HomeMy WebLinkAbout922" SYSTEM DRAIN RISER EXTERIOR WALL I DISCHARGE SYSTEM DRAIN \ TO GRADE. SEAL WALL PENETRATION WEATHERTIGHT. GRADE MECHANICAL COUPLING 6" INCOMING FIRE PROTECTION —\ WATER SUPPLY ----6" FIRE MAIN TO BUILDING FIRE PROTECTION STANDPIPE SYSTEM INDICATING TYPE SPRINKLER ZONE CONTROL VALVE WITH SUPERVISORY SWITCH WATERFLOW SWITCH TO BUILDING FIRE PROTECTION SYSTEM ���TEST AND DRAIN < VALVE ASSEMBLY FROM FIRE DEPARTMENT CHECK VALVE WITH CONNECTION AUTOMATIC DRIP 2" AUTOMATIC SPRINKLER SY` MAIN DRAIN. S FLOOR PLANS EXACT LOCATI( STAIR 2 RM 104 2 1/2" FIRE DEPARTMENT VALVE, CAP AND CHAIN. DOUBLE CHECK VALVE ASSEMBLY (DCVA (INSTALLED IN VERTICAL POSITION) FLANGED COUPLING FINISHED FLOOR CD I a- �, w 0 m a _ SLUSH CONCRETE REINFORCEMENT INCOMING FIRE PROTECTION WATER SUPPLY DETAIL A NO SCALE AUTOMATIC SPRINKLER ZONE CONTROL VALVE DETAIL B NO SCALE IC YSTEM SURE GAUGE GENERAL NOTES: 1. THE BUILDING SHALL BE PROTECTED BY A FULLY AUTOMATIC WET SPRINKLER SYSTEM. 2. SYSTEM DENSITY COVERAGES AS FOLLOWS: HAZARD DENSITY AREA HEAD TEMP LIGHT .10 GPM 1500 FT/2 155' F ORD GP1 .15 GPM 1500 FT/2 155' F ORD GP 2 .20 GPM 1500 FT /2 155' F 3. INSTALL SPRINKLER SYSTEM PER NFPA 13. 4. COORDINATE SPRINKLER HEAD LAYOUT WITH ALL OTHER CEILING DEVICES. 5. SUBMIT PLANS TO ARCHITECT/ENGINEER FOR REVIEW PRIOR TO FABRICATION OF SYSTEM. ARCHITECT/ENGINEER RESERVES THE RIGHT TO ADD SPRINKLER HEADS AND PIPING OR ADJUST SPRINKLER HEAD LOCATIONS AT NO ADDITIONAL COST TO THE OWNER. 6. SPRINKLERS LOCATED IN FINISHED CEILINGS SHALL BE PENDANT MOUNTED ON CONCEALED PIPING. SPRINKLERS LOCATED IN BLIND OR FURRED SPACES SHALL BE STANDARD UPRIGHTS MOUNTED ON RISER NIPPLES. EXTENDED COVERAGE SIDEWALL HEADS SHALL BE USED WHERE NEEDED. STANDARD UPRIGHT HEADS ON THE REMAINDER OF THE SYSTEM. PLAN NOTES: O2 1/2" HOSE VALVE WITH CAP AND CHAIN. O2 6" INCOMING FIRE PROTECTION WITH VERTICAL DOUBLE CHECK VALVE. 4" STANDPIPE UP O3 4" STANDPIPE UP. PROVIDE DRAIN VALVE AT THE BOTTOM OF STANDPIPE. 4O PROVIDE WATER CURTAIN WITH CLOSE SPACED SPRINKLERS. 5O FLOOR CONTROL VALVE WITH SUPERVISORY SWITCH. O6 FLOW SWITCH. O7 ROUTE SPRINKLER DRAIN TO OUTSIDE. O2" DRAIN RISER. FIRE PROTECTION EQUIPMENT SCHEDULE ITEM MAKE do MODEL NUMBER DESCRIPTION CAPACITY ELECTRICAL CHARACTERISTICS NOTES (OR APPROVED EQUAL) DOUBLE CHECK VALVE WATTS - - - INCOMING FIRE PROTECTION SERVICE; ASSEMBLY (DCVA-1) 6" 774 -NRS - - - INSTALLED IN VERTICAL POSITION Owner: CARMEL CITY CENTER COMMUNITY DEVELOPMENT CORPORATION 30 West Main Street, Suite 220 Carmel, Indiana 46032 317.571-2787 Architect: PEDCOR DESIGN GROUP Architecture / Project Management: 355 City Center Drive Carmel, Indiana 46032 317.705.7979 (phone) 317.705.7980 (fax) CIRCLE DESIGN GROUP, INC, 5510 & FAST SIIEFI. 911E F. IUNUM N 16727. j717 731-M IGiM VDMIXK M C"TMN' PUMN4 FSS AphCMK LMif111D NO BECOWA DE9M CONW IR L w NO. 870242 p'. STATE OF . F IAN.•••'• �. BONA North (I Parcel 7-C Keyplan Project: U W J Q W W I. U = Q X N M Z V O W U � W Q � m Z C� 0 W (D E = z L 0 U Z J O W o0 � w Q U J L.L J LL O COPYRIGHT & OWNERSHIP OF DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLG. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, D011BITED, PHOTOGRAPHED, PUBLISHED. MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRI1& CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DE N GROUP, LLC. c COPYRIGHT 2006, 2007, 2008, 2008. JAMES R. STUTZMAN. AIA, CARMEL, IN. BID SET No.1 SHELL & CORE Print Date Sheet Issue Date 9/14/09 9/15/09 Drawn By Checked By A. VEKSLER J. WYLIE Last Revision Date: O O O O O O Project Number Sheet Title: FIRST FLOOR PLAN - FIRE PROTECTION Sheet Number: FP201