HomeMy WebLinkAbout26M 19 Le N E F 0 �w 0 o N w w ~ V) of E �z r J O V J WD¢ 1 2 3 w 5 0 7 r T 2 3 GENERAL NOTES: A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE AREA TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS. VERIFY SIZE, LOCATION, AND USAGE OF EXISTING UTILITIES. B. CUT, PATCH & REPAIR ALL OPENINGS IN WALLS, FLOORS, CEILINGS, ETC. WHERE REQUIRED BY THE REMOVAL OF EQUIPMENT, DUCTWORK, AND ACCESSORIES. PATCHING SHALL MATCH EXISTING CONSTRUCTION & FINISHES. COORDINATE ALL PATCHING AND FINISHES WITH ARCHITECT. PATCHING OF FIRE WALLS SHALL MEET THE RATING AND SHALL BE INSTALLED PER ARCHITECTURAL SPECIFICATION. C. PROPER CONNECTIONS, MATERIALS, AND SIZES OF DUCTWORK SHALL BE MAINTAINED TO ENSURE EQUIPMENT IS MADE FULLY OPERATIONAL. D. CONTRACTOR SHALL PROVIDE MANUFACTURER'S RECOMMENDED ACCESS TO ALL TERMINAL UNITS AND VALVES. ACCESS SHALL BE REMOVABLE CEILING TILES OR 24"x24" CEILING ACCESS PANELS. MOUNT TERMINAL UNIT AT HEIGHT THAT IS EASILY ACCESSIBLE WITH A LADDER. COORDINATE LOCATION OF MECHANICAL EQUIPMENT WITH OTHER TRADES TO AVOID CONFLICT. E. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR LOCATION OF GRILLES AND DIFFUSERS. F. FOR ALL WALLS THAT ARE EXTENDED TO STRUCTURE PROVIDE SLEEVES FOR DUCTWORK PENETRATING WALLS PER SPECS. G. DRAWING IS DIAGRAMMATIC, PROVIDE ADDITIONAL OFFSETS, TRANSITIONS, ETC. AS REQUIRED TO AVOID INTERFERENCES ENCOUNTERED. H. PROVIDE SEISMIC PROTECTION OF THE MECHANICAL DUCTWORK AND EQUIPMENT TO MEET THE REQUIREMENTS OF THE INDIANA BUILDING CODE. 4 5 I. RELOCATION OF EXISTING PIPE AND EQUIPMENT HANGERS REQUIRED FOR INSTALLATION OF NEW WORK SHALL BE CONSIDERED PART OF THIS CONTRACT. J. THE REMOVAL DRAWINGS SHALL SERVE TO AID THE CONTRACTOR IN THE EVALUATION OF THE EXTENT OF REMOVALS, BUT SHALL NOT BE HELD TO BE ALL INCLUSIVE K. OWNER SHALL BE GIVEN FIRST CHOICE ON ALL EQUIPMENT BEING REMOVED THAT WILL NOT BE RELOCATED. CONTRACTOR SHALL REVIEW THE EXISTING EQUIPMENT WITH OWNER. EQUIPMENT BEING REMOVED OR RELOCATED SHALL BE REMOVED IN A MANNER THAT REUSE IS POSSIBLE AND STORED AS DIRECTED BY OWNER. ALL OTHER EQUIPMENT SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED & DISPOSED OF FROM THE SITE BY THE CONTRACTOR. L. IF EQUIPMENT TO REMAIN MUST BE REMOVED DUE TO REMOVAL OR CONSTRUCTION, THE EQUIPMENT SHALL BE RELOCATED IN A MANNER THAT IS ACCEPTABLE BY THE OWNER/ARCHITECT/ENGINEER AT NO ADDITIONAL COST. M. REMOVAL OF EXISTING EQUIPMENT SHALL BE MADE SO THAT SERVICE TO OTHER AREAS UTILIZED BY THE OWNER ARE NOT INTERRUPTED WITHOUT CONSENT FROM OWNER. PROVIDE TEMPORARY VALVES AND TEMPORARY SERVICES REQUIRED DURING REMOVALS AND CONSTRUCTION. N. REMOVE COMPLETELY ALL EXISTING HVAC EQUIPMENT, ALL ASSOCIATED PIPING, CONTROLS, AND SUPPORTS BEING MADE OBSOLETE BY THIS CONSTRUCTION. REMOVAL OF HVAC DUCTWORK, PIPING AND PNEUMATIC CONTROL TUBING SHALL BE MADE BACK TO MAINS AND CAPPED. I 0. CONTRACTOR SHALL BE RESPONSIBLE TO KEEP ALL PHASES OF CONSTRUCTION AREA UNDER A NEGATIVE MODE AND SHALL BE CERTIFIED. PROVIDE A DIGITAL PRESSURE DIFFERENTIAL MEASUREMENT WITH INDICATION TO 0.01 INCHES OF PRESSURE DIFFERENTIAL OUTSIDE THE CONSTRUCTION SITE THAT MEASURES THE PRESSURE WITHIN THE CONSTRUCTION SITE. GAUGE SHALL BE READ AND SIGNED BY THE CONTRACTOR INDICATING NEGATIVE PRESSURE IN THE CONSTRUCTION AREA. WHEN THE BUILDING AIR DISTRIBUTION SYSTEM IS USED TO MAINTAIN NEGATIVE MODE, THE CONTRACTOR SHALL PROVIDE TEMPORARY FILTER MEDIA ON ALL RETURN AND EXHAUST OPENINGS IN THE CONSTRUCTION AREA. THE FILTER MEDIA SHALL BE REPLACED WHEN DIRTY OR WHEN DIRECTED BY THE ENGINEER. P. ANY WORK REQUIRING UTILITY SHUT DOWNS SHALL BE DONE DURING OFF HOURS AND COORDINATED WITH THE OWNER PRIOR TO STARTING WORK. Q. REPAIR/REPLACE TORN INSULATION FOR UTILITIES SERVING THE AREA. 7 KEY PLAN SCALE: NONE 12110 5' 10' 15' III I I I I I I I SCALE: 1/8"=V-0" FP C 0 19 F STUDIO THREE DESI_G N a€chiteure inter' design www.studio3design,net' 317 595.1000 main 317 572.1236 fax 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 CONSULTANT BIAG1, CHANCE, CUMMINS, LONDON, TITZER, INC. CONSULTING ENGINEERS INDIANA - KENTUCKY - M155OURI - NEW JERSEY 1060 Capitol Avenue Suite E240 Indianapolis, IN 46204 www. BCCLT.com PHONE: 317-968-0239 FAX: 317-968-0235 • v z LLJ CZ QO C) O � � N O �o Z U Q z �—LLJc_/ W LLJ < _j w CZ. O z O L-, to r - W z P RO) ECT N O . 10977 DATE 2-8-11 REVISIONS CERTIFICATION 100000980 �;•6 ER •sem! i No. 19447. STATE OF ; Or .� Fss�oN ... *age �� W 2 -8 -II SHEET D ESC R! PTI O N THIRD FLOOR HVAC PLAN SHEET NUMBER M200 THIS DRAWING IS THE PROPERTY OF STUDIO 3 DESIGN, INC., ALL RIGHTS RESERVED.