Loading...
HomeMy WebLinkAbouta0038'-712" ATTIC TRUSSES GIRDER TRUSS SCALE: ROOF PLAN ELEVATION "D" 1/4" = 1'-0" PRE-ENGINEERED ROOF TRUSSES AT 24" O.C. VALLEY TRUSS OVERFRAME @ 24" O.C. OPT RAKE EXTENSION NO OVERHANG STD 1'-0"1'-0"ATTIC TRUSSES @ 24' OCPRE-ENGINEERED ROOF TRUSSES AT 24" O.C.D.S.D.S. 8:12 SLOPE 8:12 SLOPE 24" HVAC TRAY CEILING 0-6-15 0-6-15 0-6-150-6-15D.S. SCALE: MORNING ROOM ROOF PLAN 1/4" = 1'-0" GIRDER TRUSS 10:12 SLOPE 10:12 SLOPE 5' RIDGE VENT12"OH12" OH D.S.8:12SLOPE ROOF TRUSSES AT 24" O.C. VALLEY TRUSS OVERFRAME @ 24" O.C. OPT RAKE EXTENSION NO OVERHANG STD 12" OH CATHEDRAL CLG OPT RAKE EXTENSIONNO OVERHANG STD17' RIDGE VENT12' RIDGE VENT12:12 SLOPE 12:12 SLOPE 12:12 SLOPE 12:12 SLOPE 12:12 SLOPE 33' RIDGE VENT 8:12SLOPE8:12SLOPE8:12SLOPE10:12 SLOPE 10:12 SLOPEOPT RAKE EXTENSIONNO OVERHANG STDOPT RAKE EXTENSIONNO OVERHANG STDOPT RAKE EXTENSIONNO OVERHANG STDBEARING WALL BELOW 3 PT. BEARING ROOF TRUSSES AT 24" O.C.VALLEY TRUSS OVERFRAME @ 24" O.C.PRE-ENGINEERED ROOF TRUSSES AT 24" O.C.VALLEY TRUSS OVERFRAME @ 24" O.C. VALLEY TRUSS OVERFRAME @ 24" O.C. 3 PT. BEARING ROOF TRUSSES AT 24" O.C. ROOF TRUSSES AT 24" O.C. ROOF TRUSSES AT 24" O.C.ROOF TRUSSES AT 24" O.C.BEDROOM #2 CATHEDRAL CLG D.S. D.S.D.S. D.S. D.S. 12" OH12"OH12" OH 12"OH12" OH 12" OH 12" OH12"OH12"OHD.S. 12" OH 12" OH VALLEY TRUSSOVERFRAME @24" O.C.VALLEY TRUSSOVERFRAME @24" O.C.12"OH6" OH 6" OH 6"OH OPT MORNING ROOM 1. THIS LAYOUT REPRESENTS DESIGN INTENT ONLY. SUPPLIER IS TO PROVIDE FINAL TRUSS LAYOUT AND ENGINEERED DRAWINGS FOR APPROVAL OF . 2. TRUSS DRAWINGS STAMPED BY AN ENGINEER REGISTERED WITH THE STATE OF PERMIT, ALONG WITH LAYOUT SHEET, TO BE PROVIDED TO THE BUILDING INSPECTOR FOR FRAMING INSPECTION. 3. ALL TRUSS CONNECTIONS TO BE PROVIDED BY THE TRUSS MANUFACTURER. 4. "I"- JOIST RAFTER DESIGN BASED ON LPI 20PLUS (1.5E) I-JOISTS BY LOUISANA PACIFIC U.N.O. 5. ALL ROOF TRUSSES AND RAFTERS ARE TO BE CONNECTED TO DOUBLE TOP PLATE w/ A MINIMUM OF (1) H2.5A BY SIMPSON OR EQUAL U.N.O. 6. GIRDER TRUSSES ARE TO HAVE HOLD DOWNS TO RESIST THE REQUIRED UPLIFT AS SHOWN ON TRUSS MANUFACTUER'S DRAWINGS. 7. ALL DIMENSIONAL LUMBER TO BE SYP #2 OR BETTER UNLESS NOTED OTHERWISE. 12" OVERHANGS 8" AT BRICK12' RIDGE VENTMINIMUM ROOF PITCH TO BE 8 / 12. SEE ELEVATIONS HEEL CUTS TO REFLECT CHANGE. PROVIDE CRICKET. EXTEND PAST BACK OF BONUS WALL MIN 8" MIN 4 / 12 PITCH 3'-0" Sheet: Issued Date: Sheet Title : LSP Date: BASE PLAN REVISION:11x17 PRINTS ARE 12 SCALE LSP By: LSP Rev: 4 5 Job #: Iss Date 04-09-18 05-21-18 06-01-18 07-11-18 Kentmore III6 7 10114 SOLACE LN BONBARMC 8/13/18 BB-3 ----M/I Homes Inc.M/I HOMESPRESTIGE SERIES 2017 © M/I Homes Indianapolis RegionArchitecture Department8425 Woodfield Crossing Blvd.Indianapolis, IN 46240Ph 317.255.99007.0D Roof Plan - Base Roof 08/31/18 Mike Sheeks