTED STRUCTURAL FILL OR LEAN CONCRETE WILL BE REQUIRED IN AREAS WHERE UNSUITABLE SOILS ARE ENCOUNTERED PURRING EXCAVATION, PROVIDE PROPER CUT, FILL, F COMPACTION OF SOILS PER GEOTECHNICAL ENGINEER'S RECOMMENDATIONS. ALL FOUNDATION EXCAVATIONS SHALL BE INSPECTED BY A QUALIFIED GEOTECHNICAL ENGINEER PRIOR TO RACING CONCRETE TO ENSURE THE ALLOWABLE SOIL BEARING PRESSURES. SEE SHEET ST101 FOR COMPLETE STRUCTURAL NOTES. SEE SHEET ST100 FOR FOOTING SCHEDULE. SEE SHEET 5T400 E 5T401 FOR FOOTING DETAILS. ALL POURED CONCRETE FOOTINGS TO BE 3000 P51 CONCRETE. TYPICAL EXTERIOR F1205T WALL FOOTINGS TO BE 2'-0' WIDE x I'-3' DEEP W/ (2) - #6 CONTINUOUS BARS. TYPICAL TOP OF FOOTING ELEVATION - 96-0'. SEE DETAIL I/5T400. TYPICAL INTERIOR BLOCK WALL FOOTINGS TO BE 2'-0' WIDE x I' -O' DEEP W/ (2) - #5 CONTINUOUS BARS. TYPICAL TOP OF FOOTING ELEVATION - 99'-4'. TYPICAL 2x INTERIOR BEARING WALLS E SHEAR WALLS TO HAVE THICKENED 5LAB5 1'-0' WIDE x I'-0' DEEP W/ (2) - #5 CONTINUOUS BARS. TOP OF SLAB / FOOTING ELEVATION - 100'-0'. SEE DETAIL 2/5T400. SEE DETAIL 10/5T400 FOR TYPICAL THICKENED SLAB @ WOOD STUD BEARING WALL BESIDE BLOCK WALL. FOUNDATION NOTES: a� V T O N L U 0 U oz Architecture TYPICAL EXTERIOR FROST WALLS TO BE 8' WIDE CONCRETE BLOCK. SEE DETAIL I E 3/6T400. 1414 UNDERWOOD AVE. PROVIDE INTERIOR BLOCK WALLS A5 SHOWN ON PLANS, SEE DETAILS ON SHEET 5T400 FOR WALL REINFORCING. W A U W A T O S A , WI 53213 DOWEL ALL VERTICAL BARS INTO FOOTINGS WITH SAME SIZE STANDARD HOOK. 4 1 4. 4 3 1. 3 13 1 T E L ALL CONCRETE BLOCK TO HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2150 P51. 414.431.0531 F A X NOTE: FOUNDATION DIMENSIONS ARE NOMINAL. VERIFY MA50NRY RA. 51ZE5 W/ PRODUCT MANUFACTURER F WWW . A G A R C H . C O M SHOP DRAWINGS. A T c h i t e c t u T e INTERIOR SLAB ON GRADE NOTES: E n g i n e e r i n g P l a n n i n g TYPICAL 4' THICK, 3000 P51 CONCRETE SLAB ON GRADE W/ bxb - W I.4xW 1.4 W.W.F. OR SYNTHETIC FIBERS ON 10 MIL VAPOR BARRIER ON 6' MIN. COMPACTED GRANULAR DRAINAGE FILL. A COMBINATION OF CONSTRUCTION E CONTROL. JOINTS EACH WAY SHALL CREATE FLOOR PANELS OF 225 50. FT. MAX. PROVIDE 15MATION JOINTS BETWEEN SLAB F STEEL COLUMNS. TYPICAL TOP OF SLAB ELEVATION - 100'-0'. REVISIONS TYPICAL STRUCTURAL STOOPS Cad ALL PUBLIC ENTRIES: VamMMAWWOR INDICATES 3q HAXIMUM TOTAL DEPTH) 4000 P51 CONC12ETE ENTRY SLAB W/ 6g mom kwA SEEN 'AN SYNTHETIC FIBERS. PROVIDE W/ bxb - W2.IxW2.I W.W.F. 7 DOWN F012M TOP OF SLAB, PITCH SLAB AWAY F120M BUILDING. OWNER, TING THIS DRAWING, nS DEEIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, RIC. AND SMALL 1 NOT RE COPIED w ANY FORM OR MANNER WTIHOUT WRITTEN AUTHORIZATION OF TTS DESIGNER/CREATOR B DRAWN 67 JC D F M.A.B. C H DATE G - 01 AUG 2011 E PROJECT _ 071101 SHEET NO. SS220 & FOUNDATION PLAN