HomeMy WebLinkAboutS200.2 SECOND FLOOR SUBIndianapolis Design Center
352 South County Road 300 E
Danville, IN 46122
317-745-9984
These placement plans have been prepared with the specifications of TrussJoist
products based on project information provided. This service is solely intended
for product application assurance; and, is not intended to circumvent the need
for a design professional as determined by the building codes. The designer
of record and/or builder/framer is responsible to assure these drawings are
compatible with the overall project. These documents are not intended to replace
the building plan (which should be used to determine bearing placement).
Please insure measurements of the foundation match those provided at the time
of design. Builder is responsible to place load bearing members in load path.
Architectural Drawings Prepared By: Structural Drawings Prepared By:
84 Lumber
Danny McLaughlin
Drees
IGA-455
Rev. By Date Comments
FOR SUBMITTAL USE
SECOND FLOOR SYSTEM
NOT TO SCALE Drawn By:
JH
Checked By: Date:
RW XX/XX/20XX
Monticello
180339
Sheet
2 of 2
Confirm this layout with the builder and designer of record. Make
sure all discrepencies are corrected before ordering floor system.
All Dimensions are Approximate and Must Be Field Verified.
TJI 210
TJI 360
TJI 560
Joists by Series
Framing Connector Summary
PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff
H201 1 Simpson HHUS5.50/10 Designed 30- 16d common - 10- 16d double shear - - No No No
H202 6 Simpson HU2.1/9 Designed 14- 10d common - 6- 10d x 1-1/2 - - No No Yes
H203 2 Simpson IUS1.81/11.88 Designed 10- 10d x 1-1/2 - 2- 10d x 1-1/2 - - No No No
H204 1 Simpson IUS2.06/11.88 Designed 10- 10d common - - - - 2 No No
H205 2 Simpson IUS2.06/11.88 Designed 10- 10d x 1-1/2 - 2- 10d x 1-1/2 - - No No Yes
H206 49 Simpson IUS2.06/11.88 Designed 10- 10d x 1-1/2 - - - - No No No
H207 3 Simpson IUS2.37/11.88 Designed 10- 10d x 1-1/2 - - - - No No No
H208 1 Simpson IUS3.56/11.88 Designed 12- 10d common - 2- 10d x 1-1/2 - - No No No
Products
PlotID Length Product Plies Net Qty
FJ201 36' 0" 11 7/8" TJI® 210 1 5
FJ202 26' 0" 11 7/8" TJI® 210 1 2
FJ203 24' 0" 11 7/8" TJI® 210 1 7
FJ204 22' 0" 11 7/8" TJI® 210 1 6
FJ205 18' 0" 11 7/8" TJI® 210 1 13
FJ206 14' 0" 11 7/8" TJI® 210 1 11
FJ207 8' 0" 11 7/8" TJI® 210 1 2
FJ208 6' 0" 11 7/8" TJI® 210 1 8
FJ209 4' 0" 11 7/8" TJI® 210 1 4
FJ210 20' 0" 11 7/8" TJI® 360 1 10
BM201 20' 0" 1 3/4" x 18" 2.0E Microllam® LVL 2 2
BM202 20' 0" 1 3/4" x 11 7/8" 2.0E Microllam® LVL 3 3
BM203 20' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 2 6
BM204 14' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 3 3
BM205 12' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 2 2
BM206 8' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 1 1
BM207 6' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 2 4
Ca201 16' 0" 1 1/8" x 11 7/8" TJ® Rim Board 1 10
Accessories
PlotID Length Product Plies Net Qty
1' 0" 3/4" or 7/8" Backer Blocks 1 2
9 1/8" 3/4" x 2 5/16" Web Stiffeners 1 16
23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF 1 61
Blocking
PlotID Length Product Plies Net Qty
Bk201 2' 0" 11 7/8" TJI® 210 1 26
LEVEL NOTES
Current Date: 6/19/2018
File Name: IGA-455.jvl
Level Name: Second Floor System
TJ-Pro Rating (Weighted Average): 43
Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 37, joist = FJ201(i8647)
Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 66, joist = FJ207(i8645)
Building Code - Design Methodology: IBC 2006
FLOOR
Floor Container: FC2
Use/Occupancy: ResidentialLivingAreas
Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load
Operator Added Additional Loads
Maximum Allowed Deflection: L/600 Live Load & L/240 Total Load
TJ-Pro Rating Information:
Weighted Average: 43
Directly Applied Ceiling: Gypsum 1/2"
Decking Attachment: Glue and Nail
Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF
Perpendicular Partition: No
Strapping at max 8' o.c.: None
Blocking at max 8' o.c.: No
Poured Flooring: No
Start 19.2" O.C
TJI 11 7/8"
Start 19.2" O.C
TJI 11 7/8"
A3
A3
A3
A3 A3
A3
A3
A3 A3
B1
E1
E1
H2
CS CS
BM205
BM204
(Dropped) BM B/O
BM207
(Dropped) BM B/O
(Dropped) BM B/O
BM201
BM207
(Dropped) BM B/O
BM202
BM203
(Steel) B/O
BM206
BM203
Ca201
Ca201
BM203
H204
FJ205
CS
H201
H203 H203
H208
WC
WC
SHR WC
SHR
TUB
FJ210
FJ207
FJ201
FJ205 FJ205
FJ209
FJ208
FJ205
FJ202
Bk201
FJ204 FJ203
FJ206
Bk201
Bk201 H206
H207
H202
H206
H206
H206
H206 H205
H206
H206
CUT 6" HOLES
08/02/18
Adam Schriner