Loading...
HomeMy WebLinkAbout13E.5 F.1 F.4 F.8 G.4 G.8 H.1 H.7 J.1 J.8 K.1 L.8 N.1 N.6 P.1 P.6 Q.5 Q.8 GENERAL NOTES € A. +0'-0" = 833.50' 1 B. THESE GENERAL NOTES APPLY TO ALL SHEETS. A201 I I I ( I C. DIMENSIONS ARE TO FACE CONCRETE WALLS, i I 1 13 1 3 4 I 1 3 1 I 3 I 1 3 I 1 MASONARY WALLS, FACE OF METAL STUDS, OR COLUMN A301 A310 I A301 A302 A302 A30� I A303 A303 I A304 A304 ( A305 I A305 I A306 CENTERLINE UNLESS NOTED OTHERWISE. ---- -�--- _�_ 216'-3 7/8" D. BUILDING IS FULLY EQUIPPED WITH AN AUTOMATIC 18' 10" 9'-1 3/4" 36- 1/4" 1 5'-4 1/8" 57'- "65i 6 8'- " SPRINKLER SYSTEM. 6 101/ '-3" 1 ` I I A13 +-----------------"I"--------- E. ALL WORK SHOWN IN THESE DRAWINGS AND IN THE -- -- —r-- --moi-� �--- -�-------------I----------r SPECIFICATIONS SHALL BE BASE BID UNLESS NOTED TO oBE BYALTERNATE BID. 11 • O 11 sa — — — — 6q*–P F. REFER TO SHEETAG001 FOR WALL TYPES. PORCH Q ��� 1 �G. REFER TO SHEET A601 FOR DOOR TYPES. 6 ..L � , 301 ---- p A20 -----------------I— --------- --------——— — — — — — I— — — — — — — — Dr I H. REFER TO SHEETA-602, 603 FOR WINDOW TYPES.o f 6q --�ORCH - Lay1 s GRILL BE I I I V-7 5/8" 4 3/8" 4 3/8" 9'-7 5/8" I RM 316 - - - ( I J. PAINTALL HOLLOW METAL DOORS AND FRAMES, M EXPOSED STEEL, LINTELS, HANDRAILS, GUARDRAILS, 308 sA m I LADDERS BEAMS, ETC. IN ALL FINISHED AREAS. PARCEL I 'i �, `° I Q I I I m I U I � I I 00 ► OD , I Q �� �� 6 3 I I $ STAIR 1 co � I � K. ALL HOLLOW METAL DOOR FRAMES IN MASONRY THEATRE,I �� a _ - _ - - - i i I I ELEV. 3 I `n CID ® WALLS SHALL BE GROUTED FULL. 3 ` 3 -4 ' 6,. 4'-8" I 3, a s 18'-1 1/2" I Z-71/2", s IL. CAULK INTERIOR AND EXTERIOR PERIMETERS OF ALL A405 I I I 1 I I I I HOLLOW METAL AND ALUMINUM DOORAND WINDOW A401 3A I - —4- 3 FRAMES. A304 3'-8" 11" I 11 3.-8,. 4 M. VERIFY UNDERCUT REQUIREMENTS OF DOORS WHERE CARPET OR OTHER FLOORING IS TO BE INSTALLED. —. — — —. —. — — — 3A _ __ — — —. —. —, — —. — — — —. - — 3A — — — — — —. — — — — — — — — — — — — — — — — — — O I — — — — — — — — —! — — —. —. —. I — 3. —. —. I — I— —. — L. LEASABLE I I m I I N. MAXIMUM SPACING BETWEEN GYP. BD. CONTROL JOINTS SPACE I - LEASABLE 'v I 3 - I N I (C.J.) SHALL BE 30'-0". THE MAXIMUM DISTANCE FROM A 310 W SPACE A201 CORNER TO A JOINT SHALL BE 24'-0". A202 I `� I `° I 313 o I 315 I `° I I = PROVIDE CONTROL JOINTS BETWEEN ALL INTERIOR LOAD M - . - . - - - . - . - - I °0_ - - - BEARING WALLS AND NON -LOAD BEARING WALLS; ATALL — — — — — — — — Z N 16.5 ABRUPT CHANGES IN WALL HEIGHT; AT ALL CHANGES OF � \ OF ROOM � _ ---- 9'-61 5'-1 1/2" 21'-8 1/ 9'-6 5 8" I 16'-7 1y4" 10 3/8" I I -'- °° I I I n WALL THICKNESS; AT PILASTERS AND COLUMNS. VERIFY --- 6.. '�--------�` 03/8 �— _ ;� 312 - ® o FINAL JOINT LOCATIONS WITH AIE BEFORE 2 I— 1 311 I I I I ( I I I in CONSTRUCTION. A310 - - ---------------- — ---------1 - f--- ---- --- --- - I * Q_ ELEC. ROO I I I 0. MAXIMUM SPACING BETWEEN GYPSUM DRYWALL JOINTS m (70 "' I J I 3 3„ I L I I I 6 (C.J.) SHALL BE 30 UNLESS NOTED OTHERWISE. VERIFY —U — s — . — 3A D — . — . 3A ALL LOCATIONS WITH ARCHITECT BEFORE — — — — — — — — — — — — �- — — — — — — — — — — — — — — — — —. I — — — — — —.— — CLOSmm CONSTRUCTION. / R 5 M 3 STAIR 2 302 I I I I I A MINIMUM CLEAR AREA OF 18 IS REQUIRED TO THE SIDE 8e2 , 304 _ EN'S R o I ELEV. 1 ELEV. 2 3A I 1'-4 3/8" 2'-3" P. '� �" i � �� 3 I OF EACH DOOR STRIKE JAMB ON THE PULL SIDE FOR 304 i c I I DOORS ON AN ACCESSIBLE ROUTE. sc 3B I Ms Ma 6C M I I I Q. ALL ROOF SLOPES ARE 1/4" PER FOOT UNLESS NOTED OTHERWISE. 3A I COI 6° 4'-a" I I 5 I s m mpg I R. ALL METAL FRAMED WALLS SHALL EXTEND TO ROOF DECK I I I -fg3Bisc I CORR. I . I ELEV. LOBBY I I A113 I �I I co _ ABOVE AND BE PROVIDED WITH FIRE STOP SEALANT 306 I I 307 I I I I I I I PORCH u') UNLESS NOTED OTHERWISE. -- RM 317 WOMEN'S RR ( I I I / — 1317AO I °' - ^� 15.2 S. ALL DOOR FRAMES WILL BE LOCATED 4" FROM CLOSEST RUMS UI I w — — — — ' A 3 —I L_ - - - - - - - - - - - - - - -- -- - - -- - —--- yy - — — — — — —All- - - - - ADJACENT WALL. U.N.O. -- — — — — -- — — — — — — -- -- —1 — . — — _——�— I 6A o — —. —. — —. —. —. — — —. — —. —. T — — — — —. _ _ �- 15 T DO NOT SCALE DRAWINGS, CONTACT ARCHITECT IF A401 ��- - - ��00 co ©i i I l I L o SPECIFIC DIMENSION IS NEEDED 8 "'7(A4502—> A403 34A202 A404 2 3 1 A113 4 3 1 A307 A307 A307 A306 A306A306 SIM.OPP HAND PARCEL °fj J —C-3 GARAGE, N.I.C. THIRD FLOOR 3 a £. PEDCOR DESIGN GROUP 00033126 STATE OF ,' ll!►liittiitlt111\\ rrrirl North Parcel 7-C Keyplan P C> CV � U w I� Jw W = � NU 1..` x Q p m N �► Z 0 W � � w � •, MJ W Z 0 W V � E Z � ~ 0 U Z J o Z) w In (D w QU J LL J LL O .... ...... .......................... ........................... ................... F (if � a, a I I ....................................................................................................................... F1 BID SET NO SHELL & CORE _�...WW ...._ ...._.W _........._....._ .......... I ............ ......... 9/16/09 9/15/09 _.. B; EJ D LGA Lest Revlsbn Date THIRD FLOOR PLAN A103