HomeMy WebLinkAbout49GENERAL ELECTRICAL SYMBOLS
CONDUIT CONCEALED ABOVE CEILING OR IN WALL
— — — CONDUIT CONCEALED IN OR BELOW FLOOR
— - — CONDUIT EXPOSED ON CEILING, WALL OR CEILING JOIST
INDICATES NUMBER OF CONDUCTORS IN CONDUIT TO BE USED AS
A GENERAL GUIDE TO SHOW INTENT OF CIRCUITING AND SWITCHING
ARRANGEMENT... NOT SHOWN IN ALL CASES... CONTRACTOR SHALL
VERIFY AND INSTALL ADDITIONAL CONDUCTOR WHERE REQUIRED
1LB1 1 HOME -RUN, PANELBOARD AND CIRCUIT NUMBER INDICATED
GENERAL ELECTRICAL NOTES
1. 2 BY 4 -FOOT FLUORESCENT LUMINAIRES SHALL BE TYPE F-3, 1 BY 4 -FOOT
FLUORESCENT LUMINAIRES SHALL BE TYPE F-1, AND 2 BY 2 -FOOT
FLUORESCENT LUMINAIRES SHALL BE TYPE F-22, UNLESS OTHERWISE
INDICATED. FINAL CONNECTION TO RECESSED LUMINAIRES IS TO BE WITH
FLEXIBLE METALLIC CONDUIT.
2. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF
LUMINAIRES. COORDINATE LOCATION OF LUMINAIRES, LOUDSPEAKERS,
DIFFUSERS, GRILLES, AND OTHER CEILING INSTALLED ELEMENTS WITH THEIR
RESPECTIVE INSTALLERS.
3. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND ROOM FINISH
SCHEDULE TO DETERMINE PROPER TYPE OF LUMINAIRE TRIM REQUIRED FOR
CEILING TYPE PRIOR TO ORDERING LUMINAIRES. PROVIDE LUMINAIRES
COMPATIBLE WITH CEILING TYPE.
4. PROVIDE RECESSED LUMINAIRES WITH SEISMIC CLIPS AND SAFETY CHAINS.
5. PROVIDE NO. 10 AWG, MINIMUM, CONDUCTORS FOR EXIT SIGNS AND SECURITY
LIGHT CIRCUITS.
6. PROVIDE SEPARATE RACEWAY FOR EMERGENCY SYSTEM WIRING PER NEC
ARTICLE 700.
7. GROUND DEVICES, EQUIPMENT, FIXTURES, AND THE LIKE, WITH A PROPERLY
SIZED EQUIPMENT GROUNDING CONDUCTOR. MAINTAIN MECHANICAL/ELECTRICAL
BONDS OF METALLIC RACEWAY SYSTEM.
8. REFER TO MECHANICAL PLANS FOR LOCATION OF MECHANICAL EQUIPMENT.
LOCATE DISCONNECT SWITCHES PER NEC.
9. REFER TO DIVISION 21, 22, & 23 SPECIFICATIONS, MECHANICAL AND PLUMBING
PLANS FOR ADDITIONAL ELECTRICAL WORK AND REQUIREMENTS.
10. REFER TO "CONTROL SCHEMATICS" MECHANICAL DRAWINGS FOR ADDITIONAL
CONTROL WIRING AND CONTROL CONNECTIONS.
11. UNLESS OTHERWISE NOTED, DEVICE ELEVATIONS REFER TO BOTTOM OF DEVICE.
VERIFY OUTLET LOCATIONS WITH OTHER TRADES BEFORE ROUGH -IN.
12. SEPARATE RECEPTACLES BACK-TO-BACK IN WALLS AT LEAST 8 INCHES.
13. PROVIDE "SEAL -OFFS" WHEN CONDUITS PASS THROUGH AREAS OF DIFFERENT
AMBIENT TEMPERATURES OR HAZARD CLASSIFICATIONS.
14. LUMINAIRE TYPE IS SHOWN ONLY ONCE, AS "TYP." IN EVERY ROOM. PROVIDE
SAME TYPE OF LUMINAIRE THROUGH -OUT SAME ROOM UNLESS OTHERWISE
INDICATED.
15. PROVIDE BRANCH CIRCUIT BREAKERS SERVING MULTI -WIRE BRANCH CIRCUITS
WITH HANDLE -TIES.
16. REFER TO TECHNOLOGY PLANS FOR COMMUNICATIONS AND SECURITY.
17. DERATE WHEN 4 OR MORE PHASE CONDUCTORS ARE INSTALLED IN SAME
CONDUIT. INCREASE CONDUCTOR SIZE AS FOLLOWS:
NO. OF CONDUCTORS AMPACITY INCREASE
4 THRU 6 125%
7 THRU 9 (MAX.) 145%
AL1 -1,3,5
AUXILIARY SYMBOLS
FIRE ALARM: ADDRESSABLE INTERFACE DEVICE
QT FIRE ALARM: HEAT DETECTOR
Qs FIRE ALARM: PHOTOELECTRIC SMOKE DETECTOR
o FIRE ALARM: CONTROL PANEL
FAP.
I� FIRE ALARM: AUDIBLE AND VISIBLE NOTIFICATION APPLIANCE
FIRE ALARM:
MANUAL FIRE ALARM BOX, AND AUDIBLE AND VISIBLE NOTIFICATION APPLIANCE
4s FIRE ALARM: VISIBLE NOTIFICATION APPLIANCE
Q FIRE ALARM: SMOKE DAMPER ACTUATOR AND DUCT SMOKE DETECTOR
FIRE ALARM: MANUAL FIRE ALARM BOX
Dr4 FIRE ALARM: FLOW SWITCH CONNECTION
Dr4� FIRE ALARM: SUPERVISORY VALVE CONNECTION
GROUND CONDUCTOR(S)
PHASE CONDUCTOR(S)
NEUTRAL CONDUCTOR(S)
SWITCH LEG OR GO-BETWEEN
ALL CONDUCTORS #12 AWG
UNLESS OTHERWISE NOTED
-CIRCUIT NO. DESIGNATION
PANEL DESIGNATION
NOTES:
1. #12 AWG IS MIN. CONDUCTOR SIZE, EXCEPT AS NOTED.
POWER SYMBOLS
o DISTRIBUTION PANEL
® PANELBOARD
�] UTILITY METER
I.0 PUSH BUTTON STATION, TYPE INDICATED
FM PUSH BUTTON STATION, ON/OFF
FD PUSH BUTTON STATION, UP/DOWN/STOP
E] PHOTOCELL
HAIR DRYER
® HAND DRYER
p1 NON-FUSED DISCONNECT
pi FUSED DISCONNECT
® MAGNETIC STARTER
®Ms MAGNETIC STARTER, TYPE "MS", UNLESS NOTED OTHERWISE
COMBINATION MAGNETIC STARTER WITH DISCONNECT SWITCH, TYPE "CMF -3",
CMF -3 UNLESS NOTED OTHERWISE
Tc TIME CLOCK SWITCH
Q RELAY
Q AQUASTAT
QQ SOLENOID VALVE
Q THERMOSTAT
4 MOTOR
H PUSH BUTTON SHUT-OFF
o GENERATOR ANNUNCIATOR PANEL
GAP.
0 MAGNETIC CONTACTOR
UTILITY POLE
CIRCUIT BREAKER DISCONNECT
® DUPLEX RECEPTACLE INSTALLED FLUSH IN CEILING
6 COUNTERTOP DOUBLE -DUPLEX RECEPTACLE
0 DOUBLE -DUPLEX RECEPTACLE
w COUNTERTOP DUPLEX RECEPTACLE
cc DUPLEX RECEPTACLE
%, DUPLEX RECEPTACLE WITH CORD AND PLUG SET
cc DUPLEX SWITCHED RECEPTACLE
® ' FIRE RATED POKE-THRU FLOOR DUPLEX RECEPTACLE
®F FLUSH MOUNTED FLOOR DUPLEX RECEPTACLE
® �D PEDESTAL MOUNTED DUPLEX RECEPTACLE
Fl GROUND FAULT CIRCUIT INTERRUPTER DUPLEX RECEPTACLE
HIGH CAPACITY FLOOR BOX
i# HORIZONTALLY MOUNTED COUNTERTOP DUPLEX RECEPTACLE
HORIZONTALLY MOUNTED DUPLEX RECEPTACLE
�G ISOLATED GROUND DUPLEX RECEPTACLE
O JUNCTION BOX
057 JUNCTION BOX WITH FLEXIBLE CONNECTION TO EQUIPMENT
® SPECIAL CONNECTION RECEPTACLE
d' DUPLEX RECEPTACLE SERVING WATER COOLER
OF WEATHER PROOF DUPLEX RECEPTACLE
PENDENT CORD/CONNECTOR DEVICE WITH 2 STRAIGHT BLADE TYPE
DUPLEX RECEPTACLES, UNLESS NOTED OTHERWISE
9- SIMPLEX RECEPTACLE
a TELEPHONE/POWER POLE RECEPTACLE
0? TAMPER RESISTANT DUPLEX RECEPTACLE
hAdb l7dMULTIOUTLET ASSEMBLY
,j,.F MANUAL FUSIBLE STARTING
LIGHTING SYMBOLS
LARGE DOWNLIGHT OR PENDENT
Q LARGE DOWNLIGHT OR PENDENT LUMINAIRE WITH EMERGENCY FLUORESCENT
POWER UNIT OR EMERGENCY TRANSFER DEVICE AS INDICATED
0 SMALL DOWNLIGHT OR PENDENT LUMINAIRE
Q SMALL DOWNLIGHT OR PENDENT LUMINAIRE WITH EMERGENCY FLUORESCENT
POWER UNIT OR EMERGENCY TRANSFER DEVICE AS INDICATED
F0ORF1fl WALL MOUNTED LUMINAIRE
F•® WALL MOUNTED EXIT SIGN
® CEILING MOUNTED EXIT SIGN
-0-OARM MOUNTED AREA LUMINAIRE
OR
Q POLE TOP AREA LUMINAIRE
FLUORESCENT LUMINAIRE, APPROXIMATE SIZE INDICATED.
("NL", INDICATES NIGHT LIGHT FIXTURES)
0 FLUORESCENT LUMINAIRE WITH EMERGENCY FLUORESCENT POWER UNIT OR
EMERGENCY TRANSFER DEVICE AS INDICATED.
E) CEILING MOUNTED OCCUPANCY SENSOR
� SWITCH: WALL MOUNTED OCCUPANCY SENSOR
K SWITCH: KEYED 4 -WAY SNAP
SWITCH: DOUBLE -POLE SNAP
� SWITCH: 4 -WAY SNAP
�c K SWITCH: KEYED SINGLE POLE, DOUBLE THROW, CENTER -OFF,
MOMENTARY CONTACT SNAP
_V3�K SWITCH: KEY OPERATED
yr SWITCH: LIGHTED HANDLE
SWITCH: SINGLE -POLE SNAP
V)TP SWITCH: MANUAL STARTING SWITCH WITH THERMAL OVERLOAD PROTECTION
AND PILOT LIGHT TYPE "ST -2", UNLESS NOTED OTHERWISE
sic SWITCH: SINGLE POLE, DOUBLE THROW, CENTER -OFF, MOMENTARY CONTACT SNAP
SWITCH: SNAP WITH PILOT LIGHT
A&ST SWITCH: SPRING WOUND TIMER
.T SWITCH: 3 -WAY SNAP
SWITCH: KEYED 3 -WAY SNAP
■ LIGHTING CONTACTOR
ELECTRICAL ABBREVIATIONS
ABBREVIATIONS USED ON DRAWINGS IN GENERAL ARE LISTED BELOW.
A
AMPS
AC
AIR CONDITIONING
ACU
AIR CONDITIONING UNIT
AFF
ABOVE FINISH FLOOR
AFG
ABOVE FINISH GRADE
AHU
AIR HANDLER UNIT
AWG
AMERICAN WIRE GAUGE
BRKR
BREAKER
C
CONDUIT
CAN
CABLE ANTENNA TELEVISION
CH
CABINET HEATER
CKT or CIRC.
CIRCUIT
CL
LIGHTING CONTACTOR
CMF
COMBINATION MOTOR FUSIBLE STARTER
CPT
CONTROL POWER TRANSFORMER
CPU
CENTRAL PROCESSING UNIT
Cu
COPPER
DIA
DIAMETER
DISTR
DISTRIBUTION
DWC
DRINKING WATER COOLER
EF
EXHAUST FAN
EL
EXISTING LOCATION
ELEC
ELECTRICAL
EM
EMERGENCY
EMT
ELECTRICAL METALLIC TUBING
EX or EXTG
EXISTING
EXP
EXPLOSION PROOF TYPE DEVICE
F
FUSE
FAA
FIRE ALARM ANNUNCIATOR PANEL
FAP
FIRE ALARM PANEL
FCU
FAN COIL UNIT
FIXT
LIGHT FIXTURE
FLUOR
FLUORESCENT
FPB
FAN POWERED BOX
FS
FUSIBLE SWITCH
G
GROUND
GFI
GROUND FAULT CIRCUIT INTERRUPTER
GRC
GALVANIZED RIGID CONDUIT
H&V
HEATING AND VENTILATING UNIT
HID
HIGH INTENSITY DISCHARGE
HP
HORSEPOWER
HTP
HEAT PUMP
J
JUNCTION BOX
KCM or MCM
Kcmil KCM OR MCM
KEC
KITCHEN EQUIPMENT CONTRACTOR
KVA
KILOVOLT AMPERE
KW
KILOWATTS
MAN
MASTER ANTENNA TV
MCC
MOTOR CONTROL CENTER
MSB
MAIN SWITCHBOARD
MSC
MOTOR STARTER CENTER
MTD
MOUNTED
MZU
MULTI -ZONE HVAC UNIT
+N
INDICATES MOUNTING HEIGHT (N) TO BOTTOM OF DEVICE
FROM FINISH FLOOR UNLESS NOTED OTHERWISE
NFS
NONFUSIBLE SWITCH
NIC
NOT IN CONTACT
NL
NIGHT LIGHT
NTS
NOT TO SCALE
O.C. or OC
ON CENTER
PVC
POLYVINYL CHLORIDE
PE
PNUEMATIC/ELECTRIC
PH
PROPELLER HEATER
PNL
PANEL
0 or P
PHASE OR POLE
RAF
RETURN AIR FAN
RVS
REDUCE VOLTAGE STARTER
SW
SWITCH
TCP
TEMPERATURE CONTROL PANEL
TPR
TRANSPONDER
TR
TAMPER RESISTANT
TV
TELEVISION
TYP
TYPICAL
UEF
UTILITY EXHAUST FAN
UG
UNDERGROUND
UH
UNIT HEATER
UNO
UNLESS NOTED OTHERWISE
UV
UNIT VENTILATOR
V
VOLTS
VAV
VARIABLE AIR VOLUME
VIF
VERIFY IN FIELD
VC
VOLUME CONTROL
W
WATTS
WC
WATER COOLER
WG
WIRE GUARD
WP
WEATHERPROOF TYPE DEVICE
v
z
c
W
F—
O
N
y
}
W
3
O
x
d
z
z
z
a
U-
m
ao
o
N
F—
a,
oc
a
O
0
l giffin faiL& ytilfi
s
COW0
CY 0 1w
R cn C4
E
U
1�1
M
0
0
N
O
00 Go
O CD
N �
N
N
O N
z
Lu
O
00
Lu
F -
p
O
z
0)
z
O
W
Ir
T
r
w
1 KEY TO ELECTRICAL CIRCUIT WIRING CHERRY TREE SOFTBALL COMPLEX RENOVATIONS
NO SCALE I 1 1
208032.00.00