GENERAL NOTES:
A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING
THE AREA TO BECOME FAMILIAR WITH THE EXISTING
CONDITIONS. VERIFY SIZE, LOCATION, AND USAGE OF
EXISTING UTILITIES.
B. CUT, PATCH & REPAIR ALL OPENINGS IN WALLS, FLOORS,
CEILINGS, ETC. WHERE REQUIRED BY THE REMOVAL OF
EQUIPMENT, DUCTWORK, AND ACCESSORIES. PATCHING
SHALL MATCH EXISTING CONSTRUCTION & FINISHES.
COORDINATE ALL PATCHING AND FINISHES WITH ARCHITECT.
PATCHING OF FIRE WALLS SHALL MEET THE RATING AND
SHALL BE INSTALLED PER ARCHITECTURAL SPECIFICATION.
C. PROPER CONNECTIONS, MATERIALS, AND SIZES
OF DUCTWORK SHALL BE MAINTAINED TO
ENSURE EQUIPMENT IS MADE FULLY OPERATIONAL.
D. CONTRACTOR SHALL PROVIDE MANUFACTURER'S
RECOMMENDED ACCESS TO ALL TERMINAL UNITS
AND VALVES. ACCESS SHALL BE REMOVABLE
CEILING TILES OR 24"x24" CEILING ACCESS PANELS.
MOUNT TERMINAL UNIT AT HEIGHT THAT IS EASILY
ACCESSIBLE WITH A LADDER. COORDINATE LOCATION
OF MECHANICAL EQUIPMENT WITH OTHER TRADES
TO AVOID CONFLICT.
E. REFER TO ARCHITECTURAL REFLECTED CEILING
PLAN FOR LOCATION OF GRILLES AND DIFFUSERS.
F. FOR ALL WALLS THAT ARE EXTENDED TO STRUCTURE
PROVIDE SLEEVES FOR DUCTWORK PENETRATING WALLS
PER SPECS.
G. DRAWING IS DIAGRAMMATIC, PROVIDE ADDITIONAL
OFFSETS, TRANSITIONS, ETC. AS REQUIRED TO
AVOID INTERFERENCES ENCOUNTERED.
H. PROVIDE SEISMIC PROTECTION OF THE MECHANICAL
DUCTWORK AND EQUIPMENT TO MEET THE REQUIREMENTS
OF THE INDIANA BUILDING CODE.
4
5
I. RELOCATION OF EXISTING PIPE AND EQUIPMENT
HANGERS REQUIRED FOR INSTALLATION OF NEW WORK
SHALL BE CONSIDERED PART OF THIS CONTRACT.
J. THE REMOVAL DRAWINGS SHALL SERVE TO AID THE
CONTRACTOR IN THE EVALUATION OF THE EXTENT OF
REMOVALS, BUT SHALL NOT BE HELD TO BE ALL INCLUSIVE
K. OWNER SHALL BE GIVEN FIRST CHOICE ON ALL EQUIPMENT
BEING REMOVED THAT WILL NOT BE RELOCATED.
CONTRACTOR SHALL REVIEW THE EXISTING EQUIPMENT WITH
OWNER. EQUIPMENT BEING REMOVED OR RELOCATED SHALL
BE REMOVED IN A MANNER THAT REUSE IS POSSIBLE AND
STORED AS DIRECTED BY OWNER. ALL OTHER EQUIPMENT
SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND
SHALL BE REMOVED & DISPOSED OF FROM THE SITE BY
THE CONTRACTOR.
L. IF EQUIPMENT TO REMAIN MUST BE REMOVED DUE TO
REMOVAL OR CONSTRUCTION, THE EQUIPMENT SHALL
BE RELOCATED IN A MANNER THAT IS ACCEPTABLE BY THE
OWNER/ARCHITECT/ENGINEER AT NO ADDITIONAL COST.
M. REMOVAL OF EXISTING EQUIPMENT SHALL BE MADE
SO THAT SERVICE TO OTHER AREAS UTILIZED BY
THE OWNER ARE NOT INTERRUPTED WITHOUT CONSENT
FROM OWNER. PROVIDE TEMPORARY VALVES AND
TEMPORARY SERVICES REQUIRED DURING REMOVALS
AND CONSTRUCTION.
N. REMOVE COMPLETELY ALL EXISTING HVAC EQUIPMENT,
ALL ASSOCIATED PIPING, CONTROLS, AND SUPPORTS
BEING MADE OBSOLETE BY THIS CONSTRUCTION. REMOVAL
OF HVAC DUCTWORK, PIPING AND PNEUMATIC CONTROL
TUBING SHALL BE MADE BACK TO MAINS AND CAPPED.
I
0. CONTRACTOR SHALL BE RESPONSIBLE TO KEEP ALL
PHASES OF CONSTRUCTION AREA UNDER A NEGATIVE
MODE AND SHALL BE CERTIFIED. PROVIDE A DIGITAL
PRESSURE DIFFERENTIAL MEASUREMENT WITH INDICATION
TO 0.01 INCHES OF PRESSURE DIFFERENTIAL OUTSIDE
THE CONSTRUCTION SITE THAT MEASURES THE
PRESSURE WITHIN THE CONSTRUCTION SITE. GAUGE
SHALL BE READ AND SIGNED BY THE CONTRACTOR
INDICATING NEGATIVE PRESSURE IN THE CONSTRUCTION
AREA. WHEN THE BUILDING AIR DISTRIBUTION SYSTEM
IS USED TO MAINTAIN NEGATIVE MODE, THE CONTRACTOR
SHALL PROVIDE TEMPORARY FILTER MEDIA ON ALL RETURN
AND EXHAUST OPENINGS IN THE CONSTRUCTION AREA.
THE FILTER MEDIA SHALL BE REPLACED WHEN DIRTY OR
WHEN DIRECTED BY THE ENGINEER.
P. ANY WORK REQUIRING UTILITY SHUT DOWNS SHALL
BE DONE DURING OFF HOURS AND COORDINATED
WITH THE OWNER PRIOR TO STARTING WORK.
Q. REPAIR/REPLACE TORN INSULATION FOR UTILITIES
SERVING THE AREA.
7
KEY PLAN
SCALE: NONE
12110 5' 10' 15'
III I I I I I I I
SCALE: 1/8"=V-0"
FP
C
0
19
F
STUDIO
THREE
DESI_G N
a€chiteure inter'
design
www.studio3design,net'
317 595.1000 main 317 572.1236 fax
8604 Allisonville Road, Suite 330 Indianapolis, IN 46250
CONSULTANT
BIAG1, CHANCE, CUMMINS,
LONDON, TITZER, INC.
CONSULTING ENGINEERS
INDIANA - KENTUCKY - M155OURI - NEW JERSEY
1060 Capitol Avenue Suite E240
Indianapolis, IN 46204
www. BCCLT.com
PHONE: 317-968-0239 FAX: 317-968-0235
•
v
z
LLJ CZ
QO
C)
O
� � N
O
�o
Z
U Q z
�—LLJc_/ W
LLJ
< _j
w
CZ. O
z
O
L-,
to r -
W
z
P RO) ECT N O .
10977
DATE
2-8-11
REVISIONS
CERTIFICATION
100000980
�;•6 ER •sem!
i No. 19447.
STATE OF ; Or
.�
Fss�oN ... *age
��
W
2 -8 -II
SHEET D ESC R! PTI O N
THIRD FLOOR
HVAC
PLAN
SHEET NUMBER
M200
THIS DRAWING IS THE PROPERTY
OF STUDIO 3 DESIGN, INC.,
ALL RIGHTS RESERVED.