STANDARD ELECTRICAL ABBREVIATIONS AC ALTERNATING CURRENT MCB MAIN CIRCUIT BREAKER AUX AUXILIARY CONTACTS MC MECHANICAL CONTRACTOR AFF ABOVE FINISH FLOOR MCC MOTOR CONTROL CENTER AFG ABOVE FINISH GRADE MFR MANUFACTURER AHU AIR HANDLING UNIT MH MANHOLE AMP AMPERE MLO MAIN LUGS ONLY ATS AUTOMATIC TRANSFER SWITCH MMS MANUAL MOTOR STARTER BFG BELOW FINISHED GRADE MS MAGNETIC STARTER C CONDUIT MTS MANUAL TRANSFER SWITCH CCT CONTROL CIRCUIT TRANSFORMER NF NON-FUSED CCTV CLOSED CIRCUIT TELEVISION NL NIGHT LIGHT CB CIRCUIT BREAKER NTS NOT TO SCALE CMS COMBINATION MAGNETIC STARTER N/L UNSWITCHED NIGHT LIGHT CONT CONTACTOR OL OVERLOADS CP CONTROL PACKAGE OP OVERCURRENT PROTECTION CU CONDENSING UNIT PB PUSHBUTTON CUH CABINET UNIT HEATER PE PNEUMATIC -ELECTRIC SWITCH DC DIRECT CURRENT PL PILOT LIGHT DISC DISCONNECT SWITCH PUH PROPELLER UNIT HEATER EC ELECTRICAL CONTRACTOR PVC POLYVINYLCHLORIDE CONDUIT EF EXHAUST FAN 0 PHASE EMERG EMERGENCY QUAN QUANTITY EMT ELECTRICAL METALLIC TUBING R RELOCATED EP ELECTRIC -PNEUMATIC SWITCH RA RIGID ALUMINUM CONDUIT EWC ELECTRIC WATER COOLER RECEPT. RECEPTACLE EX EXISTING TO REMAIN RF RETURN FAN EXIST. EXISTING RGS RIGID GALVANIZED STEEL CONDUIT EXR EXISTING TO BE REMOVED SF SUPPLY FAN F FUSED SN SOLID NEUTRAL FA FIRE ALARM SW SWITCH FMS FLEXIBLE METAL CONDUIT SW & F SWITCH & FUSE G GROUND WIRE T THERMOSTAT GC GENERAL CONTRACTOR TC TIME CLOCK GFI GROUND FAULT INTERRUPTER TCC TEMPERATURE CONTROL CONTRACTOR HOA HAND -OFF -AUTO SELECTOR SWITCH TTB TELEPHONE TERMINAL BOARD HP HORSEPOWER TTC TELEPHONE TERMINAL CABINET Hz HERTZ TX POWER TRANSFORMER IC INTERRUPTING CURRENT V VOLT IMC INTERMEDIATE METAL CONDUIT W WIRE OR WATT INT INTERLOCK WM WIREMOLD KEC KITCHEN EQUIPMENT CONTRACTOR WP WEATHER PROTECTED KW KILOWATT W/ WITH LT DIGHT A WIRING CONNECTED (DELTA) LTS LIGHTS Y WIRING CONNECTED (WYE) MAN MASTER ANTENNA TELEVISION DISCONNECT SWITCH (NON-FUSED) ELECTRICAL SYMBOL SCHEDULE +18" AFF MOUNTING DESCRIPTION TELEPHONE WALL OUTLET ................................................. MOUNTING DESCRIPTION CEIL WALL LL• CEIL WALL F• $ e $ SINGLE RECEPTACLE Q 4 +96" AFF FLUORESCENT FIXTURE UPPERCASE LETTER IN QUOTES -TYPE LOWERCASE LETTER -SWITCH LEG FIRE ALARM COMBINATION HORN/STROBE...................... F$ FIRE ALARM REMOTE ALARM LAMP ................................. SINGLE RECEPTACLE (+44" AFF) 0 RECESSED DOWNLIGHT d# # O DUPLEX CONVENIENCE OUTLET H. I. D. FIXTURE (gCGFI DUPLEX CON. OUTLET - GFI PROTECTED Q INCANDESCENT FIXTURE -DIRECTIONAL cc DUPLEX CON. OUTLET (TOP HALF SWITCHED) ® LIGHT FIXTURE ON EMERGENCY CIRCUIT I:# RECEPTACLE (+44" AFF) ® EXIT LIGHT, LINE INDICATES FACE & • + QUADRUPLEX OUTLET ARROW INDICATES FACE WITH ARROW ®T QUADRUPLEX OUTLET (+44" AFF) SURFACE MOUNTED INCANDESCENT FIXTURE Os SAFETY TYPE CONVENIENCE OUTLET BATTERY PACK LIGHTS GgCE (�)cE DUPLEX CONVENIENCE OUTLET (EMERGENCY) OWP WEATHERPROOF CONVENIENCE OUTLET (GFI) *WP +A ERPROOF CONVENIENCE OUTLET (GFI) 208/240V OUTLET (SIZE AS NOTED) oN CONTACTOR IC 208/240V OUTLET (SIZE AS NOTED) © CAPACITOR EXPLOSION PROOF CONVENIENCE OUTLET rs AUTOMATIC TRANSFER SWITCH ® SPECIAL OUTLET (AS NOTED) OP MANUAL STARTER (P - PILOT LIGHT) �o ABOVE COUNTER VOICE/DATA OUTLET (+44") ® MAGNETIC MOTOR STARTER d VOICE/DATA OUTLET COMBINATION MAGNETIC MOTOR STARTER TELEPHONE OUTLET (VOICE ONLY) • • PUSHBUTTON STATION AS NOTED W TELEPHONE OUTLET (VOICE ONLY) +60" CIRCUIT BREAKER IN ENCLOSURE P PUBLIC TELEPHONE OUTLET (VOICE ONLY) +48" ❑P DISCONNECT SWITCH (NON-FUSED) +Q Q DATA OUTLET (DATA ONLY)FDI DISCONNECT SWITCH (FUSED) © 1© CLOCK OUTLET S SWITCH - SINGLE POLE © HS CLOCK & CLOCK OUTLET S2 SWITCH - 2 POLE QD IQD DOUBLE FACE CLOCK & CLOCK OUTLET S3 SWITCH - 3 WAY © MASTER CLOCK S4 SWITCH - 4 WAY cH cH CHIME SP SWITCH WITH PILOT LIGHT (ANY TYPE SW.) MP SOUND SYSTEM AMPLIFIER SWP SWITCH - WEATHERPROOF =R 0=0 T.V. REMOTE CONTROL SM MOMENTARY CONTACT SWITCH ='OTV faTV <TV T.V. CAMERA OUTLET Sr MECHANICAL TIMER SWITCH cnM [cAN CAMERA SK KEYED SWITCH El VOLUME CONTROL 0 DIMMER SWITCH =QP <P PROJECTOR OUTLET (SYS. INPUTS) EN BUZZER O 1-Q SPEAKER 00 BELL ® I® SPEAKER (HORN TYPE) O FO PHOTOCELL cQ T.V. ANTENNA OUTLET ® MOTOR - SINGLE PHASE =T 0=0 COMB. T.V, ANTENNA AND DUPLEX OUTLET ® MOTOR - 3 PHASE F-0 CALL-IN SWITCH CMMK3E3C1C3C= PLUGMOLD RACEWAY CIRCUIT LIFTING JACK — WM — WIREMOLD RACEWAY <IC INTERCOM STATION CONDUIT CONCEALED IN OR ABOVE CEILING QIM INTERCOM MASTER STATION —\ CONDUIT EXPOSED =4M W4 MICROPHONE OUTLET -'""'�� CONDUIT CONCEALED IN OR BELOW FLOOR =H HANDICAP DOOR PUSH PLATE HOMERUN �E EMERGENCY PANIC BUTTON �� CONDUIT TURNED UP =1 FIRE ALARM CONTROL CABINET ��� CONDUIT TURNED DOWN RA FIRE ALARM ANNUNCIATOR (REMOTE) DIRECT BURIED CABLE RAG FIRE ALARM ANNUNCIATOR (REMOTE AND GRAPHIC) -HOT -NEUTRAL -GROUND DD DIGITAL DIALER TWISTED PAIR CABLE F� FIRE ALARM PULL STATION CONDUIT STUBBED OUT & CAPPED QH I QH FIRE ALARM HEAT DETECTOR (RATE OF RISE) ^� 7 CONDUIT STUBBED OUT WITH BUSHING AN L.^ IV FIRE ALARM SMOKE DETECTOR (PHOTO -ELECTRIC) JUNCTION BOXES FIRE ALARM SMOKE DETECTOR (PHOTO -ELECTRIC WITH DUCT -PROBE) GROUND ROD & CONNECTION THERMOSTAT o-. S FIRE ALARM SMOKE DETECTOR (IONIZATION WITH DUCT -PROBE) TRANSFORMER 0 FLAME DETECTOR ® TIME CLOCK SO I SQ FIRE ALARM SMOKE DETECTOR (IONIZATION) 48V D.C. EMERGENCY LIGHT 0 FIRE ALARM TAMPER SWITCH Q ELECTRICAL DISTRIBUTION PANEL FO FIRE ALARM FLOW SWITCH APPLIANCE PANEL © FIRE FIGHTERS TELEPHONE JACK ® SPECIAL PANEL AS NOTED (ELECT.) FIRE ALARM MAGNETIC DOOR ALARM CONTACTS DH FIRE ALARM MAGNETIC DOOR HOLDER —— CIRCUIT BREAKER COIL (RELAY, CONTACTOR OR CONTROLLER) FIRE ALARM DOOR HOLDER ROUGH -IN— (IN HYDRAULIC DOOR CLOSER) FUSE DD FIRE ALARM BELL/STROBE COMBINATION ___0-i FO— NORMALLY OPEN CONTACTS © FIE] FIRE ALARM STROBE —oho-- NORMALLY CLOSED CONTACTS S❑ ISD FIRE ALARM SPEAKER NORMALLY OPEN MOMENTARY CONTACT ©� FIRE ALARM CHIME __0 L C- NORMALLY CLOSED MOMENTARY CONTACT O I••® FIRE ALARM INDICATING LAMP (REMOTE) �— PILOT LIGHT © FIRE ALARM EMERGENCY PUBLIC TELEPHONE AND CABINET �— SWITCH (MANUAL OR AS NOTED) C L FIRE ALARM CHIME/STROBE COMBINATION TRANSFORMER S L di FIRE ALARM SPEAKER/STROBE COMBINATION FIRE ALARM HORN/STROBE COMBINATION DET SHT DETAIL REFERENCE 01 Ell FIRE ALARM HORN SEC SHT SECTION REFERENCE PROJECT ELECTRICAL GENERAL NOTES 1. VERIFY EXISTING CONDITIONS IN THE FIELD PRIOR TO BIDDING AND BEFORE BEGINNING WORK. 2. REVIEW THE WORK OF OTHER TRADES. COORDINATE AND PLAN WORK WITH THE OTHER TRADES. ADJUST AS A RESULT OF COORDINATION. REVIEW COORDINATED EFFORTS WITH ENGINEER FOR APPROVAL, 3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL CEILING MOUNTED ITEMS. 4. STORE EQUIPMENT AND COMPONENTS IN A CLEAN, DRY LOCATION UNTIL READY FOR INSTALLATION. PROTECT FROM WEATHER, THEFT, DIRT, FUMES, WATER, CONSTRUCTION DEBRIS, ETC. AT ALL TIMES. ANY DAMAGED EQUIPMENT OR COMPONENT SHALL BE RESTORED AS NEW OR REPLACED. 5. ELECTRICAL DRAWINGS SHOW THE INTENDED ARRANGEMENT AND ROUTING OF ALL CONDUIT AND DEVICES. THEY SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING CONSTRUCTION AND WORK OF OTHER TRADES WILL PERMIT. 6. PERFORM ALL WORK IN A SKILLED, PROFESSIONAL, MANNER MEETING THE ACCEPTANCE OF THE ENGINEER, ARCHITECT AND OWNER. 7. LABEL ALL RECEPTACLE DEVICES AS TO WHICH PANEL AND OVERCURRENT DEVICE FEEDS THE DEVICE WITH AN INDELIBLE MARKER ON THE BACK SIDE OF THE COVER PLATE. 8. SMALLEST CONDUIT SIZE ALLOWABLE IS 1/2", AND SMALLEST WIRE SIZE ALLOWABLE IS #12 AWG COPPER UNLESS SPECIFICALLY NOTED OTHERWISE. GROUND ALL CONVENIENCE OUTLETS WITH GREEN GROUND WIRE. 9. MOUNTING HEIGHTS OF DEVICES SHALL FOLLOW THE LISTING BELOW UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS, ALL HEIGHTS ARE TO CENTERLINE OF THE DEVICE. CONVENIENCE OUTLET ....................................................... +18" AFF TELEPHONE OUTLET........................................................... +18" AFF TELEPHONE WALL OUTLET ................................................. +60" AFF DATA OUTLET.................................................................... +18" AFF LIGHT SWITCH OR DIMMER ................................................. +48" AFF DEVICES ABOVE COUNTERTOP .......................................... +44" AFF EXITLIGHT......................................................................... +96" AFF THERMOSTAT OR TEMPERATURE/HUMIDITY SENSOR.........+48" AFF FIRE ALARM PULL STATION .............................................. +48" AFF FIRE ALARM HORN............................................................ +96" AFF FIRE ALARM STROBE........................................................ +80" AFF FIRE ALARM COMBINATION HORN/STROBE...................... +80" AFF FIRE ALARM REMOTE ALARM LAMP ................................. +96" AFF 10. CLEAN ALL EQUIPMENT TO PRESENT A "LIKE NEW" CONDITION AT PROJECT COMPLETION. VACUUM CLEAN INTERNAL AREAS OF EQUIPMENT AND PANELS. 11, CLEAN ALL MECHANICAL AND ELECTRICAL AREAS AND ROOMS OF DEBRIS AND UNUSED MATERIALS. VACUUM FLOORS. 12. THE MOUNTING POSITION FOR ALL STRAIGHT BLADE, VERTICALLY ORIENTED, NEMA 5, 6, 7, 14 AND 15 RECEPTACLES SHALL BE SUCH THAT THE GROUND PIN IS UP (ABOVE PHASE AND NEUTRAL BLADES). THE MOUNTING POSITION FOR ALL STRAIGHT BLADE, HORIZONTALLY ORIENTED, NEMA 5 AND 7 RECEPTACLES SHALL BE SUCH THAT THE NEUTRAL BLADE IS UP (ABOVE THE PHASE BLADE). 13. ALL ABOVE COUNTER DEVICES, LIGHT SWITCHES, RECEPTACLES AND TELE/DATA ROUGH -INS, TO BE MOUNTED AT THE SAME ELEVATION. COORDINATE WITH ARCHITECTURAL CASEWORK ELEVATIONS, SECTIONS AND WALL TYPES. 14. PANELBOARDS SHALL BE DESIGNATED BY; FLOOR/SOURCE/VOLTAGE/RISER/PANEL NUMBER. FLOOR = BUILDING FLOOR PER ARCHITECTURAL DRAWINGS. SOURCE = N FOR NORMAL, E FOR EMERGENCY VOLTAGE = H FOR 480V OR 480/277, L FOR 120/208V RISER = NUMBER RISERS CONSECUTIVELY BEGINNING WITH 1 PANEL = NUMBER PANELS BY FLOOR BEGINNING WITH 1 Owner: CARMEL CITY CENTER COMMUNITY DEVELOPMENT CORPORATION 30 West Main Street, Suite 220 Carmel, Indiana 46032 317.571-2787 Architect: PEDCOR DESIGN GROUP Architecture / Project Management: 355 City Center Drive Carmel, Indiana 46032 317.705.7979 (phone) 317.705.7980 (fax) CIRCLE DESIGN GROUP, INC. 5510 S EAST SHP. 911 F. NBMOPQIi N 16W. (317) 781 -OM 1FATK '011 ATIOK M CM11"A MJPA M. FSE PROTE 04 "AND DECOM DF901 C091IN1M 870242 p'.• STATE OF : t� North (I Parcel 7-C Keyplan N Project: 1 U Lu �t J Q W W U = � 0CO N M Z V o LL! U Q0 Lu < •, MJ Z W W W� V E Z Z CU� 0 0 Z J O Z) LLJ M V Q U J LL J_ LL O COPYRIGHT & OWNERSHIP OF DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTYRIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIORWRITT�,N CONSENT OF THE ARCHITECT, JAMES R. STU7ZMAN AND PEDGOR DE GROUP, LLG. c COPYRIGHT 2006. 2007. 2008. 2009. JAMES R. STUTZMAN. AIA, CARMEL, IN. BID SET No.1 SHELL &CORE Print ate Sheet Issue Date 9/14/09 9/15/09 Drawn By Checked By A. ORBIK J. WYLIE Last Revision Date: Project Number Sheet Title: SYMBOLS, ABBREVIATIONS AND GENERAL NOTES Sheet Number: E001