Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
36
G C 0 E F 0 w o� N W W 2 Of ~ 2 N O V U� Ci J WOQ 1 2 M 4 w A ELECTRICAL LEGEND LIGHTING POWER ABBREVIATIONS DEVICE DESCRIPTION DEVICE DESCRIPTION DEVICE DESCRIPTION CEILING OUTLET AND FLUORESCENT LIGHTING FIXTURE AS SCHEDULED. WALL OUTLET WITH 2OA, 125V DUPLEX RECEPTACLE. MOUNT 18" A.F.F. TO BOTTOM, 1,2,3 NUMBER AT OUTLET INDICATES CIRCUIT ARRANGEMENT. UNLESS NOTED OTHERWISE. SUBSCRIPT: GFI = GROUND FAULT CURRENT INTERRUPTER. CEILING OUTLET AND FLUORESCENT LIGHTING FIXTURE AS SCHEDULED. PROVIDED WITH S = SURGE GUARD PROTECTANT. ST = SAFETY TYPE. "AC» SYMBOL INDICATES MOUNT DEVICE 44" ABOVE FINISH FLOOR TO BOTTOM WHEN EMERGENCY BATTERY PACK. SHOWN ON POWER OR SYSTEMS PLANS. WALL OUTLET WITH 2OA, 125V FUTURE EMERGENCY DUPLEX RECEPTACLE. MOUNT 18" SYMBOL INDICATES RECEPTACLE IS DEDICATED FOR UNDER COUNTER REFRIGERATOR CEILING OUTLET AND FLUORESCENT LIGHTING FIXTURE AS SCHEDULED. A.F.F. TO BOTTOM, UNLESS NOTED OTHERWISE.DEVICES SHALL BE GRAY WITH GRAY "UCR" WHEN SHOW ON POWER PLANS. EM SUBSCRIPT "EM" INDICATES FIXTURE PROVIDED WITH EMERGENCY BATTERY PACK. COVER PLATES. SUBSCRIPT: GFI = GROUND FAULT CURRENT INTERRUPTER. S = SURGE GUARD PROTECTANT. ST = SAFETY TYPE. SYMBOL INDICATES RECEPTACLE IS DEDICATED FOR REFRIGERATOR WHEN SHOWN ON O CEILING OUTLET AND COMPACT FLUORESCENT,IN CANDESCENT OR LED LIGHTING FIXTURE AS WALL OUTLET WITH 2OA, 125V DOUBLE DUPLEX (QUADRAPLEX) RECEPTACLE. MOUNT "REF" POWER PLANS. SCHEDULED. 18" A.F.F. TO BOTTOM, UNLESS NOTED OTHERWISE. SUBSCRIPT: GFI = GROUND FAULT Q WALL OUTLET AND FLUORESCENT OR INCANDESCENT LIGHTING FIXTURE AS SCHEDULED. CURRENT INTERRUPTER. S = SURGE GUARD PROTECTANT. ST = SAFETY TYPE. "M W» SYMBOL INDICATES RECEPTACLE IS DEDICATED FOR MICROWAVE WHEN SHOWN ON POWER PLANS. WALL OUTLET AND FLUORESCENT LIGHTING FIXTURE AS SCHEDULED. WALL OUTLET WITH 2OA, 125V FUTURE EMERGENCY DOUBLE DUPLEX (QUADRAPLEX) SYMBOL INDICATES RECEPTACLE IS DEDICATED FOR COFFEE MAKER WHEN SHOWN RECEPTACLE. MOUNT 18" A.F.F. TO BOTTOM, UNLESS NOTED OTHERWISE. DEVICES "CM" ON POWER PLANS. t®� EXIT LIGHT, CEILING MOUNT. LINE OR ARROW INDICATES ORIENTATION OF FACE. SHALL BE GRAY WITH GRAY COVER PLATES. SUBSCRIPT: GFI = GROUND FAULT SHADE REPRESENTS FACE AREA. CURRENT INTERRUPTER. S = SURGE GUARD PROTECTANT. ST = SAFETY TYPE. SYMBOL INDICATES RECEPTACLE OR DATA OUTLET IS DEDICATED FOR TELEVISION EXIT LIGHT, WALL MOUNT. LINE OR ARROW INDICATES ORIENTATION OF FACE. WALL OUTLET WITH 2OA, 125V SIMPLEX RECEPTACLE. MOUNT RECEPTACLE 18" A.F.F. "TV" WHEN SHOWN ON POWER OR SYSTEMS PLANS. VERIFY MOUNTING HEIGHT WITH SHADE REPRESENTS FACE AREA. TO BOTTOM, UNLESS NOTED OTHERWISE. SUBSCRIPT: GFI = GROUND FAULT CURRENT ARCHITECTURAL ELEVATIONS BEFORE ROUGH -IN. INTERRUPTER. S = SURGE GUARD PROTECTANT. ST = SAFETY TYPE. CAPITAL O FIXTURE. LETTER INDICATES FIXTURE TYPE WHEN SHOWN ON LIGHTING PLANS ADJACENT TO O 115V LINE VOLTAGE THERMOSTAT FOR RADIANT CEILING PANEL CONTROL. THERMOSTAT ONE LINE AND WIRING DIAGRAMS FURNISHED BY M.C. INSTALLATED BY E.C. PROVIDE OUTLET BOX IN WALL 54" A.F.F. "NL" SYMBOL INDICATES NIGHT LIGHTING CIRCUIT WHEN SHOWN ON LIGHTING PLANS ADJACENT TO CENTER. TO FIXTURE. ® SURFACE METAL RACEWAY WITH RECEPTACLES AS NOTED. a, ,c LOWER CASE LETTERS AT OUTLETS INDICATE SWITCHING ARRANGEMENT. O JUNCTION BOX. IyTn TRANSFORMER. S SINGLE POLE 20A SWITCH. MOUNT 44" A.F.F. TO BOTTOM, UNLESS NOTED OTHERWISE. CIRCUIT BREAKER. -�- ROUGH -IN AND FINAL CONNECTION. \o- SUBSCRIPT: 3 = THREEWAY. 4 = FOURWAY. D =DIMMER SWITCH. T = TIMER M = o MAINTAINED CONTACT ON-OFF SWITCH. MOMENTARY. DIMMER SHALL BE 1000W RATED UNLESS NOTED OTHERWISE. WORKING CLEARANCE MS CEILING OUTLET AND PASSIVE INFRARED/ULTRASONIC MOTION SENSOR. SUBSCRIPT-----�� -�� NORMALLY CLOSED PUSHBUTTON. INDICATES TYPE. I SURFACE MOUNTED 208Y/120V PANELBOARD. MUSHROOM HEAD OPERATOR PUSHBUTTON. "MSI" INDICATES MOTION SENSOR SIMILAR TO WATTSTOPPER DW -100 DUAL TECHNOLOGY LINE WORKING CLEARANCE VOLTAGE WALL SWITCH SENSOR PROGRAMMABLE TO AUTO ON OR MANUAL ON. PROGRAM -° a- NORMALLY OPEN PUSHBUTTON. SWITCHES TO MANUAL ON WITH 30 MINUTE ON TIME. ADJUST SENSITIVITY AS REQUIRED. SURFACE MOUNTED 480Y/277V PANELBOARD. REPROGRAM SETTINGS AS REQUESTED BY OWNER. I -z- NORMALLY OPEN (N.O.) PUSHBUTTON SWITCH. WORKING CLEARANCE o - NORMALLY CLOSED (N.C.) PUSHBUTTON SWITCH. -n-�¢ "MS2" INDICATES MOTION SENSOR SIMILAR TO WATTSTOPPER DT -355 DUAL TECHNOLOGY LINE -----� VOLTAGE CEILING MOUNTED OCCUPANCY SENSOR. �`.`\y RECESSED 208Y/120V PANELBOARD. �- NORMALLY OPEN CONTACT. WORKING CLEAR;ZFRECESSED POINT OF CONNECTION TO GROUND POTENTIAL. TELECOMMUNICATIONS �----,480Y/277V PANELBOARD. N_ NORMALLY CLOSED CONTACT. WORKING CLEARANCE INDICATING LIGHT. R = RED, G = GREEN, B = BLUE, A = AMBER. OUTLET BOX WITH SINGLE VOICE JACK AND DEVICE PLATE. PROVIDE 1" CONDUIT FROM w OUTLET BOX TO CABLE TRAY SYSTEM IN CORRIDOR. PROVIDE ONE VOICE CABLE FROM DISTRIBUTION PANELBOARD. OVERLOAD ELEMENT. JACK IN OUTLET BOX TO COMMUNICATION SYSTEM IN TELECOMMUNICATIONS ROOM 107 AND TERMINATE PER OWNERS REQUIREMENTS. MOUNT 18 A.F.F. TO BOTTOM, UNLESS NOTED FUSE. OTHERWISE. SUBSCRIPT: W = OUTLET MOUNTED 48" A.F.F. TO BOTTOM. OUTLET BOX WITH ONE DATA JACK AND DEVICE PLATE. PROVIDE 1" CONDUIT FROM OUTLET TELEVISION SYSTEM FUSE. y BOX TO CABLE TRAY SYSTEM IN CORRIDOR. PROVIDE ONE DATA CABLE FROM EACH JACK_ SOLIDLY GROUNDED WYE CONNECTION. IN OUTLET BOX TO COMMUNICATION SYSTEM IN TELECOMMUNICATIONS ROOM 180 AND WALL OUTLET BOX WITH BLANK COVER PLATE AND Y4"C WITH PULL STRING TO TERMINATE PER OWNER'S REQUIREMENTS. MOUNT 18" A.F.F. TO BOTTOM, UNLESS NOTED ACCESSIBLE CEILING CAVITY FOR FUTURE TELEVISION JACK INSTALLATION. VERIFY Y WYE CONNECTION. OTHERWISE. SUBSCRIPT: C = OUTLET MOUNTED FLUSH IN CEILING. MOUNTING HEIGHT WITH ARCHITECT BEFORE ROUGH -IN. DELTA CONNECTION. OUTLET BOX WITH TWO VOICE AND TWO DATA JACKS AND DEVICE PLATE. PROVIDE TELEVISION SIGNAL DISTRIBUTION SYSTEM SPLITTER. NUMBER ADJACENT TO SYMBOL 1" CONDUIT FROM OUTLET BOX TO CABLE TRAY SYSTEM IN CORRIDOR. PROVIDE ONE VOICE Q8 INDICATES NUMBER OF WAYS. CABLE FROM EACH VOICE JACK AND ONE DATA UTP CABLE FROM EACH DATA JACK IN OUTLET BOX TO COMMUNICATION SYSTEM IN TELECOMMUNICATIONS ROOM 180 AND RACEWAY TERMINATE PER OWNERS REQUIREMENTS. MOUNT 18 A.F.F. TO BOTTOM, UNLESS NOTED OTHERWISE. SUBSCRIPT: iv, 3D =ONE VOICE AND THREE DATA JACKS. ��_ HCFAC CABLE. NOTE: TELECOMMUNICATIONS SYSTEM RACK, NETWORK SWITCHES AND PATCH PANELS PROVIDED MOTOR AND MOTOR CONTROL / BY OWNER UNDER SEPARATE CONTRACT UNLESS SPECIFICALLY NOTED OR SHOWN IN ___ �:�� CIRCUIT CONCEALED BENEATH FLOOR OR IN GROUND. CONTRACT DOCUMENTS. E.C. SHALL PROVIDE BACKBOXES, RACEWAYS AND ONE STATION MANUAL STARTER. SUBSCRIPT; TX = THERMAL O.L. (X DENOTES NUMBER OF POLES). ��\\ CONDUCTOR CABLE FROM EACH JACK IN TELECOMMUNICATION SYSTEM OUTLET TO DATA zp, TPX = THERMAL O.L. AND - PILOT LIGHT (X DENOTES NUMBER OF POLES). OVERLOADS EXPOSED CONDUIT. ROOM 180 AND TERMINATE PER OWNER'S REQUIREMENTS. E.C. TO PROVIDE WIRING BLOCKS SHALL MATCH MOTOR. 1HP = ONE HORSEPOWER RATED. / TV TELEVISION SIGNAL CABLE. AS REQUIRED. COORDINATE WORK WITH OWNER I.S. DEPT. FUSIBLE DISCONNECT SWITCH. MOUNT 4'-6" A.F.F. TO CENTER, UNLESS NOTED / F FIRE ALARM CABLE OR CONDUIT. FIRE ALARM SYSTEM OTHERWISE. NP NON -FUSIBLE DISCONNECT SWITCH. MOUNT 4'-6" A.F.F. TO CENTER, UNLESS NOTED z", S_ SOUND MASKING SYSTEM CABLE OR CONDUIT. N PHASE FIRE ALARM SYSTEM MANUAL PULL STATION. MOUNT AT 48" A.F.F. TO BOTTOM, OTHERWISE. UNLESS NOTED OTHERWISE. CONDUCTORSCOMBINATION MAGNETIC MOTOR CONTROLLER TO SUIT MOTOR. MOTOR 4'-6" A.F.F. TO NEUTRAL�� CIRCUIT CONCEALED IN CEILING OR WALL. CROSSBARS INDICATE N CENTER, UNLESS NOTED OTHERWISE. _� NUMBER OF CONDUCTORS REQUIRED. CONDUIT NOT SIZED IS 4'4„ , / FIRE ALARM SYSTEM VISUAL UNIT. WALL MOUNT AT 80” A.F.F. TO BOTTOM, OR 6" GROUND CONDUCTORS NOT SIZED ARE NO. 12. M BELOW CEILING TO TOP, WHICHEVER IS LOWER. MOTOR. 3L4A-1,3,5 HOMERUN TO PANELBOARD INDICATED. NUMBER OF ARROWHEADS FIRE ALARM SYSTEM AUDIO/VISUAL UNIT. MOUNT AT 80" A.F.F. TO BOTTOM, OR 6" INDICATES NUMBER OF CIRCUITS. NUMBER INDICATES CIRCUIT BELOW CEILING TO TOP, WHICHEVER IS LOWER. NUMBERS. PREFIX INDICATES PANEL NUMBER. PA SPRINKLER SYSTEM MONITORED PRESSURE ALARM. SPECIALTY SYSTEMS FS SPRINKLER SYSTEM MONITORED FLOW SWITCH. OUTLET IN CEILING & WHITE NOISE BACKGROUND SPEAKER/ EMITTER. F SUBSCRIPT "X" INDICATES SYSTEM AMP IDENTIFICATION/ CIRCUIT. TS SPRINKLER SYSTEM MONITORED TAMPER SWITCH. WALL MOUNTED AMPLIFIER/ CONTROL MODULE FOR WHITE NOISE BACKGROUND WPMX SYSTEM. SUBSCRIPT "X" INDICATES SYSTEM AMP/ CIRCUIT ID. PS SPRINKLER SYSTEM MONITORED PRESSURE SWITCH. NOTE: WHITE NOISE BACKGROUND SYSTEM SHALL BE PROVIDED WITH AMPLIFIERS, CONTROL © FIRE ALARM SYSTEM ADDRESSABLE CONTROL/MONITOR MODULE. MODULES, SKEAKERS/ EMITTERS, PLENUM CABLING AND BACKBOXES/ RACEWAYS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. E.0 SHALL SUBCONTRACT -AW- FIRE ALARM SYSTEM END OF LINE DEVICE. VENDOR/ MANUFACTURER WITH MINIMUM 2 YEARS EXPERIENCE IN INSTALLING AND MAINTAINING SIMILAR SYSTEMS. E.C. SHALL PROVIDE 1 YEAR MINIMUM WARRANTY ON ALL EQUIPMENT, PARTS, CABLING, AND INSTALLATION. SYSTEM SHALL BE STEELCASE CONFIDANTE SYSTEM OR APPROVED SIMILAR. E.C. SHALL PROVIDE SHOP DRAWINGS AND FLOOR PLAN INDICATING ALL COMPONENTS, CABLING AND WIRING DIAGRAMS FOR REVIEW/ APPROVAL. Iii .! Vol 5 u GENERAL ELECTRICAL NOTES: A. THE REMOVAL PLAN DRAWING SHALL SERVE TO AID THE CONTRACTOR IN HIS EVALUATION OF THE EXTENT OF REMOVALS, BUT SHALL NOT BE HELD TO BE ALL INCLUSIVE. B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE BUILDING AND SITE TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS, VERIFY SIZE, LOCATION, AND USAGE OF UTILITIES AND EQUIPMENT PRIOR TO REMOVAL. C. FOR FURTHER INFORMATION WITH REGARD TO THE EXTENT OF REMOVALS, SEE NEW CONSTRUCTION PLANS AND ARCHITECTURAL PLANS WHICH ILLUSTRATE THE NEW CONSTRUCTION. D. PATCH ALL OPENINGS IN WALLS, FLOORS, AND CEILINGS WHERE REMOVAL OF EQUIPMENT OR DEVICES CREATES SUCH OPENINGS. PATCH OPENINGS TO MATCH EXISTING. E. IF PORTIONS OF CIRCUITS SERVING EQUIPMENT TO REMAIN MUST BE RELOCATED OR REMOVED DUE TO OTHER REMOVAL OR DUE TO INTERFERENCE WITH NEW EQUIPMENT INSTALLATION, THE CIRCUITS SHALL BE MODIFIED IN SUCH A MANNER WHICH WILL ENSURE THE PROPER OPERATION OF THE EQUIPMENT AFTER CONSTRUCTION IS COMPLETE, USE THE SAME TYPE OF CONDUCTOR AND SAME CONDUIT SIZE AS EXISTING TO MAKE ALL REQUIRED MODIFICATIONS. F. IF WALLS, CEILINGS, FLOORS, OR EQUIPMENT ARE REMOVED, OR OTHER REMOVAL OCCURS, WHICH EXPOSES CIRCUITS TO REMAIN, THE CIRCUITS SHALL BE RELOCATED OR MODIFIED IN SUCH A MANNER WHICH SHALL ENSURE THE CONTINUED OPERATION OF THE CIRCUIT. EXISTING CONDUITS EXPOSED DURING REMOVALS WHICH REMAIN TO SERVE EQUIPMENT, SHALL BE RESUPPORTED IN ACCORDANCE WITH THE REQUIREMENTS FOR RACEWAY INSTALLATION IN THE SPECIFICATIONS. G. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REMOVALS REQUIRED FOR THE INSTALLATION OF NEW WORK, WHETHER OR NOT IT IS SPECIFICALLY INDICATED OR NOTED IN THESE DOCUMENTS. H. ALL EQUIPMENT INDICATED AS CROSS HATCHED, OR NOTED, SHALL BE DISCONNECTED AND REMOVED. I. ALL CONDUIT RUNS TO REMOVED EQUIPMENT OR DEVICES SHALL BE COMPLETELY REMOVED BACK TO SOURCE INCLUDING ALL HANGERS, BEAM CLAMPS, MISCELLANEOUS SUPPORTS, AND WIRING, UNLESS WIRING IS REQUIRED TO SERVE EXISTING EQUIPMENT TO REMAIN. J. ALL WIRING DEVICES TO BE REMOVED SHALL BE REMOVED COMPLETELY INCLUDING OUTLET BOX. K. ALL DEVICES, FIXTURES, EQUIPMENT, AND MATERIAL DETERMINED BY THE OWNER TO BE SALVAGEABLE SHALL REMAIN THE PROPERTY OF THE OWNER AND STORED AT THE LOCATION ON THE PREMISES DESIGNATED BY THE OWNER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISPOSAL OF ALL OTHER ELECTRICAL EQUIPMENT WHICH IS DISCONNECTED AND REMOVED DURING DEMOLITION, UNLESS NOTED OTHERWISE. L. REMOVE ALL ABANDONED ELECTRICAL EQUIPMENT, WIRING & CONDUIT WITHIN PROJECT AREA. M. PROVIDE ALL TEMPORARY EGRESS EXIT LIGHTING FIXTURES AS REQUIRED DURING CONSTRUCTION. N. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING & REPLACING ACOUSTICAL LAY -IN CEILING FOR ROUTING OF FEEDERS AND COMMUNICATION CABLING OUTSIDE THE PROJECT AREA, UNLESS SPECIFICALLY NOTED OTHERWISE OR SHOWN ON ARCHITECTURAL DRAWINGS. ALL DAMAGED TILE SHALL BE REPLACED WITH NEW TILE TO MATCH EXISTING. 0. COORDINATE CONDUIT ROUTING WITH MECHANICAL CONTRACTOR TO AVOID CONFLICTS WITH EQUIPMENT AND EQUIPMENT CLEARANCE. P. SEAL AROUND ALL NEW AND EXISTING WALL PENETRATIONS WITH FIRE STOPPING. Q. FINAL CONNECTION TO ALL CEILING MOUNTED DEVICES SHALL BE MADE WITH FLEX CONDUIT. R. FIRE ALARM SYSTEM CABLING SHALL BE PLENUM RATED OR INSTALLED WITHIN CONDUIT. CABLES SHALL BE IN CONDUIT WHEN INSTALLED WITHIN WALLS OR INACCESSIBLE CEILING CAVITIES. S. COORDINATE LIGHTING FIXTURE LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLAN. T. ALL LOW VOLTAGE CABLING INSTALLED LOOSE WITHIN CEILING CAVITIES SHALL BE PLENUM RATED. 7 F 90 19, STUDIO THREE DESIGN architecture.- interioridesign', www.stud103designM 317 595.1000 main 317 572.1236 fax 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 CONSULTANT BIAGI, CHANCE, CUMMIN5, LONDON, TITZER, INC. CONSULTING ENGINEERS INDIANA - KENTUCKY - MISSOURI - NEW JERSEY 1060 Capitol Avenue Suite E240 Indianapolis, IN 46204 www. B C C LT. co m PHONE: 317-968-0239 FAX: 317-968-0235 v Z W CZ d O 0 v LL.. 0 I— i0 t� Z U Q z c v. w c_/ LLJ J LLJ W QJ:F<� < W 0 z 0 vi t -- W Z PROJECT NO. 10977 DATE 2-5-11 REVISIONS CERTI FICAT[ ON S ' NDN No. PE10403912 -c% STATE OF 0 •' /NiD INP •' �ss/ONAL ���\ 2 -a -II SHEET DESCRIPTION ELECTRICAL LEGEND AND GENERAL INFORMATION SHEET NUMBER E001 THIS DRAWING IS THE PROPERTY OF STUDIO 3 DESIGN, INC., ALL RIGHTS RESERVED.