HomeMy WebLinkAbout922" SYSTEM DRAIN
RISER
EXTERIOR WALL
I
DISCHARGE SYSTEM DRAIN \
TO GRADE. SEAL WALL
PENETRATION WEATHERTIGHT.
GRADE
MECHANICAL
COUPLING
6" INCOMING FIRE PROTECTION —\
WATER SUPPLY
----6" FIRE MAIN TO BUILDING FIRE
PROTECTION STANDPIPE SYSTEM
INDICATING TYPE SPRINKLER ZONE CONTROL
VALVE WITH SUPERVISORY SWITCH
WATERFLOW SWITCH
TO BUILDING FIRE
PROTECTION SYSTEM
���TEST AND DRAIN
< VALVE ASSEMBLY
FROM FIRE DEPARTMENT
CHECK VALVE WITH CONNECTION
AUTOMATIC DRIP
2" AUTOMATIC
SPRINKLER SY`
MAIN DRAIN. S
FLOOR PLANS
EXACT LOCATI(
STAIR 2
RM 104
2 1/2" FIRE DEPARTMENT
VALVE, CAP AND CHAIN.
DOUBLE CHECK VALVE
ASSEMBLY (DCVA
(INSTALLED IN VERTICAL POSITION)
FLANGED
COUPLING
FINISHED FLOOR
CD
I a-
�, w
0
m
a _
SLUSH CONCRETE
REINFORCEMENT
INCOMING FIRE PROTECTION WATER SUPPLY
DETAIL A
NO SCALE
AUTOMATIC SPRINKLER ZONE
CONTROL VALVE
DETAIL B
NO SCALE
IC
YSTEM
SURE GAUGE
GENERAL NOTES:
1. THE BUILDING SHALL BE PROTECTED BY A FULLY AUTOMATIC WET SPRINKLER
SYSTEM.
2. SYSTEM DENSITY COVERAGES AS FOLLOWS:
HAZARD DENSITY AREA HEAD TEMP
LIGHT .10 GPM 1500 FT/2 155' F
ORD GP1 .15 GPM 1500 FT/2 155' F
ORD GP 2 .20 GPM 1500 FT /2 155' F
3. INSTALL SPRINKLER SYSTEM PER NFPA 13.
4. COORDINATE SPRINKLER HEAD LAYOUT WITH ALL OTHER CEILING DEVICES.
5. SUBMIT PLANS TO ARCHITECT/ENGINEER FOR REVIEW PRIOR TO FABRICATION OF SYSTEM.
ARCHITECT/ENGINEER RESERVES THE RIGHT TO ADD SPRINKLER HEADS AND PIPING
OR ADJUST SPRINKLER HEAD LOCATIONS AT NO ADDITIONAL COST TO THE OWNER.
6. SPRINKLERS LOCATED IN FINISHED CEILINGS SHALL BE PENDANT MOUNTED ON CONCEALED
PIPING. SPRINKLERS LOCATED IN BLIND OR FURRED SPACES SHALL BE STANDARD UPRIGHTS
MOUNTED ON RISER NIPPLES. EXTENDED COVERAGE SIDEWALL HEADS SHALL BE USED WHERE
NEEDED. STANDARD UPRIGHT HEADS ON THE REMAINDER OF THE SYSTEM.
PLAN NOTES:
O2 1/2" HOSE VALVE WITH CAP AND CHAIN.
O2 6" INCOMING FIRE PROTECTION WITH VERTICAL DOUBLE CHECK VALVE. 4" STANDPIPE UP
O3 4" STANDPIPE UP. PROVIDE DRAIN VALVE AT THE BOTTOM OF STANDPIPE.
4O PROVIDE WATER CURTAIN WITH CLOSE SPACED SPRINKLERS.
5O FLOOR CONTROL VALVE WITH SUPERVISORY SWITCH.
O6 FLOW SWITCH.
O7 ROUTE SPRINKLER DRAIN TO OUTSIDE.
O2" DRAIN RISER.
FIRE PROTECTION EQUIPMENT SCHEDULE
ITEM
MAKE do MODEL NUMBER
DESCRIPTION
CAPACITY
ELECTRICAL
CHARACTERISTICS
NOTES
(OR APPROVED EQUAL)
DOUBLE CHECK VALVE
WATTS
-
-
-
INCOMING FIRE PROTECTION SERVICE;
ASSEMBLY (DCVA-1)
6" 774 -NRS
-
-
-
INSTALLED IN VERTICAL POSITION
Owner:
CARMEL CITY CENTER
COMMUNITY DEVELOPMENT
CORPORATION
30 West Main Street, Suite 220
Carmel, Indiana 46032
317.571-2787
Architect:
PEDCOR DESIGN GROUP
Architecture / Project Management:
355 City Center Drive
Carmel, Indiana 46032
317.705.7979 (phone)
317.705.7980 (fax)
CIRCLE DESIGN GROUP, INC,
5510 & FAST SIIEFI. 911E F. IUNUM N 16727. j717 731-M
IGiM VDMIXK M C"TMN' PUMN4 FSS AphCMK
LMif111D NO BECOWA DE9M CONW IR
L w
NO.
870242
p'. STATE OF
. F IAN.•••'• �.
BONA
North
(I Parcel 7-C Keyplan
Project:
U W
J Q
W W
I. U =
Q X
N
M
Z V O
W U �
W Q
� m Z
C� 0
W (D E
= z L
0 U
Z J
O
W o0
� w
Q U
J L.L
J
LL
O
COPYRIGHT & OWNERSHIP OF DOCUMENTS
THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE
PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL
INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND
DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS
PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,
INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL
INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND
UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND
PEDCOR DESIGN GROUP, LLG. NO PART OR WHOLE OF THIS DESIGN,
THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR
PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE
DUPLICATED, COPIED, D011BITED, PHOTOGRAPHED, PUBLISHED. MODIFIED
OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND
PRIOR WRI1& CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND
PEDCOR DE N GROUP, LLC. c COPYRIGHT 2006, 2007, 2008, 2008.
JAMES R. STUTZMAN. AIA, CARMEL, IN.
BID SET No.1
SHELL & CORE
Print Date Sheet Issue Date
9/14/09 9/15/09
Drawn By Checked By
A. VEKSLER J. WYLIE
Last Revision Date:
O
O
O
O
O
O
Project Number
Sheet Title:
FIRST FLOOR PLAN -
FIRE PROTECTION
Sheet Number:
FP201