HomeMy WebLinkAboutA007 - Wall SectionsEXIST. APPROX. 2'-8"EXISTING GRADE
EXISTING FOUNDATION
& BRICK
NEW BAND BOARD
TO MATCH EXISTING
NEW SIDING TO
MATCH EXISTING
1 1/2" FURRING W/ RIGID
FOAM INSULATION EXISTING SLAB
NEW TREATED SILL PLATE
NEW HDWD. FLOORING
NEW DRICORE SUBFLOOR
NEW 2X4 STUD WALL INFILL
W/ R-15 BATT INSULATION
NEW ALUMINUM CLAD
WOOD CASEMENT WINDOW
EXISTING HEADER
EXISTING SOFFIT
EXISTING ROOF FRAMING
NEW 1/2" DRYWALL
EXISTING CEILING
FRAMING
NEW R-30 BATT
INSULATION
NEW 1X4 TONGUE &
V-GROOVE CEILING
2'-8" MIN.NEW BAND BOARD
TO MATCH EXISTING
TREATED SILL PLATE
FINISH GRADE
NEW 8" CONCRETE
FOUNDATION WALL &
CONTINUOUS FOOTER
2" RIGID FOAM INSULATION
PEA GRAVEL BACKFILL OVER 6
MIL VISQUEEN VAPOR BARRIER
2X6 STUD WALL @ 16" O.C.
W/ R-19 BATT INSULATION
2X6 STUD WALL @ 16" O.C.
W/ R-19 BATT INSULATION
NEW SIDING TO MATCH EXISTING
2X8 FLOOR JOISTS @ 16" O.C.
W/ 3/4" T&G OSB SUBFLOOR
NEW HDWD. FLOORING
NEW 1/2" DRYWALL
NEW 1/2" DRYWALL CLG. W/
KNOCKDOWN TEXTURE
2X8 FLOOR JOISTS @ 16" O.C.
W/ 3/4" T&G OSB SUBFLOOR
NEW CARPET & PAD
#1
of
31
Date
:08.21.18
Sheet
:
Revision:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been
prepared by Case Design &
Remodeling solely for its use and
should not be reproduced or relied
upon by any other parties.
Dimensions shown or scaled are
subject to change per actual job
condition and must be verified.
Materials are to be supplied as
specified as equal or standard
when not uniquely specified.
Installed materials may vary in
appearance from drawings.
Reference manufacturer's product
data for actual appearance and
specifications.Ortman ResidenceStair Hall Addition & Attic Guest SuiteTim Ortman13789 Smokey Ridge Dr.Carmel, Indiana 46033Approved By:
Date:
7
FINAL
Jordan Stocklin
Designer
jstocklin@caseindy.com
Dave Null
Lead Designer
dnull@caseindy.com
WALL SECTIONS
SCALE: 1/4" = 1'
SUNROOM
WALL SECTION
BB ADDITION
WALL SECTION
AA
#2 08.29.18
08/30/18
Mike Sheeks