Loading...
HomeMy WebLinkAbout31 w I� C 9 E F I I- L_ 1 1 L_. JI 1 1 L. 1 1 1 LJ \��o 1/8 1 /_0 NORTH 2 2 3 4 5 6 CODE SUMMARY: APPLICABLE CODES FOR TENANT SUITE: 2008 INDIANA BUILDING CODE (2006 INTERNATIONAL BUILDING CODE) 2004 INDIANA ENERGY CONSERVATION CODE (1992 MODEL ENERGY CODE) 2008 INDIANA FIRE CODE (2006 INTERNATIONAL FIRE CODE) 1999 INDIANA PLUMBING CODE (1997 UPC) 2009 INDIANA ELECTRICAL CODE (2008 NEPA 70) 2008 INDIANA MECHANICAL CODE (2006 INTERNATIONAL MECHANICAL CODE) OCCUPANCY: B OCCUPANCY, OFFICE BUILDING (SEC. 302.1) CONSTRUCTION TYPE: TYPE 2B (BUILDING SHELL) ALLOWABLE AREA: BASIC ALLOWABLE 23,000 SQ. FT. PER FLOOR. AREA INCREASE: BASED ON SPRINKLER & FRONTAGE = 86,250 PER FLOOR. MAX FLOOR SIZE = 26,572 S.F. OCCUPANT LOAD: OFFICE 100 SQ. FT. PER OCCUPANT GROSS. (26,572 S.F.) / 100 S.F. = 266 OCC. LOAD FOR FLOOR HEIGHT: ACTUAL HEIGHT: 6 STORIES, +/— 80 FT. SQUARE FOOTAGE: 6,585 S.F. REMODELED TENANT SPACE (UPA SLEEP LAB) 26,572 S.F. TOTAL FLOOR 159,432 S.F. TOTAL BUILDING WIDTH OF EXITS: EXIT DOOR WIDTH PROVIDED AT THE RATE OF 0.15 INCHES PER OCCUPANT. (SEC. 1003.2.3) • 2" AT STAIRWAYS = 53.2" • .15" X 266 = 39.9" REQUIRED • 68" PROVIDED 3 4 7 S Um w w SLEEP N. ROOM 203 S.F. \N/A�C' HR �11 &REM oL EXITACCESS TRAVEL DISTANCE: 300 FEET PERMITTED, BASE UPON SPRINKLERED BUILDING. (SEC. 1004.2.4) CLEAR AISLE CLEARANCE: 5'-0 W CORRIDORS FOR BUSINESS OCCUPANCY IN PATIENT AREAS, 44" IN STAFF ONLY AREAS. DEAD EN D CORRI DORS: 50'-0" ALLOWED BASED ON FULLY SPRINKLERED BUILDING COMMON PATH OF TRAVEL: NOT TO EXCEED 100' IN SPRINKLERED, B OCCUPANCY. FIRE SUPPRESSION SYSTEM: PROJECT AREA FULLY SPRINKLERED. BUILDING IS FULLY PROTECTED BY AUTOMATIC SPRINKLER SYSTEM. FIRE RESISTIVE CORRIDORS: A & B OCCUPANCY RATING NOT REQUIRED IF FULLY SPRINKLERED. EXIT PASSAGEWAYS SHALL NOT BE LESS THAN 44". SMOKE BARRIER: 3 SMOKE COMPARTMENTS EACH UNDER 10,000 S.F. PLUMBING COUNT: RESTROOMS — PUBLIC EXISTING TO REMAIN (4) UNISEX PATIENT RESTROOMS IN SUITE. (2) UNISEX STAFF RESTROOMS IN SUITE. 5 STORAGE ROOMS: UNDER 100 SQ. FT. NOT REQUIRED TO BE RATED. FILE STORAGE: MINIMUM CLEARANCE FROM TOP OF STORAGE TO BOTTOM OF SPRINKLER HEAD IS 18" CLEAR. G CODE PLAN KEY NOTES: (J EXISTING RATED ENCLOSURE, VERTICAL SHAFTS / STAIRS / ELEVATORS RATING TO BE MAINTAINED. PATCH ANY OPENINGS CAUSED BY CONSTRUCTION TO MEET / MAINTAIN RATED ASSEMBLY. O1 HOUR WALL ASSEMBLY & 45 MIN. RATED DOOR. ORATED EXIT. O4 SUITE EXITS. O5 FIRE EXTINGUISHERS LOCATED MAX 75' FROM ANY POINT ON FLOOR. © NOT USED OEXIT CORRIDOR PRESENT HATCHED WALL AREA REPRESENT NEW WALL CONSTRUCTION EXISTING RATED SHAFT ENCLOSURE 7 L— r— L '_ A, 1 10 I� E F STUDIO THREE DESIGN architecture M interior design www.studio3design.net 317 595.1000 main sig 572.1236 fax 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 CONSULTANT BIAGI, CHANCE, CUMMINS, LONDON, TITZER, INC. CONSULTING ENGINEERS INDIANA - KENTUCKY - MISSOURI - NEW JERSEY 1060 Capitol Avenue Suite E240 Indianapolis, IN 46204 www. BCC LT. co m PHONE: 317-968-0239 FAX: 317-968-0235 s v Z _ t ^� V 1 W 0 _ O O V 1 � � N M �o t� z U Qz — J � W �, jJ W Q W a. O z 0 In W _ Z PRO) ECT NO. 10012.03 DATE 2-8-11 REVISIONS CERTIFICATION `�����►►a►u►uumuun�i,,��� °��O-Ny W ' co 10\,�G�STERF�GF No. *' 910110 STATE OF `` .�vss SHEET DESCRIPTION CO[ )E E INFORMATION/ LIFE SAFETY PLAN SHEET NUMBER A002 THIS DRAWING IS THE PROPERTY OF STUDIO 3 DESIGN, INC., ALL RIGHTS RESERVED. Q I m LU w Z Z O O I w w Y ■ Y on 'Ln EXITACCESS TRAVEL DISTANCE: 300 FEET PERMITTED, BASE UPON SPRINKLERED BUILDING. (SEC. 1004.2.4) CLEAR AISLE CLEARANCE: 5'-0 W CORRIDORS FOR BUSINESS OCCUPANCY IN PATIENT AREAS, 44" IN STAFF ONLY AREAS. DEAD EN D CORRI DORS: 50'-0" ALLOWED BASED ON FULLY SPRINKLERED BUILDING COMMON PATH OF TRAVEL: NOT TO EXCEED 100' IN SPRINKLERED, B OCCUPANCY. FIRE SUPPRESSION SYSTEM: PROJECT AREA FULLY SPRINKLERED. BUILDING IS FULLY PROTECTED BY AUTOMATIC SPRINKLER SYSTEM. FIRE RESISTIVE CORRIDORS: A & B OCCUPANCY RATING NOT REQUIRED IF FULLY SPRINKLERED. EXIT PASSAGEWAYS SHALL NOT BE LESS THAN 44". SMOKE BARRIER: 3 SMOKE COMPARTMENTS EACH UNDER 10,000 S.F. PLUMBING COUNT: RESTROOMS — PUBLIC EXISTING TO REMAIN (4) UNISEX PATIENT RESTROOMS IN SUITE. (2) UNISEX STAFF RESTROOMS IN SUITE. 5 STORAGE ROOMS: UNDER 100 SQ. FT. NOT REQUIRED TO BE RATED. FILE STORAGE: MINIMUM CLEARANCE FROM TOP OF STORAGE TO BOTTOM OF SPRINKLER HEAD IS 18" CLEAR. G CODE PLAN KEY NOTES: (J EXISTING RATED ENCLOSURE, VERTICAL SHAFTS / STAIRS / ELEVATORS RATING TO BE MAINTAINED. PATCH ANY OPENINGS CAUSED BY CONSTRUCTION TO MEET / MAINTAIN RATED ASSEMBLY. O1 HOUR WALL ASSEMBLY & 45 MIN. RATED DOOR. ORATED EXIT. O4 SUITE EXITS. O5 FIRE EXTINGUISHERS LOCATED MAX 75' FROM ANY POINT ON FLOOR. © NOT USED OEXIT CORRIDOR PRESENT HATCHED WALL AREA REPRESENT NEW WALL CONSTRUCTION EXISTING RATED SHAFT ENCLOSURE 7 L— r— L '_ A, 1 10 I� E F STUDIO THREE DESIGN architecture M interior design www.studio3design.net 317 595.1000 main sig 572.1236 fax 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 CONSULTANT BIAGI, CHANCE, CUMMINS, LONDON, TITZER, INC. CONSULTING ENGINEERS INDIANA - KENTUCKY - MISSOURI - NEW JERSEY 1060 Capitol Avenue Suite E240 Indianapolis, IN 46204 www. BCC LT. co m PHONE: 317-968-0239 FAX: 317-968-0235 s v Z _ t ^� V 1 W 0 _ O O V 1 � � N M �o t� z U Qz — J � W �, jJ W Q W a. O z 0 In W _ Z PRO) ECT NO. 10012.03 DATE 2-8-11 REVISIONS CERTIFICATION `�����►►a►u►uumuun�i,,��� °��O-Ny W ' co 10\,�G�STERF�GF No. *' 910110 STATE OF `` .�vss SHEET DESCRIPTION CO[ )E E INFORMATION/ LIFE SAFETY PLAN SHEET NUMBER A002 THIS DRAWING IS THE PROPERTY OF STUDIO 3 DESIGN, INC., ALL RIGHTS RESERVED.