HomeMy WebLinkAboutA008 - 1st Floor ElectricalDN
UP
EP EP
TV
R
R R
RR
SD
R
3
D3
TO STAIRWAY
SCONCES
D3
SUNROOM
STAIR HALL
CLOSET
GARAGEELECTRICAL
PANELS
KITCHEN
RELOCATED
ELECTRIC METER
TO STAIRWAY
CHANDELIER
D3
ELECTRICAL NOTES:ELECTRICALNOTES:
INSTALL ELECTRIC METER AT NEW LOCATION & RECONNECT.
EXISTING FLOOD LIGHTS AT EXTERIOR OF SUNROOM ARE TO REMAIN.
FURNISH & INSTALL (4) 6" LED RECESSED CAN LIGHTS IN SUNROOM ON NEW 3-WAY
DIMMER SWITCH AS SHOWN ON PLANS.
INSTALL (1) HOMEOWNER PROVIDED CEILING FAN IN SUNROOM ON NEW SINGLE
SWITCH AS SHOWN ON PLANS.
F/I (1) 6" WATERPROOF LED RECESSED CAN LIGHT IN SOFFIT OVER SUNROOM
EXTERIOR DOOR ON NEW SINGLE SWITCH AS SHOWN ON PLANS.
F/I (5) NEW DUPLEX RECEPTACLES & (1) NEW RECEPTACLE IN EXISTING LOCATION
IN SUNROOM AS SHOWN ON PLANS.
F/I (1) NEW TV OUTLET IN EXISTING LOCATION IN SUNROOM AS SHOWN ON PLANS.
F/I (1) 6" LED RECESSED CAN LIGHT IN STAIR HALL ON NEW 3-WAY DIMMER SWITCH
W/ SECOND FLOOR LIGHTS AS SHOWN ON PLANS.
F/I (1) BARE BULB FIXTURE W/ LED BULB ON NEW SINGLE SWITCH IN CLOSET UNDER
STAIRS AS SHOWN ON PLANS.
F/I (2) DUPLEX RECEPTACLES IN STAIR HALL AS SHOWN ON PLANS.
F/I (1) NEW INTERCONNECTED SMOKE DETECTOR IN STAIR HALL AS SHOWN ON
PLANS.
TV
R
SD
GFCI
R
LEGEND-ELECTRICAL
LIGHTING
NEW 6" LED CANS
SWITCHES
COMMUNICATION
MISCELLANEOUS
SMOKE DETECTOR
EXISTING SMOKE DETECTORS TO BE HARDWIRE
WITH BATTERY BACKUP; UPDATE PER CODE
ALL WORK TO BE CONFORM TO THE NEC AND
ALL LOCAL APPLICABLE CODES.
EXACT DEVICE LOCATIONS SUBJECT TO JOB
CONDITIONS.
METER LOCATION TO BE DETERMINED BY
LOCAL UTILITY COMPANY.
GENERAL NOTES
OUTLETS
NEW OUTLETS
GFI OUTLET
DIMMER SWITCH (TOGGLE)
SINGLE SWITCH
OUTLET & SWITCH COVER PLATES
TO MATCH EXISTING
NEW WALL MOUNT FIXTURE
NEW WATER PROOF CAN
TERMINATE ANY TELEPHONE
JACKS OR CAT5 OUTLETS UNLESS
OTHERWISE NOTED
NEW EXHAUST
FAN/LIGHT COMBO
D
3 3-WAY SWITCH
NEW CEILING FIXTURE
TV OUTLET
CAT5 OUTLET
#1
of
31
Date
:08.21.18
Sheet
:
Revision:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been
prepared by Case Design &
Remodeling solely for its use and
should not be reproduced or relied
upon by any other parties.
Dimensions shown or scaled are
subject to change per actual job
condition and must be verified.
Materials are to be supplied as
specified as equal or standard
when not uniquely specified.
Installed materials may vary in
appearance from drawings.
Reference manufacturer's product
data for actual appearance and
specifications.Ortman ResidenceStair Hall Addition & Attic Guest SuiteTim Ortman13789 Smokey Ridge Dr.Carmel, Indiana 46033Approved By:
Date:
8
FINAL
Jordan Stocklin
Designer
jstocklin@caseindy.com
Dave Null
Lead Designer
dnull@caseindy.com
1ST FLOOR ELECTRICAL
SCALE: 1/4" = 1'
#2 08.29.18
08/30/18
Mike Sheeks