Loading...
HomeMy WebLinkAbout34n AO C C E F 0 �w o N N W V) E4 �_ 0-0 Ci O V J O Q 1 2 3 4 5 6 7 S E 2 3 4 5 J 7 i A C C E F STUDIO THREE DESIGN archtec#ure interior design www.studio3design.net 817 595.1000 main 317 572.1236 fax 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 CONSULTANT BIAGI, CHANCE, CUMMINS, LONDON, TITZER, INC. CONSULTING ENGINEERS INDIANA - KENTUCKY - MISSOURI - NEW JERSEY 1060 Capitol Avenue Suite E240 Indianapolis, IN 46204 www. BCC LT. co m PHONE: 317-968-0239 FAX: 317-968-0235 v Z tri W 0 LL v O tr> � ll� M 0 tr> z �- �J Q z �.- w � w W W � <��� W 0 z 0 ci Ir - 0v W Z PRO)ECT NO. 10977 DATE 2-5-11 REVISIONS CERTIFICATION \0 J•yO yam; Q�G Fa 0 off No. 19447: -o , STATE OF ; � .�� ����5• ND 1 AN ' e** S/4NAL �� WWmw�)Ijoz-os-n SH EET DESCRIPTION PLUMBING DETAILS SHEET NUMBER THIS DRAWING IS THE PROPERTY OF STUDIO 3 DESIGN, INC., ALL RIGHTS RESERVED. GALVANIZED ALL—THREAD FINISHED APPEARANCE CONTINUOUS ONE PIECE 01 1/2" MIN. FIRE STOPPING 1/2" MIN. SLEEVE OFNGERRODSRIOSDNOTO PERM TTED 50 TO 55 PSIG SLEEVE I PIPE INSULATION SOURCE SHUTOFF VALVE PROVIDE TURNDOWN INSULATION =====_===__==__- INSULATION =_____________________ PIPE INSULATION W/BUGSCREEN ON -- ---- ------ PIPE--- __---------------- PIPE TO OUSIDE OF BUILDING EXTERIOR OF BUILDING PRESSURE RELIEF VALVE LINE PRESSURE _- - _ __ ------ - DO NOT CRUSH PIPING INSULATION GALVANIZED ALL -THREAD REGULATOR -tea ________________ ----- --- WALL WALL PRESSURE CHANGEOVER REGULATOR ACTUATING SWITCH PRESSURE /—REGULATOR INTERIOR RATED WALL INTERIOR NON RATED WALL PIPE SLEEVE DETAIL PIPE SLEEVE DETAIL SCALE: NONE SCALE: NONE PIPE CHECK VALVE PIPE PIPE PIPE FIRE STOPPING TYPICAL 10 GAUGE INSULATION INSULATION SECURE PIPE RING GALVANIZED SHEET HIGH PRESSURE HEADER HIGH PRESSURE HEADER FIRE STOPPING TO FLOOR METAL SADDLE SHUTOFF VALVE SLEEVE PIPE RING CHECK VALVE FIRE STOPPING SILICON INSULATION UNISTRUT CHANNEL INSULATION 1" MIN. ___ ___ 1" MIN. CYLINDER VALVE FLOOR - __ FLOOR TYPICAL PIPING PRESSURE RELIEF =_=_=_ ______ +`:'; `'.:.',`.. ____ ____ LENGTH AS REQUIRED BY DEVICE ; ' ' QUANTITY AND SIZE OF PIPES GALVANIZED DOUBLE NUT WITH SINGLE WASHER. CORE DRILL TYPICAL ON BOTH SIDES SLEEVE OF STRUT NOTES: CYLINDERS NO. 1 BANK CYLINDERS NO. 2 BANK 1. HANGER ROD, STRUT, NUTS, WASHER FLOORS PIPE SLEEVE DETAIL FLOORS PIPE SLEEVE DETAIL AND PIPE STRAPS SHALL BE OF OXYGEN MANIFOLD SYSTEM ZINC COATED GALVANIZED MATERIALS SCALE: NONE TRAPEZE PIPE HANGER DETAIL NOTES: SCALE: NONE 4 1. INSTALL FIRE STOP PER MANUFACTURERS RECOMMENDATION. VACUUM EXHAUST LOCATION SHALL CONFORM TO GALVANIZED ALL -THREAD CONTINUOUS ONE PIECE NFPA 99 SECTION 5.1.3.6.7. HANGER ROD. COUPLING TURNDOWN W/BUGSCREEN OF RODS IS NOT PERMITTED FLASHING COLLAR APPROVED BY MAIN LINE ROOF MFGR.� 2'-0" ROOF VACUUM SWITCH MAIN VACUUM GAUGE lo MV�i 21/2" PIPING INSULATION — — — — — — — — — — — — — — — — — — — DO NOT CRUSH 1" WATER STOP AND ANCHOR COLLAR SLEEVE MECHANICAL MECHANICAL SEAL EAL DISCHARGE FLEX HOSE I I PIPE PIPE (SHALL BE SHIPPED i i SOURCE VALVE LOOSE WITH EQUIPMENT) TYPICAL 10 GAUGE GALVANIZED SHEET METAL SADDLE EQUIPMENT SET PER SCHEDULE CORE DRILL fAND SPECS. ALL OTHER PIPING AND DEVICES SHOWN SHALL BE WALL WALL DISCHARGE EXHAUST I I PROVIDED BY CONTRACTOR. :: .' SILENCER (SHALL BE( I UNISTRUT CHANNEL SHIPPED LOOSE WITH EQUIPMENT) DRIP LEG-/ I I MANUAL f DRAIN VALVE EXTERIOR WALL EXTERIOR WALL TYPICAL PIPING �+ " PIPE SLEEVE DETAIL PIPE SLEEVE DETAIL LENGTH AS REQUIRED BY — _ — — _ — — — — — — — — SCALE: NONE SCALE: NONE QUANTITY AND SIZE OF PIPES GALVANIZED DOUBLE FLOOR NUT TH HOUSEKEEPING PAD FLOOR DRAIN->( TYPICAIL ONINGLE BOTH SIIDESR VIBRATION ISOLATION/ OF STRUT NOTES: SEISMIC RESTRAINTS 1. HANGER ROD, STRUT, NUTS, WASHER AND PIPE STRAPS SHALL BE OF MEDICAL- VACUUM PUMP (MVP1) ZINC COATED GALVANIZED MATERIALS SCALE: NONE TRAPEZE PIPE HANGER DETAIL SCALE: NONE 82 AIR INTAKE LOCATION SHALL CONFORM TO GALVANIZED ALL -THREAD NFPA 99 SECTION 5.1.3.5.13. CONTINUOUS ONE PIECE TURNDOWN W/BUGSCREEN HANGER ROD. COUPLING OF RODS IS NOT PERMITTED FLASHING COLLAR APPROVED BY ROOF MFGR.� 12'-o,, ROOF GALVANIZED STRUT MOUNTED IPS PIPE STRAP TAPE IS NOT PERMITTED 1/s" O.D.x12" LG. HIGH -LOW PRESSURE SWITCH AS A MEANS OF INSULATION BETWEEN PIPING AND CLAMPING NOMINAL FLEXIBLE SUPPLY RISER DEVICE 2' 1 u P ,,MAIN PRESSURE GAUGE GALVANIZED IPS FELT LINED +" OR RUBBER PIPE ISOLATOR MA BETWEEN PIPE STRAP AND PIPE INSULATION 1 SOURCE VALVE T INSULATION SHALL BE MITERED AND TAPED AT ALL CHANGES _ _ _ _ _ _ — — — _ — — IN DIRECTION. I INSULATION SHALL i I/2" COPPER BE EAT REND DJOINT CHICAGO FAUCET TAPED I PROVIDE DIELECTRIC BARRIER MODEL 1005 BETWEEN FITTING AND BLOCKING „ EQUIPMENT SET PER SCHEDULE ,,,,,-EQUIPMENT AND SPECS.„OTHER PI SERVICE STOP 1 MAX. / FIREPROOF BLOCKING DEVICESALL SHOWN SHALLI BEUNISTRUT I I PROVIDED BY CONTRACTOR. CHANNEL LOOSE KEY BUTTON I I N 18-8 TYPICAL PIPING STAINLESS STEEL SCREW STAIN' Z LENGTH AS REQUIRED BY GALVANIZED DOUBLE QUANTITY AND SIZE OF PIPES I I I L I AUTOMATIC VIBRATION ISOLATION/a” I I DRAIN SEISMIC RESTRAINTS � NUT WITH SINGLE WASHER. TYPICAL ON BOTH SIDES OF STRUT NOTES: NPT FEMALE THREAD INLET �I TEE HANDLE I Y+" 1. HANGER ROD, STRUT, NUTS, WASHER HANDLES SHALL BE CHROME PLATED AND PIPE STRAPS SHALL BE OF GIVEN TO OWNER UPON ESCUTCHEON 1/z"Cx-%"F 90' DROP ELL FLOOR ZINC COATED GALVANIZED MATERIALS INSTALLATION AND MATERIALS SHALL COMPLETION OF PROJECT 3$" NPT CHROME PLATED NIPPLE HOUSEKEEPING PAD2. FLOOR DRAIN COMPLY WITH FEDERAL, STATE AND LOCAL CODE REQUIREMENTS INCLUDING N.F.P.A. GUIDELINES MEDICAL OIL—LESS AIR COMPRESSOR (MAC1) TYPICAL SERVICE STOP INSTALLATION TRAPEZE MEDICAL GAS PIPE HANGER DETAIL SCALE: NONE 9 SCALE: NONE SCALE: NONE 3 E 2 3 4 5 J 7 i A C C E F STUDIO THREE DESIGN archtec#ure interior design www.studio3design.net 817 595.1000 main 317 572.1236 fax 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 CONSULTANT BIAGI, CHANCE, CUMMINS, LONDON, TITZER, INC. CONSULTING ENGINEERS INDIANA - KENTUCKY - MISSOURI - NEW JERSEY 1060 Capitol Avenue Suite E240 Indianapolis, IN 46204 www. BCC LT. co m PHONE: 317-968-0239 FAX: 317-968-0235 v Z tri W 0 LL v O tr> � ll� M 0 tr> z �- �J Q z �.- w � w W W � <��� W 0 z 0 ci Ir - 0v W Z PRO)ECT NO. 10977 DATE 2-5-11 REVISIONS CERTIFICATION \0 J•yO yam; Q�G Fa 0 off No. 19447: -o , STATE OF ; � .�� ����5• ND 1 AN ' e** S/4NAL �� WWmw�)Ijoz-os-n SH EET DESCRIPTION PLUMBING DETAILS SHEET NUMBER THIS DRAWING IS THE PROPERTY OF STUDIO 3 DESIGN, INC., ALL RIGHTS RESERVED.