HomeMy WebLinkAbout98iI
11.
OL
L,.`...
�- -
16"0 FLUE UP
:
- - - -- -
SUPPLY RISER
I-- _ - —
(AHU 01) i _ _-
82" X 18"
it
- ---
I--RETURN RISER
(AHU-02)
r
T
56" X 24"
II I
,I I
- I SUPPLY RISER
- - - - - - --- - - I =O -- --- - - - - - -----
-- - - 60" X 26" (
- - - -- AHU-02)
RETURN RISER _ - -- -- .- --
- -- (AHU _3) - -- - -
Y nv.
i FIRE DAMPER AT 290 F'
56" X 32" FLOOR PENTRATION 42" X 42" 18 6
SUPPLY RISER SUPPLY FROM ABOVE - X
12" X 12„ 38 38
(AHU-03) -- - - (AHU-04) - - - - - l 20„ X 8„ --- -- - - -- - - - - -- - - -- - -
11 2"HS&H - - -
_ _ 290 I _ BD
R BD BD BD I 6 FDr
---- -- -- ---- r.
18' X 18'EXHAUST 2" HS & HR HR 1 1/2 HS & HR AD o 0 4-12 12 BD ----' IIAD 54" X 36"
FROM BELOW
22" X 22° _ 3/4" HS HS I---- FDr -- ----I SUSPENDED ' RETURN UP
FCU 3-t
-- AD (AHU-04
--- EXHAUST UP & HR AD np----
_ O .O
2"HS&HR - BD
VAV„ - - - - - - - - - - _ - - - - - - --- - - -- -- - - - - - - - - - - -
0 - - —� - 1 / HS & HR
J ,
12" X 10 4-3 8" X 8" H -7 _ F '� - -� 16" X 12" FLEXIBLE BD -G 75 F 75 �% 38 38 1 2"
-- TO - C CONNECTION 6 / _
;, „ _ F o- 10" X 10" 2" HS & HR HS 1/2" HS & HR - TYPICAL HS
6" X 6" _ BD6
HR
14 X 4A -- CHS CHR CHS HR HR
-�
1
�I
GRILLE WITH OPPOSED
FF VALVE "
H 14" -
10» X 6„ 6502„ X 8 (TYPI-OF 3/4 CHS CHR GRILLE
DAMPER. MOUNT
T VA 14'0 II I _
—' - BD LLE AT THE BOTTOM
_VV//u^\\24010 X 8 E - OF SUPPLY AIR DUCT
„ r 12 1 I 16 1
y-
- ) CHS/CHR
TTM T E _14 X RISER 0
-t S
D-_ --I®
_ VAV-3-2 — D 8D y 240-
- H-12 12 170 F - 10„ X 6„ 8D 3„ (7" OD) HS/HR 42" X 42"
�- 10/6 - -__ - RETURN RISER
� II
E- RISERS (AHU-01)
1 12 14 X 6" 8 D
-1-65
'H D -
- --
1
28 -- - - - - ----- - --- - - - -- --- - - - -- - - - -- - - -- -- - -- - - - -
- - - - - ^--,O --- -- - - - _
Q - - - - -
- - z - - - - -- - - -- - - - - -
THIRD FLOOR PLAN - HVAC
SCALE: 1/8" = 1'-0" %
Owner:
CARMEL CITY CENTER
COMMUNITY DEVELOPMENT
CORPORATION
30 West Main Street, Suite 220
Cannel, Indiana 46032
317.571-2787
Architect:
PEDCOR DESIGN GROUP
Architecture / Project Management:
355 City Center Drive
Carmel, Indiana 46032
317.705.7979 (phone)
317.705.7980 (fax)
CIRCLE DESIGN GROUP, INC.
SIO S EAST SHEET. BATE F. WI N 461 (An IM -M
IEAWN IRInATIM, M OOdi10�1C RJUN I Ra PR01W K
wmw W IIFOIRCN. Dia, OW9 TWM
L w
F y
No.
870242
y p STATE OF °� a
P:
%.S/4NA
North
(±) Parcel 7-C Keyplan
N
Project:
1
U
W
w
I�
W
w
U
=
0.�
N
W%
M
Z
V
�
W
U
Q
W
J
m
Z
—
OZ5
W
O
E
=
Z
i
O
U
Z
J
O
:D
W
0°
O
w
Q,
U
J
LL
J
LL
—
O
COPYRIGHT & OWNERSHIP OF DOCUMENTS
THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE
PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL
INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND
DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS
PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,
INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL
INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND
UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND
PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,
THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR
PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE
DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED
OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND
PRIOR WRFFMN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND
PEDCOR DESIGN GROUP, LLC. c COPYRIGHT 2008, 2007, 2008, 2009,
JAMES R. STUTZMAN, AIA, CARMEL, IN.
BID SET No.1
SHELL & CORE
Print Date Sheet Issue Date
9/14/09 9/15/09
Drawn By Checked By
Y. KITSIS J. WYLIE
Last Revision Date:
O
O
O
O
O
O
Project Number:
Sheet Title:
THIRD FLOOR
PLAN - HVAC
Sheet Number:
H2O3