Loading...
HomeMy WebLinkAbout11CORNER ENC PPULL OSE & GA BOTTOM RAIL 6" TOP RAIL GATE PLAN HINGE HINGE LATCH DOUBLE WIDE GATES CT - 10'.0' MAX LINE POST QUALLY SPACED -(EXCEPT ON CURV S WHERE A MAX. OF 6' WILL BE REQUIRED OR AS NOTED OTHERWISE. FENCE ELEVATION 1-1/2" CLEARANCE TO F.G., 1" MIN. TO CONC. PAVED SURFACE z ] I .-. W FABRIC TYPE: 9G. WARE WITH 2" MESH. N KNUCKLED SELVAGES TOP 0 AND BOTTOM CLJ 1 3/4" SQUARE MESH BLACK CABLE CUP 00 00 PW B M DETAIL 20'-0" ­Ic GATE PLAN 1 5/8 O.D. CHAIN LINK FENCE TO BE PIPE RAIL FLUSH WITH TOP RAIL AND SHALL HAVE KNUCKLED SELVAGES TOP AND BOTTOM CHAIN LINK FENI FABRIC SEE DET AND SITE PLAN ADDITIONAL INFORMATION USE FABRIC UNDER 6' HT. FABRIC 6'-9' HT. W TFOLD FGENCE BBAACCKPSTOPPOSTS PNNETTING D FOUL POLE, FABRIC & FRAME 1 3/4" SQUARE MESH BLACK CABLE CUP 00 00 CORNER, END & 2.875" O.D. SCH. 40 2.875" O.D. SCH. 40 5" O.D. EXTRA STRONG SCH. 80 12" O.D. SCH.80 PULL POST • 16'+ O.C. HORIZONTALLY 1 ,144" O.D. WALL BRACKET ATTACHED TO TOP UNE POST 2.375' O.D. SCH. 40 2.375" O.D. 6" O.D. EXTRA CONNECT TOP RAILS � TO FOUL POST SCH. 40 STRONG SCH. 80 1/4" DIA. WALL CABLE THRU TOP AND BRACE 1,66" O.D. SCH.40 UNLESS NOTED OTHERWISE RAILS WALL CABLE TO TOP OF WALL WALL BRACKET. LACE NET GATE POST FOR 6 J s'—o" • J � BETWEEN ANCHORS WITH LEAF WIDTH: LESS THAN 6' 2.875" O.D. 2.875" O.D. J MORE THAN 6' TO 13' 4" O.D. 4' O.D. SCH. 40 NTS SCH. 40 GRANDSTANDS - SEE ARCHITECTURAL 3" THICK PROTECTIVE PADDING GATE FRAME 1.9" O.D. SCH. 40 1 7i6" 1 7i$" 1 %" FABRIC TO BE ON INSIDE OF BACKSTOP �xxx.xxx-m 6 GA. FABRIC IN BACK PANELS & WIN x X v Y X 1 %. V SOFTBALL BACKSTOP PLAN NTS 4'-2" CONC. FOOTINGS 2 SOFTBALL BACKSTOP ELEVATION NTS BRACKET WELDED TO POLE AND PAINTED TO MATCH OPEN SOCKET 3/4" TIEBACK CABLE (2) FORCED CABLE CLIPS AND THIMBLE 3/4" MAIN CABLE 1/2- DIA. VERTICALE CABLE ® 16'+ O.C. HORIZONTAL 3 BACKSTOP-/ NETTING CAE 33'+ OR 43'+ HIGH (SEE PLAN) 12" DIAMETER SCHEDULE 80 PAINTED STEEL PIPE. ADJUST HEIGHT OF POLES AS REQUIRED TO MAINTAIN 33' NET HEIGHT ABOVE GRADE. SLE TIEBACK NTS FINI ST 2x4" TREATED TO TRENCH DRAIN CONCRETE FOUNDATION REMWWBLE BASEBALL BAITING CAGE MODEL ,#01432 MID -AMERICAN SPORTS ADVANTAGE 800/624-4519 WITH GROUND SLEEVES INSTALLED PER MANUFACTURES RECOMMENDATIONS. GRADE LICAM ce SYNTHEITC TURF AND INFILL 6 . 118 _ 10"X18' DEEP CONTINUOUS CONCRETE CURB BEYOND POST FOUNDAIION 6" MIN. LAYER FREE DRAINING OPEN GRADED I I: {: t ° e IIIIILI STONE BASE 1' DIA, III � -5'-0' SET 61 CONCRETE e a a e r BASE - )R SIZE° - < - e g BATTING CAGE NTS SEE POST BASE DETAIL FOR SIZE FENCE SEAM AIN LINK FENCE DETAIL NTS 3/4" MAIN TOP CABLE FRAME TO BE 1144 O.D. PIPE t CV O D FOUL POLE, FABRIC & FRAME 1 3/4" SQUARE MESH BLACK CABLE CUP 00 00 YELLOW RUST INHIBITING PAINT. NETTING - SEE SPECIFICATIONS 1/2" DIA. VERTICAL CABLE 4'-0' ALL FABRIC TO BE ON FIELD FOUL POLE TO BE 4" O.D. 'T' SHAPED STAINLESS STEEL • 16'+ O.C. HORIZONTALLY 1 ,144" O.D. WALL BRACKET ATTACHED TO TOP CABLE CUP TOP RAIL USED AS FENCE POST ANCHOR PLATE BOLTS AT CORNERS CONNECT TOP RAILS � TO FOUL POST AND ENDS OF WALL. SECURE 1/4" DIA. WALL CABLE THRU R W Z WALL CABLE TO TOP OF WALL WALL BRACKET. LACE NET TENSION WIRE - 3'-6' 6 J s'—o" • J � BETWEEN ANCHORS WITH TO CABLE WITH NYLON TWINE co 1 J CONDUIT CLIPS AT 3'-4' O.C. 11 FOULPOLE NTS GRANDSTANDS - SEE ARCHITECTURAL 3" THICK PROTECTIVE PADDING WITH GROMMET EDGING ATTACHED STAINLESS STEEL ANCHOR PLATE TO BOTTOM CABLING SYSTEM & 'A WITH 1/2- STAINLESS STEEL BOLTS SPIKED TO GROUND THRU GROMMET M ,2 WELDED TO PLATE EDGING _' -- CONCRETE WALL WITH RUBBED FINISH ON EXPOSED FACES FINISH GRADE OF FIELD X64 BARS 012" O.C. EACH WAY a: 2X4 KEY AACONCRETE FOOTING 4-#4 BARS I D COMPACTED SUBGRADE 3' 4 BACKSTOP / NETTING DETAIL NTS ALTERNATE SOFTBALL BACKSTOP NETTING SEE SPECIFICATIONS. PROVIDE ALL HOOKS, CUPS AND LINES NECESSARY FOR COMPLETE INSTALLATION OF NETS. NETTING POLES SHALL BE 12" O.D. NTH 42" DIA. BY 11' DEEP FOOTINGS. #3TIES AT 8" O.C. 18 #8 BARS VERTICALLY SPACED EVENLY 33'+ OR 43'+ HIGH (SEE PLAN) 12" DIAMETER SCHEDULE 80 PAINTED STEEL PIPE. ADJUST HEIGHT OF POLES AS REQUIRED TO MAINTAIN 33' NET HEIGHT ABOVE GRADE. NETTING FINISH GRADE 9010'0" I 0 BATTER'S BATTER'S BOX BOX i� 0 I 0 'HOME PLATE CATCHER'S BOX SOFTBALL 47 HOME PLATE DETAIL NTS •_r'_ i;- y�.V ii' -tee F"i F•- _ F }.:,,;• �''`" i 12" DEPTH HOMEPLATE `" =• "'�r =``*''` MIX 2' AROUND HOMEPLATE AS INDICATED. DELETE SAND BASE ACCORDINGLY. COMPACT TO MANUFACTURERS _ RECOMMENDATIONS 6" DEPTH HOMEPLATE MIX IN BATTER'S BOX AREA. COMPACT PER MANUFACTURER'S INSTRUCTIONS. 8 BATTER'S BOX DETAIL NTS PITCHER'S RUBBER PACK INNER TUBE LINING WITH CLAY MATERIAL. MOUNT FLUSH WITH TOP OF MOUND. SEE SPECS COMPACT 100% PITCHER'S MOUND MIX AROUND PLATE PER MANUFACTURER'S RECOMMENDATIONS CAP END OF FOUL POLE I FRAME TO BE 1144 O.D. PIPE t CV O D FOUL POLE, FABRIC & FRAME O TO BE PAINTED W/2 COATS OF 00 00 YELLOW RUST INHIBITING PAINT. N � I 0 4'-0' ALL FABRIC TO BE ON FIELD FOUL POLE TO BE 4" O.D. SIDE OF POSTS. 11 GA. FABRIC 1 ,144" O.D. 4'-0' 9GA FABRIC, 2" MESH FOUL POLE TO BE TOP RAIL USED AS FENCE POST CONNECT TOP RAILS � TO FOUL POST < R W Z BOTTOM RAIL 4'-0' TENSION WIRE - 3'-6' 6 J s'—o" • J � ro r r L_ 10 - co 1 J 11 FOULPOLE NTS 2"OFMiaX0SLAG SAND OVER 4 OF 8'-O" NO. 53 STONE. .`10' . 12 WARNING TRACK N.T.S. CUT SLIT IN FABRIC AND INSTALL BATTNG CAGE POST SYNTHETIC SURFACE AROUND SYNTHETIC INFIELD TURF BATTING CAGE POST 2x4" TREATED WOOD NAILER STRIP BOLTED TO CONCRETE CURB 1 X12 ADS FLAT PIPE TO PERIMETER DRAIN SYSTEM AT 15' O.C. SEE G2.2 & CONCRETE SEPARATION AND TURF G2.5 FOR PANEL DRAIN LAYOUT. LAY SEE PLAN ATTACHMENT CURB FLAT PIPE OVER PERIMETER DRAIN. 2" EXISTING NATURAL TURF 6" MIN. LAYER FREE DRAINING OPEN GRADED�° oo(� °°�° ° ° 00 o a °_-. STONE BASE 1 DIA. �� o °� �d,�° oo�oo SLOPE SUBGRADE ® 1% —ITf. TO PERIMETER DRAIN _ 3_ b; SECTION 321813 #: 4ffARTONTIN000S SECTION 334600 GEOTEXTILE/ FILTER e - Q -o FABRIC BARRIER 12" DIA. PERFORATED a .. u PIPE PERIMETER DRAIN W INSTALL 1-1/2" DIA. WASHED - DRAINAGE STONE AROUND 12" DIA. PERIMETER DRAIN. 13 SYNTHETIC TURF- UNDERDR AIN @ BATTING CAGE SECTION NOTE: ALL BASES AND PITCHING RUBBER TO BE INSTALLED UNDER OBSERVATION OF TENANT'S GROUNDSKEEPER AND/ OR OWNER'S REPRESENTATIVE. 9 PITCHING RUBBER DETAIL NTS JACK CORBETT ORIGINAL HOLLYWOOD BASE SEE DETAIL FOR INFIELD DESIGN STANCHION GROUND ANCHOR - PROVIDE SLEEVE EXTENSION AS REQUIRED TO PERMIT CONCRETE BASE INSTALLATION INTO I I SUBGRADE CONCRETE FOOTING COMPACTED SUBGRADE NOTE: INSTALLATION TO COMPLY WITH MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS X co W j Ja � a w = Z W�a U a � �a N o �U, >z � =aa �o�C U�z � a LL Ix 0 a cl) U 1� M a W J 8 t CV O D � O 00 00 N � I 0 N N i 1 z m a W J � t O D � W 0 i m z m � WY < R W Z O D 0 Q CHERRY TREE SOFTBALL COIrI O RENOVATIONS 208032.00.00