HomeMy WebLinkAboutM003.0Toe Nail
ZB
ZB
TB
XB
XB1
RTG
T2B
PB
PG1
MG
MB
P2
P2
P3
PG4
P4
P5
PG7
P8
PB8
RPG
PG6
LB
TGE
Z
PG5
PG2
PJ3
PJ1
PJ2
PG3
VR1
VR2
VR3
VP2
VP3
VL1
VL2
VL3
VL4
VL5
VM
V1X
V2X
V3X
V4X
VR4
JUS26
JUS26
JUS26
HUS26
JUS26
JUS26
JUS26
JUS26
JUS26 JUS26
JUS26
JUS26
JUS26
JUS26
JUS26
JUS26 JUS26
JUS26 JUS26
JUS26 JUS26
JUS26
JUS26
JUS26
THDH26-2
THDH26-2
HUS26
JUS26
THDH26-2
THDH26-2 THDH26-2
JUS26
HUS26
JUS26 HUS26
JUS26 HUS26
JUS26
Z(2)
R(9)
P(4)
VP1(3)
L(2) L1(3)
T1(2) T(5)
P6(2)
T2(8)
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
9-11
2-00-00
2-00-00
2-00-00
1-09-12
2-00-00
2-00-00
2-00-00
2-00-00
1-01-12
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
1-09-12
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
1-10-08
2-00-00
2-00-00
2-00-00
11-08
2-00-08
1-05-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
Order #: 18080049
The Grove at Legacy - 202B
7074 Cherry Creek Boulevard
Carmel, Indiana 46033
Carter Lumber
2901 N. Morton St.
Franklin, Indiana 46131
(317) 346-1300
THIS IS A TRUSS PLACEMENT DIAGRAM ONLY. These trusses are designed as individual building components to be incorporated
into the building design at the specification of the building designer. See individual design sheets for each truss design identified on
the placement drawing. The building designer is responsible for temporary and permanent bracing of the roof and floor system and
for the overall structure. The design of the truss support structure including headers, beams, walls, and columns is the responsibility of
the building designer. For general guidance regarding bracing, consult "Bracing of Wood Trusses" available from the Truss Plate
Institute, 583 D'Onifrio Drive; Madison, WI 53179.
SHOP DRAWING APPROVAL
THIS LAYOUT IS THE SOLE SOURCE FOR FABRICATION OF TRUSSES AND VOIDS ALL PREVIOUS ARCHITECTURAL OR
OTHER TRUSS LAYOUTS. REVIEW AND APPROVAL OF THIS LAYOUT MUST BE RECEIVED BEFORE ANY TRUSSES WILL
BE BUILT. VERIFY ALL COND ITIONS TO INSURE AGAINST CHANGES THAT WILL RESULT IN EXTRA CHARGES TO YOU.
REVIEWED BY:__________________________ APPROVED BY:______________________________ DATE:___________
Pyatt Builders
Scale: NTS Date: 8/22/18 Drawn By: K. Bronnenberg
Model
Sausolito
Notes:
1) Valley trusses are designed to sit on sheathing.
2) Installation of all temporary and permanent braces is essential.
See truss drawings, BCSI-1 Building Component Safety information
and building designers requirements.
3) Provide solid bearing for beams and girders. See Code and/or
building deigners requirements.
4) Truss are NOT designed to be field modified unless noted
otherwise. If any alterations are to be considered ALWAYS consult
a qualified truss designer or engineer BEFORE making any alterations.
5) Add/remove overhangs as needed.
Multi-Ply Girder Truss:
See drawing of multi-ply girders for fastening pattern to connect plys
so they act as one. All plys must be fastened together before supported
trusses or framing is attached to girders.
Hangers:
Install all hangers per manufacturers requirements.
08/30/18
Mike Sheeks