Loading...
HomeMy WebLinkAboutA000.2SCALE:FRONT ELEVATION1/4" = 1'-0"- TOP OF FOUNDATION TOP OF FLOOR TOP OF PLATE WINDOW HEAD HGT. WINDOW HEAD HGT. TOP OF PLATE TOP OF FLOOR \A1;8'-6" \A1;HEEL HEIGHT \A1;2'-8{\H0.750000x;\S1#4;}" \A1;R4'-2{\H0.750000x;\S1#2;}" \A1;6'-5" \A1;2'-2" \A1;5'-4{\H0.750000x;\S3#8;}"\A1;R4'-2{\H0.750000x;\S1#2;}" 12121212 1212 1212 SMOOTH PANEL, PER SPEC 6" RAKE BOARD, PER SPEC6" FRIEZE, PER SPEC 8" TRIM, PER SPEC BRICK VENEER, PER SPEC 6" FASCIA BOARD, PER SPEC 10" FRIEZE, PER SPEC ROOF SHINGLES, PER SPEC SOLDIER COURSE, PER SPEC 12121212 2040 FX BLACKED OUT WINDOW \A1;8'-2{\H0.750000x;\S7#8;}" \A1; \A1;8'-1{\H0.750000x;\S1#8;}" \A1; \A1;9'-1{\H0.750000x;\S1#8;}" \A1; \A1;7'-2{\H0.750000x;\S7#8;}" \A1; \A1;5'-0" STONE VENEER, PER SPEC LIMESTONE SILL, PER SPEC SCALE:ROOF PLAN1/8" = 1'-0"- "A"3157ROOF AREA:SQ. FT. 8:12 6:12 \A1;1'-0"\PTYP. 12:1212:12 12:12 12:12 12:12 \A1;24'-6" 12:12 5:12 12:12 \A1;24'-6" 8:12 "C"8ROOF AREA:SQ. FT.MIN. 8 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "C" \A1;2'-0" \A1;2'-0" \A1;24'-0" \A1;8'-0" \A1;12'-0"4:12 4:1212:12 "B"200ROOF AREA:SQ. FT. SCALE:RIGHT ELEVATION1/8" = 1'-0"- 126 128 124 TOP OF FND TOP OF FLOOR TOP OF PLATE TOP OF FLOOR TOP OF PLATEWINDOW HEAD HGT. WINDOW HEAD HGT. 1212 \A1;9'-1{\H0.750000x;\S1#8;}"\A1;\A1;8'-2{\H0.750000x;\S7#8;}" \A1;\A1;8'-1{\H0.750000x;\S1#8;}"\A1;\A1;7'-2{\H0.750000x;\S7#8;}" \A1;SCALE:LEFT ELEVATION1/8" = 1'-0"- TOP OF FND TOP OF FLOOR TOP OF PLATE TOP OF FLOOR TOP OF PLATEWINDOW HEAD HGT. WINDOW HEAD HGT. 126 128 \A1;HORIZONTAL SIDING, PER SPEC ROOF SHINGLES, PER SPEC 4" CORNER BOARD, PER SPEC 1212 \A1;9'-1{\H0.750000x;\S1#8;}"\A1;\A1;8'-2{\H0.750000x;\S7#8;}" \A1;\A1;8'-1{\H0.750000x;\S1#8;}"\A1;\A1;7'-2{\H0.750000x;\S7#8;}" \A1; SCALE:REAR ELEVATION1/8" = 1'-0"- TOP OF FND TOP OF FLOOR TOP OF PLATE TOP OF FLOOR TOP OF PLATEWINDOW HEAD HGT. WINDOW HEAD HGT.1212 12121212 \A1;9'-1{\H0.750000x;\S1#8;}"\A1;\A1;8'-2{\H0.750000x;\S7#8;}" \A1;\A1;8'-1{\H0.750000x;\S1#8;}"\A1;\A1;7'-2{\H0.750000x;\S7#8;}" \A1; ELEVATION EC3W ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3157 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.21 5.26 3.39 46.56 8 0 AT EAVE 6.31 5.26 3.89 53.44 0 56.00 TOTAL (MIN)10.52 10.52 7.28 100.00 3 HIGH - RIDGE VENT 4.21 5.26 3.75 49.09 0 0 30.00 AT EAVE 6.31 5.26 3.89 50.91 0 56.00 TOTAL (MIN)10.52 10.52 7.64 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ROOF AREA "B"SQ FTG 200 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.27 0.33 0.42 46.56 1 0 AT EAVE 0.40 0.33 0.49 53.44 0 7.00 TOTAL (MIN)0.67 0.67 0.91 100.00 3 HIGH - RIDGE VENT 0.27 0.33 0.00 ####0 0 0.00 AT EAVE 0.40 0.33 0.00 ####0 0.00 TOTAL (MIN)0.67 0.67 0.00 ####ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE PLOTTED: August 13, 2018 / Rudolph Sanchez / 2447-BELFORT-MZ-BASE-EL-EC3W.DWG A3-EC3W 3FB.31Euro Country 3W3 Car Front Entry - Grade BrickFront,Side and Rear Elevation, Roof Plan and Ventilation Schedule1900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2018 Suzette Schuette06/13/2016 RIGHT BELFORT 2447.300.00.CPM LOT 26 08/10/2018 08/27/18 William Hohlt