Loading...
HomeMy WebLinkAboutS200.2 SECOND FLOOR SUBIndianapolis Design Center 352 South County Road 300 E Danville, IN 46122 317-745-9984 These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intended for product application assurance; and, is not intended to circumvent the need for a design professional as determined by the building codes. The designer of record and/or builder/framer is responsible to assure these drawings are compatible with the overall project. These documents are not intended to replace the building plan (which should be used to determine bearing placement). Please insure measurements of the foundation match those provided at the time of design. Builder is responsible to place load bearing members in load path. Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber Danny McLaughlin Drees IGA-455 Rev. By Date Comments FOR SUBMITTAL USE SECOND FLOOR SYSTEM NOT TO SCALE Drawn By: JH Checked By: Date: RW XX/XX/20XX Monticello 180339 Sheet 2 of 2 Confirm this layout with the builder and designer of record. Make sure all discrepencies are corrected before ordering floor system. All Dimensions are Approximate and Must Be Field Verified. TJI 210 TJI 360 TJI 560 Joists by Series Framing Connector Summary PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff H201 1 Simpson HHUS5.50/10 Designed 30- 16d common - 10- 16d double shear - - No No No H202 6 Simpson HU2.1/9 Designed 14- 10d common - 6- 10d x 1-1/2 - - No No Yes H203 2 Simpson IUS1.81/11.88 Designed 10- 10d x 1-1/2 - 2- 10d x 1-1/2 - - No No No H204 1 Simpson IUS2.06/11.88 Designed 10- 10d common - - - - 2 No No H205 2 Simpson IUS2.06/11.88 Designed 10- 10d x 1-1/2 - 2- 10d x 1-1/2 - - No No Yes H206 49 Simpson IUS2.06/11.88 Designed 10- 10d x 1-1/2 - - - - No No No H207 3 Simpson IUS2.37/11.88 Designed 10- 10d x 1-1/2 - - - - No No No H208 1 Simpson IUS3.56/11.88 Designed 12- 10d common - 2- 10d x 1-1/2 - - No No No Products PlotID Length Product Plies Net Qty FJ201 36' 0" 11 7/8" TJI® 210 1 5 FJ202 26' 0" 11 7/8" TJI® 210 1 2 FJ203 24' 0" 11 7/8" TJI® 210 1 7 FJ204 22' 0" 11 7/8" TJI® 210 1 6 FJ205 18' 0" 11 7/8" TJI® 210 1 13 FJ206 14' 0" 11 7/8" TJI® 210 1 11 FJ207 8' 0" 11 7/8" TJI® 210 1 2 FJ208 6' 0" 11 7/8" TJI® 210 1 8 FJ209 4' 0" 11 7/8" TJI® 210 1 4 FJ210 20' 0" 11 7/8" TJI® 360 1 10 BM201 20' 0" 1 3/4" x 18" 2.0E Microllam® LVL 2 2 BM202 20' 0" 1 3/4" x 11 7/8" 2.0E Microllam® LVL 3 3 BM203 20' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 2 6 BM204 14' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 3 3 BM205 12' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 2 2 BM206 8' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 1 1 BM207 6' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 2 4 Ca201 16' 0" 1 1/8" x 11 7/8" TJ® Rim Board 1 10 Accessories PlotID Length Product Plies Net Qty 1' 0" 3/4" or 7/8" Backer Blocks 1 2 9 1/8" 3/4" x 2 5/16" Web Stiffeners 1 16 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF 1 61 Blocking PlotID Length Product Plies Net Qty Bk201 2' 0" 11 7/8" TJI® 210 1 26 LEVEL NOTES Current Date: 6/19/2018 File Name: IGA-455.jvl Level Name: Second Floor System TJ-Pro Rating (Weighted Average): 43 Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 37, joist = FJ201(i8647) Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 66, joist = FJ207(i8645) Building Code - Design Methodology: IBC 2006 FLOOR Floor Container: FC2 Use/Occupancy: ResidentialLivingAreas Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load Operator Added Additional Loads Maximum Allowed Deflection: L/600 Live Load & L/240 Total Load TJ-Pro Rating Information: Weighted Average: 43 Directly Applied Ceiling: Gypsum 1/2" Decking Attachment: Glue and Nail Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF Perpendicular Partition: No Strapping at max 8' o.c.: None Blocking at max 8' o.c.: No Poured Flooring: No Start 19.2" O.C TJI 11 7/8" Start 19.2" O.C TJI 11 7/8" A3 A3 A3 A3 A3 A3 A3 A3 A3 B1 E1 E1 H2 CS CS BM205 BM204 (Dropped) BM B/O BM207 (Dropped) BM B/O (Dropped) BM B/O BM201 BM207 (Dropped) BM B/O BM202 BM203 (Steel) B/O BM206 BM203 Ca201 Ca201 BM203 H204 FJ205 CS H201 H203 H203 H208 WC WC SHR WC SHR TUB FJ210 FJ207 FJ201 FJ205 FJ205 FJ209 FJ208 FJ205 FJ202 Bk201 FJ204 FJ203 FJ206 Bk201 Bk201 H206 H207 H202 H206 H206 H206 H206 H205 H206 H206 CUT 6" HOLES 08/02/18 Adam Schriner