HomeMy WebLinkAboutA000.7EC2MROOF AREA "A"SQ FTG2172AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY2.903.623.8149.9590AT EAVE4.343.623.8250.05055.00TOTAL (MIN)7.247.247.63100.003 HIGH -RIDGE VENT2.903.623.6348.690029.00AT EAVE4.343.623.8251.31055.00TOTAL (MIN)7.247.247.44100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEEC2MROOF AREA "B"SQ FTG276AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.370.460.4243.2610AT EAVE0.550.460.5656.7408.00TOTAL (MIN)0.920.920.98100.003 HIGH -RIDGE VENT0.370.460.5047.37004.00AT EAVE0.550.460.5652.6308.00TOTAL (MIN)0.920.921.06100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEEC2MROOF AREA "C"SQ FTG156AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.210.260.4246.5610AT EAVE0.310.260.4953.4407.00TOTAL (MIN)0.520.520.91100.003 HIGH -RIDGE VENT0.210.260.3843.55003.00AT EAVE0.310.260.4956.4507.00TOTAL (MIN)0.520.520.86100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE12:12
12:12
12:12
10.5:12
10.5:12
12:12
12:12
12:12
12:12
12:12
12:12
12:12
12:12
4:12
12:12
12:12
12:12
12:12
12:12
"A"
2172
ROOF AREA:
SQ. FT.
"B"
276
ROOF AREA:
SQ. FT.
"C"
156
ROOF AREA:
SQ. FT.
PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION
MIN. 64 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "E"
MIN. 162 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D"
4:12
4:12
4:12
MIN. 208 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF
\A1;1'-0"\PTYP.
\A1;4'-0"
\A1;20'-0"\A1;5'-0"
\A1;4'-0"
\A1;3'-0"
3.5:12
8:12
A4.01 ROOF PLANMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc.
PRODUCT MANAGER----VERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPESingle Family
SHEET
PLAN NAME
SPECIFICATION LEVEL
NPC CHILD NUMBER
----
Truman
1702.300Home for * Market Home *, 5782-115003320 Shelborne Woods Parkway, Carmel, IN 46032ROOF PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER)
09/10/18
William Hohlt