HomeMy WebLinkAboutA012 - 2nd Floor ElectricalR
R
R R
GFCI CD CW
R
R R
RR
R
R
C5/TV
GFCIGFCI
SD
SD
R
GFCI
D
3 3
TO FIRST
FLOOR DIMMER
3
USB
EXISTING
MASTER CLOSET
CLOSET
OPEN TO BELOW UPPER
LANDING
HALL
LAUNDRY
BATH
BEDROOM
UNFINISHED
ATTIC
UNFINISHED
ATTIC
3
TO FIRST
FLOOR DIMMER
TV
R
SD
GFCI
R
LEGEND-ELECTRICAL
LIGHTING
NEW 6" LED CANS
SWITCHES
COMMUNICATION
MISCELLANEOUS
SMOKE DETECTOR
EXISTING SMOKE DETECTORS TO BE HARDWIRE
WITH BATTERY BACKUP; UPDATE PER CODE
ALL WORK TO BE CONFORM TO THE NEC AND
ALL LOCAL APPLICABLE CODES.
EXACT DEVICE LOCATIONS SUBJECT TO JOB
CONDITIONS.
METER LOCATION TO BE DETERMINED BY
LOCAL UTILITY COMPANY.
GENERAL NOTES
OUTLETS
NEW OUTLETS
GFI OUTLET
DIMMER SWITCH (TOGGLE)
SINGLE SWITCH
OUTLET & SWITCH COVER PLATES
TO MATCH EXISTING
NEW WALL MOUNT FIXTURE
NEW WATER PROOF CAN
TERMINATE ANY TELEPHONE
JACKS OR CAT5 OUTLETS UNLESS
OTHERWISE NOTED
NEW EXHAUST
FAN/LIGHT COMBO
D
3 3-WAY SWITCH
NEW CEILING FIXTURE
TV OUTLET
CAT5 OUTLET
ELECTRICAL NOTES:
INSTALL (2) HOMEOWNER PROVIDED SCONCE LIGHTS & (1)
HANGING CEILING LIGHT IN STAIR HALL ON NEW 3-WAY DIMMER
SWITCH WITH FIRST FLOOR LIGHT AS SHOWN ON PLANS.
FURNISH & INSTALL (2) DUPLEX RECEPTACLES IN UPPER LANDING
AREA AS SHOWN ON PLANS.
F/I (2) 6" LED RECESSED CAN LIGHTS ON NEW 3-WAY SWITCH IN
HALL AS SHOWN ON PLANS.
F/I (5) DUPLEX RECEPTACLES IN HALL AS SHOWN ON PLANS.
F/I (1) BARE BULB FIXTURE W/ LED BULB ON NEW SINGLE SWITCH IN
EACH OF (2) UNFINISHED ATTIC SPACES AS SHOWN ON PLANS.
F/I (2) 6" LED RECESSED CAN LIGHTS ON NEW SINGLE SWITCH IN
CLOSET AS SHOWN ON PLANS.
(1) EXISTING FLUORESCENT LIGHT & SWITCH TO REMAIN IN
MASTER CLOSET.
F/I (2) 6" LED RECESSED CAN LIGHTS ON NEW SINGLE SWITCH IN
LAUNDRY ROOM AS SHOWN ON PLANS.
F/I (1) GFCI RECEPTACLE ABOVE COUNTERTOP IN LAUNDRY ROOM
AS SHOWN ON PLANS.
F/I (1) DUPLEX RECEPTACLE AT STANDARD HEIGHT IN LAUNDRY
ROOM AS SHOWN ON PLANS.
F/I RECEPTACLES FOR H.O. PROVIDED WASHING MACHINE &
ELECTRIC DRYER IN LAUNDRY ROOM AS SHOWN ON PLANS.
INSTALL (2) HOMEOWNER PROVIDED WALL-MOUNTED VANITY
LIGHTS ON NEW SINGLE SWITCH IN BATHROOM AS SHOWN ON
PLANS.
F/I (1) 6" WATERPROOF LED CAN LIGHT OVER SHOWER ON NEW
SINGLE SWITCH IN BATHROOM AS SHOWN ON PLANS.
F/I (1) EXHAUST FAN/LIGHT COMBO ON NEW SINGLE SWITCH IN
BATHROOM AS SHOWN ON PLANS.
F/I (2) GFCI RECEPTACLES AT VANITY IN BATHROOM AS SHOWN ON
PLANS.
F/I (5) 6" LED RECESSED CAN LIGHTS ON NEW DIMMER SWITCH IN
BEDROOM AS SHOWN ON PLANS.
INSTALL (1) HOMEOWNER PROVIDED CEILING FAN ON NEW SINGLE
SWITCH IN BEDROOM AS SHOWN ON PLANS.
F/I (1) INTERCONNECTED SMOKE DETECTOR IN BEDROOM AS
SHOWN ON PLANS.
F/I (5) DUPLEX RECEPTACLES IN BEDROOM AS SHOWN ON PLANS.
F/I (1) DUPLEX RECEPTACLE W/ INTEGRATED USB OUTLETS IN
SHELVING NICHE IN BEDROOM AS SHOWN ON PLANS.
F/I (1) CAT5/TV OUTLET IN BEDROOM AS SHOWN ON PLANS. VERIFY
LOCATION PRIOR TO INSTALLATION.
#1
of
31
Date
:08.21.18
Sheet
:
Revision:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been
prepared by Case Design &
Remodeling solely for its use and
should not be reproduced or relied
upon by any other parties.
Dimensions shown or scaled are
subject to change per actual job
condition and must be verified.
Materials are to be supplied as
specified as equal or standard
when not uniquely specified.
Installed materials may vary in
appearance from drawings.
Reference manufacturer's product
data for actual appearance and
specifications.Ortman ResidenceStair Hall Addition & Attic Guest SuiteTim Ortman13789 Smokey Ridge Dr.Carmel, Indiana 46033Approved By:
Date:
12
FINAL
Jordan Stocklin
Designer
jstocklin@caseindy.com
Dave Null
Lead Designer
dnull@caseindy.com
2ND FLOOR ELECTRICAL
SCALE: 1/4" = 1'
#2 08.29.18
08/30/18
Mike Sheeks