HomeMy WebLinkAboutA008 - 1st Floor ElectricalDN UP EP EP TV R R R RR SD R 3 D3 TO STAIRWAY SCONCES D3 SUNROOM STAIR HALL CLOSET GARAGEELECTRICAL PANELS KITCHEN RELOCATED ELECTRIC METER TO STAIRWAY CHANDELIER D3 ELECTRICAL NOTES:ELECTRICALNOTES: INSTALL ELECTRIC METER AT NEW LOCATION & RECONNECT. EXISTING FLOOD LIGHTS AT EXTERIOR OF SUNROOM ARE TO REMAIN. FURNISH & INSTALL (4) 6" LED RECESSED CAN LIGHTS IN SUNROOM ON NEW 3-WAY DIMMER SWITCH AS SHOWN ON PLANS. INSTALL (1) HOMEOWNER PROVIDED CEILING FAN IN SUNROOM ON NEW SINGLE SWITCH AS SHOWN ON PLANS. F/I (1) 6" WATERPROOF LED RECESSED CAN LIGHT IN SOFFIT OVER SUNROOM EXTERIOR DOOR ON NEW SINGLE SWITCH AS SHOWN ON PLANS. F/I (5) NEW DUPLEX RECEPTACLES & (1) NEW RECEPTACLE IN EXISTING LOCATION IN SUNROOM AS SHOWN ON PLANS. F/I (1) NEW TV OUTLET IN EXISTING LOCATION IN SUNROOM AS SHOWN ON PLANS. F/I (1) 6" LED RECESSED CAN LIGHT IN STAIR HALL ON NEW 3-WAY DIMMER SWITCH W/ SECOND FLOOR LIGHTS AS SHOWN ON PLANS. F/I (1) BARE BULB FIXTURE W/ LED BULB ON NEW SINGLE SWITCH IN CLOSET UNDER STAIRS AS SHOWN ON PLANS. F/I (2) DUPLEX RECEPTACLES IN STAIR HALL AS SHOWN ON PLANS. F/I (1) NEW INTERCONNECTED SMOKE DETECTOR IN STAIR HALL AS SHOWN ON PLANS. TV R SD GFCI R LEGEND-ELECTRICAL LIGHTING NEW 6" LED CANS SWITCHES COMMUNICATION MISCELLANEOUS SMOKE DETECTOR EXISTING SMOKE DETECTORS TO BE HARDWIRE WITH BATTERY BACKUP; UPDATE PER CODE ALL WORK TO BE CONFORM TO THE NEC AND ALL LOCAL APPLICABLE CODES. EXACT DEVICE LOCATIONS SUBJECT TO JOB CONDITIONS. METER LOCATION TO BE DETERMINED BY LOCAL UTILITY COMPANY. GENERAL NOTES OUTLETS NEW OUTLETS GFI OUTLET DIMMER SWITCH (TOGGLE) SINGLE SWITCH OUTLET & SWITCH COVER PLATES TO MATCH EXISTING NEW WALL MOUNT FIXTURE NEW WATER PROOF CAN TERMINATE ANY TELEPHONE JACKS OR CAT5 OUTLETS UNLESS OTHERWISE NOTED NEW EXHAUST FAN/LIGHT COMBO D 3 3-WAY SWITCH NEW CEILING FIXTURE TV OUTLET CAT5 OUTLET #1 of 31 Date :08.21.18 Sheet : Revision: www.caseindy.com 99 E. Carmel Drive, Suite 100 Carmel, Indiana 46032 317.846.2600 317.846.2601(f) These drawings have been prepared by Case Design & Remodeling solely for its use and should not be reproduced or relied upon by any other parties. Dimensions shown or scaled are subject to change per actual job condition and must be verified. Materials are to be supplied as specified as equal or standard when not uniquely specified. Installed materials may vary in appearance from drawings. Reference manufacturer's product data for actual appearance and specifications.Ortman ResidenceStair Hall Addition & Attic Guest SuiteTim Ortman13789 Smokey Ridge Dr.Carmel, Indiana 46033Approved By: Date: 8 FINAL Jordan Stocklin Designer jstocklin@caseindy.com Dave Null Lead Designer dnull@caseindy.com 1ST FLOOR ELECTRICAL SCALE: 1/4" = 1' #2 08.29.18 08/30/18 Mike Sheeks