Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
161
STUD SCHEDULE (SPRUCE PINE FIR NO. 2) SA SB SC SD SE SF SG LEVEL3 1 - 2 x 4 @ 16" O.C. 1 - 2 x 4 @ 16" O.C. 1-2x4@16"O.C. 1-2x4@16"O.C. 1-2x4@16"O.C. 1 - 2 x 6 @ 16" O.C. 1 - 2 x 6 @ 16" O.C. LEVEL2 1 - 2 x 4 @ 16" O.C. 1 - 2 x 4 @ 16" O.C. 1-2x4@16"O.C. 1-2x4@12"O.C. 2 - 2 x 4 @ 16" O.C. 1 - 2 x 6 @ 16" O.C. 1 - 2 x 6 @ 16" O.C. LEVEL 1 1 -2x4@ 16" O.C. 1 1 -2x4@ 12" O.C. 1 2-2x4@ 16"O.C. 1 2-2x4@ 12"O.C. 1 3-2x4@ 12" O.C. 1 -2x6@ 16" O.C. 1 -2x6@ 12" O.C. 11 KEY MAP STUD LAYOUT NOTES: 1. STUDS MAY BE SOLID SAWN OR STRUCTURAL FINGER JOINTED (END -JOINTED) LUMBER OF THE SAME SPECIES AND GRADE OF LUMBER AS SPECIFIED ON THESE PLANS. 2. STUD SPACING MAY BE ADJUSTED AS SHOWN IN TYPICAL PLUMBING CHASE FRAMING DETAIL ON TYPICAL FRAMING DETAILS. 3. S_1 ENOTES STUD CALLOUT & LEVEL. (SEE STUD SCHEDULE) 4. REFER TO FRAMING PLANS FOR ADDITIONAL POSTS AND STUD PACKS NOT SHOWN HERE. 5. ALL SHEAR WALLS SHALL HAVE STUDS @ 16" O.C. (MAX.) SEE BRACING PLANS FOR LOCATION. 6. SEE S9.OX THRU S9.OX FOR ADDITIONAL FRAMING MEMBERS REQUIRED AT SHEARWALLS AND HOLDOWNS. 7. ALL VOLUME AREAS SHALL BE BALLOON FRAMED TO CEILING OR FRAMING ABOVE. WALL FRAMING SHALL NOT BE BROKEN AT INTERMEDIATE POINTS WITHOUT LATERAL SUPPORT. 8. STAIRWELL FRAMING: UP TO 14'-6" PROVIDE 2-2X4 @ 12" O.C. U.N.O. 9. RE: ARCH. PLANS FOR ALL NON -LOAD BEARING INTERIOR PARTITIONS. Project INDICATES EXTENT OF STUD CALLOUT. BARRINGTON at CARMEL CARMEN, INDIANA CONSULTING ENGINEERS STRUCTURAL CONSULTANTS ASSOCIATES, INC. 12511 Emily Court Sugar Land, Texas 77478 713.779.7252 800.422.7252 FAX: 713.779.1173 email: sca@scahouston.com www.scaengineers.com Louisville, Kentucky 502.426.6789 Orlando, Florida 407.893.6200 Copyright © SCA Consulting Engineers This document is copyrighted and is an instrument of service for the specific project for which it was prepared. Reuse, copying or modification of this document whether in hard copy or electronic format other than for the specific purpose intended, without written permission from SCA Consulting Engineers is a violation of federal copyright law. The ideas, concepts, inventions or methods described herein are Patent Pending and are the sole property of SCA Consulting Engineers. ISSUE DATES Design Development 06-06-11 Bid Issue xxxxx Permit Issue 08-01-11 Construction Issue xxxxx Revisions STUD LAYOUT PLAN LEVEL 1 WING F, G & H SCALE: 3/32" = T-0" Drawn LHB Project 211071 Check Sheet Date S3.13