HomeMy WebLinkAbout115ME
CO
3" INCOMING
WATER SUPPL
OFFSET COLD WATER
SUPPLY TO AVOID STRUCTURAL
STEEL BEAM
7-
1" HOT WATER
SUPPLY TO FIXTURES
DIET
UNI
MOUNT WATER HE!
ON HEAVY GAUGE
SHELF.
TATIC MIXING
, 2)
THERMOMETER (TYPICAL)
3/4° TEMP/PRESSURE
RELIEF VALVE
TERMINATE TEMP/PRESS
RELIEF PIPE OVER MOP
SERVICE BASIN
DRAIN VALVE
WATER HEATER PIPING
DETAIL A
NO SCALE
CAST IRON CLEANOUT WITH COVER
SEWER MATERIAL AND SIZE AS REQUIRED
24" X 24" X 8" THICK
FINISHED GRADE OR PAVING CONCRETE PAD
EXTENSION -SAME SIZE AS SEWER
UP TO 4" DIAMETER
SEWER MATERIAL --
SIZE AS REQUIRED
LONG SWEEP ELBOW OR COMBINATION
'Y' BEND (USE REDUCING TYPE WHERE REQUIRED)
EXTERIOR CLEANOUT
DETAIL B
NO SCALE
COOLING COIL
CONNECT TO CONDENSATE
DRAIN PAN. REFER TO
HVAC DRAWING FOR EXACT
LOCATION
CLEANOUTS
STATIC SEAL
WATER SEAL
SEE FLOOR PLAN
FOR CONTINUATION
OF PIPING.
NOTE:
VERIFY ACTUAL STATIC PRESSURE
WITH THE BALANCING CONTRACTOR
AT THE DRAIN CONNECTION.
DIMENSION SHALL MATCH STATIC
PRESSURE + 1n.
FAN COIL UNIT CONDENSATE
DRAIN PIPING
DETAIL C
NO SCALE
SLUSH CONCRETE
REINFORCEMENT
PP=2)
DUPLEX BACKFLOW PREVENTER AND METER ASSEMBLY
DETAIL E
NO SCALE
cV
N
FINISHED FLOOR
BLOW THRU AIR
HANDLER UNIT
�- 1 1/4" 'P' -TRAP
CONNECT CONDENSATE
DRAIN TO DRAIN PAN
CONDENSATE DRAIN PIPING
DETAIL D
NO SCALE
3" SUCTION AND
DISCHARGE
(SEE NOTE 2)
Pin
NOTES:
1. SYSTEM IS SUPPLIED WITH DOUBLE ENDED HEADERS FOR FLOW IN EITHER DIRECTION.
2. SYSTEM IS SUPPLIED WITH RUBBER IN SHEAR VIBRATION MOUNTS AND SINGLE SPHERE FLEXIBLE CONNECTORS,
DOMESTIC WATER BOOSTER PUMP ASSEMBLY
DETAIL F
NO SCALE
PLUMBING EQUIPMENT SCHEDULE
VFD
MAKE do MODEL NUMBER
(OR APPROVED EQUAL)
DESCRIPTION
CAPACITY
1� �u
Pin
NOTES:
1. SYSTEM IS SUPPLIED WITH DOUBLE ENDED HEADERS FOR FLOW IN EITHER DIRECTION.
2. SYSTEM IS SUPPLIED WITH RUBBER IN SHEAR VIBRATION MOUNTS AND SINGLE SPHERE FLEXIBLE CONNECTORS,
DOMESTIC WATER BOOSTER PUMP ASSEMBLY
DETAIL F
NO SCALE
PLUMBING EQUIPMENT SCHEDULE
MAKE do MODEL NUMBER
(OR APPROVED EQUAL)
DESCRIPTION
CAPACITY
ELECTRICAL
CHARACTERISTICS
NOTES
ITEM
LOCHINVAR
ELECTRIC WATER HEATER
19 GAL.
120V, 150OW
NOTE 1
WATER HEATER
(WH -1)
JRCO20Z
LOCHINVAR
ELECTRIC WATER HEATER
19 GAL.
120V, 1500W
NOTE 1
WATER HEATER
(WH -2)
JRCO20Z
LAWLER
61-25
THERMOSTATIC MIXING VALVE
6 GPM ® 5 PSI
PRESSURE DROP
-
-
-
-
TERMOSTATIC MIXING
VALVE (TMV-1)
LAWLER
61-25
THERMOSTATIC MIXING VALVE
6 GPM ® 5 PSI
PRESSURE DROP
-
-
_
TERMOSTATIC MIXING
VALVE (TMV-2)
REDUCE PRESSURE ZONE_
BACKFLOW PREVENTER
91 GAL, 6 PSI PRESSURE DROP
PROVIDE AIR GAP FITTING AS REQ'D
AND TERMINATE OVER FLOOR DRAIN
BACKFLOW PREVENTER
(BFP-1)
WATTS
SERIES 994 -3" -NRS
WATTS
SERIES 994 -3" -NRS
REDUCE PRESSURE ZONE
BACKFLOW PREVENTER
91 GAL, 6 PSI PRESSURE DROP
_
PROVIDE AIR GAP FITTING AS
DRAIN
AND TERMINATE OVER FLOOR DRAIN
BACKFLOW PREVENTER
(BEP -2)
DOMESTIC WATER VC SYSTEMS EACH PUMP: 91 GPM TO BOOST EACH PUMP: -
BOOSTER PUMP VC613-SS DUPLEX BOOSTER PUMP SYSTEM PRESSURE FROM 40 PSI TO 60 PSI 3 HP, 480V, 3 PH -
(DWBP-1)
NOTES:
1. PROVIDE WALL MOUNTED EQUIPMENT PLATFORM LIKE HOLDRITE MODEL 040-SWHP-W; 14 GAUGE GALVANIZED STEEL DRAIN PAN, CORNER BRACKETS ZINC PLATED, LOW CARBON
STEEL THREADED HANG RODS; DRAIN PAN DRAIN BODY ASSEMBLY. ROUTE DRAIN PAN DISCHARGE TO MOP BASIN AND TERMINATE WITH AIR GAP.
NOTE:
1. ALL FLOOR/TRENCH DRAINS 4" AND -LESS REQUIRE PRO -SET TRAP GUARD INSERT.
NOTES:
1. MOUNT LAVATORY UNDER COUNTERTOP.
2. MOUNT FAUCET 42" ABOVE FINISHED FLOOR.
CARMEL CITY CENTER
COMMUNITY DEVELOPMENT
CORPORATION
30 West Main Street, Suite 220
Carmel, Indiana 46032
317.571-2787
Architect:
" n =1
PEDCOR DESIGN GROUP
Architecture / Project Management:
355 City Center Drive
Carmel, Indiana 46032
317.705.7979 (phone)
317.705.7980 (fax)
CIRCLE DESIGN GROUP, INC.
5510 & E0 SUM. SUIE F . KWA%.A N 1622/. (An IM -M
1 ATW, %U MTDk M CMD"r FLMM FW PROTECTICK
IMNVIC w0 nECOM'A DE90M 0MUMM
870242 '
CV
Project:
�
U w
Q
w w
U =
Q X
� 0co
N
M
Z V O
U c0
W Q�
W J Z
M -
C� Co a�
W V E
T. z CUi
D U
Z J
O :D
WM
� w
Q U.
LL
.P J LL -
O
COPYRIGHT & OWNERSHIP OF DOCUMENTS
THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE
PROPERTY OF THE ARCHITECT AND PEOCOR DESIGN GROUP. LLC. ALL
INFORMATIONCONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND
DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS
PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT.
INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL
INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND
UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND
PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,
THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR
PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE
DUPLIGATED. COPIED, D(HIBITED. PHOTOGRAPHED, PUBLISHED, MODIFIED
OR OTHERWISE DISTRIBUTED IN ANYWAY WITHOUT THE SPECIFIC AND
PRIOR WRITTEN CONSENT OF THE ARCHITECT. JAMES R. STUTZMAN AND
PEDCOR DESIGN GROUP, LLC. c COPYRIGHT 2006, 2007, 2008. 2009,
JAMES R. STUTZMAN, AIA, CARMEL, IN.
BID SET NO
SHELL & CORE
Print Date Sheet Issue Date
9/14/09 9/15/09
Drawn By Checked By
JDE AV
Last Revision Date:
O
O
O
O
O
O
Project Number:
Sheet Title:
SCHEDULES AND
DETAILS -
PLUMBING
Sheet Number:
P501