HomeMy WebLinkAbout24---------------------------------I SECOND FLOOR CODE PLAN 1/8" = 1'-0" - ------ ----- / .. -----. _ ...-...-- _. --- - --- ---------- -- ,. -- - --- ------- -- - ----- -- PLAN LEGEND EAS — TO EXTEND TO THE FLOOR/ROOF DECK 90 — - INDICATES 2 HOUR FIRE-RESISTANT RATED SHAFT OR FIRE BARRIER WITH 90 MINUTE RATED OPENING PROTECTIVES, SECTION 706 - - - INDICATES 1 HOUR FIRE-RESISTANT RATED SHAFT AND/OR EXIT ENCLOSURE FIRE BARRIER WITH 1 HOUR RATED OPENING PROTECTIVES, SECTION 706 EOU8 ■ ■ ■ - INDICATES NON FIRE-RESISTANT RATED WALL THAT EXTENDS TO THE BOTTOM OF ROOF JOISTS OR FLOOR STRUCTURE ABOVE. - s - - INDICATES INCIDENTAL USE AREA PARTITION WITH CONSTRUCTION CAPABLE OF RESISTING THE PASSAGE OF SMOKE THAT EXTENDS TO THE FLOOR DECK ABOVE AND HAS SELF CLOSING AND/OR AUTOMATIC CLOSING DOORS WITH SMOKE DETECTORS. (SECTION 508.2 AND TABLE 508.2) INDICATES 1 UFIRE-RESISTANT BULKHEAD/CEIUNG.(SECTION 10 9ARATED� 5.3) - INDICATES 2 HOUR FIRE-RESISTANT RATED - - - - - - CONCRETE DECK ABOVE ELEVATOR SHAFT. (SECTION 1009.5.3) FIRST FLOOR CODE PLAN 1/8" = 1'-0" ROOM LEGEND - UNIT A 3Z#Ir NO. ROOM NAME AREA JCLNG HT A201 VARSITY PRESSBOX 409 SF 9'-11" A202 JR VARSITY PRESSBOX 214 SF 9'-11" A203 PASSAGE 226 SF 9'-11" A204 OFFICE 168 SF 9'-11" A205 LOCKER ROOM 614 SF 9'-11" A206 RESTROOM 52 SF 9'-11" A207 STORAGE 35 SF 9'-11" A208 VESTIBULE 77 SF 9'-11" AS1 STAIRS 148 SF 9'-11" ROOM LEGEND - UNIT A NO. ROOM NAME AREA ICLNG HT A101 CUSTODIAN/STORAGE 213 SF VARIES A102 ELEV. MECH. 51 SF 10'-0" A103 LOBBY 121 SF 10'-0" A104 CONCESSIONS 278 SF 10'—O" A105 WOMENS RESTROOM 431 SF 10'-0" A106 MENS RESTROOM 316 SF 10'-0" A107 MECHANICAL/ELEC. 174 SF EXP. A108 FAMILY RESTROOM 65 SF 10'-0" A109 STORAGE 109 SF 10'-0" AS1 STAIRS 98 SF — - BUILDING CODE NOTES A. ALL INFORMATION IS BASED ON THE FOLLOWING CODES: 2008 INDIANA BUILDING CODE (2006 INTERNATIONAL BUILDING CODE) 2008 INDIANA FIRE CODE (2006 INTERNATIONAL BUILDING CODE) AMERICANS WITH DISABILITIES ACT GUIDELINES (ADAAG) AND ICC/ANSI A117.1-2003 B. USE AND OCCUPANCY CLASSIFICATION INTERNATIONAL BUILDING CODE CHAPTER 3: A5, B, S NON—SEPARATED OCCUPANCIES (SECTION 508.3.2). C. INCIDENTAL USE AREAS INTERNATIONAL BUILDING CODE CHAPTER 5: STORAGE ROOMS OVER 100 SF SHALL BE SEPARATED FROM THE REMAINDER OF THE BUILDING BY CONSTRUCTION CAPABLE OF RESISTING THE PASSAGE OF SMOKE (SECTION 508.2 AND TABLE 508.2). D. GENERAL BUILDING HEIGHT AND AREAS INTERNATIONAL BUILDING CODE CHAPTER 5: ALLOWABLE HEIGHT: 1 STORY (TABLE 503) INCREASE TO 2 STORY FOR INSTALLATION OF SPRINKLER SYSTEM (SECTION 504.2). ALLOWABLE AREA PER FLOOR: 9,000 SF (TABLE 503) ACTUAL AREA (PRESS BOX BUILDING) FIRST FLOOR 2,304 SF SECOND FLOOR 2,304 SF ACTUAL AREA DUGOUTS 500 SF EACH (8 TOTAL) E. TYPE OF CONSTRUCTION INTERNATIONAL BUILDING CODE CHAPTER 6: TYPE VB, UNPROTECTED F. FIRE RESISTANCE RATED CONSTRUCTION INTERNATIONAL BUILDING CODE CHAPTER 7: ALL ANNULAR SPACE AT FLOOR PENETRATIONS AND FLOOR OPENINGS SHALL BE FILLED WITH AN APPROVED NON—COMBUSTIBLE MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND THE PRODUCT OF COMBUSTION (SECTION 712.4.2.1). G. INTERIOR FINISHES SHALL COMPLY WITH INTERNATIONAL BUILDING CODE CHAPTER 8. H. FIRE PROTECTION SYSTEMS INTERNATIONAL BUILDING CODE CHAPTER 9: THE ENTIRE PRESS BOX BUILDING SHALL BE EQUIPED THROUGHOUT WITH AN APPROVED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH CHAPTER 9 OF THE IBC. I. MEANS OF EGRESS INTERNATIONAL BUILDING CODE CHAPTER 10: O ar W H O co co < W 39 O O rc �m H Z d v X co W j 0.W = Z w�¢ U Q w 0 a � D �U, }Z �� JV W =Qa J OAC Utz WQ LLQ � U 0 Q (n U Z Z J ILJ IL W p 100 00 V Q O p O _j F �O g Lu S CV O ao 00 N C) I N N CV 0 0 < 00 so ca r Z 0 Q c+� T O a CHERRY TREE SOFTBALL COMPLEX INNOVATIONS 208032.00.00