Loading...
HomeMy WebLinkAbout2EASED EDGE EA. SIDE co - ------------- MT4 OVER TILE BACKER BOARD C7 HARDWOOD TRIM TO MATCH PL11T, FRAMING TILE ON FOUR SIDES. FIRE -RETARDANT WOOD BLOCKING 314" PARTICLE BOARD WITH PLASTIC LAMINATE FINISH 4" H BASE 3/4" SOLID SURFACE OVER 3/4" PARTICLE BOARD SUBSTRATE 10" ; TACKABLE SURFACE (TF1T) GROMMET EXACT LOCATIONS TO BE COORDINATED WITH OWNER VARIES - REFER TO PLAN -------- COUNTERTOP TO BE SOLID SURFACE WITH EASED EDGES = REFER TO ELEVATIONS 518" GYPSUM DRYWALL - RAKKS SUPPORT BRACKET; 3-0" O.C. MAX. 3 518" METAL STUDS AT 16" O.C. 4"H BASE CASEWORK SECTION 2 - HIGH COUNTER - BP5 HEAD SECTION PLAN SECTION FLOOR SLAB RAKKS ELIPSE SUPPORT BRACKET T: 3 5/8" METAL STUDS AT 16" O.C. 3/4" PARTICLE BOARD WITH PLASTIC LAMINATE FINISH - 4" H BASE 1'- 6" VARIES - SEE PLAN ../-.....------------- --.....---------._..-...----------------j-----._._...._._j......._�r..---......----......-...-...__.... ..--'------._..--------- -----'--......--..--- (CURVED WALL) CASEWORK SECTION 3 - COMMUNITY ROOM 3 1 It = 1'-0" BOTTOM OF STRUCTURE FINISH CEILING. REFER TO REFLECTED CEILING PLAN. 5/8" GYPSUM BOARD FURRING CHANNEL (REFER TO CHART BELOW) ADJACENT WALL CONSTRUCTION 5/8" F1-1 1/2" WALL F2- 21 /8" WALL F3- 2118" WALL 5/8" GYPSUM WALL BOARD BASE SECTION WALL PARTITION FX 11/2" =1'-0" NON -RATED BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 1/2" SEALANT SPACE Fx- "X" =METAL FURRING SIZE F1- 7/8" FURRING CHANNEL F2- 1 112" "Z' FURRING CHANNEL F3-1-112" FURRING CHANNEL BASE CABINET WITH PLASTIC LAMINATE FINISH 4" H. BASE 1 CASEWORK SECTION 1 - LOW COUNTER - BP5 ■ HEAD SECTION PLAN SECTION BOTTOM OF STRUCTURE CLIP ANGLE AT EACH STUD zl �I. - FINISH CEILING. REFER TO REFLECTED CEILING PLAN. rwvn ouzo BASE SECTION 518" GYPSUM BOARD ADJACENT WALL CONSTRUCTION. METAL STUDS (REFER TO CHART BELOW) 1/8" ALIGNMENT SPACE (IF APPLICABLE) D1- 2 318" WALL D2- 31/4" WALL D3- 4 318" WALL D4- 4 314" WALL D5- 6 3/4" WALL BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 1/2" SEALANT SPACE D1-15/8" STUD D2- 2112" STUD D3- 3 518" STUD WALL PARTITION D4- 4" STUD DX 1 1/2"= V-0" D5- 6" STUD NON -RATED WALL DEFLECTION TRACK HEAD SECTION SOUND ATTENUATION BATTS PLAN SECTION STEEL STUD RUNNER TRACK. STUDS SCREWED ON EA. SIDE AT BOTTOM FLOOR SLAB BASE SECTION WALL TYPE SYMBOL ABBREVIATION LIST REF. CEILING PLAN SYMBOLS DIMENSION PLAN SYMBOLS � X1" VARIES REFER TO PLAN ----- ---- - --------------------- ABOVE FINISHED FLOOR GROMMET - EXACT - LOCATIONS TO BE MODIFICATIONS COORDINATED WITH OWNER ALTERNATE MAX. MAXIMUM NONE RAKKS SUPPORT BRACKET; COUNTERTOP TO BE SOLID 3'-0" O.C. MAX. SURFACE OR PLASTIC LAMINATE KEYPAD FOR ELECTRIC DOOR LATCH WITH EASED EDGES - REFER TO CONSTRUCTION HEIGHT ELEVATIONS ALUMINUM MECH. 3/4" PARTICLE BOARD WITH 518" GYPSUM DRYWALL PLASTIC LAMINATE FINISH 101 SHEET NUMBER 3 518" METAL STUDS AT 16" O.C. 4"H BASE 4"H BASE 1 CASEWORK SECTION 1 - LOW COUNTER - BP5 ■ HEAD SECTION PLAN SECTION BOTTOM OF STRUCTURE CLIP ANGLE AT EACH STUD zl �I. - FINISH CEILING. REFER TO REFLECTED CEILING PLAN. rwvn ouzo BASE SECTION 518" GYPSUM BOARD ADJACENT WALL CONSTRUCTION. METAL STUDS (REFER TO CHART BELOW) 1/8" ALIGNMENT SPACE (IF APPLICABLE) D1- 2 318" WALL D2- 31/4" WALL D3- 4 318" WALL D4- 4 314" WALL D5- 6 3/4" WALL BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 1/2" SEALANT SPACE D1-15/8" STUD D2- 2112" STUD D3- 3 518" STUD WALL PARTITION D4- 4" STUD DX 1 1/2"= V-0" D5- 6" STUD NON -RATED WALL DEFLECTION TRACK HEAD SECTION SOUND ATTENUATION BATTS PLAN SECTION STEEL STUD RUNNER TRACK. STUDS SCREWED ON EA. SIDE AT BOTTOM FLOOR SLAB BASE SECTION WALL TYPE SYMBOL ABBREVIATION LIST REF. CEILING PLAN SYMBOLS DIMENSION PLAN SYMBOLS � X1" JX -� - SUFFIX INDICATES HORIZONTAL A.F.F. ABOVE FINISHED FLOOR JT. JOINT MODIFICATIONS ALT. ALTERNATE MAX. MAXIMUM NONE SUFFIX INDICATES MODIFICATIONS TO WALL ■■■r l DETAIL KEYPAD FOR ELECTRIC DOOR LATCH NEON ■m=N CONSTRUCTION HEIGHT ALUM. ALUMINUM MECH. MECHANICAL / MECHANICALLY ■■Gov NUMERICAL INDICATION OF STUD/MASONRY SIZE 101 SHEET NUMBER CUBICLE CURTAIN TRACK AND CURTAIN ■M'� 2'x4' LIGHTING FIXTURE APP. APPLICABLE MER. MOLDED EPDXY RESIN H. INDICATES CONSTRUCTION TYPE ARCH. ARCHITECTURAL MFGR. MANUFACTURERIS WALL TYPE AXON. AXONOMETRIC DRAWING MIN. MINIMUM UNLESS NOTED OTHERWISE. GENERAL WALL TYPE NOTES B.C. BRICK COURSE M.O. MASONRY OPENING B. ALL LAY -IN ACOUSTICAL CEILINGS SHALL BE TYPE 3, UNLESS NOTED SUPPLY AIR GRILLE BRICK COURSES DOOR NUMBER DESIGNATION SUPPLY AIR GRILLE PUSH PLATE FOR AUTO DOOR OPERATOR CEILING HEIGHT ABOVE FINISH FLOOR PP O.C. ON CENTER READER FOR ELECTRIC DOOR LATCH A. DIMENSIONS IN PLAN AND ELEVATION ARE TAKEN TO THE FACE OF FINISH B.O. BOTTOM OF DRYWALL OR CENTER LINE OF COLUMN, UNLESS NOTED OTHERWISE. O.H. OPPOSITE HAND B. ALL INTERIOR WALLS SHALL BE TYPE'BS UNLESS NOTED OTHERWISE. ALL CL. CENTERLINE COLUMN SURROUNDS SHALL BE WALL TYPE'A2' UNLESS NOTED BULKHEADS ABOVE CASEWORK SHALL BE INSTALLED AT T-2" ABOVE FINISHED O.F.0.1. OWNER FURNISHED, OWNER 1. OTHERWISE. CLR. CLEAR FLOOR. D. REFER INSTALLED C. PROVIDE FULL HEIGHT STRUCTURAL STUDS TO THE STRUCTURE ABOVE CEILING. INDICATES GYPSUM BOARD ON ONE SIDE TO STOP 6" ABOVE FINISHED F.E.C. FIRE EXTINGUISHER CABINET FINISHES. AT ALL CORNERS, AT DOOR AND BORROWED LIGHT FRAMES, JAMBS, C.M.U. CONCRETE MASONRY UNIT O.F.C.I. OWNER FURNISHED, E. FIRE SAFETY AND BEHIND ALL WALL MOUNTED EQUIPMENT AND/ OR CASEWORK. M a DOOR WITH AUTOMATIC DOOR OPERATOR 3. INDICATES PARTIAL HEIGHT WALL. CONTRACTOR INSTALLED W/ WITH D. FURNISH AND INSTALL FIRE STOP SEALANT WHERE GYPSUM WALL BOARD CONFIG. CONFIGURATION BLANKETS GA. GAUGE MEETS FIREPROOFING ON COLUMNS, BEAMS, AND METAL DECK AT FIRE F. CAN LIGHTS WITHIN GYPSUM DRYWALL BULKHEADS SHALL BE INSTALLED AT P. PLASTIC a. RATED PARTITIONS. CONT. CONTINUOUS /CONTINUED CENTERLINE OF BULKHEAD WIDTH. E. ALL PENETRATIONS THROUGH FIRE AND SMOKE RATED WALLS SHALL BE b. C. INDICATES ADDITIONAL LAYER OF 5!8" GYPSUM BOARD OVER WALL. INDICATES FOIL -FACED GYPSUM BOARD. RAD./RI RADIUS FIRE STOPPED AS NECESSARY TO MAINTAIN RATINGS. C.F.C.I. CONTRACTOR FURNISHED, G.S.F. GROSS SQUARE FEET F. AT FIRE RATED WALLS, PROVIDE TESTED FIRE STOPPING SYSTEM AT CONTRACTOR INSTALLED REF. REFER! REFERENCE HEAD OF WALL. AT ALL NON -FIRE RATED WALLS, INCLUDING SOUND F.D. RESISITANT WALLS, SMOKE PARTITIONS AND CORRIDOR WALLS, PACK C.J. CONTROL JOINT R.O. ROUGH OPENING ® FLOOR DRAIN VOID SPACE BETWEEN METAL DECK FLUTES AND TOP OF PARTITION WITH XX NEW COLUMN LINE FIRE SAFING AND SEAL GAP AT DRYWALL WITH ACOUSTICAL SEALANT. DIMS. DIMENSIONS SIM. SIMILIAR G. ALL WALLS SHALL BE TREATED AS SOUND RESISTANT WALLS (UNLESS - - - - CURTAIN TRACK W/ CURTAIN INT. INTERIOR E EXPANSION JOINT AT S F SQUARE FEET MEMO - Oman SUSPENDED LAY -IN CEILING SYSTEM J CR ■�a� - - -{ XX) EWE ._r RECESSED "CAN" TYPE LIGHT FIXTURE OR PENDANT NONE DETAIL INDICATOR ■■■r l DETAIL KEYPAD FOR ELECTRIC DOOR LATCH NEON ■m=N CEILING MOUNTED EXIT LIGHT `- DETAIL NUMBER ■■0r - SIM -�-- ■■Gov 101 SHEET NUMBER CUBICLE CURTAIN TRACK AND CURTAIN ■M'� 2'x4' LIGHTING FIXTURE ROOM ® VARIES VARIES 5/8" GYPSUM BOARD ON EACH SIDE OF STUDS METAL STUDS (REFER TO CHART BELOW) 132- 3 314" WALL 63- 4 7/8" WALL 66- 71/4" WALL BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 1/2" SEALANT SPACE (FIRESTOP AT RATED PARTITIONS) BX-'X'=METAL STUD SIZE WALL PARTITION 132-2112" METAL STUDS BX 1 1/2" =1'-0" B3-3 518" METAL STUDS 66-6" METAL STUDS 1 HOUR RATED PARTITION; UL #V450 (WHERE NOTED ON PLAN) HEAD SECTION SOUND, BATTS PLAN SECTION STEEL STUD RUNNER STUDS SCREWED AT FLOOR SLAB BASE SECTION METAL STUDS (REFER TO CHART BELOW) VARIES VARIES 518" ke-A2- 31I8" WALL A3- 41 /4" WALL A6- 6 518" WALL 5/8" GYPSUM WALL BOARD NON -RATED BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 1/2" SEALANT SPACE AX-'X'=METAL STUD SIZE WALL PARTITION A2-2112" METAL STUDS A3-3 5/8" METAL STUDS 1 1l2" =1'-0" A6-6" METAL STUDS GENERAL ARCH. PLAN NOTES A. REFER TO SHEET A010.5 FOR TOILET ACCESSORIES SCHEDULE. B. PAINTING CONTRACTOR SHALL LABEL, ABOVE CEILING, ALL FIRE RATED WALL CONSTRUCTION AND SMOKE BARRIER WALL CONSTRUCTION IN ACCORDANCE WITH SPECIFICATION. C. REFER TO SHEET A010.5 FOR EQUIPMENT SCHEDULE. REFER TO MIE/P DRAWINGS TO COORDINATE CONNECTIONS. D. ALL FURNITURE SHOWN FOR REFERENCE ONLY. E. REFER TO INTERIOR FINISH PLANS FOR LOCATIONS OF HANDRAILS, BUMPRAILS, CORNER GUARDS, AND WALL PROTECTION. F. REFER TO INTERIOR FINISH PLANS FOR WINDOW SHADE TYPES AND LOCATIONS. G. PROVIDE (2) COAT HOOKS CENTERED ON BACK SIDE OF DOOR IN EACH FITTING ROOM. ALL COAT HOOKS TO BE MOUNTED AT 5'-6" A.F.F. TOILET ACCESSORIES - BP5 1 SURFACE MOUNTED PAPER TOWEL DISPENSER 2 SURFACE MOUNTED SOAP DISPENSER 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com St. Vincent CarelI�os ital WOMEN'S CENTER CARMEL, IN BP #5 CONSTRUCTION DOCUMENTS WOMEN'S CENTER CONNECTOR NEYP LAN KN MARK DATE DESCRIPTION ����� ««L.HO�Ii r" � 4�G, s TE,Q� F� No. AR00034069 I STATE OF DIA, I A, 41?CH 11 • WALL TYPES, GENERAL NOTES AND DETAILS CLIENT NO.: 0461 PROJECT NO. 04610082 SCALE As indicated DATE SEPT. 12, 2014 COORD DRAWN A01 0.5 - NEW COLUMN LINE SUSPENDED LAY -IN CEILING SYSTEM CR LOBBY LIGHT FIXTURE (EXISTING) - - -{ XX) EXISTING COLUMN LINE RECESSED "CAN" TYPE LIGHT FIXTURE OR PENDANT ( AREA OF DETAIL INDICATOR l DETAIL KEYPAD FOR ELECTRIC DOOR LATCH CEILING MOUNTED EXIT LIGHT `- DETAIL NUMBER CHAIN HUNG LIGHT FIXTURE - SIM -�-- SIMILAR 101 SHEET NUMBER CUBICLE CURTAIN TRACK AND CURTAIN BOTTOM RUNNER TRACK. 2'x4' LIGHTING FIXTURE ROOM ® ROOM NAME DESIGNATION ROOM NUMBER DESIGNATION KP �-' H. 2'x2' LIGHTING FIXTURE 1O PLAN NOTE DESIGNATION 1'x4' LIGHTING FIXTURE LAY -IN ACOUSTICAL CEILINGS SHALL BE INSTALLED AT 9'-0" ABOVE FINISH WALL TYPE WALL TYPE SUFFIX ACOUSTICAL CEILING TILE - TYPE FLOOR, UNLESS NOTED OTHERWISE. RETURN AIR GRILLE EXHAUST AIR GRILLE B. ALL LAY -IN ACOUSTICAL CEILINGS SHALL BE TYPE 3, UNLESS NOTED SUPPLY AIR GRILLE DOOR NUMBER DESIGNATION SUPPLY AIR GRILLE PUSH PLATE FOR AUTO DOOR OPERATOR CEILING HEIGHT ABOVE FINISH FLOOR PP WALL TYPES SUFFIX F- DRYWALL BULKHEAD/CEILINGCARD READER FOR ELECTRIC DOOR LATCH VARIES VARIES 5/8" GYPSUM BOARD ON EACH SIDE OF STUDS METAL STUDS (REFER TO CHART BELOW) 132- 3 314" WALL 63- 4 7/8" WALL 66- 71/4" WALL BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 1/2" SEALANT SPACE (FIRESTOP AT RATED PARTITIONS) BX-'X'=METAL STUD SIZE WALL PARTITION 132-2112" METAL STUDS BX 1 1/2" =1'-0" B3-3 518" METAL STUDS 66-6" METAL STUDS 1 HOUR RATED PARTITION; UL #V450 (WHERE NOTED ON PLAN) HEAD SECTION SOUND, BATTS PLAN SECTION STEEL STUD RUNNER STUDS SCREWED AT FLOOR SLAB BASE SECTION METAL STUDS (REFER TO CHART BELOW) VARIES VARIES 518" ke-A2- 31I8" WALL A3- 41 /4" WALL A6- 6 518" WALL 5/8" GYPSUM WALL BOARD NON -RATED BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 1/2" SEALANT SPACE AX-'X'=METAL STUD SIZE WALL PARTITION A2-2112" METAL STUDS A3-3 5/8" METAL STUDS 1 1l2" =1'-0" A6-6" METAL STUDS GENERAL ARCH. PLAN NOTES A. REFER TO SHEET A010.5 FOR TOILET ACCESSORIES SCHEDULE. B. PAINTING CONTRACTOR SHALL LABEL, ABOVE CEILING, ALL FIRE RATED WALL CONSTRUCTION AND SMOKE BARRIER WALL CONSTRUCTION IN ACCORDANCE WITH SPECIFICATION. C. REFER TO SHEET A010.5 FOR EQUIPMENT SCHEDULE. REFER TO MIE/P DRAWINGS TO COORDINATE CONNECTIONS. D. ALL FURNITURE SHOWN FOR REFERENCE ONLY. E. REFER TO INTERIOR FINISH PLANS FOR LOCATIONS OF HANDRAILS, BUMPRAILS, CORNER GUARDS, AND WALL PROTECTION. F. REFER TO INTERIOR FINISH PLANS FOR WINDOW SHADE TYPES AND LOCATIONS. G. PROVIDE (2) COAT HOOKS CENTERED ON BACK SIDE OF DOOR IN EACH FITTING ROOM. ALL COAT HOOKS TO BE MOUNTED AT 5'-6" A.F.F. TOILET ACCESSORIES - BP5 1 SURFACE MOUNTED PAPER TOWEL DISPENSER 2 SURFACE MOUNTED SOAP DISPENSER 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com St. Vincent CarelI�os ital WOMEN'S CENTER CARMEL, IN BP #5 CONSTRUCTION DOCUMENTS WOMEN'S CENTER CONNECTOR NEYP LAN KN MARK DATE DESCRIPTION ����� ««L.HO�Ii r" � 4�G, s TE,Q� F� No. AR00034069 I STATE OF DIA, I A, 41?CH 11 • WALL TYPES, GENERAL NOTES AND DETAILS CLIENT NO.: 0461 PROJECT NO. 04610082 SCALE As indicated DATE SEPT. 12, 2014 COORD DRAWN A01 0.5 NOTED OTHERWISE). SEAL AROUND ALL PENETRATIONS AND INSTALL SOUND ATTENTION BATTS FULL HEIGHT. FIT INSULATION TIGHT AROUND J. BRICK VENEER CR DUCT AND PIPE PENETRATIONS. ALL SOUND RESISTANT WALLS WITH ELEC. ELECTRICAL S.S. STAINLESS STEEL GENERAL RC PLAN NOTES KEYPAD FOR ELECTRIC DOOR LATCH SOUND ATTENUATION BATTS SHALL HAVE ACOUSTICAL SEALANT UNDER BOTTOM RUNNER TRACK. S.S.G. STRUCTURAL SILICON GLAZED KP �-' H. ALL STUDS SHALL BE AT 16" O.C. UNLESS NOTED OTHERWISE. ELEV. ELEVATION A. ALL LAY -IN ACOUSTICAL CEILINGS SHALL BE INSTALLED AT 9'-0" ABOVE FINISH STRUC. STRUCTURAL FLOOR, UNLESS NOTED OTHERWISE. PROXIMITY SENSOR EQ. EQUAL B. ALL LAY -IN ACOUSTICAL CEILINGS SHALL BE TYPE 3, UNLESS NOTED PS T.O. TOP OF WALL TYPES SUFFIX E.W.C. ELECTRIC WATER COOLER U.N.O. UNLESS NOTED OTHERWISE OTHERWISE. C. ALL GYPSUM DRYWALL BULKHEADS SHALL BE INSTALLED AT 8'-6" ABOVE GYPSUM DRYWALL �- TOUCHLESS ACTUATOR TA EXT. EXTERIOR FINISHED FLOOR, UNLESS NOTED OTHERWISE. ALL V. VARIES BULKHEADS ABOVE CASEWORK SHALL BE INSTALLED AT T-2" ABOVE FINISHED 1. INDICATES ENTIRE WALL CONSTRUCTION TO STOP 6" ABOVE FINISHED F.E. FIRE EXTINGUISHER VERT. VERTICAL / VERTICALLY FLOOR. D. REFER TO INTERIOR FINISH PLANS FOR GYPSUM DRYWALL BULKHEAD 2. CEILING. INDICATES GYPSUM BOARD ON ONE SIDE TO STOP 6" ABOVE FINISHED F.E.C. FIRE EXTINGUISHER CABINET FINISHES. o �- NEW WALL NEW DOOR CEILING. F.R.T. FIRE RETARDANT TREATED V.I.F. VERIFY IN FIELD E. FIRE SAFETY RATINGS NOT SHOWN ON REFLECTED CEILING PLANS. REFER TO LIFE PLANS OR DIMENSION PLANS FOR WALL RATING LOCATIONS. M a DOOR WITH AUTOMATIC DOOR OPERATOR 3. INDICATES PARTIAL HEIGHT WALL. W/ WITH BLANKETS GA. GAUGE F. CAN LIGHTS WITHIN GYPSUM DRYWALL BULKHEADS SHALL BE INSTALLED AT �-�- NEW WALL a. INDICATES NO SOUND ATTENUATION QS DIAMETER CENTERLINE OF BULKHEAD WIDTH. NEW DOOR b. C. INDICATES ADDITIONAL LAYER OF 5!8" GYPSUM BOARD OVER WALL. INDICATES FOIL -FACED GYPSUM BOARD. GALV. GALVANIZED INT. ELEV. SYMBOL LEGEND DOOR WITH MAGNETIC HOLD OPEN DEVICES G.S.F. GROSS SQUARE FEET F.D. GYP. GYPSUM ® FLOOR DRAIN XX NEW COLUMN LINE HORIZ. HORIZONTAL / HORIZONTALLY - - - - CURTAIN TRACK W/ CURTAIN INT. INTERIOR 1SIM SECTION INDICATOR A101 WALL RATINGS L.C.C. LEAD COATED COPPER ( AREA OF DETAIL INDICATOR 1 -HOUR RATED FIRE BARRIER -1H �•�•�•�•�•� l DETAIL DETAIL NUMBER \- SIM SIMILAR 1 _.--- 2 -HOUR RATED FIRE BARRIER- 2H �••�••�••�•• 101 SHEET NUMBER 3 -HOUR RATED FIRE BARRIER- 3H �•••�•••�•••� FASTEN STEEL RUNNER TO METAL DECK. FRICTION FIT METAL STUDS TO AND FASTEN GYPSUM BOARD TO STUDS. DO NOT GENERAL DIM. PLAN NOTES DEFLECTION TRACK O ELEVATION NOTE DESIGNATION FASTEN TO DEFLECTION TRACK. MAINTAIN GAP BETWEEN STEEL DEFLECTION TRACK AND METAL STUD/GYPSUM BOARD TO ACCOMMODATE A REFER TO SHEET A010.5 FOR WALL TYPES. STRUCTURAL DEFLECTION. ®= TOILET ACCESSORY B. REFER TO SHEET A500.5 FOR OPENING SCHEDULE AND TYPICAL INTERIOR DOOR OPENING DETAILS. STEEL RUNNER WITH MIN. 2 FLANGES C. CONTRACTOR SHALL VERIFY ALL EXISTING CONSTRUCTION AND NOTIFY THE COMPRESSED SAFING INSULATION. GENERAL INTELEVNOTES ARCHITECT/ENGINEER OF ANY DISCREPANCIES. (FIRESTOPPING AT RATED . . D. ALL DIMENSIONS ARE TO CENTER OF COLUMN LINES, FACE OF DRYWALL OR PARTITIONS) A. REFER TO SHEET A010.5 FOR THE EQUIPMENT LIST AND TOILET TO FACE OF EXISTING WALL FINISH, UNLESS NOTED OTHERWISE. METAL DECK. REFER TO STRUCTURAL - ACCESSORIES SCHEDULE. REFER TO M/E/P DRAWINGS TO COORDINATE E. REFER TO'IF' SHEET SERIES FOR ADDITIONAL INTERIOR FINISH INFORMATION. DRAWINGS. CONNECTIONS F. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL FOR ADDITIONAL B. ALL DIMENSIONS ARE TAKEN TO THE FACE OF FINISHED MATERIAL. INFORMATION. G ALL INTERIOR GYPSUM DRYWALL WALLS SHALL BE TYPE'B3' UNLESS NOTED N CONTINUOUS 20 GA. SHEET METAL - C. COORDINATE BULKHEAD HEIGHTS INDICATED ON INTERIOR ELEVATIONS WITH OTHERWISE. `-OTHERWISE. FASTENED TO DECK WITH WIDTH TO SPAN 3 RIBS MIN. THAT SHOWN ON THE REFLECTED CEILING PLAN. CONFIRM ANY DISCREPANCIES WITH THE ARCHITECT PRIOR TO CONSTRUCTION. H. ALL INTERIOR GYPSUM DRYWALL COLUMN SURROUNDS SHALL BE WALL TYPE 'A2' UNLESS NOTED OTHERWISE. CONTINUOUS ACOUSTIC SEALANT D. PROVIDE A 4" HIGH INTEGRAL BACK SPLASH ON ALL COUNTERS WITH RECESSED SINKS. INSTALL SIDE SPLASHES WHERE THESE COUNTERS I. PROVIDE 5/8" GYPSUM DRYWALL ON INSIDE OF ALL TENANT SPACE WALLS. BOTH SIDES. (FIRESTOPPING AT ABUT A WALL, UNLESS NOTED OTHERWISE. GYPSUM DRYWALL TO BE FOIL FACED AT ALL EXTERIOR WALL LOCATIONS. RATED PARTITIONS) E. PROVIDE ADJUSTABLE SHELVING WITHIN ALL WALL AND BASE CABINETRY AS J ALL COLUMN SURROUNDS SHALL BE 1'-0" FROM CENTERLINE OF COLUMN TO EXTERIOR FACE OF DRYWALL IN ALL DIRECTIONS, UNLESS NOTED OTHERWISE. SHOWN BY DASHED LINE. COPE GYPSUM BOARD AROUND F. PROVIDE 12" CLEAR INTERIOR DIMENSION ON ALL UPPER WALL CABINETS K DOOR FRAMES SHALL BE TYPICALLY 6" FROM PERPENDICULAR CORNER TO METAL DECK PROFILE. DOOR OPENING (INSIDE OF FRAME), ULESS NOTED OTHERWISE. UNLESS NOTED OTHERWISE. METAL EDGE TRIM WHERE G. COORDINATE ALL WALL OUTLETS TO AVOID CONFLICT WITH CASEWORK. ARCH. PLAN SYMBOLS EXPOSED TO VIEW. H. INSTALL WOOD BLOCKING TO STUDS TO SUPPORT ALL WALL -MOUNTED REFER TO PARTITION TYPES FOR CABINETRY AND EQUIPMENT AS REQUIRED. WALL CONSTRUCTION. I. ALL CASEWORK SHALL BE FINISHED WOOD UNLESS NOTED OTHERWISE. PARALLEL TO RIBS OF DECK PERPENDICULAR TO RIBS OF DECK J. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTING - - NEW COLUMN LINE CABINETRY. K. PROVIDE FILLER PANELS AT ALL LOCATIONS WHERE CABINETRY ABUTS A EXISTING COLUMN LINE WALL. L. ALL BASE CABINETS SHALL BE 2'-0" DEEP UNLESS NOTED OTHERWISE. AREA OF TYP. METAL STUD PARTITION HEAD DETAIL TAIL DETAIL ( DETAIL INDICATOR �� 1 1/2" =1'-0" NON-BEARING EQUIPMENT SCHEDULE- BP5 _J DETAIL NUMBER NUMBER NAME REMARKS 1 SIM SIMILAR 200 COPIER- FLOOR O.F.0.1. 101 SHEET NUMBER 201 COMPUTER MONITOR O.F.0.1. -I ROOM ROOM NAME DESIGNATION 202 SINGLE DOOR REFRIGERATOR 6F.0 DOME ROOM NUMBER DESIGNATION BOTTOM OF STRUCTURE _ - BOTTOM OF STRUCTURE 203 HIGH DENSITY STORAGE O.F.0.1. _ 204 CASH REGISTER O.F.0.1. O PLAN NOTE DESIGNATION 205 DISHWASHER - GE PROFILE O.F.0.1. 1/2" SEALANT SPACE DEFLECTION TRACK 1/2" SEALANT SPACE 206 OVEN - GE PROFILE O.F.0.1. 1� -F- TOILET ACCESSORY NOTE DESIGNATION (FIRESTOP SYSTEM AT 207 COOKTOP - GE PROFILE O.F.0.1. RATED PARTITIONS) 16 GAUGE HORIZONTAL 208 MICROWAVE - GE PROFILE O.F.0.1. EQUIPMENT DESIGNATION. REFER FASTEN GYPSUM BOARD STEEL STRAPS AT 32" FASTEN GYPSUM BOARD 209 REFRIGERATOR - GE PROFILE O.F.0.1. TO EQUIPMENT SCHEDULE. TO STUDS NOT TO THE O.C. VERTICALLY. TO STUDS NOT TO THE 210 CEILING MOUNTED PROJECTOR O.F.0.1. 1 TOP TRACK ANCHOR TO EACH STUD. TOP TRACK 211 CEILING MOUNTED SCREEN -LARGE O.F.0.1. 212 EXHAUST HOOD O.F.0.1. 4A000 2 ELEVATION TAG 3 - - - - CURTAIN TRACK W/ CURTAIN VARIES VARIES 5/8" GYPSUM BOARD ON EACH SIDE OF STUDS METAL STUDS (REFER TO CHART BELOW) 132- 3 314" WALL 63- 4 7/8" WALL 66- 71/4" WALL BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 1/2" SEALANT SPACE (FIRESTOP AT RATED PARTITIONS) BX-'X'=METAL STUD SIZE WALL PARTITION 132-2112" METAL STUDS BX 1 1/2" =1'-0" B3-3 518" METAL STUDS 66-6" METAL STUDS 1 HOUR RATED PARTITION; UL #V450 (WHERE NOTED ON PLAN) HEAD SECTION SOUND, BATTS PLAN SECTION STEEL STUD RUNNER STUDS SCREWED AT FLOOR SLAB BASE SECTION METAL STUDS (REFER TO CHART BELOW) VARIES VARIES 518" ke-A2- 31I8" WALL A3- 41 /4" WALL A6- 6 518" WALL 5/8" GYPSUM WALL BOARD NON -RATED BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 1/2" SEALANT SPACE AX-'X'=METAL STUD SIZE WALL PARTITION A2-2112" METAL STUDS A3-3 5/8" METAL STUDS 1 1l2" =1'-0" A6-6" METAL STUDS GENERAL ARCH. PLAN NOTES A. REFER TO SHEET A010.5 FOR TOILET ACCESSORIES SCHEDULE. B. PAINTING CONTRACTOR SHALL LABEL, ABOVE CEILING, ALL FIRE RATED WALL CONSTRUCTION AND SMOKE BARRIER WALL CONSTRUCTION IN ACCORDANCE WITH SPECIFICATION. C. REFER TO SHEET A010.5 FOR EQUIPMENT SCHEDULE. REFER TO MIE/P DRAWINGS TO COORDINATE CONNECTIONS. D. ALL FURNITURE SHOWN FOR REFERENCE ONLY. E. REFER TO INTERIOR FINISH PLANS FOR LOCATIONS OF HANDRAILS, BUMPRAILS, CORNER GUARDS, AND WALL PROTECTION. F. REFER TO INTERIOR FINISH PLANS FOR WINDOW SHADE TYPES AND LOCATIONS. G. PROVIDE (2) COAT HOOKS CENTERED ON BACK SIDE OF DOOR IN EACH FITTING ROOM. ALL COAT HOOKS TO BE MOUNTED AT 5'-6" A.F.F. TOILET ACCESSORIES - BP5 1 SURFACE MOUNTED PAPER TOWEL DISPENSER 2 SURFACE MOUNTED SOAP DISPENSER 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com St. Vincent CarelI�os ital WOMEN'S CENTER CARMEL, IN BP #5 CONSTRUCTION DOCUMENTS WOMEN'S CENTER CONNECTOR NEYP LAN KN MARK DATE DESCRIPTION ����� ««L.HO�Ii r" � 4�G, s TE,Q� F� No. AR00034069 I STATE OF DIA, I A, 41?CH 11 • WALL TYPES, GENERAL NOTES AND DETAILS CLIENT NO.: 0461 PROJECT NO. 04610082 SCALE As indicated DATE SEPT. 12, 2014 COORD DRAWN A01 0.5