Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
48
TRANSITION TO FAN AS REQUIRED 1 ALUMINL BIRDSCREEt COUNTER FLASHING BY 01 16" HI( PRE—F) PROVIDE OPENING THRU ROOF IP F DUCTWORK 2 UNISTRUT SUPPORT IATAn r--------- ----- I I I I I I I I I I I I I 1 I I I I I I MOTOR AND BELT COVER STRUCTURAL STEEL BY OTHERS - INLINE EXHAUST FAN MOUNTING DETAIL NO SCALE ^'cl^^""'r,''T SWITCH NAILER COUNTERFLASHING----., PREFABRICATED INSULATED �\ ROOF CURB W/ NAILER BY DIV. 15; SECURE TO ROOF DECK. FLASHING BY OTHERS OUTSIDE AIR T.C. DAMPER _ CORD EXTERNAL ALUM. WIRE POST GLANCED DAMPER FOR DUCT SIZE ROOF MOUNTED FAN INSTALLATION NO SCALE INTAKE HOOD 0 '\—BIRDSCREEN MIN. 18" ABOVE >,.,--ROOF SURFACE BUILT—UP ROOF ROOF DECK PROVIDE ROOF OPENING AS REQUIRED 3 INTAKE AIR HOOD INSTALLATION DETAIL NO SCALE SECOND FLOOR VENTILATION PLAN 1/8" = 1'-0" - xunvU===_= Ogg 125 � 14x -. - -- ECUH-3 A101 A108 A107 ---------- - ----- --- . _ -� --- ECUH-3 ECUH-3 -- ;r ---- _____.- 46 ____ _______ _______ - - -- --- ..----- -------- .: - ------- -- -- ------ -- - FIRST FLOOR VENTILATION PLAN ROOM LEGEND - UNIT A ROOM EXAMPLE MANUFACTURER CORE STYLE OVERALL SIZE L"x W" NO. ROOM NAME AREA CLNG HT A101 CUSTODIAN/STORAGE 213 SF VARIES A102 ELEV. MECH. 51 SF 10'-0" A103 LOBBY 121 SF 10'-0" A104 CONCESSIONS 278 SF 10'-0' A105 WOMENS RESTROOM 431 SF 10'-0" A106 MENS RESTROOM 316 SF 10'-0" A107 MECHANICAL/ELEC. 174 SF EXP. A108 FAMILY RESTROOM 65 SF 10'-0" A109 STORAGE 109 SF 10'-0" AS1 STAIRS 98 SF — ROOM LEGEND - UNIT A ROOM EXAMPLE MANUFACTURER CORE STYLE OVERALL SIZE L"x W" NO. ROOM NAME AREA CLNG HT A201 VARSITY PRESSBOX 409 SF 9'-11" A202 JR VARSITY PRESSBOX 214 SF 9'-11" A203 PASSAGE 226 SF 9'-11" A204 OFFICE 168 SF 9'-11" A205 LOCKER ROOM 614 SF 9'-11" A206 RESTROOM 52 SF 9'-11" A207 STORAGE 35 SF 9'-11" A208 VESTIBULE 77 SF 9'-11" AS1 STAIRS 148 SF 9'-11" 3 1 GENERAL NOTES: 7� 1. COORDINATE FINAL DIFFUSER AND GRILLE LOCATIONS WITH _341W a ARCHITECTURAL REFLECTED CEILING PLANS, A9 DRAWING SERIES. _. -------------- 2. COORDINATE ALL REQUIRED ROOF, WALL, AND FLOOR OPENINGS (BOTH DIMENSIONS AND LOCATIONS) WITH STRUCTURAL STEEL PLANS, STRUCTURAL STEEL CONTRACTOR AND ALL OTHER TRADES. 3. ALL DUCT SIZES SHOWN ARE CLEAR FREE—AREA DIMENSIONS. 1/8" = 1'-0" 4. EACH BRANCH DUCT SHALL BE PROVIDED WITH A VOLUME DAMPER. AN MOU 1 HT F LOUVERS DIFFUSER, REGISTER AND GRILLE SCHEDULE MARK EXAMPLE MANUFACTURER CORE STYLE OVERALL SIZE L"x W" NECK VELOCITY NOISE CRITERIA MATERIAL COLOR FRAME REMARKS MANUFACTURER MODEL NO. VEL. (FPM) I (INCHES) ARRANGEMENT KW STAGES A TITUS 50R '/2"x1/2"x1/2of ALUMINUM CORE 12x12 400 < 10 STEEL BORDER AS SELECTED BY ARCH. LAY—IN CEILING MOUNTED B TITUS 50R '/2"x1/2"x1/2" ALUMINUM CORE 24x12 400 <10 STEEL BORDER AS SELECTED BY ARCH. LAY—IN I TITUS 50R 1�2ofx1/2"x1/2It I ALUMINUM COREC 24x24 400 < 10 STEEL BOR AS SELECTED BY ARCH. LAY—IN (IN.) ELECTRIC HEATER SCHEDULE LOCATION MARK L"xH"xD„ EQUIPMENT ELECTRIC HEATING COIL CFM EAT UNIT ELEC. DATA MANUFACTURER NOTES VEL. (FPM) I (INCHES) ARRANGEMENT KW STAGES MAX. INTAKE AMPS VOLTS PH. AND MODEL N0. 26x36 ECUH-1 45x26x10 CEILING MOUNTED 6.0 2 500/ 60 — 480 3� QMARK CU945 1, 2, 3 REFER TO NOTES SERVICE MANUFACTURER AND 400 NOTES (IN.) RPM ECUH-2 35x26x10 CEILING MOUNTED 4.0 2 250/ 60 — 480 34s QMARK CU935 1, 2, 3 REFER TO NOTES (FPM) 200 ECUH-3 35x26x10 CEILING MOUNTED 2.0 1 250/ 60 — 480 3� QMARK CU935 1, 2, 3 115 10 REFER TO NOTES RESTROOMS GREENHECK MODEL BSQ-120 200 _ EF -2 UPBLAST CENTRIFUGAL 1045 0.5 1065 NOTES: 7.8 BELT 1/4 115 1. PROVIDE A TRIM KIT WITH FIRST FLOOR HEATERS WHICH ARE INSTALLED IN A LAY—IN—CEILING. ON ROOF LOCKER ROOM GREENHECK GB -131 2. PROVIDE EXPOSED CEILING MOUNTED HEATERS FOR SECOND FLOOR INSTALLATION. — VF -1 IN—LINE CENTRIFUGAL 3. PROVIDE INTEGRAL THERMOSTAT WITH EACH HEATER. 0.35 1068 3128 7.5 EXHAUST FAN / VENTILATION FAN SCHEDULE MARK TYPE LOCATION CFM THROAT THROAT E IZES) OVERALL SIZE HEIGHT MOTOR DATA REMARKS NO. VEL. (FPM) I (INCHES) TOTAL MODEL NO. MAX. MAX. INTAKE ON ROOF 1045 600 FAN 26x36 16 GREENHECK FABRAHOOD MARK NO. FAN TYPE CFM S.P. FAN TIP NOISE DRIVE LOCATION SERVICE MANUFACTURER AND CONTROL NOTES (IN.) RPM SPEED LEVEL TYPE HP VOLTS PH MODEL NO. (FPM) (SONES) EF -1 IN—UNE CENTRIFUGAL 1200 0.5 1348 4632 10.5 BELT 1/4 115 10 ROOM A105 RESTROOMS GREENHECK MODEL BSQ-120 0 _ EF -2 UPBLAST CENTRIFUGAL 1045 0.5 1065 3659 7.8 BELT 1/4 115 10 ON ROOF LOCKER ROOM GREENHECK GB -131 S — VF -1 IN—LINE CENTRIFUGAL 350 0.35 1068 3128 7.5 BELT 1/4 115 10 ROOM A109 ELEVATOR EQUIPMENT GREENHECK MODEL BSQ-120 T _ ROOM RELIEF / INTAKE AIR HOOD SCHEDULE MARK TYPE LOCATION CFM THROAT THROAT E IZES) OVERALL SIZE HEIGHT MANUFACTURER AND REMARKS NO. VEL. (FPM) I (INCHES) (IN.) MODEL NO. IH -1 INTAKE ON ROOF 1045 600 16x16 26x36 16 GREENHECK FABRAHOOD 5. COORDINATE EXACT SHAPE, SIZE D NTING HE G 0 AND GRILLES WITH ARCHITECTURAL BUILDING INTERIOR AND EXTERIOR ELEVATIONS. 6. COORDINATE MECHANICAL SYSTEMS INSTALLATION WITH CEILING AND BULKHEAD HEIGHTS INDICATED ON ARCHITECTURAL DRAWINGS. 7. PROVIDE ACCESS DOORS IN HARD CEILINGS AS REQUIRED TO ACCESS CONCEALED HVAC DAMPERS AND EQUIPMENT. PLAN NOTES: O1 2424 EXHAUST AIR LOUVER. O2 1606 UP TO ROOF MOUNTED INTAKE HOOD. O3 EF -1 TO BE CONTROLLED BY MOTION SENSORS LOCATED IN ROOMS A105 AND A106. MOTION SENSORS PROVIDED BY OTHERS. FAN TO RUN FOR 5 MINUTES (ADJUSTABLE) AFTER OCCUPANCY. 40 EF -2 TO BE CONTROLLED BY WALL MOUNTED ON/OFF SWITCH WITH INDICATOR LIGHT. O5 MOTORIZED DAMPER TO OPEN WHEN EXHAUST FAN EF -1 ENERGIZES AND CLOSE WHEN EXHAUST FAN SHUTS DOWN. © MOTORIZED DAMPER TO OPEN WHEN EXHAUST FAN EF -2 ENERGIZES AND CLOSE WHEN EXHAUST FAN SHUTS DOWN. O7 CONNECT 1606 DUCT INTO 24x24 EXHAUST AIR PLENUM BEHIND LOUVER. ® VF -1 CONTROLLED BY REVERSE ACTING THERMOSTAT IN ROOM A102. O9 2424 DOWN TO CEILING MOUNTED GRILLE. 10 16x16 EXHAUST DUCT UP TO ROOF MOUNTED EXHAUST FAN. X Co W i Ja Oa.w Q Z w�a U Q � Da � D w V W =Qa J 2 Utz � LL Cc 0 Q cl) U O-011 lommI O 00 LL� M T CV CHERRY TREE SOFTBALL COMPLEX RENOVATIONS 208032.00.00