HomeMy WebLinkAbout71WALL WIND LOAD DIAGRAM E.5 Q.8 52.8FT T F I 3 I 2 1 3 1- - - - - - - - - - - - - 26.4 FTr ,26 .4 FT 2a 2 1 12 a I a I L -T -----------r 2a 3 1 2 1 3 IF - 04 CC! LO 15 2a WALL WIND LOAD DIAGRAM 2a C&C WALL ZONE PRESSURES (psf) Bar Size POSITIVE INTERNAL PRESSURE NEGATIVE INTERNAL PRESSURE Location +4,+5 -4 -5 +4,+5 -4 -5 CFS Stud 8.4 -14.8 -23.2 13.9 -9.3 -17.7 Unit Pressure 11.1 -16.6 -30.5 16.6 -11.1 -25.0 C&C GROSS ROOF ZONE PRESSURES (psf) Bar Size POSITIVE INTERNAL PRESSURE NEGATIVE INTERNAL PRESSURE Location -1 -2 -3 -1 -2 -3 Joist -19.9 -32.0 -44.0 -14.3 -26.4 -38.5 Truss -19.9 -32.0 -44.0 -14.3 -26.4 -38.5 Deck Pressure 24.3 38.2 52.1 -18.8 32.7 46.5 DEVELOPMENT LENGTH COMPRESSION Bar Size fc (Normal Weight Concrete), psi 2500 3000 4000 #3 9" 9" 8" #4 12" 11" 10" #5 15" 14" 12" #6 18" 17" 15" #7 21" 20" 17" #8 24" 22" 19" #9 28" 25" 22" #10 31" 28" 25" #11 34" 31" 27" #14 41" 1 38" 1 33" #18 55" 1 50" 43" NOTES: 1. Clear spacing not less than 2xDb. 2. Clear cover not less than Db. 3. Db = bar diameter. DEVELOPMENT LENGTH TENSION - BOTTOM BARS Bar Size Bar Size fc (Normal Weight Concrete), psi 2500 3000 4000 #3 18" 17" 15" #4 24" 22" 19" #5 30" 28" 24" #6 36" 33" 29" #7 53" 48" 42" #8 60" 55" 48" #9 68" 62" 54" #10 77" 70" 61" #11 85" 78" 67" #14 102" 83" 81" #18 136" 124" 108" NOTES: 1. Clear spacing not less than 2xDb. 2. Clear cover not less than Db. 3. Db = bar diameter. NOTES: 1. Min 12" of fresh conrete below bar. 2. Clear spacing not less than 2xDb. 3. Clear cover not less than Db. 4. Db = bar diameter. DEVELOPMENT LENGTH TENSION - TOP BARS Bar Size Bar Size fc (Normal Weight Concrete), psi 2500 3000 4000 #3 24" 22" 19" #4 32" 29" 25" #5 39" 36" 31" #6 47" 43" 37" #7 69" 63" 54" #8 78" 72" 62" #9 88" 81" 70" #10 100" 911, 79" #11 110" 101" 87" #14 133" 121" 105" #18 177" 161" 140" NOTES: 1. Min 12" of fresh conrete below bar. 2. Clear spacing not less than 2xDb. 3. Clear cover not less than Db. 4. Db = bar diameter. NOTES: 1. Clear spacing not less than 2xDb. 2. Clear cover not less than Db. 3. Db = bar diameter. 4. Mechanical couplers may be substituted for #6 bars and larger. TENSION LAP SPLICES BOTTOM BARS Bar Size Bar Size fc (Normal Weight Concrete), psi 2500 3000 4000 #3 24" 23" 20" #4 32" 29" 25" #5 39" 37" 32" #6 47" 43" 38" #7 69" 63" 55" #8 78" 72" 63" #9 89" 81" 71" #10 101" 91" 80" #11 1111, 102" 88" #14 133" 1 121' 1 106" #18 1 177" 1 162" 1 141" NOTES: 1. Clear spacing not less than 2xDb. 2. Clear cover not less than Db. 3. Db = bar diameter. 4. Mechanical couplers may be substituted for #6 bars and larger. NOTES: 1. Min 12" of fresh conrete below bar. 2. Clear spacing not less than 2xDb. 3. Clear cover not less than Db. 4. Db = bar diameter. 5. Mechanical couplers may be substituted for #6 bars and larger. COMPRESSION LAP SPLICES TENSION LAP SPLICES TOP BARS Bar Size Bar Size fc (Normal Weight Concrete), psi 2500 3000 4000 #3 32" 29" 25" #4 42" 38" 33" #5 51" 47" 41" #6 62" 56" 49" #7 90" 82" 71" #8 102" 94" 81" #9 115" 106" 91" #10 130" 119" 103" #11 143" 132" 114" #14 173" 158" 137" #18 231" 210" 182" NOTES: 1. Min 12" of fresh conrete below bar. 2. Clear spacing not less than 2xDb. 3. Clear cover not less than Db. 4. Db = bar diameter. 5. Mechanical couplers may be substituted for #6 bars and larger. COMPRESSION LAP SPLICES MIN COL WIDTH Bar Size fc (Normal Weight Concrete), psi 2500 3000 4000 #3 12" 12" 12" #4 15" 15" 15" #5 19" 19" 19" #6 23" 23" 23" #7 27" 27" 27" #8 30" 30" 30" #9 34" 34" 34" #10 39" 39" 39" #11 43" 43" 43" #14 51" 51" 51" #18 68" 1 68" 68" NOTES: 1. Mechanical couplers may be substituted for #6 bars and larger. ANGLE UNSTIFFENED JOIST SEAT ANGLE BEARING CAPACITY MIN COL WIDTH 6" 8" 8" 9" 10" 12" 12" SEAT ANGLE LENGTH 4" 5" 6" 7" 8" 9" 10" SEAT ANGLE ASD CAPACITY L5x31120/8 (LLV) 1.9k 2.4k 2.9k 3.4k 3.9k 4.4k 4.9k L5x31/2x1/2 (LLV) 4.1k 5.1k 6.2k 7.2k 8.2k 9.3k 10.3k STIFFENED JOIST SEAT ANGLE BEARING CAPACITY MIN COL WIDTH 6" 8" 8" 9" 10" 12" 12" SEAT ANGLE LENGTH 4" 5" 6" 7" 8" 9" 10" SEAT ANGLE ASD CAPACITY L6x4xl/2 (LLV) 26.Ok 26.Ok 26.Ok 26.Ok 26.Ok 26.Ok 26.Ok L6x4x1/2 (LLV) 44.2k 44.2k 44.2k 44.2k 44.2k 44.2k 44.2k ELEVATION @ TYP UNSTIFFENED SEAT COLUMN W OR HSS COL ANGLE 5/16/ 3/8" STIFFENER 3/4" RET @ PLATE TOP I I I 5/16 V ELEVATION @ TYP STIFFENED SEAT JOIST GIRDER BRIG CAPACITY SCALE: 3/4" = V-0" CFS HEADER SCHEDULE (INTERIOR NON -LOAD BEARING WALLS) OPENING HEADER JAMB 0' 0" TO 8'-0" (2) 600S162-33+ MIN (2) 362S162-33 (16'-0" MAX HGT) 6'-1" TO 8'-0" (2) STUD DEPTH T150-33 MIN (2) 60OS162-33 (20'-0" MAX HGT) 8'-1" TO 10'-0" (2) 800S162-33+ MIN (2) 362S162-33 (14'-0" MAX HGT) 11" 10" (2) STUD DEPTH S162-33 MIN (2) 60OS162-33 (20'-0" MAX HGT) 10' 1" T012' 0" (2)1000S162-54+ MIN (2) 3625162-33 (14'-0" MAX HGT) 8" (2) STUD DEPTH S162-54 MIN (2) 80OS162-33 (20'-0" MAX HGT) 12' 1" T016' 0" (2)12005162-54+ MIN (2) 60OS162-33 (14'-0" MAX HGT) 3" (2) STUD DEPTH S162-33 MIN (2) 800S162-54 (20'-0" MAX HGT) CFS HEADER SCHEDULE (EXTERIOR NON -LOAD BEARING WALLS) OPENING HEADER JAMB (6) 0'4" TO 6'-0" (2) 600S162-54+ (2) STUD DEPTH T150-54 MIN (2) 60OS162-54 6'-1" TO 8'-0" (2) 80OS162-54+ (2) STUD DEPTH S150-54 MIN (2) 60OS162-68 8'-1" TO 12'-0" (2)1200S162-68+ (2) STUD DEPTH S150-68 MIN (2) 6005250-68 CFS HEADER SCHEDULE NOTES: 1. WEB STIFFENERS REQUIRED AT EACH END OF HEADERS AND SILL. 2. HEADERS ARE BOXED SECTIONS, SEE DETAILS. 3. JAMBS ARE BACK TO BACK SECTIONS, SEE DETAILS. 4. PROVIDE SAME FRAMING FOR OPENING SILL AS SHOWN FOR HEADER. 5. SCHEDULE APPLIES TO 16' 0" MAXIMUM STUD UNBRACED LENGTH (WALL HEIGHT). 6. MINIMUM JAMB DEPTH SHOWN, ACTUAL JAMB DEPTH TO MATCH STUD DEPTH IF LARGER. PIER SCHEDULE Mark DEVELOPMENT LENGTH HOOKS Ties Bar Size fc (Normal Weight Concrete), psi 2500 3000 4000 Hook Length 90 degree 180 degree #3 9" 9" 6" 6" 3" #4 12" 11" 10" 6" 3" #5 15" 14" 12" 8" 3" #6 18" 17" 15" 9" 3" #7 21" 20" 17" 11" 4" #8 24" 22" 19" 12" 4" #9 28" 25" 22" 14" 5" #10 31" 28" 25" 16" 6" #11 34" 31" 27" 17" 1 6" #14 41" 38" 33" 21" 1 7" #18 55" 50" 43" 28" 1 9" PIER SCHEDULE Mark Pier Size Pier Vert Reinforcing Ties Remarks Width Length Quantity Size P1 2' - 8" 2' - 8" 12 #9 #3 Ties @ 3" T&B, BAL @ 12" P2 5'- 4" 3' - 9" 12 #9 #3 Reinf Per P1 P3 4' - 7" 3'- 9" 12 #9 1 #3 IlReinf Per P1 Pier Schedule Notes: 1. Provide 1 1/2" concrete cover over ties. 2. See typical pier elevation for tie and vertical bar placement. 3. Provide CRSI Typ Bar Bend No T5 ties for all vertical face bars, if there are more than for vertical bars in pier. CONCRETE WALL SCHEDULE Mark Width Horiz Reinforcing Vert Reinforcing Dowel Reinforcing Reinf Location Size Spa. Size Spa. Size Spa. CW8 8" #5 1' - 0" #5 1' - 0" #5 1' - 0" Center CW24 2' - 0" #5 1' - 0" #5 1' - 0" #5 1' - 0" 1 Ea Face Concrete Wall Schedule Notes: 1. Provide 11/2" concrete cover, typical uno. 2. Provide wheel spacers or CRSI Typ Bar Bend T% at 36" each way to assure adequate concrete cover. 3. See sections and details for all bars not included in schedule. MAT FOUNDATION SCHEDULE Mark Thickness Top Reinforcing (Ea Way) Bott Reinforcing (Ea Way) Comments Size Spa Size Spa MAT 1 2' - 0" #5 11-01, #6 1' - 0" Hook each end. AP1 Piles as shown MAT 1 2' - 0" #5 l'- 0" #6 V_011 Hook each end. AP1 Piles as shown Mat Foundation Schedule Notes: 1. AP1 indicates 18" dia auger cast pile. MASONRY WALL SCHEDULE Mark Type Horiz Wall Reinf Vertical Wall Reinforcing Location Size Spa. MW6 6" CMU See Note 3 #5 4' - 0" Center MW8 8" CMU See Note 3 #5 4' - 0" Center Masonry Wall Schedule Notes: 1. Provide 2" concrete cover from outside face for bars in each face. 2. Grout all cores with rebar solid, unless solid grouted wall is shown. 3. Provide ladder type horizontal reinforcement at 16" oc. Side and cross rods shall be #9 wire, galvanized, see specifications. Cut joint reinforcement as control joints. GRADE BEAM SCHEDULE Mark Type Top Reinforcing Bottom Reinforcing Size Base Plate Size Thickness Width Stirrup Size Stirrup Spa Comments Long Size Long Size Trans Size GB1 30" x 32" 2 #9 2 #9 4 3/4" #4 l'- 2" 3/4" GB2 30" x 32" GB2 4 #9 4 #9 3/4" 1' - 0" #4 l'- 2" 3/4" GB3 36" x 32" 5 #9 5 #9 3/4" F1554 #4 l' - 2" ALIGN REINF w/ ADJACENT BRADE BEAMS Grade Beam Schedule Notes: 1. P18 indicates 18" dia auger cast pile. 2. See frame schedule for special loading. 3. Intermediate piles are embedded 4" into grade beam. J T/GB (SEE PLAN) U 8 CAD LU GB SUPPORTED ON PILES Column Schedule Notes: 1. See typical details for column base construction. BLOCK LINTEL SCHEDULE FOR ALL LINTELS NOT INDICATED ON PLANS COLUMN SCHEDULE Concrete Lintel Up to 6-8" Size Base Plate Size Thickness Width Length Quantity Anchor Rods Size Material HSS2X2X3/16 W W U = HSS4x4xl/4 3/4" 10" 10" 4 3/4" A36 HSS5x5x3/8 3/4" 11" 11" 4 3/4" F1554 HSS6X0.375 3/4" 1' - 0" 11-01, 4 3/4" F1554 W10x33 1" l' - 4" 1' - 4" 4 3/4" F1554 W10x49 1 1/4" l' - 4" l' - 4" 4 1" F1554 W10x49A 2" 1' - 10" 1' - 10" 6 1 1/2" F1554 W 12X45 1 1/2" 1' - 8" 11-81, 4 1 " F1554 W 12X45A ill 2' - 0" 2' - 0" 6 1 1/2" F1554 W12X53 1 1/2" l'- 8" 1' - 8" 4 1" F1554 W 12X53A 1 3/4" 2' - 0" 2' - 0" 6 1 1/2" F1554 W 12X65 1 3/4" l'- 8" l'- 8" 4 1 " F1554 W 12X65A 1 3/4" 2' - 0" 2' - 0" 6 1 1/2" F1554 W 12X72 1 1/2" l' - 7" l'- 7" 4 3/4" F1554 W12X96 1 1/2" 1' - 8" 1' - 8" 1 4 1" F1554 W 12X96A 1 3/4" 2' - 0" 2' - 0" 1 6 1 1/2" F1554 Column Schedule Notes: 1. See typical details for column base construction. BLOCK LINTEL SCHEDULE FOR ALL LINTELS NOT INDICATED ON PLANS Opening Concrete Lintel Up to 6-8" Precast concrete (3000 psi 145 pcf). (1) #5 T&B 8"deep x 4" wide, multiples to L6 x 6 x 3/8 match wall thickness. Scored to match wall bond pattern 6'-9" to 10'-0" Concrete bond beam lintel block, filled with concrete or grout (3000 psi), w/ (2) # Q 5 T&B 8" deep x wall thickness. Block Lintel Schedule Notes: 1. Block lintels shall have 8" bearing on each end of opening. 2. Bond Beam lintels shall extend 16" into wall on each side of opening. 3. Precast lintels shall be shored in center for 3 days. BRICK LINTEL SCHEDULE FOR ALL LINTELS NOT INDICATED ON PLANS Clear Opening Steel Angle Up to T-0" L5 x 5 x 3/8 T-0" up to 10'-0" L6 x 6 x 3/8 W Brick Lintel Schedule Notes: 1. All lintels shall have 8" bearing on each end of opening. 2. All exterior lintels shall be galvanized. 3. All interior lintels shall be shop primed with two coats of epoxy paint. Owner: CARMEL CITY CENTER COMMUNITY DEVELOPMENT CORPORATION 30 West Main Street, Suite 200 Carmel, Indiana 46032 317.571.2787 Architect: PEDCOR DESIGN GROUP Architecture / Project Management 355 City Center Drive Carmelm Indiana 46032 317.705.7979 (phone) 317.705.7980 (fax) Engineer: McCON11AS STRUCTURAL ENGINEERS FORENSIC ENGINEERS NATIONAL CONSULTANTS 1717 East 116th Street, Suite 200, Carmel, Indiana 46032 317-580-0402 www mccomaseng com 317-582-0766 Fax ��0\111111111/,,� �O�NEY M,CQ���'�% - 860325 �. STATE OF �t North Parcel 7-C Keyplan N Project: 9/14/09 1 U Drawn By: Checked By: LKM,njh, KLS W � Q W W U = O N 1 Z U c� W W rl. J M . V W 6 ., WT (D E 1 `_ M C U Z =J O� co W W (D U_ LL J LL O COPYRIGHT & OWNERSHIP OF DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. AL'' INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT. JAMES R. STUTZMAN. AND PEDCOR DESIGN GROUP NO PART OF WHOLE OF THIS DESIGN, THESE DRAWINGS. OR THE RESULTING BUILDING OR BUILDINGS. OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED. COPIED, EXHIBITED, PHOTOGRAPHED. PUBLISHED. MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP. c COPYRIGHT 2009 JAMES R. STJTZMAN. AIA. INDIANAPOLIS. BID SET No.1 SHELL & CORE Print Date: Sheet Issue Date: 9/14/09 9/15/09 Drawn By: Checked By: LKM,njh, KLS JAF Last Revision Date: Project Number: Sheet Title: SCHEDULES Sheet Number: ME129020