Loading...
HomeMy WebLinkAbout32I C C 0 ............. ...:...,....:. .:::::::: , �...... DRIVE-THRU ;I CHECK-IN' 1 /2" VERTICAL AIR STUB WITH SHUT-OFF ABOVE . HB .azz .., \:.:.. IN ---------------- LOBBY. ------------ _---- ...... Q PARTS STORAGE ..;\ V •• LAV � MEN 1-1/4" CW WOMEN 1" cw 1" cw WCH CC] WCH MS EXIT PA8SAGEWAY ------------ m 20 GALLON ELECTRIC WATER HEATER ABOVE ' WITH P&T VALVE - (MOUNT ON BRACKET ABOVE MOP SINK) tz ------------ TENANT SPACE "B" i 4 i . . . . . . . . . . . . . . . I 2 5 I TENANT SPACE "E" PLUMBING DOMESTIC WATER PLAN SCALE: 1 /8" = 1 ' '0- 3 REMOVE ALL DOMESTIC WATER PIPING DOWNSTREAM OF THIS POINT - SEE ARCHITECTURAL DEMOLITION PLAN DOMESTIC WATER TURN ELL UP AT EXISTING INCOMING SERVICE TO VERTICAL, REDUCE PIPING TO 2", INSTALL BACKFLOW PREVENTOR, RE -INSTALL EXISTING WATER METER, AND INSTALL NEW BYPASS VALVE AS REQUIRED BY LOCAL JURISDICTION ENERGY CODE COMPLIANCE - PLUMBING 1. PLUMBING CONTRACTOR SHALL COMPLY WITH THE INDIANA ENERGY CODE IN EFFECT AT TIME OF STATE RELEASE AND BUILDING PERMIT. 2. NOTE ALL HOT WATER PIPING IS INDICATED TO BE INSULATED AND THIS EXCEEDS THE ENERGY CODE REQUIREMENTS. 3. ALL LAVATORY AND WAITING SINK FAUCETS SHALL BE LOW -FLOW, LESS THAN 2 GPM, WATER CLOSETS TO BE LOW -FLOW, LESS THAN 1.6 GPF. T&W Corporation 3841 W. Moms St. Indianapolis, Indiana 46241 z Q C __J L. n W -o ai -f—f C a ry W �UE� Q i C ch L CU C.) C) 0 o U _0 ca V e- 10 W L— F- zi O O atS `= ._ � CoN UE -r— o O ULV ^ I/ V C CL 'd - D d' r P202 Project No. 10004