Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
41
w 113 C 0 L F 0 �w ow N In UJ — cn Of .7 CJy O E (� � V J �OQ 1'1 2 3 4 5 0 7 I T 2 I LOUNGE ON CALL RM 205 RM 206 PROVIDE RG6, TYPICAL CONNECT TO EXISTING SPLITTER \ FUTURE TELEVISION SIGNAL SERVICE RM 107 BY OWNER TELEVISION CABLE SCHEMATIC DIAGRAM SCALE: NONE 4 FIRE ALARM CABLE LEGEND TYPE SYSTEM DESCRIPTION DESCRIP. Al F.A. AUDIBLE 1PR, 14 AWG A2 F.A. AUDIBLE 1PR, 14 AWG A3 F.A. AUDIBLE 1 PR, 14 AWG D1 ADDRESSIBLE DATA LOOP EMTNG FABP3-1 V1 F.A. VISUAL 1PR, 14 AWG v2 F.A. VISUAL 1PR, 14 AWG v3 F.A. VISUAL 1 PR, 14 AWG v4 SPARE --- EXISTM FABP3-2 v5 F.A. VISUAL 1PR, 14 AWG v6 F.A. VISUAL 1 PR, 14 AWG v7 SPARE --- v8 SPARE --- 5 NOTES: O1 PATIENT MONITORING CAMERA PROVIDED AND INSTALLED BY OWNER. E.C. SHALL PROVIDE OUTLET BOX IN CEILING AND PULL OWNER FURNISHED CABLE BETWEEN OUTLET BOX AND NURSE OBSERVATION DESK. OWNER TO MAKE FINAL CONNECTIONS. CONTRACTOR SHALL ALLOW SUFFICIENT EXCESS CABLE TO ALLOW FOR TERMINATIONS. CABLE SHALL BE INSTALLED IN 3/4" CONDUIT BETWEEN CABLE TRAY AND NURSE OBSERVATION DESK. COORDINATE EXACT OUTLET BOX LOCATIONS PRIOR TO ROUGH—IN. OUTLET BOX SHALL SUPPORT CAMERA. Q2 PATIENT MONITORING MICROPHONE PROVIDED AND INSTALLED BY OWNER. E.C. SHALL PROVIDE OUTLET BOX IN CEILING AND PULL OWNER FURNISHED CABLE BETWEEN OUTLET BOX AND NURSE OBSERVATION DESK. OWNER TO MAKE FINAL CONNECTIONS. CONTRACTOR SHALL ALLOW SUFFICIENT EXCESS CABLE TO ALLOW FOR TERMINATIONS. CABLE SHALL BE INSTALLED IN 3/4" CONDUIT BETWEEN CABLE TRAY AND NURSE OBSERVATION DESK. COORDINATE EXACT OUTLET BOX LOCATIONS PRIOR TO ROUGH—IN. OUTLET BOX SHALL SUPPORT MICROPHONE. Q PROVIDE TWO (2) 3' SLEEVES THROUGH WALL FOR PATIENT MONITORING CABLES. INSULATE AROUND SLEEVE AND INSIDE TO PROVIDE SOUND BARRIER. ® ROUTE CONDUITS DOWN WALL TO UNDER COUNTER AREA. COORDINATE EXACT TERMINATION POINT WITH OWNER PRIOR TO ROUGH—IN. © 12" WIDE WIRE BASKET CABLE TRAY FOR PATIENT MONITORING CABLES. © PROVIDE IN—CEILING DISTRIBUTED AUDIO SPEECH PRIVACY SYSTEM CONTROL PANEL(S), AMPLIFIERS AND EQUIMENT/ CABLING AS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. REFERENCE NOTES IN ELECTRICAL LEGEND ON SHEET E001 ADDITIONAL INFORMATION. ALL SYSTEM EQUIPMENT AND LAYOUTS FURNISHED TO IDENTIFY SCOPE INTENT. SYSTEM INCLUDING DEVICE LAYOUTS AND CABLING SHALL BE DESIGNED BY AWARDED VENDOR/ CONTRACTOR. AT A MINIMUM SHALL CONSIST OF TWO DISTINCT ZONES WITH SEPARATE CONTROL AS IDENTIFIED. ALL CABLING ASSOCIATED WITH SYSTEM SHALL BE PLENUM RATED AND ROUTED IN NEAT ORGANIZED MANNER UTILIZING J—HOOKS AND/ OR BRIDLE RINGS. SYSTEM SHALL BE STEELCASE CONFIDANTE OR SIMILAR. m 7 01 KEY PLAN SCALE: NONE 12" 0 5' 10' 15' III IIIII I I SCALE: 1/8"=V-0" 12" 0 5' 10' I I I I I I I I 1 SCALE: 1/4"=V-0" m C 0 E F STUDIO THREE DESIGN" architecture interior design www.studia34esign,net 317 595.1000 main 317 572.1236 fax 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 CONSULTANT BIAGI, CHANCE, CUMMINS, LONDON, TITZER, INC. CONSULTING ENGINEERS INDIANA - KENTUCKY - MISSOURI - NEW JERSEY 1060 Capitol Avenue Suite E240 Indianapolis, IN 46204 www. BCCLT.com PHONE: 317-968-0239 FAX: 317-968-0235 v z _ L1 QO _ o v OCV � M N O �o Z U Qz � www -- L� w Lid CS. O Z O tr> � Lid _ z PRO) ECT N O . 10977 DATE 2-8-11 REVISIONS CERTIFICATION � S :..N�NN 2 No. PE 10403912 STATE OF ;t /4NAL 2 -OS -II SHEET DESCIZI PTION THIRD FLOOR SYSTEMS PLAN SHEET NUMBER E401 THIS DRAWING IS THE PROPERTY OF STUDIO 3 DESIGN, INC., ALL RIGHTS RESERVED.