Loading...
HomeMy WebLinkAboutTRUSSRe: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Timberland Home Center-Brazil, IN. Galinski, John ST. MICHAELS C Pages or sheets covered by this seal: I28368878 thru I28368914 My license renewal date for the state of Indiana is July 31, 2018. 1600718 Truss Engineer’s responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. IMPORTANT NOTE: 16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. November 23,2016 Job 1600718 Truss A Truss Type COMMON Qty 10 Ply 1 ST. MICHAELS C Job Reference (optional) I28368878 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:29:49 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-4dtaD1Qy65weiDi2iIN?I_IiueqUZmgk3nRUz2yGaAW Scale = 1:73.8 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 3x6 5x6 3x6 5x6 4x6 3x4 2x4 3x4 3x8 3x4 3x4 4x6 3x8 3x6 3x6 9-6-10 9-6-10 19-8-8 10-1-14 28-3-14 8-7-6 38-0-0 9-8-2 -0-11-4 0-11-4 6-8-3 6-8-3 13-2-6 6-6-3 19-8-8 6-6-3 25-8-8 6-0-0 31-8-8 6-0-0 38-0-0 6-3-8 0-6-612-0-61-4-57.00 12 Plate Offsets (X,Y)-- [2:0-1-0,0-0-9], [2:0-6-0,0-1-3] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.80 0.97 0.71 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.22 -0.60 0.13 (loc) 11-12 14-16 11 l/defl >999 >753 n/a L/d 240 180 n/a PLATES MT20 Weight: 171 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-16,9-12,10-11,9-11: 2x4 SPF Stud/No.3 WEDGE Left: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 2-16. WEBS 1 Row at midpt 5-14, 7-14, 9-11 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=1574/0-3-8, 11=1507/Mechanical Max Horz 2=20(LC 6) Max Uplift 2=-120(LC 6), 11=-85(LC 6) Max Grav 2=1694(LC 12), 11=1655(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2684/182, 3-5=-2499/209, 5-6=-1740/230, 6-7=-1734/232, 7-9=-2185/204, 9-10=-360/79, 10-11=-337/74 BOT CHORD 2-16=-85/2196, 14-16=-1/1742, 12-14=0/1613, 11-12=-61/1795 WEBS 3-16=-365/148, 5-16=0/572, 5-14=-773/155, 6-14=-121/1276, 7-14=-615/137, 7-12=0/347, 9-11=-2010/103 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11 except (jt=lb) 2=120. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss A1G Truss Type GABLE Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368879 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:29:51 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-0??LejSDejAMxXrRqjPTNPOD7Sjr1pC1X4wb1wyGaAU Scale = 1:73.2 Sheet Back Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 12 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 63 3x6 5x6 3x6 3x8 3x6 5x6 38-0-0 38-0-0 -0-11-4 0-11-4 19-8-8 19-8-8 38-0-0 18-3-8 0-6-612-0-61-4-57.00 12 Plate Offsets (X,Y)-- [2:0-0-9,0-1-0], [2:0-1-3,0-6-0], [2:0-3-8,Edge], [44:0-0-0,0-1-12], [45:0-2-8,0-0-4], [45:0-1-12,0-0-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.11 0.08 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 1 1 33 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 289 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 *Except* 17-48,16-49,15-50,14-51,13-52,18-47,19-46,20-45,21-43: 2x4 SPF No.2 WEDGE Left: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 17-48, 16-49, 15-50, 14-51, 13-52, 18-47, 19-46, 20-45, 21-43 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 38-0-0. (lb) - Max Horz 2=20(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 33, 2, 50, 51, 52, 54, 55, 56, 57, 58, 59, 60, 61, 62, 46, 45, 43, 42, 41, 40, 39, 38, 37, 36, 35 except 48=-117(LC 7), 34=-123(LC 6) Max Grav All reactions 250 lb or less at joint(s) 33, 2, 48, 49, 50, 51, 52, 54, 55, 56, 57, 58, 59, 60, 61, 62, 47, 46, 45, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 15-16=-230/267, 16-17=-235/275, 17-18=-235/275, 18-19=-230/267 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 33, 2, 50, 51, 52, 54, 55, 56, 57, 58, 59, 60, 61, 62, 46, 45, 43, 42, 41, 40, 39, 38, 37, 36, 35 except (jt=lb) 48=117, 34=123. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss AG Truss Type GABLE Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368880 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:29:52 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-UBYjr2TrP0IDZhQdNRxivcwBvstHm69Amkg8aNyGaAT Scale = 1:73.8 Sheet Front Right Option 1-1-1 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 11 36 37 12 3x6 5x6 5x6 4x6 3x4 3x4 3x8 3x4 3x4 4x6 4x6 3x6 3x6 5x6 3x6 9-6-10 9-6-10 19-8-8 10-1-14 28-3-14 8-7-6 36-0-0 7-8-2 36-10-15 0-10-15 38-0-0 1-1-1 -0-11-4 0-11-4 6-8-3 6-8-3 13-2-6 6-6-3 18-0-0 4-9-10 19-8-8 1-8-8 25-8-8 6-0-0 31-8-8 6-0-0 38-0-0 6-3-8 0-6-612-0-61-4-57.00 12 Plate Offsets (X,Y)-- [2:0-1-0,0-0-9], [2:0-6-0,0-1-3], [8:0-3-0,0-3-0], [9:0-0-9,0-2-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.94 0.83 0.73 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.54 0.12 (loc) 15-17 15-17 11 l/defl >999 >787 n/a L/d 240 180 n/a PLATES MT20 Weight: 221 lb FT = 0% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF-S 1650F 1.6E *Except* 14-16: 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-17,9-13,10-11,9-11: 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 *Except* 18-19: 2x4 SPF No.2 WEDGE Left: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-15, 7-15, 9-11 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=1566/0-3-8, 11=1362/2-3-8, 12=153/0-3-8 Max Horz 2=20(LC 6) Max Uplift 2=-124(LC 6), 11=-156(LC 6) Max Grav 2=1686(LC 12), 11=1505(LC 12), 12=280(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2667/189, 3-5=-2483/217, 5-6=-1726/237, 6-7=-1719/239, 7-9=-2134/227, 9-10=-266/129, 10-11=-289/99 BOT CHORD 2-17=-91/2181, 15-17=-8/1729, 13-15=0/1583, 12-13=-84/1748, 11-12=-84/1748 WEBS 3-17=-364/147, 5-17=0/570, 5-15=-773/155, 6-15=-129/1261, 7-15=-585/151, 7-13=-12/271, 9-11=-2053/78 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=124, 11=156. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss B Truss Type COMMON Qty 5 Ply 1 ST. MICHAELS C Job Reference (optional) I28368881 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:29:53 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-yO653OUTAKQ4Bq?px8SxSqTQDFDSVgJK_OPi6pyGaAS Scale = 1:68.4 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 17 183x6 5x6 3x6 5x6 3x6 3x8 3x4 3x4 2x4 3x4 3x4 2x4 5x6 3x6 9-1-0 9-1-0 18-0-0 8-11-0 26-11-0 8-11-0 36-0-0 9-1-0 -0-11-4 0-11-4 6-1-6 6-1-6 12-0-11 5-11-5 18-0-0 5-11-5 23-11-5 5-11-5 29-10-10 5-11-5 36-0-0 6-1-6 36-11-4 0-11-4 0-6-611-0-60-6-67.00 12 Plate Offsets (X,Y)-- [2:0-1-0,0-0-9], [2:0-6-0,0-1-3], [10:0-1-0,0-0-9], [10:0-6-0,0-1-3] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.65 0.84 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.50 0.13 (loc) 10-12 10-12 10 l/defl >999 >857 n/a L/d 240 180 n/a PLATES MT20 Weight: 153 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 *Except* 6-14,7-14,5-14: 2x4 SPF No.2 WEDGE Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-14, 5-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=1493/0-3-8, 10=1493/0-3-8 Max Uplift 2=-115(LC 6), 10=-115(LC 6) Max Grav 2=1606(LC 12), 10=1606(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2533/174, 3-5=-2346/191, 5-6=-1694/214, 6-7=-1694/214, 7-9=-2346/191, 9-10=-2533/174 BOT CHORD 2-16=-64/2074, 14-16=0/1681, 12-14=0/1681, 10-12=-64/2074 WEBS 6-14=-110/1255, 7-14=-702/138, 7-12=0/490, 9-12=-326/134, 5-14=-702/138, 5-16=0/490, 3-16=-326/134 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=115, 10=115. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss BG Truss Type GABLE Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368882 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:29:54 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-QagTGkU5xeYxo_a0VrzA?10jyfleEAETD29FeFyGaAR Scale = 1:68.4 Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 2223 24 25 26 27 28 29 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 55 563x6 5x6 3x6 3x8 3x6 3x8 3x6 36-0-0 36-0-0 -0-11-4 0-11-4 18-0-0 18-0-0 36-0-0 18-0-0 36-11-4 0-11-4 0-6-611-0-60-6-67.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [2:0-1-3,0-6-0], [2:0-0-9,0-1-0], [9:0-1-10,Edge], [21:0-1-10,Edge], [28:0-0-9,0-1-0], [28:0-1-3,0-6-0], [28:0-3-8,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.14 0.07 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.01 0.01 (loc) 29 29 28 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 250 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 *Except* 15-42,14-43,13-44,12-45,16-41,17-40,18-39: 2x4 SPF No.2 WEDGE Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 15-42, 14-43, 13-44, 12-45, 16-41, 17-40, 18-39 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 36-0-0. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 42, 44, 45, 46, 48, 49, 50, 51, 52, 53, 54, 40, 39, 38, 36, 35, 34, 33, 32, 31, 30 Max Grav All reactions 250 lb or less at joint(s) 2, 42, 43, 44, 45, 46, 48, 49, 50, 51, 52, 53, 41, 40, 39, 38, 36, 35, 34, 33, 32, 31, 28 except 54=319(LC 12), 30=319(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 42, 44, 45, 46, 48, 49, 50, 51, 52, 53, 54, 40, 39, 38, 36, 35, 34, 33, 32, 31, 30. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss C Truss Type COMMON Qty 4 Ply 1 ST. MICHAELS C Job Reference (optional) I28368883 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:29:55 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-vmEsU4VjixgoQ89C3ZUPXFYs23wIzZpcSiupAiyGaAQ Scale = 1:65.2 1 2 3 4 5 6 7 8 9 10 11 12 3x4 4x6 3x4 3x8 3x4 3x4 5x9 2x4 2x4 3x8 3x4 3x4 10-0-0 10-0-0 20-0-0 10-0-0 -0-11-4 0-11-4 5-1-12 5-1-12 10-0-0 4-10-4 14-10-4 4-10-4 20-0-0 5-1-12 20-11-4 0-11-4 0-9-010-9-00-9-012.00 12 Plate Offsets (X,Y)-- [2:0-4-1,Edge], [10:0-4-1,Edge], [12:0-4-8,0-3-4] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.31 0.81 0.35 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.50 0.02 (loc) 2-12 10-12 10 l/defl >999 >485 n/a L/d 240 180 n/a PLATES MT20 Weight: 94 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 *Except* 6-12: 2x4 SPF No.2 SLIDER Left 2x4 SPF Stud/No.3 3-7-3, Right 2x4 SPF Stud/No.3 3-7-3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=856/0-3-8, 10=856/0-3-8 Max Uplift 2=-75(LC 4), 10=-75(LC 4) Max Grav 2=911(LC 8), 10=911(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-956/107, 4-6=-807/157, 6-8=-807/157, 8-10=-956/107 BOT CHORD 2-12=0/580, 10-12=0/580 WEBS 6-12=-122/700, 8-12=-317/172, 4-12=-317/172 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss C1 Truss Type COMMON Qty 2 Ply 1 ST. MICHAELS C Job Reference (optional) I28368884 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:29:55 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-vmEsU4VjixgoQ89C3ZUPXFYsy3wBzZocSiupAiyGaAQ Scale = 1:65.2 1 2 3 4 5 6 7 8 9 10 11 3x4 4x6 3x4 3x8 3x4 3x4 5x9 2x4 2x4 3x8 3x4 3x4 10-0-0 10-0-0 20-0-0 10-0-0 5-1-12 5-1-12 10-0-0 4-10-4 14-10-4 4-10-4 20-0-0 5-1-12 20-11-4 0-11-4 0-9-010-9-00-9-012.00 12 Plate Offsets (X,Y)-- [1:0-4-1,Edge], [9:0-4-1,Edge], [11:0-4-8,0-3-4] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.31 0.82 0.35 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.20 -0.51 0.02 (loc) 1-11 1-11 9 l/defl >999 >471 n/a L/d 240 180 n/a PLATES MT20 Weight: 93 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 *Except* 5-11: 2x4 SPF No.2 SLIDER Left 2x4 SPF Stud/No.3 3-7-3, Right 2x4 SPF Stud/No.3 3-7-3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=799/0-3-8, 9=858/0-3-8 Max Horz 1=-23(LC 4) Max Uplift 1=-44(LC 4), 9=-76(LC 4) Max Grav 1=877(LC 8), 9=912(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-957/109, 3-5=-808/159, 5-7=-808/159, 7-9=-957/108 BOT CHORD 1-11=0/581, 9-11=0/580 WEBS 5-11=-125/702, 7-11=-317/173, 3-11=-319/176 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss CG Truss Type GABLE Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368885 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:29:56 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-NzoEhQWLTFof2IkOcG?e4S52bTRPi2QmgMeMj8yGaAP Scale = 1:68.0 Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 36 39 37 40 38 41 3x8 3x4 4x6 3x4 3x8 3x4 20-0-0 20-0-0 -0-11-4 0-11-4 10-0-0 10-0-0 20-0-0 10-0-0 20-11-4 0-11-4 0-9-010-9-00-9-012.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-1-12], [18:0-4-4,0-1-8], [35:0-0-0,0-1-12], [35:0-4-0,0-1-4] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.19 0.12 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 -0.00 0.00 (loc) 19 18 20 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 147 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 *Except* 9-28,11-26: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 36, 37, 38, 39, 40 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 20-0-0. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 35, 20, 30, 31, 32, 33, 25, 24, 23, 22 except 34=-121(LC 4), 21=-121(LC 4) Max Grav All reactions 250 lb or less at joint(s) 35, 20, 28, 30, 31, 32, 33, 34, 26, 25, 24, 23, 22, 21, 27 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 35, 20, 30, 31, 32, 33, 25, 24, 23, 22 except (jt=lb) 34=121, 21=121. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss CGR Truss Type COMMON Qty 1 Ply 2 ST. MICHAELS C Job Reference (optional) I28368886 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:29:57 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-r9McvmX_EZwWfSJaA_Wtcge8lsdRRSOvv0NvFayGaAO Scale = 1:67.9 1 2 3 4 5 6 7 8 12 11 10 91314151617 18 19 3x4 4x6 3x4 3x6 4x6 4x9 3x6 2x4 3x6 3x10 3x10 5-4-4 5-4-4 10-3-8 4-11-4 15-2-12 4-11-4 20-3-8 5-0-12 5-4-4 5-4-4 10-3-8 4-11-4 15-2-12 4-11-4 20-3-8 5-0-12 21-2-12 0-11-4 0-5-810-9-00-9-012.00 12 Plate Offsets (X,Y)-- [1:0-3-8,0-1-8], [7:0-0-12,0-0-12], [7:0-1-7,0-3-13], [7:0-5-8,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.55 0.64 0.41 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.13 0.03 (loc) 10-12 10-12 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 220 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF Stud/No.3 *Except* 4-10: 2x4 SPF No.2 WEDGE Right: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=3860/0-3-8, 7=3518/0-3-8 Max Horz 1=-27(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3974/0, 2-4=-2663/108, 4-6=-2662/106, 6-7=-3936/0 BOT CHORD 1-12=0/2716, 10-12=0/2716, 9-10=0/2610, 7-9=0/2610 WEBS 4-10=-55/3334, 6-10=-1201/108, 6-9=0/1599, 2-10=-1350/112, 2-12=0/1650 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 4) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 576 lb down at 0-1-12, 563 lb down at 2-4-4, 563 lb down at 4-4-4, 563 lb down at 6-4-4, 563 lb down at 8-4-4, 563 lb down at 10-4-4, 563 lb down at 12-4-4, 563 lb down at 14-4-4, and 563 lb down at 16-4-4, and 563 lb down at 18-4-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-8=-60, 1-7=-20 Continued on page 2 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss CGR Truss Type COMMON Qty 1 Ply 2 ST. MICHAELS C Job Reference (optional) I28368886 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:29:57 2016 Page 2 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-r9McvmX_EZwWfSJaA_Wtcge8lsdRRSOvv0NvFayGaAO LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 1=-576(B) 11=-563(B) 10=-563(B) 7=-67 13=-563(B) 14=-563(B) 15=-563(B) 16=-563(B) 17=-563(B) 18=-563(B) 19=-563(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 1600718 Truss DG Truss Type GABLE Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368887 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:29:57 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-r9McvmX_EZwWfSJaA_WtcgeEBsndRT_vv0NvFayGaAO Scale = 1:44.6 Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 4x6 12-4-8 12-4-8 -0-11-4 0-11-4 6-2-4 6-2-4 12-4-8 6-2-4 13-3-12 0-11-4 1-9-07-11-41-9-012.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-R 0.14 0.06 0.37 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 0.00 (loc) 13 12 14 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 86 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 12-4-8. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15 except 19=-129(LC 5) Max Grav All reactions 250 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15 except 19=332(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-169/265, 7-8=-169/265 WEBS 7-19=-317/155 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15 except (jt=lb) 19=129. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss DGR Truss Type COMMON Qty 1 Ply 2 ST. MICHAELS C Job Reference (optional) I28368888 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:29:58 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-JLw_66Xc?s2NHcunkh169tAP_G12ApJ38g7Tn0yGaAN Scale = 1:48.7 1 2 3 4 5 6 11 10 9 8 712131415 4x12 4x6 2x8 2x8 6x6 3x6 10x10 3x6 6x6 4x12 0-4-8 0-4-8 3-2-14 2-10-6 6-2-4 2-11-6 9-1-10 2-11-6 12-4-8 3-2-14 3-2-14 3-2-14 6-2-4 2-11-6 9-1-10 2-11-6 12-4-8 3-2-14 13-3-12 0-11-4 1-9-07-11-41-9-012.00 12 Plate Offsets (X,Y)-- [8:0-3-0,0-4-4], [10:0-3-0,0-4-4] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.14 0.43 0.81 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.07 0.01 (loc) 9-10 9-10 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 192 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP No.1 WEBS 2x4 SPF Stud/No.3 *Except* 1-11,5-7: 2x8 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)11=5554/0-3-8, 7=4419/0-3-8 Max Horz 11=-56(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3440/0, 2-3=-2801/31, 3-4=-2799/30, 4-5=-3427/0, 1-11=-3689/0, 5-7=-3717/0 BOT CHORD 9-10=0/2378, 8-9=0/2360, 7-8=0/258 WEBS 1-10=0/2493, 2-10=0/939, 2-9=-772/66, 3-9=0/3683, 4-9=-738/71, 4-8=0/913, 5-8=0/2400 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 4) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1494 lb down at 0-3-10, 1487 lb down at 2-5-4, 1487 lb down at 4-5-4, 1487 lb down at 6-5-4, 1487 lb down at 8-5-4, and 1487 lb down at 10-5-4, and 25 lb down and 64 lb up at 12-0-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 5-6=-60, 7-11=-20 Concentrated Loads (lb) Vert: 11=-1494(B) 7=-25 9=-1487(B) 12=-1487(B) 13=-1487(B) 14=-1487(B) 15=-1487(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss EG Truss Type GABLE Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368889 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:29:58 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-JLw_66Xc?s2NHcunkh169tANfG5BA_m38g7Tn0yGaAN Scale = 1:18.1 Sheet Back Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 5 4 6 2x4 2x4 2x4 2x4 2x4 5-11-8 5-11-8 0-5-62-11-35.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.29 0.16 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=148/5-11-8, 4=-96/5-11-8, 5=412/5-11-8 Max Horz 1=36(LC 6) Max Uplift 1=-21(LC 6), 4=-112(LC 11), 5=-150(LC 6) Max Grav 1=155(LC 11), 4=51(LC 6), 5=435(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-331/212 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 4=112, 5=150. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss F Truss Type MONO TRUSS Qty 5 Ply 1 ST. MICHAELS C Job Reference (optional) I28368890 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:29:59 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-nYUMJSYEmAAEvlSzIPZLh5jUmgP_vSGCNKs0KTyGaAM Scale = 1:18.9 1 2 3 4 2x4 2x4 2x4 5-11-8 5-11-8 5-11-8 5-11-8 0-5-62-11-35.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.52 0.32 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.14 0.00 (loc) 1-3 1-3 3 l/defl >999 >487 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=219/0-11-4, 3=219/0-3-8 Max Horz 1=36(LC 6) Max Uplift 1=-48(LC 6), 3=-65(LC 6) Max Grav 1=230(LC 11), 3=232(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss FG Truss Type GABLE Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368891 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:29:59 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-nYUMJSYEmAAEvlSzIPZLh5jZTgRwvSGCNKs0KTyGaAM Scale = 1:12.6 Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 2x4 2x4 2x4 3-7-8 3-7-8 0-5-61-11-85.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.22 0.13 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=139/3-7-8, 3=139/3-7-8 Max Horz 1=23(LC 6) Max Uplift 1=-32(LC 6), 3=-43(LC 6) Max Grav 1=147(LC 11), 3=141(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss G Truss Type SPECIAL Qty 9 Ply 1 ST. MICHAELS C Job Reference (optional) I28368892 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:00 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-Fk1lXoZsXUI4Wv19r64aEIGan4g7emnMb_casvyGaAL Scale = 1:83.1 1 2 3 4 5 6 7 8 9 10 19 18 17 16 15 14 13 12 11 20 21 22 23 24 4x9 7x10 MT18HS 5x6 4x9 3x4 3x6 4x6 2x4 3x6 3x6 3x6 3x4 4x9 4x6 6x12 3x6 5x9 5x6 7-7-5 7-7-5 14-11-2 7-3-13 22-4-1 7-4-15 26-0-0 3-7-15 26-0-8 0-0-8 33-11-4 7-10-12 42-0-0 8-0-12 -0-11-4 0-11-4 7-7-5 7-7-5 14-11-2 7-3-13 22-4-1 7-4-15 26-0-8 3-8-7 33-11-4 7-10-12 42-0-0 8-0-12 2-3-811-0-012-0-00-6-61-0-012-0-07.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [4:0-4-8,Edge], [5:0-6-8,0-2-0], [6:0-3-8,0-2-8], [8:0-4-8,Edge], [10:0-1-0,0-0-9], [10:0-6-0,0-1-3], [14:0-8-8,0-4-4] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.89 0.58 0.62 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.10 -0.27 0.04 (loc) 11-13 10-11 10 l/defl >999 >705 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 217 lb FT = 0% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-6: 2x4 SP 2400F 2.0E, 1-4,8-10: 2x4 SPF-S 1650F 1.6E BOT CHORD 2x4 SPF No.2 *Except* 14-17: 2x4 SPF-S 1650F 1.6E WEBS 2x4 SPF No.2 *Except* 3-18,11-14,9-11,2-19,2-18: 2x4 SPF Stud/No.3 WEDGE Right: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-9 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 14-15. WEBS 1 Row at midpt 7-13, 3-16, 5-15, 6-15, 9-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)19=1046/0-3-8, 14=1835/0-3-8, 10=528/Mechanical Max Horz 19=41(LC 7) Max Uplift 19=-92(LC 6), 14=-124(LC 6), 10=-27(LC 6) Max Grav 19=1350(LC 18), 14=2410(LC 18), 10=613(LC 26) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1473/125, 3-5=-993/175, 5-6=-379/162, 6-7=-446/169, 7-9=0/475, 9-10=-732/56, 2-19=-1280/130 BOT CHORD 16-18=0/1163, 15-16=0/660, 14-15=-344/162, 10-11=0/565 WEBS 7-14=-1865/126, 3-16=-711/117, 5-16=0/614, 5-15=-830/45, 6-15=-300/9, 7-15=0/1004, 11-14=0/568, 9-14=-974/138, 9-11=0/338, 2-18=0/1070 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 10 except (jt=lb) 14=124. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss G1 Truss Type GABLE Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368893 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:01 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-jwb7k7aUInQx83cMPqbpnWolnU0LNDaVqeL7OLyGaAK Scale = 1:78.0 Sheet Front Left Option 6-0-0 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 23 22 21 20 18 17 16 15 14 13 12 11 33 34 35 36 37 19 4x9 7x10 MT18HS 5x6 4x9 3x4 3x6 4x6 3x6 3x6 3x4 3x4 4x9 4x6 6x12 3x6 5x9 5x6 5-8-8 5-8-8 6-0-0 0-3-8 7-7-5 1-7-5 14-11-2 7-3-13 22-4-1 7-4-15 26-0-0 3-7-15 26-0-8 0-0-8 33-11-4 7-10-12 42-0-0 8-0-12 -0-11-4 0-11-4 6-0-0 6-0-0 7-7-5 1-7-5 14-11-2 7-3-13 22-4-1 7-4-15 26-0-8 3-8-7 33-11-4 7-10-12 42-0-0 8-0-12 2-3-811-0-012-0-00-6-61-0-012-0-07.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [4:0-4-8,Edge], [5:0-6-8,0-2-0], [6:0-3-8,0-2-8], [8:0-4-8,Edge], [10:0-1-0,0-0-9], [10:0-6-0,0-1-3], [14:0-8-8,0-4-4], [28:0-1-10,0-1-0], [30:0-1-10,0-1-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.87 0.58 0.59 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.10 -0.27 0.03 (loc) 11-13 10-11 10 l/defl >999 >705 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 236 lb FT = 0% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-6: 2x4 SP 2400F 2.0E, 1-4,8-10: 2x4 SPF-S 1650F 1.6E BOT CHORD 2x4 SPF No.2 *Except* 14-17: 2x4 SPF-S 1650F 1.6E WEBS 2x4 SPF No.2 *Except* 3-18,11-14,9-11,2-23,2-18: 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 WEDGE Right: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-5 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 14-15. WEBS 1 Row at midpt 7-13, 3-16, 5-15, 6-15, 9-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 6-0-0 except (jt=length) 14=0-3-8, 10=Mechanical, 19=0-3-8. (lb) - Max Horz 23=41(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 10, 20, 22, 19 except 23=-139(LC 6), 14=-126(LC 6) Max Grav All reactions 250 lb or less at joint(s) 20, 21, 22, 19 except 23=1238(LC 18), 14=2360(LC 18), 10=618(LC 26) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1325/135, 3-5=-955/176, 5-6=-373/163, 6-7=-438/170, 7-9=0/462, 9-10=-743/56, 2-23=-1173/135 BOT CHORD 16-18=0/1035, 15-16=0/628, 14-15=-333/162, 10-11=0/575 WEBS 7-14=-1812/128, 3-18=-267/76, 3-16=-590/126, 5-16=0/557, 5-15=-784/47, 6-15=-304/8, 7-15=0/958, 11-14=0/577, 9-14=-973/138, 9-11=0/337, 2-18=0/950 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are MT20 plates unless otherwise indicated. 8) All plates are 2x4 MT20 unless otherwise indicated. 9) Gable studs spaced at 1-4-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) Refer to girder(s) for truss to truss connections. Continued on page 2 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss G1 Truss Type GABLE Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368893 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:02 2016 Page 2 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-B79VyTa625YomDBYzX62JjLwWtMa6gqe3I5gwoyGaAJ NOTES- 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 20, 22, 19 except (jt=lb) 23=139, 14=126. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 1600718 Truss GG Truss Type GABLE Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368894 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:05 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-cireaVd?L0xNdgw7efflxMzbJ5VJJ8p5lGJKX6yGaAG Scale = 1:76.3 Sheet Back Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 4746 45 44 43 42 41 40 39 38 37 70 3x6 3x6 3x6 3x6 5x6 5x6 3x8 26-0-8 26-0-8 42-0-0 15-11-8 -0-11-4 0-11-4 14-11-2 14-11-2 22-4-1 7-4-15 26-0-8 3-8-7 42-0-0 15-11-8 2-3-812-0-01-0-00-6-61-0-012-0-07.00 12 Plate Offsets (X,Y)-- [15:0-3-0,0-1-12], [21:0-3-0,0-1-12], [36:0-3-8,Edge], [36:0-1-3,0-6-0], [36:0-0-9,0-1-0], [45:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.13 0.07 0.19 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 -0.01 (loc) 1 1 36 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 343 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 *Except* 21-51,20-52,19-53,18-54,17-55,16-56,14-57,13-58,12-60,22-50,23-49,25-46: 2x4 SPF No.2 WEDGE Right: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 15-21. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: 47-48. 1 Row at midpt 24-48 WEBS 1 Row at midpt 21-51, 20-52, 19-53, 18-54, 17-55, 16-56, 14-57, 13-58, 12-60, 22-50, 23-49, 25-46 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 42-0-0. (lb) - Max Horz 69=41(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 69, 47, 51, 53, 54, 55, 58, 60, 61, 62, 63, 64, 65, 66, 67, 68, 50, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 48 Max Grav All reactions 250 lb or less at joint(s) 69, 47, 51, 52, 53, 54, 55, 56, 57, 58, 60, 61, 62, 63, 64, 65, 66, 67, 68, 50, 49, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 48 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 10-12=-190/253, 12-13=-213/280, 13-14=-238/310, 14-15=-218/280, 15-16=-214/281, 16-17=-214/281, 17-18=-214/281, 18-19=-214/281, 19-20=-214/281, 20-21=-214/282, 21-22=-239/311, 22-23=-224/293, 23-24=-200/265 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 2x4 MT20 unless otherwise indicated. 8) Gable requires continuous bottom chord bearing. 9) Gable studs spaced at 1-4-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) Bearing at joint(s) 48 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. Continued on page 2 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss GG Truss Type GABLE Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368894 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:05 2016 Page 2 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-cireaVd?L0xNdgw7efflxMzbJ5VJJ8p5lGJKX6yGaAG NOTES- 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 69, 47, 51, 53, 54, 55, 58, 60, 61, 62, 63, 64, 65, 66, 67, 68, 50, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 48. 13) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 69, 51, 52, 53, 54, 55, 56, 57, 58, 60, 61, 62, 63, 64, 65, 66, 67, 68, 50, 49. 14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 1600718 Truss PB1 Truss Type SPECIAL Qty 10 Ply 1 ST. MICHAELS C Job Reference (optional) I28368895 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:05 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-cireaVd?L0xNdgw7efflxMzbG5VHJAF5lGJKX6yGaAG Scale = 1:15.0 1 2 3 4 5 6 7 8 4x6 2x4 2x4 2x4 7-4-15 7-4-15 3-8-7 3-8-7 7-4-15 3-8-7 0-4-52-0-50-1-100-4-50-1-107.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.13 0.07 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.01 0.00 (loc) 5 5 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 18 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=153/5-8-10, 4=153/5-8-10, 6=211/5-8-10 Max Uplift 2=-50(LC 6), 4=-50(LC 6) Max Grav 2=157(LC 12), 4=157(LC 12), 6=231(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss PB2 Truss Type SPECIAL Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368896 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:06 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-4uP0ored6K3EEqVJCNB_UZWmiVrP2dVE_w3u3ZyGaAF Scale = 1:15.0 Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 4x6 2x4 2x4 2x4 7-4-15 7-4-15 3-8-7 3-8-7 7-4-15 3-8-7 0-4-52-0-50-1-100-4-50-1-107.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.15 0.08 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.01 0.00 (loc) 5 5 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 18 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=153/5-8-10, 4=153/5-8-10, 6=211/5-8-10 Max Uplift 2=-50(LC 6), 4=-50(LC 6) Max Grav 2=157(LC 12), 4=157(LC 12), 6=231(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V1 Truss Type GABLE Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368897 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:06 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-4uP0ored6K3EEqVJCNB_UZWigVqw2d0E_w3u3ZyGaAF Scale = 1:16.6 Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 2x4 4x6 2x4 2x4 10-6-0 10-6-0 5-3-0 5-3-0 10-6-0 5-3-0 2-2-45.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.41 0.17 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=159/10-6-0, 3=159/10-6-0, 4=406/10-6-0 Max Uplift 1=-38(LC 6), 3=-38(LC 6), 4=-57(LC 6) Max Grav 1=162(LC 8), 3=162(LC 9), 4=406(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-271/107 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V2 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368898 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:11 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-RrCvrYhmxshXLcNH?wm9BdDdDWS5jtEz7CmflmyGaAA Scale: 1"=1’ 1 2 3 2x4 3x4 2x4 6-6-0 6-6-0 3-3-0 3-3-0 6-6-0 3-3-0 1-4-45.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.17 0.49 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=202/6-6-0, 3=202/6-6-0 Max Uplift 1=-50(LC 6), 3=-50(LC 6) Max Grav 1=206(LC 11), 3=206(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 50 lb uplift at joint 1 and 50 lb uplift at joint 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V4 Truss Type GABLE Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368899 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:12 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-v2mH2uiOi9pOylyTYdIOjqlpkvvGSIA7MsWCHCyGaA9 Scale = 1:67.8 Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 35 38 36 39 37 40 4x6 4x6 4x6 3x4 5x6 3x4 22-6-10 22-6-10 11-3-5 11-3-5 22-6-10 11-3-5 11-3-512.00 12 Plate Offsets (X,Y)-- [5:0-2-8,0-0-0], [6:0-2-4,0-2-4], [6:0-0-0,0-1-12], [14:0-2-4,0-2-4], [14:0-0-0,0-1-12], [15:0-2-8,0-0-0], [29:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.12 0.05 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.01 (loc) - - 19 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 160 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 *Except* 9-28,8-29,11-26,12-25: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-29, 12-25 JOINTS 1 Brace at Jt(s): 35, 36, 37, 38, 39 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 22-6-10. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 29, 30, 31, 32, 33, 34, 25, 24, 23, 22, 21, 20 except 1=-104(LC 5), 19=-103(LC 5) Max Grav All reactions 250 lb or less at joint(s) 1, 28, 29, 30, 31, 19, 32, 33, 34, 26, 25, 24, 23, 22, 21, 20, 27 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-268/215, 18-19=-267/214 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 29, 30, 31, 32, 33, 34, 25, 24, 23, 22, 21, 20 except (jt=lb) 1=104, 19=103. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V5 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368900 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:12 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-v2mH2uiOi9pOylyTYdIOjqlnSvtHSHX7MsWCHCyGaA9 Scale = 1:62.1 1 2 3 4 5 6 7 12 11 10 9 83x4 4x6 3x4 5x6 20-2-10 20-2-10 10-1-5 10-1-5 20-2-10 10-1-5 10-1-512.00 12 Plate Offsets (X,Y)-- [11:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.20 0.17 0.25 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 82 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-11: 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 *Except* 4-10: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 20-2-10. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 1, 7 except 11=-142(LC 4), 12=-107(LC 4), 9=-146(LC 4), 8=-108(LC 4) Max Grav All reactions 250 lb or less at joint(s) 1, 7, 10 except 11=449(LC 7), 12=350(LC 7), 9=456(LC 7), 8=348(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-366/192, 2-12=-281/149, 5-9=-373/195, 6-8=-282/149 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7 except (jt=lb) 11=142, 12=107, 9=146, 8=108. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V6 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368901 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:12 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-v2mH2uiOi9pOylyTYdIOjqlm?vs5SIV7MsWCHCyGaA9 Scale = 1:57.5 1 2 3 4 5 9 8 7 63x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 17-10-10 17-10-10 8-11-5 8-11-5 17-10-10 8-11-5 8-11-512.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.29 0.25 0.19 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 68 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 *Except* 3-8: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-8 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 17-10-10. (lb) - Max Uplift All uplift 100 lb or less at joint(s) except 9=-174(LC 4), 6=-174(LC 4) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 8 except 9=546(LC 7), 6=546(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-429/222, 4-6=-430/222 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 9 and 174 lb uplift at joint 6. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V7 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368902 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:13 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-NEKfGEj0TTxEavXf6LpdG2Iy6JDdBlNGbWFmpfyGaA8 Scale = 1:50.9 1 2 3 4 5 9 87 63x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 15-6-10 15-6-10 7-9-5 7-9-5 15-6-10 7-9-5 7-9-512.00 12 Plate Offsets (X,Y)-- [8:0-1-11,0-1-8] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.21 0.17 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 57 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 15-6-10. (lb) - Max Uplift All uplift 100 lb or less at joint(s) except 9=-151(LC 4), 6=-151(LC 4) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 9=459(LC 7), 6=459(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-368/194, 4-6=-368/194 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 151 lb uplift at joint 9 and 151 lb uplift at joint 6. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V8 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368903 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:13 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-NEKfGEj0TTxEavXf6LpdG2IzfJEeBm0GbWFmpfyGaA8 Scale = 1:41.4 1 2 3 4 5 8 7 63x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 13-2-10 13-2-10 6-7-5 6-7-5 13-2-10 6-7-5 6-7-512.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.17 0.10 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 47 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 13-2-10. (lb) - Max Uplift All uplift 100 lb or less at joint(s) except 8=-137(LC 4), 6=-137(LC 4) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=397(LC 7), 6=397(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-327/178, 4-6=-327/178 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 137 lb uplift at joint 8 and 137 lb uplift at joint 6. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V9 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368904 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:14 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-rQu1TakeEn35C36sg2KsoFr1IjY_wD7Pp9?JL5yGaA7 Scale = 1:34.5 1 2 3 43x4 4x6 3x4 2x4 10-10-10 10-10-10 5-5-5 5-5-5 10-10-10 5-5-5 5-5-512.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.63 0.22 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 34 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=227/10-10-10, 3=227/10-10-10, 4=361/10-10-10 Max Uplift 1=-36(LC 4), 3=-36(LC 4) Max Grav 1=254(LC 7), 3=254(LC 7), 4=392(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 36 lb uplift at joint 1 and 36 lb uplift at joint 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V10 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368905 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:07 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-Y4yO?BeFtdB5s_4Vm4iD0n2rvuAnn4NNCaoRc?yGaAE Scale = 1:28.3 1 2 3 42x4 4x6 2x4 2x4 8-6-10 8-6-10 4-3-5 4-3-5 8-6-10 4-3-5 4-3-512.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.57 0.13 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 27 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=189/8-6-10, 3=189/8-6-10, 4=251/8-6-10 Max Uplift 1=-43(LC 4), 3=-43(LC 4) Max Grav 1=218(LC 7), 3=218(LC 7), 4=262(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V11 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368906 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:07 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-Y4yO?BeFtdB5s_4Vm4iD0n2veuB1n4pNCaoRc?yGaAE Scale = 1:21.3 1 2 3 42x4 4x6 2x4 2x4 6-2-10 6-2-10 3-1-5 3-1-5 6-2-10 3-1-5 3-1-512.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.27 0.12 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=132/6-2-10, 3=132/6-2-10, 4=178/6-2-10 Max Uplift 1=-34(LC 4), 3=-34(LC 4) Max Grav 1=154(LC 7), 3=154(LC 7), 4=185(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V12 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368907 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:08 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-0GWmCXftexJyU8fiJoDSZ_b7JIWGWXVXREY?8RyGaAD Scale = 1:12.5 1 2 3 2x4 3x4 2x4 3-10-10 3-10-10 1-11-5 1-11-5 3-10-10 1-11-5 1-11-512.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.08 0.18 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=127/3-10-10, 3=127/3-10-10 Max Uplift 1=-15(LC 4), 3=-15(LC 4) Max Grav 1=142(LC 7), 3=142(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V13 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368908 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:08 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-0GWmCXftexJyU8fiJoDSZ_b40IVAWVWXREY?8RyGaAD Scale = 1:57.5 1 2 3 4 5 9 8 7 63x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 17-10-8 17-10-8 8-11-4 8-11-4 17-10-8 8-11-4 8-11-412.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.29 0.25 0.19 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 68 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 *Except* 3-8: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-8 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 17-10-8. (lb) - Max Uplift All uplift 100 lb or less at joint(s) except 9=-173(LC 4), 6=-173(LC 4) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 8 except 9=545(LC 7), 6=545(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-429/222, 4-6=-430/222 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 173 lb uplift at joint 9 and 173 lb uplift at joint 6. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V14 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368909 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:08 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-0GWmCXftexJyU8fiJoDSZ_b5NIWSWV8XREY?8RyGaAD Scale = 1:50.9 1 2 3 4 5 9 87 63x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 15-6-8 15-6-8 7-9-4 7-9-4 15-6-8 7-9-4 7-9-412.00 12 Plate Offsets (X,Y)-- [8:0-1-12,0-1-8] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.21 0.17 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 57 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 15-6-8. (lb) - Max Uplift All uplift 100 lb or less at joint(s) except 9=-151(LC 4), 6=-151(LC 4) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 9=459(LC 7), 6=459(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-368/194, 4-6=-368/194 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 151 lb uplift at joint 9 and 151 lb uplift at joint 6. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V15 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368910 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:09 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-UT48QtgVPERp5IDutVkh5C7HfitiFz1gguHYguyGaAC Scale = 1:41.4 1 2 3 4 5 8 7 63x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 13-2-8 13-2-8 6-7-4 6-7-4 13-2-8 6-7-4 6-7-412.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.17 0.10 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 47 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 13-2-8. (lb) - Max Uplift All uplift 100 lb or less at joint(s) except 8=-137(LC 4), 6=-137(LC 4) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=397(LC 7), 6=397(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-327/178, 4-6=-327/178 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 137 lb uplift at joint 8 and 137 lb uplift at joint 6. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V16 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368911 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:09 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-UT48QtgVPERp5IDutVkh5C7AZirqFzugguHYguyGaAC Scale = 1:34.5 1 2 3 43x4 4x6 3x4 2x4 10-10-8 10-10-8 5-5-4 5-5-4 10-10-8 5-5-4 5-5-412.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.63 0.22 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 34 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=226/10-10-8, 3=226/10-10-8, 4=361/10-10-8 Max Uplift 1=-36(LC 4), 3=-36(LC 4) Max Grav 1=254(LC 7), 3=254(LC 7), 4=392(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 36 lb uplift at joint 1 and 36 lb uplift at joint 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V17 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368912 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:10 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-yfeXdCh8AYZgjSo4RCFwePgMA6BU_Q7qvY15CKyGaAB Scale = 1:28.3 1 2 3 42x4 4x6 2x4 2x4 8-6-8 8-6-8 4-3-4 4-3-4 8-6-8 4-3-4 4-3-412.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.57 0.13 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 27 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=188/8-6-8, 3=188/8-6-8, 4=250/8-6-8 Max Uplift 1=-43(LC 4), 3=-43(LC 4) Max Grav 1=217(LC 7), 3=217(LC 7), 4=262(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 43 lb uplift at joint 1 and 43 lb uplift at joint 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V18 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368913 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:10 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-yfeXdCh8AYZgjSo4RCFwePgQv6Ck_QZqvY15CKyGaAB Scale = 1:21.3 1 2 3 42x4 4x6 2x4 2x4 6-2-8 6-2-8 3-1-4 3-1-4 6-2-8 3-1-4 3-1-412.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.27 0.12 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=132/6-2-8, 3=132/6-2-8, 4=177/6-2-8 Max Uplift 1=-34(LC 4), 3=-34(LC 4) Max Grav 1=153(LC 7), 3=153(LC 7), 4=185(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 34 lb uplift at joint 1 and 34 lb uplift at joint 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 Job 1600718 Truss V19 Truss Type VALLEY Qty 1 Ply 1 ST. MICHAELS C Job Reference (optional) I28368914 8.030 s Sep 29 2016 MiTek Industries, Inc. Tue Nov 22 16:30:10 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:oe7nxAYeNQAdQBsU4RCgkFzXfeC-yfeXdCh8AYZgjSo4RCFwePgTp6Bm_Q?qvY15CKyGaAB Scale = 1:12.5 1 2 3 2x4 3x4 2x4 3-10-8 3-10-8 1-11-4 1-11-4 3-10-8 1-11-4 1-11-412.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.08 0.18 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=127/3-10-8, 3=127/3-10-8 Max Uplift 1=-15(LC 4), 3=-15(LC 4) Max Grav 1=142(LC 7), 3=142(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 15 lb uplift at joint 1 and 15 lb uplift at joint 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 23,2016 edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)' 2012 MiTekfi All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015WEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.