Loading...
HomeMy WebLinkAbouta008WILLIAM L.KAUF H OL Z A RCHITECT02 WINDOW JAMB @ HORIZONTAL SIDING SCALE: HORIZONTAL SIDING, TYPICAL J-CHANNEL TRIM, TYPICAL PLAN DETAIL 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G 03 WINDOW SILL @ HORIZONTAL SIDING SCALE: 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G WATER DIVERTER, TYPICAL: - EXTEND TO 2" BEYOND EA. SIDE OF WINDOW - REFER TO DTL. THIS SHT 08 WINDOW HEAD @ HORIZONTAL SIDING SCALE: HORIZONTAL SIDING, TYPICAL J-CHANNEL TRIM, TYPICAL 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G 04 WINDOW HEAD w/ WOOD TRIM @ HORIZ. SIDING SCALE: HORIZONTAL SIDING, TYPICAL STRUCTURAL SHEATHING, TYPICAL J-CHANNEL TRIM, TYPICAL 1x TRIM, TYPICAL - REFER TO ELEVATIONS FOR SIZES AND PROFILES 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G 05 WINDOW JAMB w/ WOOD TRIM @ HORIZ. SIDING SCALE: HORIZONTAL SIDING, TYPICAL PLAN DETAIL J-CHANNEL TRIM, TYPICAL 1x TRIM, TYPICAL - REFER TO ELEVATIONS FOR SIZES AND PROFILES 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G 07 WINDOW SILLS @ HORIZONTAL VINYL SIDING SCALE: 3" = 1'-0" WATER DIVERTER ELEVATION DETAIL WATER DIVERTER -CUT FROM SCRAP SIDING OR COIL STOCK - EXTEND TO 2" BEYOND EA. END OF WINDOW J-CHANNEL WITH SQUARED CORNERS 2"SET DIVERTER ON NAIL HEM OF THE LAST FULL COURSE OF SIDING LAST FULL COURSE OF SIDING 2" TO 2 " BEYO N D OTHE R SIDE OF WIND O W 06 WINDOW SILL w/ WOOD TRIM @ HORIZ. SIDING SCALE: 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE. - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G. WATER DIVERTER, TYPICAL: - EXTEND TO 2" BEYOND EA. SIDE OF WINDOW - REFER TO DTL. THIS SHT 1x TRIM, TYPICAL - REFER TO ELEVATIONS FOR SIZES AND PROFILES 09 WINDOW SILL WITH TRANSOM PANEL BELOW SCALE: TRANSOM WINDOW 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE. - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G. 5/16" HARDIPANEL - SMOOTH FINISH, TYPICAL - HOLD 1/4" OFF BRICK MOULD 1x TRIM, TYPICAL - 30° BEVELED EDGE @ TOP, FRONT EDGE 3/8"30°CAULK, CONTINUOUS, TYPICAL 01 WINDOW HEAD @ FRIEZE BOARD SCALE: APPROVED ANCHORS APPROVED FASTENER @ 3"o.c., TYPICAL @ 3"o.c., TYPICAL HORIZONTAL SIDING STRUCTURAL SHEATHING, TYPICAL 112" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE NOTE: WINDOW NAILING FLANGE MUST HAVE A CONTINUOUS LAP OF 1-1/8" OVER THE SHEATHING, TYPICAL 14" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G 3" = 1'-0" 3" = 1'-0" 3" = 1'-0"3" = 1'-0" 3" = 1'-0" 3" = 1'-0" 3" = 1'-0"3" = 1'-0" HARDBOARD FRIEZE - TRIM TO MATCH WINDOW HEADER HEIGHTS - REFER TO ELEVATIONS FOR SIZES AND PROFILES 112" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 14" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 14" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 112" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 14" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 112" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 112" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 14" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 112" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 14" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 14" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 112" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 112" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 14" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES BREAK MTL DRIP EDGE FLASH'G - NAIL T/ FLASHING TO WALL SHEATHING, TYPICAL - EXTEND FLASH'G 1/2"“ BEYOND OUTSIDE EDGE OF WINDOW CAULK, CONTINUOUS CAULK, CONTINUOUS METAL DRIP - NAIL & TAPE TO SHEATHING - USE 1" ROOFING NAILS @ EA. STUD TALLYNS RIDGEREASON FOR PLOT: PLOT DATE: Job No. Sheet No.INHOMESITE NO. OFFICE REVIEW:MASTER BY: DATE: C DATE: 3940 Olympic Blvd, suite 100 Erlanger, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc.JOB INFO:DATE: PERMIT: SIGN-OFF: CONSTRUCTION:REVISION:REVISION:REVISION:REVISION:HOME TYPE:PLAN:8/10/2018 3:56 PM# TLR010090000 PRATIMA SHRESTHA3285 TAMERLANE PLACESTANTON57-460-STANTON ENGLISH ELEGANCE WITH BRICK & STONE CARMEL, IN9 05/2017 ------------------------------------------------Masterpiece fieldspecchange@fischerhomes.comREVISED BY:----AJIT DHAKALSAPPHIRE TRADE SUPPORT sapphiretradepartners@fischerhomes.com Fischer Homes Indianapolis II, LLC f/k/aFischer Homes Indianapolis II, L.P.D1.2 08/29/18 William Hohlt