HomeMy WebLinkAbout211 2 3
I I I
I
I I I
PANEL 1
I I I
l LBR _
MC1 L8 MC1
5
°3
En
A102
9
,n PANEL 4 Lo
- - - -
MC1
CL
3
PANEL 4 aO
J
- t8 - - -
J W
D � PANEL 4 PANEL 8
� a
J
Lu
iT
CL
PANEL 4
m MC1
LS
o
i MC1 PANEL 4 ANEL 6 �Lo
L
MC1 w
L8 ML8 a11R L8
LBR LHB 1 LBR LBR -I
ILEL 1
FIRST FLOOR MASONRY PLAN
1/8' = 1'-0"
1 2 3
I I I
I I
I I I
SECOND FLOOR MASONRY PLAN
1/8* = 1'-0"
PLAN NOTES:
1. SEE THIS SHEET FOR MASONRY NOTES AND REINFORCING REQUIREMENTS
2. SEE S3.1 THROUGH S3.3 FOR TYPICAL MASONRY DETAILS. TYPICAL DETAILS MR
NOT BE CUT ON PLANS, BUT APPLY UNLESS OTHERWISE NOTED.
3. CJ INDICATES CONTROL JOINT IN CMU. COORDINATE LOCATION WITH BONDING
PATTERN AND WALL ELEVATION. (SEE 1-S3.2)
4. SEE THE PROJECT MANUAL FOR ADDITIONAL CONTROL JOINT LOCATION
REQUIREMENTS
5. SEE 11-S3.2 FOR STEPPED BOND BEAM
6. MC1, MC2, ETC INDICATES MASONRY COLUMN. SEE 4-S3.3
7. SEE 4-S3.2 FOR STEEL LINTEL SCHEDULE. VERIFY MASONRY OPENING AND
ELEVATION WITH ARCHITECTURAL PLANS
8. SEE 2-S3.2 FOR CMU LINTEL SCHEDULE. VERIFY MASONRY OPENING AND
ELEVATION WITH ARCHITECTURAL PLANS
9. BP1, BP2, ETC INDICATES BEARING PLATE REQUIRED. SEE 4-S2.2
10. FOR MULTI -SPAN CONTINUOUS LINTELS, MAINTAIN 16" MINIMUM CMU BETWEEN
OPENINGS (UON)
11. PANEL 1, PANEL 2, ETC., INDICATES MASONRY PANEL SEE THIS SHEET FOR
MASONRY PANEL SCHEDULE
12. LINTEL LEGEND:
* INDICATES LINTEL REQUIRED FOR MECHANICAL OPENING. ONLY A
PORTION OF THESE LINTELS REQUIRED FOR MASONRY OPENINGS
ARE SHOWN ON THE PLANS. THE CONTRACTOR IS REQUIRED TO
FURNISH AND INSTALL ALL LINTELS REQUIRED FOR MECHANICAL
OPENINGS WHETHER OR NOT SHOWN ON THE PLANS. COORDINATE
NUMBER, SIZE, ELEVATION, AND LOCATION OF ALL LINTELS FOR
MECHANICAL OPENINGS.
A. SEE 2-S3.2 AND 4-S3.2 FOR LINTELS IN NON-BEARING
WALLS
B. SUBMIT SHOP DRAWINGS FOR REVIEW OF LINTELS REQUIRED
AT MECHANICAL OPENINGS IN BEARING WALLS AND OUTSIDE
LIMITS OF 2-S3.2 AND 4-S3.2
13. PROVIDE LINTEL AT RECESSED FIRE EXTINGUISHER CABINET.
SEE 2-S3.3. VERIFY MASONRY OPENING AND ELEVATION WITH ARCHITECTURAL
PLANS.
14. PROVIDE LINTEL AT RECESSED ELECTRICAL PANEL BOARD.
SEE 3-S3.3. VERIFY MASONRY OPENING AND ELEVATION.
REQUIRED INSPECTIONS
FREQUENCY
REFERENCE
1. AS MASONRY CONSTRUCTION BEGINS, VERIFY
COMPLIANCE OF THE FOLLOWING WITH THE
CONSTRUCTION DOCUMENTS AND REVIEWED
SUBMITTALS
A. PROPORTIONS OF SITE PREPARED MORTAR
PERIODIC
ACI 530.1 ARTICLE 2.6A
B. CONSTRUCTION OF MORTAR JOINTS
PERIODIC
ACI 530.1 ARTICLE 3.3B
C. LOCATION OF REINFORCEMENT,
PERIODIC
ACI 530.1 ARTICLE 3.4
CONNECTORS, AND ANCHORS
8
2. VERIFY THE FOLLOWING:
A. SIZE AND LOCATION OF STRUCTURAL
PERIODIC
ACI 530.1 ARTICLE 3.3G
ELEMENTS
8
5
B. ANCHOR TYPE, SIZE, AND LOCATION,
PERIODIC
ACI 530 SECTIONS
INCLUDING DETAILS OF ANCHORAGE OF
4
1.2.2 (e), 2.14, 3.16
MASONRY TO STRUCTURAL MEMBERS,
48
110'-0", 114'-8"
FRAMES, OR OTHER CONSTRUCTION
-
5
C. REINFORCEMENT SIZE, GRADE, AND TYPE
PERIODIC
ACI 530 SECTION 1.13
CONFORMS TO SPECIFICATIONS
NOTE 1, 8
ACI 530.1 ARTICLE 2.4, 3.4
D. WELDING OF REINFORCEMENT AND
CONTINUOUS
ACI 530 SECTIONS
HEADED STUD ANCHORS
110'4"
2.1.10.7.2, 3.3.3.4 (b)
E. PROTECTION OF MASONRY DURING COLD
PERIODIC
ACI 530.1 ARTICLE 1.8C
WEATHER (TEMPERATURE BELOW 40 F)
24
IBC 2104.3
F. PROTECTION OF MASONRY DURING HOT
PERIODIC
ACI 530.1 ARTICLE 1.8D
WEATHER (TEMPERATURE ABOVE 90'F)
5
IBC 2104.4
3. PRIOR TO GROUTING, VERIFY THE FOLLOWING:
A. GROUT SPACE IS CLEAN
PERIODIC
ACI 530.1 ARTICLE 3.2D
B. PLACEMENT OF REINFORCEMENT AND
PERIODIC
ACI 530 SECTION 1.13
DEVICES TO HOLD REINFORCEMENT IN
NOTE 1, 8
ACI 530.1 ARTICLE 3.4
PLACE DURING GROUTING
8
5
C. PROPORTIONS OF SITE -PREPARED GROUT
PERIODIC
ACI 530.1 ARTICLE 2.6B
D. CONSTRUCTION OF MORTAR JOINTS
PERIODIC
ACI 530.1 ARTICLE 3.38
4. VERIFY GROUT PLACEMENT CONFORMS WITH
CONTINUOUS
ACI 530.1 ARTICLE 3.5
CODE AND THE CONSTRUCTION DOCUMENTS
11-S2.2
12
5. OBSERVE PREPARATION OF GROUT SPECIMENS,
CONTINUOUS
ACI 530.1 ARTICLE 1.4
MORTAR SPECIMENS, AND/OR PRISMS
NOTE 1
IBC 2105.2.2
6. COMPLIANCE WITH INSPECTION PROVISIONS OF
PERIODIC
ACI 530.1 ARTICLE 1.5
CONSTRUCTION DOCUMENTS AND CODES AND
110'-0"
NOTE 1
APPROVED SUBMITTALS
THE INTERNATIONAL BUILDING CODE REQUIRES A SPECIAL INSPECTOR TO OBSERVE THE WORK
ASSIGNED FOR THE CONFORMANCE TO THE APPROVED DESIGN DRAWINGS AND THE PROJECT
MANUAL THE SERVICES OF A CERTIFIED SPECIAL INSPECTOR SHALL BE MAINTAINED DURING
CONSTRUCTION ON THE TYPES OF WORK LISTED
2
PANEL
MARK
CMU
THICKNESS
(BACK-UP)
VERTICAL
RE1NF
HORIZONTAL REINFORCING
REMARKS
DETAIL
TOP BOND BEAM ELEVATIONS
N
SPA
1
8
9SIZE
48
110'-0", 114'-8", 118'-0", 126'-0"
NOTE 12
8
48
110'-0", 114'-8", 118'-0", 126'-0"
NOTE 1
-
3
8
5
24
108'-8"
NOTE 1, 8
9-A1.3
4
8
5
48
110'-0", 114'-8"
NOTE 1, 8
-
5
8
5
48
110'-0", 114'-8"
NOTE 1, 8
7-S2.2 SIM
6
8
5
48
110'4"
NOTE 1
-
7
8
7
24
110'-0", 114'-8", 118'-0",
126'-0*, 128'-0*
NOTE 1, 8
1-A10.1
8
8
5
48
110'-0", 114'-8", 118'-0", 126'-0"
NOTE 1
4-S2.3
9
8
5
48
110'-0", 114'-8", 118'-0", 126'-0"
NOTE 1, 8
2-S2.3
10
8
5
48
110'-0", 114'-8", 118'-0", 126'-0"
NOTE 1, 8
2-S2.3
11
8
5
48
114'-8", 119'-4"
NOTE 1, 9
11-S2.2
12
8
5
24
108'-8"
NOTE 1
9-A1.3
13
8
5
1 24
110'-0"
NOTE 1
9-A1.3
MASONRY WALL PANEL SCHEDULE
1
MANDATORY INSPECTION FOR
MASONRY CONSTRUCTION
NOTES:
1. MASONRY INSPECTION REQUIRED FOR ALL REINFORCED WALLS (SEE THE PROJECT MANUAL).
2. SEE THE PROJECT MANUAL FOR SIZE AND SPACING OF HORIZONTAL JOINT REINFORCING.
3. REINFORCING SCHEDULED HEREIN APPLIES TO THAT PORTION OF THE WALL ABOVE THE
FOUNDATION WALL SEE FOUNDATION PLANS FOR FOUNDATION WALL REINFORCING.
4. ALL MASONRY WALLS TO HAVE BOND BEAM AT TOP OF WALL
5. ALL MASONRY WALLS ON FOUNDATIONS (INTERIOR AND EXTERIOR) SHALL BE REINFORCED WITH
#5 AT 48" C TO C UNLESS OTHERWISE NOTED.
6. CMU THICKNESS INDICATED IN SCHEDULE MAY NOT APPLY AT BOTTOM OF WINDOW OPENIINGS
(SEE ARCHITECTURAL DETAILS).
7. CMU THICKNESS INDICATED IN SCHEDULE MAY NOT APPLY AT TOP OF WALL ABOVE ROOF UNE
(SEE STRUCTURAL FRAMING DETAILS).
8. GROUT SOLID ABOVE LAST NOTED BOND BEAM TO UNDER SIDE OF DECK.
9. MASONRY WALL BEYOND STAIR LIMITS STOPS AT THE UNDER SIDE OF DECK.
2 3 4 NOTE:
REFER TO SITE PLANS FOR
I I I I BUILDING ORIENTATION
1. ALL CONCRETE MASONRY SHALL CONFORM WITH ASTM C90 HOLLOW LOAD BEARING (HL) UNITS WITH
A COMPRESSIVE STRENGTH OF 1900 PSI ON THE NET SECTION (F'm = 1500 PSI)
2. ALL MORTAR SHALL CONFORM WITH ASTM C270. SEE THE PROJECT MANUAL
3. ALL GROUT SHALL CONFORM WITH ASTM C476 AND HAVE AN AVERAGE COMPRESSIVE STRENGTH OF
2500 PSI AT 28 DAYS. SEE THE PROJECT MANUAL CONCRETE SHALL NOT BE USED IN LIEU OF
MASONRY GROUT.
4. UNLESS OTHERWISE NOTED, CENTER ALL VERTICAL REINFORCING IN CMU CORE AND HOLD IN POSITION
WITH CAGING DEVICES. SEE TYPICAL DETAIL AND SEE THE PROJECT MANUAL
5. THE MINIMUM LENGTH OF LAP FOR REINFORCING IN MASONRY WALLS UNLESS OTHERWISE NOTED
SHALL BE AS FOLLOWS:
BAR NO LAE
4 24"
5 30"
6 36"
7 42"
6. SEE THE PROJECT MANUAL FOR HORIZONTAL JOINT REINFORCING SIZE AND SPACING.
7. ALL BOND BEAMS SHALL BE CONTINUOUS AND SHALL BE FILLED WITH GROUT AND REINFORCED AS
FOLLOWS:
BOND BEAM REINFORCING
8" CMU 2-#5
REINFORCING SHALL BE CONTINUOUS UNLESS OTHERWISE NOTED. PROVIDE DOWELS AT
CORNERS TO MAINTAIN CONTINUOUS REINFORCING. SEE TYPICAL DETAILS.
8. GROUT SHALL BE PLACED IN THE VERTICAL CORES OF THE MASONRY UNITS UTILIZING THE LOW UFT
GROUTING METHOD SET FORTH IN NCMA-TEK 23A.
A. GROUT SHALL COMPLY WITH ASTM C476. (MORTAR OR CONCRETE SHALL NOT BE USED
TO FILL CMU CORES.) SEE THE PROJECT MANUAL
B. WEBS ADJACENT TO CORES TO BE GROUTED SHALL BE MORTARED. MORTAR SHALL BE
STRUCK FLUSH WITH THE INSIDE FACE OF CORES TO BE GROUTED. CORES TO BE
GROUTED SHALL BE CLEANED OF ALL MORTAR DROPPINGS AND OTHER DEBRIS PRIOR TO
GROUTING.
C. THE MAXIMUM HEIGHT OF A GROUT LIFT SHALL BE 4 FEET.
D. STOP GROUT POURS 1 1/2 INCHES BELOW THE UPPERMOST PORTION OF THE CAVITY
BEING FILLED TO PROVIDE A KEY FOR THE NEXT LIFT OR POUR.
E. CONSOLIDATE GROUT BY VIBRATING WITH A MECHANICAL VIBRATOR EACH LIFT,
APPROXIMATELY 20 MINUTES AFTER GROUT IS INSTALLED.
F. ALL REINFORCING STEEL SHALL BE INSPECTED IN PLACE BEFORE GROUTING AND THERE
SHALL BE CONTINUOUS INSPECTION DURING THE GROUTING OPERATION.
9. IN EXTERIOR WALLS PLACE ONE REINFORCING BAR (SAME SIZE AS IN ADJACENT WALL) IN GROUTED
CORE EXTENDING FULL HEIGHT OF WALL FOR ALL WINDOW AND DOOR OPENINGS UP TO 8 FEET
WIDE. FOR OPENINGS 8 FEET TO 16 FEET WIDE PLACE TWO REINFORCING BARS IN TWO GROUTED
CORES EACH SIDE OF OPENING.
10. GROUT CMU CORES 2 COURSES BELOW BEARING OF ALL SCHEDULED STEEL LINTELS AS INDICATED IN
THE STEEL LINTEL SCHEDULE AND 'L' SERIES CMU LINTELS AS SHOWN IN THE CMU LINTEL
SCHEDULE.
GROUT CMU CORES FULL HEIGHT BELOW BEARING OF SPECIAL LINTELS (SL -1, ETC) AS INDICATED IN
THE SPECIAL LINTEL SCHEDULE AND ALL 'ML' AND 'HL' SERIES CMU LINTELS AS SHOWN ON THE
CMU LINTEL SCHEDULE.
11. MASONRY WALLS SHOWN ON ARCHITECTURAL DRAWINGS BUT NOT ON STRUCTURAL MASONRY PLAN
SHALL HAVE HORIZONTAL JOINT REINFORCING AS REQUIRED BY THE PROJECT MANUAL
12. ALL MASONRY WALLS (INTERIOR AND EXTERIOR) SHALL BE ANCHORED TO STEEL COLUMNS AND
BEAMS WHICH DIRECTLY ABUT THE ENDS OR SIDES OF THE WALL. MASONRY WALLS SHALL ALSO BE
ANCHORED TO STEEL LINTELS. SEE THE PROJECT MANUAL
13. PROVIDE ONE VERTICAL REINFORCING BAR (SAME SIZE AS ADJACENT WALL) FULL HEIGHT OF THE
WALL AT CORNERS, INTERSECTIONS, WALL ENDS, BEAM BEARINGS, JAMBS, AND EACH SIDE OF
CONTROL JOINTS IN ALL INTERIOR AND EXTERIOR WALLS ON FOUNDATIONS UNLESS OTHERWISE NOTED.
14. SUBMIT SHOP DRAWINGS DETAILING ALL REINFORCING STEEL IN REINFORCED MASONRY CONSTRUCTION
INCLUDING DETAILS OF ALL BENT BARS, VERTICAL REINFORCING AND HORIZONTAL BOND BEAM
REINFORCING. INCLUDE PLANS AND ELEVATIONS AS REQUIRED TO CLEARLY SHOW ALL REINFORCING,
INCLUDING BOND BEAMS, MASONRY LINTELS, AND ALL VERTICAL BARS.
15. ALL HORIZONTAL JOINT REINFORCING SHALL BE CONTINUOUS THROUGH ALL CORNERS AND
INTERSECTIONS, EXCEPT AT CONTROL JOINTS. USE PREFORMED CORNER AND INTERSECTION
SECTIONS FURNISHED BY JOINT REINFORCING SUPPLIER.
1 MASONRY NOTES
T T T
DUGOUT MASONRY PLAN
1/8" = 1'-0"
DUGOUT MASONRY PLAN
1/8* = 1'-O"
NOTE:
WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK
ON THE PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF
ALL DIMENSIONS AND DETAILS WITH THE ARCHITECTURAL DRAWINGS PRIOR TO
CONSTRUCTION. RESOLVE ANY DISCREPANCIES WITH THE ARCHITECT PRIOR TO
E
M
r
M
co
FABRICATION OR INSTALLATION. TYPICAL DETAILS MAY NOT NECESSARILY BE CUT ON
THE PLANS BUT APPLY UNLESS OTHERWISE NOTED. WHERE DISCREPANCIES OCCUR CHERRY TREE SOFI IALL COMPLEX RENOVATIONS
BETWEEN THE PLANS, DETAILS, AND THE PROJECT MANUAL, THE GREATER
REQUIREMENT SHALL GOVERN. 208032.00.00
G Z'
N
-
.� ]
i
111111
E
M
r
M
co
FABRICATION OR INSTALLATION. TYPICAL DETAILS MAY NOT NECESSARILY BE CUT ON
THE PLANS BUT APPLY UNLESS OTHERWISE NOTED. WHERE DISCREPANCIES OCCUR CHERRY TREE SOFI IALL COMPLEX RENOVATIONS
BETWEEN THE PLANS, DETAILS, AND THE PROJECT MANUAL, THE GREATER
REQUIREMENT SHALL GOVERN. 208032.00.00