HomeMy WebLinkAbout24---------------------------------I
SECOND FLOOR CODE PLAN
1/8" = 1'-0"
- ------ ----- / .. -----. _ ...-...-- _. --- - --- ---------- --
,.
-- - --- ------- -- - ----- --
PLAN LEGEND
EAS — TO EXTEND TO THE FLOOR/ROOF DECK
90 — - INDICATES 2 HOUR FIRE-RESISTANT
RATED SHAFT OR FIRE BARRIER WITH
90 MINUTE RATED OPENING PROTECTIVES,
SECTION 706
- - - INDICATES 1 HOUR FIRE-RESISTANT RATED
SHAFT AND/OR EXIT ENCLOSURE FIRE BARRIER
WITH 1 HOUR RATED OPENING PROTECTIVES,
SECTION 706
EOU8
■ ■ ■ - INDICATES NON FIRE-RESISTANT RATED WALL
THAT EXTENDS TO THE BOTTOM OF ROOF JOISTS
OR FLOOR STRUCTURE ABOVE.
- s - - INDICATES INCIDENTAL USE AREA PARTITION
WITH CONSTRUCTION CAPABLE OF RESISTING THE
PASSAGE OF SMOKE THAT EXTENDS TO THE
FLOOR DECK ABOVE AND HAS SELF CLOSING
AND/OR AUTOMATIC CLOSING DOORS WITH
SMOKE DETECTORS. (SECTION 508.2 AND TABLE
508.2)
INDICATES 1 UFIRE-RESISTANT
BULKHEAD/CEIUNG.(SECTION 10 9ARATED�
5.3)
- INDICATES 2 HOUR FIRE-RESISTANT RATED
- - - - - - CONCRETE DECK ABOVE ELEVATOR SHAFT.
(SECTION 1009.5.3)
FIRST FLOOR CODE PLAN
1/8" = 1'-0"
ROOM LEGEND - UNIT A
3Z#Ir
NO.
ROOM NAME
AREA
JCLNG HT
A201
VARSITY PRESSBOX
409 SF
9'-11"
A202
JR VARSITY PRESSBOX
214 SF
9'-11"
A203
PASSAGE
226 SF
9'-11"
A204
OFFICE
168 SF
9'-11"
A205
LOCKER ROOM
614 SF
9'-11"
A206
RESTROOM
52 SF
9'-11"
A207
STORAGE
35 SF
9'-11"
A208
VESTIBULE
77 SF
9'-11"
AS1
STAIRS
148 SF
9'-11"
ROOM LEGEND - UNIT A
NO.
ROOM NAME
AREA
ICLNG HT
A101
CUSTODIAN/STORAGE
213 SF
VARIES
A102
ELEV. MECH.
51 SF
10'-0"
A103
LOBBY
121 SF
10'-0"
A104
CONCESSIONS
278 SF
10'—O"
A105
WOMENS RESTROOM
431 SF
10'-0"
A106
MENS RESTROOM
316 SF
10'-0"
A107
MECHANICAL/ELEC.
174 SF
EXP.
A108
FAMILY RESTROOM
65 SF
10'-0"
A109
STORAGE
109 SF
10'-0"
AS1
STAIRS
98 SF
—
- BUILDING CODE NOTES
A. ALL INFORMATION IS BASED ON THE FOLLOWING CODES:
2008 INDIANA BUILDING CODE (2006 INTERNATIONAL
BUILDING CODE)
2008 INDIANA FIRE CODE (2006 INTERNATIONAL BUILDING
CODE)
AMERICANS WITH DISABILITIES ACT GUIDELINES (ADAAG) AND
ICC/ANSI A117.1-2003
B. USE AND OCCUPANCY CLASSIFICATION INTERNATIONAL
BUILDING CODE CHAPTER 3:
A5, B, S NON—SEPARATED OCCUPANCIES (SECTION
508.3.2).
C. INCIDENTAL USE AREAS INTERNATIONAL BUILDING CODE
CHAPTER 5:
STORAGE ROOMS OVER 100 SF SHALL BE SEPARATED
FROM THE REMAINDER OF THE BUILDING BY
CONSTRUCTION CAPABLE OF RESISTING THE PASSAGE
OF SMOKE (SECTION 508.2 AND TABLE 508.2).
D. GENERAL BUILDING HEIGHT AND AREAS INTERNATIONAL
BUILDING CODE CHAPTER 5:
ALLOWABLE HEIGHT: 1 STORY (TABLE 503) INCREASE
TO 2 STORY FOR INSTALLATION OF SPRINKLER
SYSTEM (SECTION 504.2).
ALLOWABLE AREA PER FLOOR: 9,000 SF (TABLE 503)
ACTUAL AREA (PRESS BOX BUILDING)
FIRST FLOOR 2,304 SF
SECOND FLOOR 2,304 SF
ACTUAL AREA
DUGOUTS 500 SF EACH (8 TOTAL)
E. TYPE OF CONSTRUCTION INTERNATIONAL BUILDING CODE
CHAPTER 6:
TYPE VB, UNPROTECTED
F. FIRE RESISTANCE RATED CONSTRUCTION INTERNATIONAL
BUILDING CODE CHAPTER 7:
ALL ANNULAR SPACE AT FLOOR PENETRATIONS
AND FLOOR OPENINGS SHALL BE FILLED WITH AN
APPROVED NON—COMBUSTIBLE MATERIAL TO RESIST
THE FREE PASSAGE OF FLAME AND THE PRODUCT
OF COMBUSTION (SECTION 712.4.2.1).
G. INTERIOR FINISHES SHALL COMPLY WITH INTERNATIONAL
BUILDING CODE CHAPTER 8.
H. FIRE PROTECTION SYSTEMS INTERNATIONAL BUILDING CODE
CHAPTER 9:
THE ENTIRE PRESS BOX BUILDING SHALL BE
EQUIPED THROUGHOUT WITH AN APPROVED
AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE
WITH CHAPTER 9 OF THE IBC.
I. MEANS OF EGRESS INTERNATIONAL BUILDING CODE CHAPTER
10:
O
ar
W
H
O
co
co
<
W
39
O
O
rc
�m
H
Z
d
v
X co
W j
0.W = Z
w�¢ U Q
w 0 a �
D
�U, }Z
��
JV W
=Qa J OAC
Utz WQ
LLQ � U
0 Q
(n U
Z Z
J ILJ
IL
W p
100
00
V
Q
O p
O _j
F
�O
g
Lu
S
CV
O
ao 00
N C)
I
N
N
CV
0
0 <
00
so
ca
r
Z
0
Q
c+�
T
O
a
CHERRY TREE SOFTBALL COMPLEX INNOVATIONS
208032.00.00