HomeMy WebLinkAboutS000.2 FIRST FLOOR SUBIndianapolis Design Center
352 South County Road 300 E
Danville, IN 46122
317-745-9984
These placement plans have been prepared with the specifications of TrussJoist
products based on project information provided. This service is solely intended
for product application assurance; and, is not intended to circumvent the need
for a design professional as determined by the building codes. The designer
of record and/or builder/framer is responsible to assure these drawings are
compatible with the overall project. These documents are not intended to replace
the building plan (which should be used to determine bearing placement).
Please insure measurements of the foundation match those provided at the time
of design. Builder is responsible to place load bearing members in load path.
Architectural Drawings Prepared By: Structural Drawings Prepared By:
84 Lumber
Danny McLaughlin
Drees
IGA-455
Rev. By Date Comments
FOR SUBMITTAL USE
FIRST FLOOR SYSTEM
NOT TO SCALE Drawn By:
JH
Checked By: Date:
RW XX/XX/20XX
Monticello
180339
Sheet
1 of 2
Confirm this layout with the builder and designer of record. Make
sure all discrepencies are corrected before ordering floor system.
All Dimensions are Approximate and Must Be Field Verified.
TJI 210
TJI 360
TJI 560
Joists by Series
Framing Connector Summary
PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff
H101 2 Simpson HUS1.81/10 Designed 30- 10d common - 10- 10d common - - No No No
H102 2 Simpson ITS1.81/11.88 Designed 2- 10d x 1-1/2 4- 10d x 1-1/2 2- 10d x 1-1/2 - - No No No
H103 4 Simpson IUS2.06/11.88 Designed 10- 10d x 1-1/2 - - - - No No No
H104 3 Simpson IUS3.56/11.88 Designed 12- 10d x 1-1/2 - - - - No No No
Products
PlotID Length Product Plies Net Qty
FJ101 (2 PLY) 22' 0" 11 7/8" TJI® 210 2 2
FJ102 (2 PLY) 18' 0" 11 7/8" TJI® 210 2 4
FJ101 18' 0" 11 7/8" TJI® 210 1 5
FJ103 14' 0" 11 7/8" TJI® 210 1 1
FJ104 8' 0" 11 7/8" TJI® 210 1 4
FJ105 (2 PLY) 22' 0" 11 7/8" TJI® 360 2 2
FJ105 20' 0" 11 7/8" TJI® 360 1 2
FJ106 18' 0" 11 7/8" TJI® 360 1 17
FJ107 22' 0" 11 7/8" TJI® 560 1 4
FJ108 20' 0" 11 7/8" TJI® 560 1 33
BM101 22' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 2 2
BM102 20' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 1 2
BM103 12' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 2 2
BM104 6' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 1 1
BM105 4' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 1 2
Ca101 16' 0" 1 1/8" x 11 7/8" TJ® Rim Board 1 16
Accessories
PlotID Length Product Plies Net Qty
23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF 1 64
Blocking
PlotID Length Product Plies Net Qty
Bk101 2' 0" 11 7/8" TJI® 210 1 7
Bk102 2' 0" 11 7/8" TJI® 360 1 21
LEVEL NOTES
Current Date: 6/19/2018
File Name: IGA-455.jvl
Level Name: First FLoor System
TJ-Pro Rating (Weighted Average): 40
Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 35, joist = FJ107(i8741)
Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 68, joist = FJ104(i8779)
Building Code - Design Methodology: IBC 2006
FLOOR
Floor Container: FC1
Use/Occupancy: ResidentialLivingAreas
Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load
Operator Added Additional Loads
Maximum Allowed Deflection: L/600 Live Load & L/240 Total Load
TJ-Pro Rating Information:
Weighted Average: 40
Directly Applied Ceiling: None
Decking Attachment: Glue and Nail
Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF
Perpendicular Partition: No
Strapping at max 8' o.c.: None
Blocking at max 8' o.c.: No
Poured Flooring: No
Start 19.2" O.C
TJI 11 7/8"
CS
B1
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
CS
CS
B1
B1
B1
B1
Steel B/O
Seel B/O
BM101
BM102
BM102
BM103
BM105 BM105
FJ105 (2 PLY)
FJ101 (2 PLY)
FJ107
FJ102 (2 PLY)
FJ106
FJ102 (2 PLY)
FJ103
BM104
H104
H104
FJ105
FJ105
H101 H101
H103
H103
H102 H102
H103
H103
H104
CS
WC
FJ108
FJ108
FJ108
FJ107
FJ106 FJ101
Bk101
FJ104
Bk102
Bk102
Bk102
Bk102
FJ106 FJ106
CUT 10 HOLES
ILO BULKHEAD
08/02/18
Adam Schriner