HomeMy WebLinkAbout49GENERAL ELECTRICAL SYMBOLS CONDUIT CONCEALED ABOVE CEILING OR IN WALL — — — CONDUIT CONCEALED IN OR BELOW FLOOR — - — CONDUIT EXPOSED ON CEILING, WALL OR CEILING JOIST INDICATES NUMBER OF CONDUCTORS IN CONDUIT TO BE USED AS A GENERAL GUIDE TO SHOW INTENT OF CIRCUITING AND SWITCHING ARRANGEMENT... NOT SHOWN IN ALL CASES... CONTRACTOR SHALL VERIFY AND INSTALL ADDITIONAL CONDUCTOR WHERE REQUIRED 1LB1 1 HOME -RUN, PANELBOARD AND CIRCUIT NUMBER INDICATED GENERAL ELECTRICAL NOTES 1. 2 BY 4 -FOOT FLUORESCENT LUMINAIRES SHALL BE TYPE F-3, 1 BY 4 -FOOT FLUORESCENT LUMINAIRES SHALL BE TYPE F-1, AND 2 BY 2 -FOOT FLUORESCENT LUMINAIRES SHALL BE TYPE F-22, UNLESS OTHERWISE INDICATED. FINAL CONNECTION TO RECESSED LUMINAIRES IS TO BE WITH FLEXIBLE METALLIC CONDUIT. 2. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF LUMINAIRES. COORDINATE LOCATION OF LUMINAIRES, LOUDSPEAKERS, DIFFUSERS, GRILLES, AND OTHER CEILING INSTALLED ELEMENTS WITH THEIR RESPECTIVE INSTALLERS. 3. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND ROOM FINISH SCHEDULE TO DETERMINE PROPER TYPE OF LUMINAIRE TRIM REQUIRED FOR CEILING TYPE PRIOR TO ORDERING LUMINAIRES. PROVIDE LUMINAIRES COMPATIBLE WITH CEILING TYPE. 4. PROVIDE RECESSED LUMINAIRES WITH SEISMIC CLIPS AND SAFETY CHAINS. 5. PROVIDE NO. 10 AWG, MINIMUM, CONDUCTORS FOR EXIT SIGNS AND SECURITY LIGHT CIRCUITS. 6. PROVIDE SEPARATE RACEWAY FOR EMERGENCY SYSTEM WIRING PER NEC ARTICLE 700. 7. GROUND DEVICES, EQUIPMENT, FIXTURES, AND THE LIKE, WITH A PROPERLY SIZED EQUIPMENT GROUNDING CONDUCTOR. MAINTAIN MECHANICAL/ELECTRICAL BONDS OF METALLIC RACEWAY SYSTEM. 8. REFER TO MECHANICAL PLANS FOR LOCATION OF MECHANICAL EQUIPMENT. LOCATE DISCONNECT SWITCHES PER NEC. 9. REFER TO DIVISION 21, 22, & 23 SPECIFICATIONS, MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL ELECTRICAL WORK AND REQUIREMENTS. 10. REFER TO "CONTROL SCHEMATICS" MECHANICAL DRAWINGS FOR ADDITIONAL CONTROL WIRING AND CONTROL CONNECTIONS. 11. UNLESS OTHERWISE NOTED, DEVICE ELEVATIONS REFER TO BOTTOM OF DEVICE. VERIFY OUTLET LOCATIONS WITH OTHER TRADES BEFORE ROUGH -IN. 12. SEPARATE RECEPTACLES BACK-TO-BACK IN WALLS AT LEAST 8 INCHES. 13. PROVIDE "SEAL -OFFS" WHEN CONDUITS PASS THROUGH AREAS OF DIFFERENT AMBIENT TEMPERATURES OR HAZARD CLASSIFICATIONS. 14. LUMINAIRE TYPE IS SHOWN ONLY ONCE, AS "TYP." IN EVERY ROOM. PROVIDE SAME TYPE OF LUMINAIRE THROUGH -OUT SAME ROOM UNLESS OTHERWISE INDICATED. 15. PROVIDE BRANCH CIRCUIT BREAKERS SERVING MULTI -WIRE BRANCH CIRCUITS WITH HANDLE -TIES. 16. REFER TO TECHNOLOGY PLANS FOR COMMUNICATIONS AND SECURITY. 17. DERATE WHEN 4 OR MORE PHASE CONDUCTORS ARE INSTALLED IN SAME CONDUIT. INCREASE CONDUCTOR SIZE AS FOLLOWS: NO. OF CONDUCTORS AMPACITY INCREASE 4 THRU 6 125% 7 THRU 9 (MAX.) 145% AL1 -1,3,5 AUXILIARY SYMBOLS FIRE ALARM: ADDRESSABLE INTERFACE DEVICE QT FIRE ALARM: HEAT DETECTOR Qs FIRE ALARM: PHOTOELECTRIC SMOKE DETECTOR o FIRE ALARM: CONTROL PANEL FAP. I� FIRE ALARM: AUDIBLE AND VISIBLE NOTIFICATION APPLIANCE FIRE ALARM: MANUAL FIRE ALARM BOX, AND AUDIBLE AND VISIBLE NOTIFICATION APPLIANCE 4s FIRE ALARM: VISIBLE NOTIFICATION APPLIANCE Q FIRE ALARM: SMOKE DAMPER ACTUATOR AND DUCT SMOKE DETECTOR FIRE ALARM: MANUAL FIRE ALARM BOX Dr4 FIRE ALARM: FLOW SWITCH CONNECTION Dr4� FIRE ALARM: SUPERVISORY VALVE CONNECTION GROUND CONDUCTOR(S) PHASE CONDUCTOR(S) NEUTRAL CONDUCTOR(S) SWITCH LEG OR GO-BETWEEN ALL CONDUCTORS #12 AWG UNLESS OTHERWISE NOTED -CIRCUIT NO. DESIGNATION PANEL DESIGNATION NOTES: 1. #12 AWG IS MIN. CONDUCTOR SIZE, EXCEPT AS NOTED. POWER SYMBOLS o DISTRIBUTION PANEL ® PANELBOARD �] UTILITY METER I.0 PUSH BUTTON STATION, TYPE INDICATED FM PUSH BUTTON STATION, ON/OFF FD PUSH BUTTON STATION, UP/DOWN/STOP E] PHOTOCELL HAIR DRYER ® HAND DRYER p1 NON-FUSED DISCONNECT pi FUSED DISCONNECT ® MAGNETIC STARTER ®Ms MAGNETIC STARTER, TYPE "MS", UNLESS NOTED OTHERWISE COMBINATION MAGNETIC STARTER WITH DISCONNECT SWITCH, TYPE "CMF -3", CMF -3 UNLESS NOTED OTHERWISE Tc TIME CLOCK SWITCH Q RELAY Q AQUASTAT QQ SOLENOID VALVE Q THERMOSTAT 4 MOTOR H PUSH BUTTON SHUT-OFF o GENERATOR ANNUNCIATOR PANEL GAP. 0 MAGNETIC CONTACTOR UTILITY POLE CIRCUIT BREAKER DISCONNECT ® DUPLEX RECEPTACLE INSTALLED FLUSH IN CEILING 6 COUNTERTOP DOUBLE -DUPLEX RECEPTACLE 0 DOUBLE -DUPLEX RECEPTACLE w COUNTERTOP DUPLEX RECEPTACLE cc DUPLEX RECEPTACLE %, DUPLEX RECEPTACLE WITH CORD AND PLUG SET cc DUPLEX SWITCHED RECEPTACLE ® ' FIRE RATED POKE-THRU FLOOR DUPLEX RECEPTACLE ®F FLUSH MOUNTED FLOOR DUPLEX RECEPTACLE ® �D PEDESTAL MOUNTED DUPLEX RECEPTACLE Fl GROUND FAULT CIRCUIT INTERRUPTER DUPLEX RECEPTACLE HIGH CAPACITY FLOOR BOX i# HORIZONTALLY MOUNTED COUNTERTOP DUPLEX RECEPTACLE HORIZONTALLY MOUNTED DUPLEX RECEPTACLE �G ISOLATED GROUND DUPLEX RECEPTACLE O JUNCTION BOX 057 JUNCTION BOX WITH FLEXIBLE CONNECTION TO EQUIPMENT ® SPECIAL CONNECTION RECEPTACLE d' DUPLEX RECEPTACLE SERVING WATER COOLER OF WEATHER PROOF DUPLEX RECEPTACLE PENDENT CORD/CONNECTOR DEVICE WITH 2 STRAIGHT BLADE TYPE DUPLEX RECEPTACLES, UNLESS NOTED OTHERWISE 9- SIMPLEX RECEPTACLE a TELEPHONE/POWER POLE RECEPTACLE 0? TAMPER RESISTANT DUPLEX RECEPTACLE hAdb l7dMULTIOUTLET ASSEMBLY ,j,.F MANUAL FUSIBLE STARTING LIGHTING SYMBOLS LARGE DOWNLIGHT OR PENDENT Q LARGE DOWNLIGHT OR PENDENT LUMINAIRE WITH EMERGENCY FLUORESCENT POWER UNIT OR EMERGENCY TRANSFER DEVICE AS INDICATED 0 SMALL DOWNLIGHT OR PENDENT LUMINAIRE Q SMALL DOWNLIGHT OR PENDENT LUMINAIRE WITH EMERGENCY FLUORESCENT POWER UNIT OR EMERGENCY TRANSFER DEVICE AS INDICATED F0ORF1fl WALL MOUNTED LUMINAIRE F•® WALL MOUNTED EXIT SIGN ® CEILING MOUNTED EXIT SIGN -0-OARM MOUNTED AREA LUMINAIRE OR Q POLE TOP AREA LUMINAIRE FLUORESCENT LUMINAIRE, APPROXIMATE SIZE INDICATED. ("NL", INDICATES NIGHT LIGHT FIXTURES) 0 FLUORESCENT LUMINAIRE WITH EMERGENCY FLUORESCENT POWER UNIT OR EMERGENCY TRANSFER DEVICE AS INDICATED. E) CEILING MOUNTED OCCUPANCY SENSOR � SWITCH: WALL MOUNTED OCCUPANCY SENSOR K SWITCH: KEYED 4 -WAY SNAP SWITCH: DOUBLE -POLE SNAP � SWITCH: 4 -WAY SNAP �c K SWITCH: KEYED SINGLE POLE, DOUBLE THROW, CENTER -OFF, MOMENTARY CONTACT SNAP _V3�K SWITCH: KEY OPERATED yr SWITCH: LIGHTED HANDLE SWITCH: SINGLE -POLE SNAP V)TP SWITCH: MANUAL STARTING SWITCH WITH THERMAL OVERLOAD PROTECTION AND PILOT LIGHT TYPE "ST -2", UNLESS NOTED OTHERWISE sic SWITCH: SINGLE POLE, DOUBLE THROW, CENTER -OFF, MOMENTARY CONTACT SNAP SWITCH: SNAP WITH PILOT LIGHT A&ST SWITCH: SPRING WOUND TIMER .T SWITCH: 3 -WAY SNAP SWITCH: KEYED 3 -WAY SNAP ■ LIGHTING CONTACTOR ELECTRICAL ABBREVIATIONS ABBREVIATIONS USED ON DRAWINGS IN GENERAL ARE LISTED BELOW. A AMPS AC AIR CONDITIONING ACU AIR CONDITIONING UNIT AFF ABOVE FINISH FLOOR AFG ABOVE FINISH GRADE AHU AIR HANDLER UNIT AWG AMERICAN WIRE GAUGE BRKR BREAKER C CONDUIT CAN CABLE ANTENNA TELEVISION CH CABINET HEATER CKT or CIRC. CIRCUIT CL LIGHTING CONTACTOR CMF COMBINATION MOTOR FUSIBLE STARTER CPT CONTROL POWER TRANSFORMER CPU CENTRAL PROCESSING UNIT Cu COPPER DIA DIAMETER DISTR DISTRIBUTION DWC DRINKING WATER COOLER EF EXHAUST FAN EL EXISTING LOCATION ELEC ELECTRICAL EM EMERGENCY EMT ELECTRICAL METALLIC TUBING EX or EXTG EXISTING EXP EXPLOSION PROOF TYPE DEVICE F FUSE FAA FIRE ALARM ANNUNCIATOR PANEL FAP FIRE ALARM PANEL FCU FAN COIL UNIT FIXT LIGHT FIXTURE FLUOR FLUORESCENT FPB FAN POWERED BOX FS FUSIBLE SWITCH G GROUND GFI GROUND FAULT CIRCUIT INTERRUPTER GRC GALVANIZED RIGID CONDUIT H&V HEATING AND VENTILATING UNIT HID HIGH INTENSITY DISCHARGE HP HORSEPOWER HTP HEAT PUMP J JUNCTION BOX KCM or MCM Kcmil KCM OR MCM KEC KITCHEN EQUIPMENT CONTRACTOR KVA KILOVOLT AMPERE KW KILOWATTS MAN MASTER ANTENNA TV MCC MOTOR CONTROL CENTER MSB MAIN SWITCHBOARD MSC MOTOR STARTER CENTER MTD MOUNTED MZU MULTI -ZONE HVAC UNIT +N INDICATES MOUNTING HEIGHT (N) TO BOTTOM OF DEVICE FROM FINISH FLOOR UNLESS NOTED OTHERWISE NFS NONFUSIBLE SWITCH NIC NOT IN CONTACT NL NIGHT LIGHT NTS NOT TO SCALE O.C. or OC ON CENTER PVC POLYVINYL CHLORIDE PE PNUEMATIC/ELECTRIC PH PROPELLER HEATER PNL PANEL 0 or P PHASE OR POLE RAF RETURN AIR FAN RVS REDUCE VOLTAGE STARTER SW SWITCH TCP TEMPERATURE CONTROL PANEL TPR TRANSPONDER TR TAMPER RESISTANT TV TELEVISION TYP TYPICAL UEF UTILITY EXHAUST FAN UG UNDERGROUND UH UNIT HEATER UNO UNLESS NOTED OTHERWISE UV UNIT VENTILATOR V VOLTS VAV VARIABLE AIR VOLUME VIF VERIFY IN FIELD VC VOLUME CONTROL W WATTS WC WATER COOLER WG WIRE GUARD WP WEATHERPROOF TYPE DEVICE v z c W F— O N y } W 3 O x d z z z a U- m ao o N F— a, oc a O 0 l giffin faiL& ytilfi s COW0 CY 0 1w R cn C4 E U 1�1 M 0 0 N O 00 Go O CD N � N N O N z Lu O 00 Lu F - p O z 0) z O W Ir T r w 1 KEY TO ELECTRICAL CIRCUIT WIRING CHERRY TREE SOFTBALL COMPLEX RENOVATIONS NO SCALE I 1 1 208032.00.00