HomeMy WebLinkAbout36ABBREVIATIONS
A
AMP
AFC
ABOVE FINISHED CEILING
AFF
ABOVE FINISHED FLOOR
AFG
ABOVE FINISHED GRADE
AIC
AMPS INTERRUPTING CAPACITY
ATS
AUTOMATIC TRANSFER SWITCH
AWG
AMERICAN WIRE GAUGE
BFF
BELOW FINISHED FLOOR
BFG
BELOW FINISHED GRADE
C
CONDUIT
cd
CANDELA
CKT
CIRCUIT
CU
COPPER
D
DEEP
DACT
DIGITAL ALARM COMMUNICATOR TERMINAL
DED
DEDICATED CIRCUIT
EG
EQUIPMENT GROUND
EMT
ELECTRICAL METALLIC TUBING
EX
EXISTING
EXT
EXTERIOR
FACP
FIRE ALARM CONTROL PANEL
FAA
FIRE ALARM REMOTE ANNUNCIATOR
FLA
FULL LOAD AMPS
FMC
FLEXIBLE METAL CONDUIT
GEC
GROUNDING ELECTRODE CONDUCTOR
GFCI
GROUND FAULT CIRCUIT INTERRUPTER
H
HIGH
HP
HORSEPOWER
IBC
INTERNATIONAL BUILDING CODE
IG
ISOLATED GROUND
KW
KI LOWATT
MBJ
MAIN BONDING JUMPER
MC
METAL -CLAD CABLE
MCA
MINIMUM CIRCUIT AMPACITY
MCB
MAIN CIRCUIT BREAKER
MDP
MAIN DISTRIBUTION PANEL
MLO
MAIN LUGS ONLY
MOCP
MAXIMUM OVERCURRENT PROTECTION
N
NEUTRAL
NEC
NATIONAL ELECTRICAL CODE
NFPA
NATIONAL FIRE PROTECTION ASSOCIATION
OC
ON CENTER
PC
PHOTOCELL
R
RELOCATED
TCL
TOTAL CONNECTED LOAD
TDL
TOTAL DEMAND LOAD
TVSS
TRANSIENT VOLTAGE SURGE & SPIKE
TYP
TYPICAL
UL
UNDERWRITERS LABORATORIES
UNO
UNLESS NOTED OTHERWISE
UPS
UNINTERRUPTED POWER SUPPLY
WP
WEATHERPROOF
XFMR
TRANSFORMER
ELECTRICAL LEGEND
SINGLE POLE SWITCH, MOUNTED 44" AFF LINO
S MODIFIERS FOR SWITCHES:
3 = THREE WAY
4 = FOUR WAY
DM = DIMMER SWITCH
OC = OCCUPANT SENSOR
DUAL -TECHNOLOGY, CEILING MOUNTED, LOW
VOLTAGE OCCUPANCY SENSOR
O OCCUPANCY SENSOR SWITCHPACK, WIRE PER
MANUFACTURER'S RECOMMENDATIONS.
120V DUPLEX RECEPTACLE, MOUNTED 18" AFF.
UNO MODIFIERS FOR RECEPTACLES:
GFI = GROUND FAULT CIRCUIT INTERRUPTER.
WP = WEATHERPROOF
T 120V SIMPLEX RECEPTACLE, MOUNTED 18" AFF. UNO
Ail
Vic 120V QUAD RECEPTACLE, MOUNTED 18" AFF. UNO
If 220V DUPLEX RECEPTACLE, MOUNTED 18" AFF. UNO
v TELCO OUTLET MOUNTED 18" AFF UNO
V DATA/TELCO OUTLET MOUNTED 18" AFF UNO
❑ PC PHOTOELECTRIC CELL
❑J JUNCTION BOX
FUSED DISCONNECT
❑J UNFUSED DISCONNECT
WIRING SYSTEM -BRANCH OR FEEDER CIRCUIT
-------- WIRING SYSTEM -SWITCHED BRANCH OR FEEDER CIRCUIT
BRANCH OR FEEDER CIRCUIT HOMERUN TO PANELBOARD,
SWITCHBOARD, MOTOR CONTROL CENTER, ETC. SUBSCRIPT
DENOTES PANELBOARD, SWITCHBOARD, MOTOR CONTROL
CENTER, ETC. AND OVERCURRENT PROTECTION DEVICE NUMBER.
i HOMERUN - 120V
hi
HOMERUN - 208V
FIRE ALARM SCHEDULE
SYMBOL
SYMBOL
DESCRIPTION
TYPE OF
FIRE ALARM VOICE/HORN/STROBE LIGHT -WALL MOUNTED
SUCH THAT THE ENTIRE LENS IS NOT LESS THAN 80"
AND NOT GREATER THAN 96" AFF.
WATTS/
MANUAL FIRE ALARM PULL STATION TO BE LOCATED
WITHIN 5 FT OF THE EXIT DOORWAY OPENING
FACP
FIRE ALARM CONTROL PANEL
OSMOKE
DETECTOR
LAMPS
HEAT DETECTOR
S�
SMOKE DUCT DETECTOR
UTILITY TRANSFORMER
208/12OV,30 ,4 -WIRE
1
LIGHT FIXTURE SCHEDULE
SYMBOL
LABEL
# OF
TYPE OF
# OF
WATTS/
VOLTAGE
DESCRIPTION
MANUFACTURER/CATALOG NUMBER
1600A
4 PARALLEL RUNS OF 4-600 kCMIL
LAMPS
LAMP
BALLASTS
FIXTURE
EACH RUN IN A SEPARATE 4" CONDUIT
O
1600A
4 PARALLEL RUNS OF 4-600 kCMIL, 1-4/0 AWG EG
5 PARALLEL RUNS OF 4-500 kCMIL, 1-350 kCMIL EG
V)
V)
EACH RUN IN A SEPARATE 4" CONDUIT
EACH RUN IN A SEPARATE 4" CONDUIT
O
800A
2 PARALLEL RUNS OF 3-600 kCMIL, 1-1/0 AWG EG
2'x4', 3 -LAMP TROFFER WITH PRISMATIC LENS, STEEL
LIGHTOLIER L#
C
EACH RUN IN A SEPARATE 4" CONDUIT
EACH RUN IN A SEPARATE 3" CONDUIT
A
3
T8
1
96
120
340UNOOD
XT2GVOR
m
O
U
FRAM, 4 DEEP
PRIOR APPROVED EQUAL
W
B
2
T8
1
64
120
1'x4', 2 -LAMP ACRYLIC LENS WRAP AROUND
LITHONIA MODEL#
RB232
OR APPROVED EQUAL
U�
C
1
INC
---
150
120
WALL -MOUNTED VAPOR TIGHT UTILITY LIGHT.
LITHONIA MODEL#
OVT 150
00
N
OR APPROVED EQUIVALENT
EB
2
EMERGENCY DOUBLE HEAD LIGHT FIXTURE WITH BATTERY
LITHONIA MODEL#
___
1.5
120
BACKUP
ELM2
OR APPROVED EQUIVALENT
EMR
2
EXTERIOR EMERGENCY LIGHT FIXTURE SUITABLE FOR WET
LITHONIA MODEL#
7 C
___
1.4
120
LOCATION WITH BATTERY BACK UP
AFN
OR APPROVED EQUIVALENT
EX
2
LED
___
0.9
120
LED EMERGENCY EXIT SIGN/LIGHTS WITH DIRECTIONAL
LITHONIA MODEL#
LQM
INDICATOR AND BATTERY BACKUP
OR APPROVED EQUIVALENT
NOTES:
1. CATALOG PART NUMBERS SHOWN ARE FOR DESCRIPTIVE AND QUALITY STANDARDS ONLY, NOT TO BE USED FOR ORDERING WITHOUT VERIFICATION. ENGINEER SHALL NOT BE
RESPONSIBLE FOR MISMATCHED OR INACCURATE PART NUMBERS.
2. EM - EMERGENCY BATTERY BACK UP (USE TWO LAMP EMERGENCY BALLAST WHERE ONLY A SINGLE FIXTURE IS VISIBLE)
NL - NIGHT LIGHT
OR - QUARTZ RE -STRIKE
3. ALL FLUORESCENT LIGHT FIXTURES MUST HAVE INDIVIDUAL DISCONNECTING MEANS LOCATED AT EACH FIXTURE.
4. CONTRACTOR TO PROVIDE LIGHT FIXTURE SHIELDS AS REQUIRED TO PREVENT LIGHT POLLUTION OVER PROPERTY LINE.
ELECTRICAL EQUIPMENT FEEDER SCHEDULE
F171
I �I
ow
COPPER
ALUMINUM
LTJ
UZ
WIRE SIZE
WIRE SIZE
O
1600A
4 PARALLEL RUNS OF 4-600 kCMIL
5 PARALLEL RUNS OF 4-500 kCMIL
Qw
aw
EACH RUN IN A SEPARATE 4" CONDUIT
EACH RUN IN A SEPARATE 4" CONDUIT
O
1600A
4 PARALLEL RUNS OF 4-600 kCMIL, 1-4/0 AWG EG
5 PARALLEL RUNS OF 4-500 kCMIL, 1-350 kCMIL EG
V)
V)
EACH RUN IN A SEPARATE 4" CONDUIT
EACH RUN IN A SEPARATE 4" CONDUIT
O
800A
2 PARALLEL RUNS OF 3-600 kCMIL, 1-1/0 AWG EG
3 PARALLEL RUNS OF 3-400 kCMIL, 1-3/0 AWG EG
C
EACH RUN IN A SEPARATE 4" CONDUIT
EACH RUN IN A SEPARATE 3" CONDUIT
®
200A
4-3/0 AWG, 1-6 AWG EG IN 2" CONDUIT
4-250 kCMIL, 1-4 AWG EG IN 3" CONDUIT
-1.
y
a
w
z
Ld
(n U
Dw
wz
az
o0
O U
1 25
300 KCMIL (CU) MBJ
14"x14"xLENGTH REQUIRED NEMA 1 WIREWAY
3 E4
I �
CT U O I(Wl. 0 0 0 ol(Wi
L"- VJ L� Vi
3 4 T T
owow
F171
I �I
ow
Mm Dib
IL J
LTJ
UZ
(n
WZ
�U
7
LL'U
D
LL -
w
Qw
aw
9 z
oz
Oz
Goo
NO
NO
V)
V)
V)
0
0
0
4 AWG (CU)GEC/3
W
1 -LINE RISER DIAGRAM
SCALE: NTS
FL71
I SIJ
F171
I �I
o �
N
Mm Dib
IL J
LTJ
FUTURE
METERS AND
DISCONNECTS
VERIZON PANERA
HOUSE PANEL PANEL PANEL
'HP' 'VP' 'PP'
GENERAL NOTES
1. ALL ELECTRICAL DEVICES, FIXTURES, EQUIPMENT
AND FEEDERS SHALL BE INSTALLED IN
ACCORDANCE WITH THE PROJECT SPECIFICATIONS,
THE MANUFACTURER'S RECOMMENDED
INSTALLATION PROCEDURES, ALL APPLICABLE
LOCAL AND STATE CODES, AMERICAN DISABILITIES
ACT AND WITH THE 2009 EDITION OF THE
INDIANA ELECTRICAL CODE (2008 EDITION OF THE
NATIONAL ELECTRICAL CODE),
2. PROVIDE ADDITIONAL SUPPORT FOR DEVICES,
FIXTURES, EQUIPMENT AND FEEDERS WHERE THE
BUILDING CONSTRUCTION IS NOT SUITABLE FOR
DIRECT MOUNTING.
3. FIRESTOP, DRAFTSTOP, SMOKESTOP AND/OR
PROTECT THE ANNULAR SPACE AROUND ALL
PENETRATIONS THROUGH WALLS, PARTITIONS,
FLOORS, CEILING, AND ROOFS IN ACCORDANCE
WITH THE REQUIREMENTS OF THE NATIONAL
ELECTRICAL CODE, UL LISTING REQUIREMENT AND
THE APPLICABLE BUILDING CODES. REFER TO THE
ARCHITECTURAL DRAWINGS AND THE OWNER'S
EXISTING AS-BUILT/RECORD DRAWINGS, VERIFY
CONSTRUCTION RATINGS AND PROVIDE
PENETRATION ASSEMBLIES SUITABLE FOR
PARTICULAR CONSTRUCTION.
4. VERIFY CEILING SYSTEMS AND PROVIDE MOUNTING
ACCESSORIES, TRIMS AND ALL REQUIRED
MOUNTING HARDWARE TO SUIT THE PARTICULAR
INSTALLATION.
5, PROTECT EXISTING UNDERGROUND AND BUILDING
INTERIOR UTILITIES DURING CONSTRUCTION.
6. BRANCH CIRCUIT CONDUCTORS SHALL BE 12 AWG
MINIMUM.
7. COORDINATE ANY AND ALL WORK WITH ALL OTHER
TRADES PRIOR TO INSTALLATION SO AS TO AVOID
CONFLICT DURING CONSTRUCTION.
8. ALL PANELS SHALL HAVE TYPED, COMPLETED
DIRECTORIES INDICATING EQUIPMENT SERVED AND
ROOM NUMBER (AS INDICATED ON FINAL BUILDING
ROOM SIGNAGE) OF EQUIPMENT LOCATION, OR
SPARE, OR SPACE.
9. MANUFACTURER'S NAME AND MODEL NUMBER ARE
GIVEN FOR DESCRIPTIVE PURPOSES, TO INDICATE
A QUALITY STANDARD AND ARE NOT INTENDED TO
LIMIT PRODUCTS TO A PARTICULAR
MANUFACTURER. PRODUCTS DEEMED EQUAL AND
APPROVED BY THE DESIGNER WILL BE ACCEPTED.
10. ALL FEEDERS AND CIRCUITRY SHALL BE TORQUED
PER THE PANEL, BREAKER, AND/OR PARTICULAR
EQUIPMENT MANUFACTURER'S SPECIFICATIONS.
11. CIRCUITRY TO SWITCHES, RECEPTACLES, AND ALL
OTHER DEVICES SHALL BE TERMINATED ON THE
DEVICE'S SCREW TERMINALS,
12. MOUNTING HEIGHTS INDICATED ARE TO CENTER
OF DEVICE, OUTLET, FIXTURE, OR EQUIPMENT
UNLESS NOTED OTHERWISE.
13. ALL WIRE TERMINATIONS SHALL BE RATED FOR 75
DEGREE C.
14. ALL CONDUCTORS SHALL HAVE THHN/THWN
INSULATION, UNLESS OTHERWISE NOTED.
15, ALL CONDUIT SHALL BE EMT, LFMC OR USE MC
CABLE, UNLESS OTHERWISE NOTED.
16. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES
AND EQUIPMENT SHALL BE LABEL LISTED BY AN
APPROVED THIRD PARTY TESTING AGENCY.
17. THE CONTRACTOR SHALL CONTACT THE LOCAL
POWER COMPANY AND OBTAIN, IN WRITING, THE
AVAILABLE FAULT CURRENT OF THE UTILITY
TRANSFORMER. THE CONTRACTOR SHALL ENSURE
THAT ALL ELECTRICAL EQUIPMENT HAS AN AMP
INTERRUPTING CAPACITY (AIC) GREATER THAN THE
AVAILABLE FAULT CURRENT AT ANY POINT IN THE
ELECTRICAL DISTRIBUTION SYSTEM.
18. CONNECT EXHAUST FAN CONTROLS TO MOTION
SENSOR POWER PACK
r
o �
N
Mm Dib
r^
CMmkiled By
�j
z
U
w
1 .
_
O
C
C
O
d `
C
•
E
U
z
�_4
W
V
�;
N
m
O
U
V 5
a�
a
W
ti
0 00
U�
�
100M
M �
00
N
r
Mm Dib
C
CMmkiled By
�
p
1 .
_
O
1`
Mm Dib
C
CMmkiled By
�
C+00
_
O
C
C
O
d `
C
•
E
C
=
W
W
V
�;
N
m
=
�
r
r
SO" DMOO
These drawings indicate the general scope of the project
in terms of architectural design concept, the dimensions of
the building, the major architectural elements and the type
of structural, mechanici and electrical systems.
The drawings do not necessarily Indicate or describe all
work required for full performance and completion of the
requirements of the Contract.
On the basis of the general scope Indicated or described,
the trade contractors shall furnish all Items required for the
proper execution and completion of the work.
R�aNlonM
Ong Ti
Mm Dib
Draw By
CMmkiled By
07/06/12
Ong Ti
PBT
PBT
ELECTRICAL
NOTES,
LEGEND 8
RISER
PE1i100268 ?
'* � STASTA OF ? �
q0� :�Dt►►Nj ��i .
DrOWN Nmvdm
ftw amwoOLmE101_1
11140