HomeMy WebLinkAbout244.2 C E 0 �w �> ow N W W 2 � OIL CD Cj J p0 Q IPA 2 3 4 SECTION # M001 SHT, # WHERE CONTROL PANEL SERVICE ACCESS SECTION IS DRAWN INSTALL TO ENSURE REQUIRED ELECTRICAL CLEARANCE TERMINAL UNIT HOT WATER PROVIDE DAMPERS AT ALL BRANCHES TO SUPPLY DIFFUSERS. REHEAT COIL 3'-0" MIN. STRAIGHT AT ROUND INTO RECTANGULAR DUCT DUCT SECTION CONNECTIONS PROVIDE SPIN -IN TYPE FITTING I�I� WITH DAMPER. MED. VELOCITY ROUND DUCT, INTERIOR DIM., 00"0 EXTERNALLY INSULATED MED. VELOCITY FLAT OVAL OR ROUND SUPPLY DUCT, INTERIOR DIM. 1ST NUMBER WIDTH, 2ND NUMBER DEPTH 00"/00" OR 00" 0 FD FIRE DAMPER ® � SUPPLY DUCT UP -DOWN PT RIQR CITY T LINRNA� 0 dEL.� DUGE� DE Qo/ f+�E5IINS�JPPI,D�ATE .�ATEOr �TPKE PEQUI h(TYQGIP. T'� 5 AGI��QNN D VE EDUGNRIAI, EQU �IDEAR TP? UP UPCPP d�L TA�AI,EGTR GIC T RETURN OR EXHAUST DUCT UP -DOWN FLEX. DUCT 1'-0" MAX. RECTANGULARPROVIDE SIDE-WALL GRILLE TRANSSITI VARIABLE AIR VOLUME TERMINAL UNIT rz:::� TU -XXX INDICATES ROOM SERVED BY UNIT 45 -LATERAL ,,,- PROVIDE MINIMUM OF TWO ELBOWS BETWEEN TERMINAL UNIT AND DIFFUSER. SUPPLY DIFFUSER S_ SEE SCHEDULE XXX -___CFM (TYP.) PROVIDE FLEX DUCT TO ALL OUTLETS THOUGH XXX NOT SHOWN IN PLAN VIEW (3'-0" MIN. LENGTH) (6'-0" MAX. LENGTH) USE FORMFLEX ELBOW AS MANUFACTURED BY THERMOFLEX TO ENSURE 1.5 RADIUS ELBOWS. REFER TO DETAILS. "-PROVIDE TURNING VANES (SUPPLY DUCT ONLY) IF RADIUSED ELBOW IS NOT POSSIBLE AND MITERED ELBOW IS USED TAKE-OFFI 61LOW VELOCITY RECTANGULAR SUPPLY DUCT. SHEET METAL DIM., 1ST NUMBER WIDTH, 2ND NUMBER DEPTH. EXTERNALLY INSULATED. /,LOW VELOCITY ROUND DUCT EXTERNALLY INSULATED RETURN OR EXHAUST GRILLE SEE SCHEDULE /f m R- E_. 1XXX OR XXX CFM (TYP.) PROVIDE VOLUME DAMPER IN DUCT AT ALL EXH. AND RETURN BRANCHES TO GRILLES LOW VELOCITY RECTANGULAR EXHAUST OR RETURN DUCT. SHEET METAL DIM., 1ST NUMBER WIDTH, 2ND NUMBER DEPTH HVAC DUCT LEGEND SCALE: NONE INS E UND A ED E PEI�ETA�I,PTE� ASI, �E�Tf� ,�IT,,, PQINSU� SSUREET� INS AT GQG VAI I.QGI AL�� wri V PRET 000TTVN I,Qw EXTERN ��� DUE�(TE TYPE SUPP • 0 0 DUGT S ENGTf� TRAIGNT PLC ;, �IA� Q,, 01NN IQN if. -'o 3'' T SE DUG HVAC DUCT LEGEND DETAIL SCALE: NONE HVAC SYMBOLS AND ABBREVIATIOI NOTE: NOT ALL SYMBOLS MAY BE USED. NEW TO EXISTING CONNECTION A.F.F. -j FD PNEUMATIC THERMOSTAT FOR TERMINAL UNITS LINE VOLTAGE THERMOSTAT FOR RADIANT CEILING PANELS EQUIPMENT TO BE REMOVED FIRE DAMPER 3 DN. EX. FD MAX. MIN. PRESS RM. TU TYP. VAV VD CLG. H TG. MANUF LE .,-PHOTO OR ISOMETRIC A VIEW MARK M001 EQUIPED SUPC cc To 'SCApN �L IN CTRIG IN CLC EG �,� U OIC INS SpUPP�( ES REH IN NESUPC EXT. ING PRED�S. DUGT ,TUR O, Egg SUREENGT�) V� PRNIP�� (5'0 IUS AD now ABOVE FINISHED FLOOR DOWN EXISTING FIRE DAMPER MAXIMUM MINIMUM PRESSURE ROOM TERMINAL UNIT TYPICAL VARIABLE AIR VOLUME VOLUME DAMPER COOLING HEATING MANUFACTURER 4 5 7 ROOM AIRFLOW SCHEDULE ROOM NUMBER ROOM NAME FLOOR AREA SF CEILING HEIGHT (FT) PRESSURIZATION (+,-,_) SUPPLY CFM RETURN CFM EXHAUST CFM ACH 200 LOBBY 208 8'-0" - 0 150 0 5.4 200A HALLWAY 117 8'-0" + 175 0 0 11.2 201 CHECK-IN 91 8'-0" = 75 75 0 6.2 202 FAMILY SLEEP RM 339 8'-0" = 420 420 0 9.3 203 PATIENT RESTROOM 83 8'-0" - 90 0 115 10.4 204 FAMILY BREAK RM 150 8'-0" + 555 0 0 27.8 205 FAMILY LOUNGE 222 8'-0" - 410 965 0 32.6 206 ON-CALL SUITE 221 8'-0" + 18a 160 0 6.1 207 ON-CALL RESTROOM 75 8'-0" - 85 0 105 10.5 208A HALLWAY 126 8'-0" + 280 0 0 16.7 208B HALLWAY 706 8'-0" - 470 660 0 7.0 208D HALLWAY 299 8'-0" + 160 0 0 4.0 209 SLEEP ROOM 202 8'-0" = 165 165 0 6.1 210 PATIENT RESTROOM 100 8'-0" - 110 0 135 10.1 211 SLEEP ROOM 208 8'-0" = 345 345 0 12.4 212 NOURISHMENT 222 8'-0" - 280 535 0 18.1 214 STAFF BREAK RM 95 8'-0" + 380 0 0 30.0 215 STAFF RESTROOM 78 8'-0" - 165 0 190 18.3 216 OBSERVATION 317 8'-0" - 520 875 0 20.7 217 READING ROOM 157 8'-0" = 355 355 0 16.9 218 STORAGE 38 8'-0" + 25 0 0 4.9 219 SLEEP ROOM 196 8'-0" = 160 160 0 6.1 220 SLEEP ROOM 204 8'-0" = 165 165 0 6.1 221 SLEEP ROOM 232 8'-0" = 190 190 0 6.1 222 SLEEP ROOM 197 8'-0" = 160 160 0 6.1 223 BED STORAGE 135 8'-0" = 310 310 0 17.2 224 SLEEP ROOM 211 8'-0" = 355 355 0 12.6 225 SLEEP ROOM 220 8'-0" = 440 440 0 15.0 226 PATIENT RESTROOM 83 8'-0" - 90 0 115 10.4 227 PATIENT RESTROOM 88 8'-0" - 95 0 120 10.2 228 SOILED UTILITY 87 8'-0" - 110 0 135 11.6 229 CLEAN SUPPLY 66 8'-0" + 65 0 0 7.4 230 VACUUM ROOM 150 8'-0" - 870 870 0 43.5 231 MED GAS 27 8'-0" - 0 0 96 26.7 SCHEDULE OF FAN POWERED TERMINAL UNITS SYMBOL MANUF. MODEL SIZE INLET SIZE CLG. MIN./H TG. CFM DESIGN CFM MAXIMUM BOX CFM AIR VALVE PRESSURE DROP (IN. WG) ELECTRIC REHEAT COIL KW - STAGES L.A.T . (.F) FAN CHARACTERISTICS ACOUSTICS - RADIATED FAN AND VALVE (NC) REMARKS CFM ESP HP VAV-202 TRANE VSCF 08 8 0 420 900 0.053 S-2 70.00 420 0.25 0.125 30 ALL NOTES APPLY VAV-204 TRANE VSEF 10 10 290 965 1400 0.159 - 2.5 2 72.62 965 0.25 0.500 35 ALL NOTES APPLY VAV-206 TRANE VSCF 06 6 0 265 500 0.049 - 70.00 265 0.25 0.125 30 ALL NOTES APPLY VAV-208B TRANE VSEF 12 12 365 1215 2000 0.024 3.0 - 2 72.24 1215 0.25 0.500 38 ALL NOTES APPLY VAV-209 TRANE VSCF 10 10 0 725 1400 0.179 - 70.00 725 0.25 0.333 33 ALL NOTES APPLY VAV-210 TRANE VSCF 08 8 0 450 900 0.062 - 70.00 450 0.25 0.125 31 ALL NOTES APPLY VAV-211 TRANE VSEF 06 6 105 345 500 0.086 1.5 - 1 78.08 345 0.25 0.125 29 ALL NOTES APPLY VAV-216 TRANE VSEF 10 10 320 1065 1400 0.071 2.5 - 2 71.86 1065 0.25 0.500 36 ALL NOTES APPLY VAV-217 TRANE VSEF 06 6 110 355 500 0.091 1.0 - 1 73.16 355 0.25 0.125 30 ALL NOTES APPLY VAV-220 TRANE VSCF 06 6 0 325 500 0.076 - 70.00 325 0.25 0.125 30 ALL NOTES APPLY VAV-222 TRANE VSCF 06 6 0 350 500 0.089 - 70.00 350 0.25 0.125 30 ALL NOTES APPLY VAV-225 TRANE VSEF 10 10 280 930 1400 0.144 2.5 - 2 73.94 930 0.25 0.500 35 ALL NOTES APPLY VAV-230 TRANE VSEF 10 10 295 870 1400 0.195 2.5 - 2 72.81 870 0.25 1 0.333 34 ALL NOTES APPLY NOTES: 1. THE #'S AFTER THE "VAV-" CORRESPOND TO THE ROOM NUMBER IN WHICH THE THERMOSTAT IS LOCATED. 2. UNITS SHALL BE PRESSURE INDEPENDENT. 3. FAN MOTORS SHALL BE 277/60/1. AMP DRAW IS MAXIMUM ACCEPTABLE. 4. ELECTRIC HEATERS SHALL BE 460/60/3. AMP DRAW IS MAXIMUM ACCEPTABLE. 5. AIR VALVE PRESSURE DROP SHALL NOT EXCEED 0.2". 6. PROVIDE 24V CONTROL TRANSFORMER FOR EACH VAV TERMINAL UNIT. 7. PROVIDE FACTORY MOUNTED DDC CONTROLLER FOR EACH VAV TERMINAL UNIT. CONTRACTOR SHALL PROVIDE TITUS TERMINAL UNITS IN LIEU OF THE TRANE UNITS SPECIFIED. SCHEDULE OF GRILLES & DIFFUSERS SCHEDULE OF EXHAUST FANS PANEL SIZE SYMBOL AREA SERVED MANUF. TYPE SIZE WATTS FRPM MOUNTING CFM STATIC TITUS ELECTRICAL FAN REMARKS 6"0 98 3 0.044 <10 4 LAY -IN ALL NOTES APPLY S-2 PRESSURE PAS CHARACTERISTICS MOUNTING 8"0 EF -3 MED GAS ROOM GREENHECK CSP 8110 80 950 S-3 96 0.5 24x24 115/1 IN-LINE ALL NOTES APPLY NOTES: 0.036 14 4 LAY -IN 1. FURNISH WITH BACKDRAFT DAMPER, DISCONNECT. TITUS PAS 24x24 SCHEDULE OF GRILLES & DIFFUSERS SYMBOL MANUFACTURER MODEL PANEL SIZE CORE TYPE INLET DIMENSION NOMINAL CFM THROW ®100 FPM PRESSURE DROP(IN.) SOUND N.C. THROWS MOUNTING REMARKS S-1 TITUS PAS 24x24 PERFORATED 6"0 98 3 0.044 <10 4 LAY -IN ALL NOTES APPLY S-2 TITUS PAS 24x24 PERFORATED 8"0 175 4 0.049 16 4 LAY -IN ALL NOTES APPLY S-3 TITUS PAS 24x24 PERFORATED 10"o 218 4 0.036 14 4 LAY -IN ALL NOTES APPLY S-4 TITUS PAS 24x24 PERFORATED 12"0 236 6 0.032 <10 4 LAY -IN ALL NOTES APPLY S-5 TITUS PAS 24x24 PERFORATED 14"0 1 321 1 6 0.034 1 12 4 LAY -IN ALL NOTES APPLY SCHEDULES R-1 TITUS PAR 24x24 PERFORATED 22x22 1008 N/A 0.03 13 N/A LAY -IN ALL NOTES APPLY E-1 TITUS PAR 24x24 PERFORATED 22x22 1008 N/A 0.03 13N /A LAY -IN ALL NOTES APPLY E-2 TITUS 350R 8x8 LOUVER 6x6 57 N/A 0.018 <10 N/A SIDEWALL ALL NOTES APPLY NOTES: 1. COLOR SHALL BE AS DIRECTED BY ARCHITECT. 2. ALL GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH VOLUME DAMPERS. j WA rx L u SCHEDULE OF ELECTRIC RADIANT CEILING PANELS SYMBOL MANUFACTURER MODEL SIZE ELECTRICAL CHARACTERISTICS WATTS MOUNTING REMARKS CP -1 317 595.1000 main 317 572.1236 fax MARLEY/QMARK CP 12x24 277/1 155 LAY -IN ALL NOTES APPLY CP -2 CONSULTING ENGINEERS MARLEY/QMARK CP 12x36 277/1 235 LAY -IN ALL NOTES APPLY CP -3 Z MARLEY/QMARK CP 12x48 277/1 315 LAY -IN ALL NOTES APPLY NOTES: d M 0 cri z "- U Qz 1. FACE SHALL BE SILKSCREENED TO MATCH ACOUSTICAL CEILING TILES. W W ::F 2. PROVIDE WITH LINE VOLTAGE THERMOSTAT. W � a. 0 z 3. PROVIDE WITH FUSED DISCONNECT. cli � W j WA rx L u STUDIO THREE DESIGN architecture - interior design wwwAtudio3design,net 317 595.1000 main 317 572.1236 fax 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 CONSULTANT BIAGI, CHANCE, CUMMINS, LONDON, TITZER, INC. CONSULTING ENGINEERS INDIANA - KENTUCKY - M1550URI - NEW )ER5EY 1060 Capitol Avenue Suite E240 Inciianapolis, IN 46204 www. BCC LT. co m PHONE: 317-968-0239 FAX: 317-968-0235 v Z W d 0 v -' O cli � M � d M 0 cri z "- U Qz �.....a . W - J �._.. W W W ::F W � a. 0 z 0 cli � W z PROJECT NO. 10977 DATE REVISIONS CERTIFICATION S TeRde, Z No. 19441. -o", STATE OF �o • •�2 0'� •% ND FssIAN �oN ..• �� W z-8-11 SHEET DESCRIPTION HVAC LEGEND AND SCHEDULES SHEET NUMBER M001 THIS DRAWING IS THE PROPERTY OF STUDIO 3 DESIGN, INC., ALL RIGHTS RESERVED.