HomeMy WebLinkAbout83 SP101 Building SpecificationsG`S ( OF SECTION: 15000 MECHANICAL REQUIREMENTS: A. PLUMBING SCBPE Furnish all Tabor, material, equipment and services necessary to complete nstallation of all waste systems, drainage systems, ventsystems, hot and cold water systems and all plumbing fixtures shown on the drawings and herein specified. Fixtures to be American Standard or equal, SPECIAL REQUIREMENTS 1, ALL WATER LINES INSTALLED TO BE COPPER. 2. ALL WATER LINES TO HAVE SHUT-OFF VALVES IN METER ROOM AND WHERE ENTERING UNITS. 3. RDDF FLASHINGS TO BE BY ROOFING CONTRACTOR CONTRACTOR. CODES AND REGULATIONS Comply with the Indiana Plumbing Code, and the Indiana Energy Conservation Code or the local codes having jurisdiction in the particular area. MATERIALS General All material specified below shall conform to the standards listed in Table 14-1 of the Indiana Plumbing Cade, TRENCHES Plumbing trenches under slabs shall be backflUed with granular material and compacted to 98%. SANITARY SYSTEM Laying Pipe: Establish all flow conditions prior to commencing work In order to avoid conflicts Contractor will be allowed reasonable variations from the established grades and elevation of those shown on the plans In order to meet the final and exact condition. Vents; Fixtures shall be vented as indicated on drawings. Vents and soil stacks Shell be extended through the roof. They shall be terminated 16' above the roof and flashed with an approved flashing by Dura -last Roofing Contractor. Hangers and Supports, Conform to Chapter 3, Section 3.14 of the Indiana Plumbing Code. Covering of Work, No work shall be covered until the required tests have been made and opproval for cover-up ehas been granted by the Inspector, Tests In accordance with Chapter 6, Section 609.4 of the Indlana Plumbing Code, Sterilizatlon of Water Pipings The Contractor shall flush the entire system of all Impurities. Additional disinfecting may be required by the local authority. B. HEATING AND AIR CONDITIONING SCDPE Furnish all labor, material, equipment and services necessary to complete installation of all heating and a conditioning work and all fan duct work shown on the drawings and herein specified, SPECIAL REQUIREMENTS: 1, ALL RTU SIZES AND SPECIFICATIONS LISTED ON THE MECHANICAL PLAN SHEETS, 2. HEATING CONTRACTOR TO FURNISH AND INSTALL ALL REQUIRED GAS LINES. 3. HEATING CONTRACTOR TO FURNISH AND INSTALL ALL INSULATED DROPS 4. UNITS TO BE EQUIPPED WITH SMOKE DETECTORS. CODE CDMPLIANCES Comply with the Indiana Mechanical Code, the Indlana Fuel Gas Code, and the Indiana Energy Conservation Code, or other local code having jurisdiction in the particular area, HEATING EQUIPMENT General All equipment sholl conform to the requirements of the latest edition of the Energy Conservation Code, The minimum efficiency rating of all electric heating and cooling equipment shall meet the requirement of Table 5032.3 (1 thru 7). The contractor shot( verify that the equipment prior to submitting his bid. AIR CONDITIONING EQUIPMENT General All equipment shall conform to the requirements of the latest edition of the Energy Conservation Code, The minimum efficiency rating of all electric heating and caching equipment shall meet the requirement of Table 5032.3 (1 then 7). The contractor shall verify that the equipment prior to submitting his bid. TESTS Each system shall be tested to Insure that the Intent stated above has been realized, Bonnet temperature and equipment noise level shall be checked to Insure proper egdpment operation. Air flow at each register shall be checked to Insure proper and unrestricted air flow through the duct system. All tests required by the Indiana Mechanical Code shall be performed. BACKDRAFT DAMPERS Air discharge openings through roofs orexterior walls sholl be protected r agoinst the entrance of bids, large insoots and foreign objects. Automatic louversor backdraft dampers sholl be provided on other than attic ventilators to prevent a reverse flow of or when the Pan is not In operation. a#y18�1ae11Y9fUR CONTRACTOR TD FURNISH STATE APPROVED DRAWINGS SCOPE Furnish all labor, material, equipment and services ne e ary to complx nstallation of fire protection system as shown on thedrawings and herelr specified, CODE CDMPLIANCES Comply with the Indiana Fire Code, IBC, or other local code hi jurisdiction In the particular area. SPECIAL REQUIREMENTS Flow Indicater to be installed on Sprinkler Systems Riser for connection alarm bell Tests: In accordance with Chapter 9of the Indiana Fire Code and Chapter 9 of the International Building Code. SECTION: 16000 ELECTRICAL REQUIREMENTS: SCOPE Furnish all labor, material, equipment and services necessary to install and connect all electrical equipment shown on the drawings and specified in these specifications. SPECIAL REQUIREMENTS 1. ALL WIRING SHALL TO BE 412 MINIMUM COPPER. 2. ALL ELECTRIC SERVICE INFORMATION TO BE CDDRDINATED WITH LOCAL UTILITY REQUIREMENTS, 3, ALL ELECTRIC PANELS TO BE EQUIPED WITH BUILT IN COPPER BUSS TYPE, 4, ALL CONDUITS TO BE STRAPPED OR CLAMPED ACCORDING TO NEC AND ALL BENDS TO BE MADE WITH APPROVED BENDERS. 5, ALL JUNCTION BOXES ARE TO HAVE COVERS INSTALLED AND CIRCUITS CONTAINED INSIDE TO BE MARKED ON COVER. 6, ALL RECEPTACLES TO BE 18' TO CENTER AFF, UNLESS OTHERWISE NOTED. 7, NO MORE THAN FIVE (5) RECEPTACLES SHALL BE ALLOWED ON ANY ONE (U CIRCUIT, 8, ALL PANELS SHALL HAVE TYPED IDENTIFICATION LABELS FOR ALL CIRCUITS, 9. A SEPERATE GROUND WIRE SHALL BE PULLED IN ALL CONDUIT RUNS AND SHALL BE CONTINUOUS THROUGH SYSTEM. (EMT IS NOT AN ACCEPTABLE GROUND) 10. THERE WILL BE A WATER PIPE GROUND ALONG WITH BUILDING AND POUTER REBAR GRDUND FOR THE SERVICE, 11. ALL WEATHERPROOF COVERS SHALL BE FLUSH, COVERED AND GASKETED WITH CORD USEABLE COVERS TO KEEP OUT ANY MOISTURE, 12. ALL ELECTRICAL CONNECTIONS SHALL BE DONE BY APPROVED METHODS. 13. ALL CONDUITS AND WIRING FUR ELECTRICAL SERVICE TO BE FURNISHED AND INSTALLED PER LOCAL POWER CUMPANYS REQUIREMENTS. 14. TELEPHONE SERVICE CONDUIT TO BE FURNISHED AND INSTALLED BY SITE CONTRACTOR, GENERAL The Instollatlon shall comply with all laws of local regulating authorities, the regulations of the current edition of the Indiana Electric Code and with wiring rules of the local electrical utility company, After completion of work, the Contractor shall furnish the Owner, a certificate of final inspection and approval from the local inspection department or bureau having jurisdiction, MATERIAL Prohibited MatericH The use of aluminum wire Is prohibited, all material shall be new, bearing Underwriter's stamp of approval 19f133uIPFY711'. All work shall be executed in a workmanlike manner and shall present a neat appearance when completed. Markers: Each meter and its associated switch shall be identified by number, Each meter and switch shall have a panel. Sleeves: Passage of conduit through any firewall shall be provided with pipe sleeves, seal space between and conduit with fireproof caulking, PROGRESS OF WORK The Contractor shall order the progress of this work so as to conform to the progress of the work of other trades and shall complete the entire installation as soon as the condition of the building will permit, DESIGN LOADINGS: CONCRETE FLOOR LOADING: 1. All concrete slab Flooring shall be designed forthefollowing loading: Floor Live Load (uniform): 100 psf Floor Live Load (concentrated): 1,000 psf STEEL LOADING: 1. All Steel Framing membershall be designed to r the following loading: Roof Live Load (uniform): 20 psf Roof Live Load (concentrated): 300 psf Roof Snow Load: 20psf= 0.7 Ce Ct I Pg Pg Gound snow Load: 20psf WIND LOADING Basic Wind Speed: 90mph Importance Factor (I): Category II - 1=1.00 Exposure Catagory: B Internal Pressure Coefficent (GCpi): ±0.18 Componants and Cladding: 4.7 & -15.8 SEISMIC DESIGN LOADING Seismic Importance factor: 1=1.0 Occupancy Category: II Mapped Spectral Response Acceleration (Sg & SI) Sg= 0.20g S1= 0.08g Site Class D Smg= 0.32g Sml= 0.19g Bulge 0.21g Shc= 0.13g Seismic Design Category: B Seismic Base Shear: 71.68 kips Seismic Response Coefficient: 0.07 Response Modification factor3 Equivalent Lateral Force Procedure used. REVISION NVERSATILE\ CONSTRUCTION GROUP, LLC. Trudy Rood, Suite 810 570 East T New Whiteland, Indiana 46154 ell: 317.535.3579 Fax: 317.635.3561 email: 1.535.3579 Fax: THIS DRAWINGS THE PROPERTY L VERSATILE CONSTRUCTION GROUP LLC OTHER PURPOSE BETHE ROJECT\�4,Nt DESCRIBED HEREIN \\o\\\wl lYRPLi. A Bqf, /p/ eeth �No FP oma 19700309 of =�q � � A /ry i-. / /L WX'Fs�. EXISTING(B) NEW(A) World Wide Motors 3900 East 96th Street Indianapolis, Indiana a 1, �� 1 O 1 1 1 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and local Codes City Ci of Carmel Job No. 17021 Date Stamped ..xxx.¢(� Drawn By kset Checked By tab Scale:////`AL 1' 0 1J 1lA Specifications Building Specifications CAD FILE: CERTIFIED BY: c\17021\sprat building spedfkationd.g f � DATE: 09/10/18