45'-2" CENTER TO CENTER OF WALLS (LEASE DIM) GENERAL CONSTRUCTION NOTES: 1. ALL WORK SHALL BE GOVERNED BY THE LATEST ADOPTED FEDERAL, STATE AND LOCAL CODES, REGULATIONS AND STANDARDS. THEY SHALL GOVERN THE CHARACTER, QUALITY, STYLE, TYPE AND CAPACITY OF ALL INSTALLATIONS, MATERIALS AND EQUIPMENT USED, 2. ALL STATE AND LOCAL AGENCY APPROVALS AND PERMITS SHALL BE OBTAINED PRIOR TO CONSTRUCTION. 3. GENERAL CONTRACTOR IS TO VERIFY ALL EXISTING FIELD CONDITIONS, DIMENSIONS, EQUIPMENT, ITEMS PROVIDED BY THE OWNER AND LOCATION OF ALL UTILITIES TO THE SPACE PRIOR TO CONSTRUCTION. VERIFY THE SIZE AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL WORK, ELECTRICAL WORK AND EQUIPMENT WITH SUBCONTRACTORS INVOLVED. IF DISCREPANCIES EXIST, NOTIFY THE ARCHITECT. 4. GENERAL CONTRACTOR SHALL COORDINATE ALL PHASES AND TIMING OF CONSTRUCTION WITH ARCHITECT, TENANT AND BUILDING OWNER. 5. GENERAL CONTRACTOR IS TO ASSUME RESPONSIBILITY FOR THE COMPLETE FINISH AND BUILD -OUT OF THE PROJECT. ALL SURFACES AND EQUIPMENT EFFECTED BY THE NEW CONSTRUCTION OR MOVEMENT OR REMOVAL OF EXISTING OUTLETS, FIXTURES, WALLS, EQUIPMENT, ETC. SHALL BE REPAIRED TO MATCH SURROUNDING SURFACES. 6. IT IS THE INTENT OF THE DRAWINGS THAT ALL EXPOSED SURFACES SHALL RECEIVE FINISHES AS INDICATED ON THE DRAWINGS OR IN THE SPECIFICATIONS UNLESS OTHERWISE NOTED. IF A SURFACE IS NOT NOTED TO EITHER REMAIN UNFINISHED, EXISTING FINISH TO REMAIN OR TO RECEIVE A SPECIFIC FINISH, NOTIFY THE ARCHITECT. 7. ALL NEW WALL CONSTRUCTION SHALL BE 3-5/8" 26 GA. METAL STUDS AT 16" O.C. WITH 5/8" GYPSUM BOARD APPLIED TO EACH SIDE. PARTITIONS SHALL EXTEND FLOOR TO 12" ABOVE CEILING HEIGHT EXCEPT AS NOTED. DEMISING PARTITIONS BETWEEN TENANTS SHALL EXTEND FLOOR TO STRUCTURAL OR FIRE RATED FLOOR OR ROOF MEMBRANE ABOVE WITH 5/8" TYPE 'X' GYPSUM BOARD APPLIED TO EACH SIDE, SEALED TO MEMBRANE ABOVE. ALL NEW WALL DIMENSIONS SHOWN ARE TO FACE OF STUD FRAMING UNLESS OTHERWISE NOTED. ALIGN NEW WALLS WITH EXISTING WALLS, COLUMNS OR SURFACES AS REQUIRED. IF THERE ARE QUESTIONS OF DESIGN INTENT, NOTIFY THE ARCHITECT FOR CLARIFICATION. SCHEDULE EXISTING ALUMINUM ENTRY DOOR 3'-0" x 7'-0" FULL TEMPERED GLASS LITE, SOLID CORE WOOD, FLUSH PANEL BIRCH VENEER DOOR, STAIN FINISH, PAINTED METAL FRAME, LOCKSET HARDWARE 3'-6" x 7'-0" SOLID CORE WOOD, FLUSH PANEL BIRCH VENEER DOOR, STAIN FINISH, PAINTED METAL FRAME, PRIVACY HARDWARE SET 3'-0" x 7'-0" SOLID CORE WOOD, FLUSH PANEL BIRCH VENEER DOOR, STAIN FINISH, PAINTED METAL FRAME, PASSAGE HARDWARE SET 3'-0" x 7'-0" SOLID CORE WOOD, FLUSH PANEL BIRCH VENEER DOOR, STAIN FINISH, PAINTED METAL FRAME, PRIVACY HARDWARE SET 3'-0" x 7'-0" SOLID CORE WOOD, FLUSH PANEL BIRCH VENEER DOOR, STAIN FINISH, PAINTED METAL FRAME, LOCKSET HARDWARE SET 3'-6" x 7'-0" SOLID CORE WOOD, FLUSH PANEL BIRCH VENEER DOOR, STAIN FINISH, PAINTED METAL FRAME, PASSAGE HARDWARE SET PAIR 2'-6" x 7'-0" BI -FOLD WOOD, FLUSH PANEL BIRCH VENEER DOOR, STAIN FINISH, PAINTED METAL FRAME, PULL KNOBS EXISTING H.M. DOOR AND FRAME, MASTER KEYED LOCKSET MISCELLANEOUS ROOM EQUIPMENT TOILET ROOMS #103, 113 ** SINGLE ROLL TOILET TISSUE DISPENSER, STAINLESS STEEL, WALL HUNG. ** 24" X 36" POLISHED PLATE GLASS WALL HUNG MIRROR. ** BRUSHED CHROME 'C' FOLD PAPER TOWEL DISPENSER, WALL HUNG. ** H.C. WHITE CHINA WALL HUNG LAV., SINGLE LEVER FAUCET ** H.C. WHITE CHINA TOILET. ** 30" & 42" BRUSHED CHROME STAINLESS GRAB BARS ® 33" A.F. EXAM ROOMS #102, 105, 109 & 110 ** STAINLESS STEEL BAR SINK WITH GOOSENECK FAUCET AND DOUBLE BLADE CHROME HANDLES. ** BRUSHED CHROME 'C' FOLD PAPER TOWEL DISPENSER, WALL HUNG. NURSE #106 ** STAINLESS STEEL 21"x24" SINK WITH GOOSENECK FAUCET AND DOUBLE BLADE CHROME HANDLES, EMERGENCY EYEWASH STATION ** BRUSHED CHROME 'C' FOLD PAPER TOWEL DISPENSER, WALL HUNG. STE�GT�c p FQ'k c - -2m �lcou1, .ti RELEASEornPt.,. `pith+ s Sublact to p6 L� t:' � 1 afi stake C���U�s � �,�Towc DEPT 4F MEL � cu \'( OF GAS° �n►DIA ` 0 0 2 �- _ t Mpg,L; o... E� 8 �a,_R Q ._ 1 O Z L7 z w W Lli w • U U z J Q cn z W (~--- Cis W W C) rl �z z w n'; © D J W 0 ME EL � U DC7 00 _ 1 CN cV O c:) CIC g � L z o C:) � LA-; a � M C)OO d , Q a o!f 0) co W om n-, _ L ... _..p. FIXTURE SCHEDULE 2' X 4' (4) LAMP FLUORESCENT RECESSED TROUFFER, 120V METALUX OR EQUAL W,' ACRYLIC PRISMATIC LENSE "P" INDICATES 1 f 2"x 1 %2" PARAWEDGE CHROME LENSE ® RECESSED 75W INCANDESCENT "CAN" LIGHT HALO OR EQUAL ® EXHAUST FAN, NUTONE OR EQUAL. EXIT LIGHT WITH BATTERY E DIRECTIONAL EMERGENCY EXIT LIGHT WITH BATTERY 15A, SINGLE POLE SWITCH t3 15A, 3 -WAY SWITCH tR SLIDE CONTROL RHEOSTAT SWITCH, SIZED FOR LOAD 2' X 4' (4) LAMP OR 2' X 2' FLUORESCENT RECESSED TROUFFER, 120V METALUX OR EQUAL. HALF OF LAMPS ALWAYS ILLUMINATED (NIGHT LICH PROGRESS #P3520-30 WHITE UTILITY LIGHT OR EQUAL L WALL MOUNTED 75W INCANDESCENT DECORATIVE �J SCONCE FIXTURE (SEE INTERIOR DETAILS FOR TYPE) LAY -IN RECESSED AIR DIFFUSERS AND RETURN AIR GRILLES SEE H.V.A.C. PLAN y G � y C � C y o y L5 O C F-. O C -.y. n y (n w p .L N «� d ✓� t ci = -- 3 � �y u z W W z W U V z W �z o cry O O c4 CCr) O o W n n___C1.. n z r z — Lli CY_ D C� [rLm W o ME � Q c� 00 00 lq-- r-- Q z I N O N O O O O Q ZE '-nLLJ z U O LLJ %!7 LLJ � v ♦♦ ri a Z2 cr Z vs rn � n r: .� r r C'7 00 E HVAC GENERAL NOTES 1. WORK SHALL BE DONE IN STRICT ACCORDANCE WITH ALL LOCAL, COUNTY AND STATE CODES AND ALL APPLICABLE LAWS, RULES AND REGULATIONS COVERING THE INSTALLATION OF HEATING, VENTILATING AND AIR-CONDITIONING SYSTEMS. 2. THE MECHNICAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES AND INSPECTION FEES AS REQUIRED FOR THE INSTALLATION OF THE HVAC SYSTEMS. 3. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ORDERING EQUIPMENT WITH THE PROPER VOLTAGES TO MATCH EXISTING ELECTRICAL SERVICE AVAILABLE. 4. AIR HANDLING UNITS SHALL BE HUNG IN THE ATTIC. CONTRACTOR SHALL PROVIDE ALL ANGLES, RODS AND BEAMS TO SUSPEND UNITS FROM THE STRUCTURAL MEMBERS. PROVIDE AND SUPPORT SERVICE PLATFORM ON SIDE OF A.H. UNITS, PROVIDE VIBRATION ISOLATORS FOR A.H. UNITS. 5. INSULATE ALL GALVANIZED DUCTWORK WITH 1" INTERNAL LINER, 6. DUCTWORK RUNNING THROUGH ATTIC SHALL BE DOUBLE INSULATED. 7. SQUARE CEILING DIFFUSERS SHALL BE 24" X 24" PANEL TYPE, ROUND NECK AND BAKED ENAMEL FINISH. DIFFUSERS SHALL FIT 2' X 4' LAY -IN CEILING, COLOR TO MATCH CEILING SYSTEM. 8. RETURN AIR GRILLES SHALL BE EGG -CRATE 112" X 112" X 112" LOUVER TYPE. GRILLES SHALL LAY -IN 24" X 48" "T" BAR TYPE CEILING GRID, UNLESS OTHERWISE NOTED. 9. FURNISH ALL DIFFUSERS WITH OPPOSED BLADE VOLUME DAMPERS OPPERABLE FROM THE FACE OF DIFFUSER. 10. IN "SUPPLY" SHEET METAL DUCTWORK, PROVIDE TURNING VANES IN ALL SQUARE ELBOWS AND EXTRACTORS IN ALL BRANCH TAKE -OFFS. 11. FLUE INSTALLATION SHALL COMPLY WITH N.F.P.A. #9B AS WELL AS STATE AND LOCAL CODES. 12. PROVIDE VOLUME DAMPER AT EACH BRANCH DUCT. 13. CONNECT DIFFUSER TO SHEET METAL DUCT WITH ROUND FLEXIBLE DUCT. FLEXIBLE DUCT IS 5'-0" MAXIMUM LENGTH. NOTE: THIS PLAN IS A SCHEMATIC LAYOUT OF A SUGGESTED SYSTEM FOR THIS TENANT SPACE. IT IS THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO PROVIDE A FINAL DESIGN OF ALL UNITS, DUCT SIZES AND DUCT LAYOUTS WITH WARRANTEES AS REQUIRED BY THE BUILDING OWNER. r�j CD 0 cv m 0 0 v 4 L L" U H.V.A.C. PLAN [K'lf f� worimtol A V�) L t Im Z W U U Q W C7 G~L� cn W U-)r)W C W cr C] CL C p D Z Fy W CL: > W M U W f -- Q D �a. Q� W W f -- Q D PLUMBING GENERAL NOTES: 1. WORK SHALL BE DONE IN STRICT ACCORDANCE WITH ALL LOCAL, COUNTY AND STATE CODES AND ALL APPLICABLE LAWS, RULES AND REGULATIONS COVERING THE INSTALLATION OF PLUMBING SYSTEMS. 2. ALL HOT AND COLD WATER PIPING SHALL BE TYPE "L" HARD COPPER WITH COPPER OR WROUGHT BRASS FITTINGS. 3. ALL WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC. 4. REFRIGERATE PIPING SHALL BE TYPE "L" HARD COPPER WITH SILVER SOLDERED JOINTS. 5. THE PLUMBING CONTRACTOR SHALL VERIFY WITH THE LOCAL GAS COMPANY THE LOCATION OF GAS SERVICE AND SHALL PROVIDE A COMPLETE NEW GAS SERVICE TO EACH OFFICE SUITE. 6. ALL GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE. 7. ALL SANITARY DRAIN LINES SHALL SLOPE A MINIMUMOF 1/8" PER FOOT INSIDE BUILDING. 8. INSTALL PDI RATED SHOCK ABSORBERS IN COLD WATER SYSTEM WHERE REQUIRED. ALL WATER SUPPLY PIPING TO FIXTURES SHALL BE VALVED TO ISOLATE FIXTURES FROM REMAINDER OF SYSTEM. 9. PIPE INSULATION SHALL BE 1/2' THICK FOAMED ELASTOMERIC OR 1" THICK FIBERGLAS WITH VAPOR BARRIER. ALL INSULATION AND JACKETS SHALL NOT EXCEED A FLAME SPREAD OF 25 OR SMOKE DEVELOPED OF 150. INSULATION WILL BE REQUIRED AROUND ALL PVC PIPING IN RETURN AIR PLENUMS AS REQUIRED BY CODES. O z� L RJ Qu z Cu 0 cu 0 0 0 0 cn w _i H li O O Q Ca Cn W J H Li h-- cr Q Q IlLitsIMBING PLAN ll . - L r,� 'til► ELECTRICAL SCHEDULE CONVENIENCE OUTLET 20 AMP, 3 WIRE, 120 V DUPLEX RECEPTACLE NEMA 5-15R � Ff CONVENIENCE OUTLET 20 AMP, 3 WIRE, 120 V DUPLEX RECEPTACLE NEMA 5-15R WITH GROUND FAULT PROTECTION �p CONVENIENCE OUTLET 20 AMP, 3 WIRE, 120 V DUPLEX RECEPTACLE NEMA 5-15R DEDICATED CIRCUIT CONVENIENCE OUTLET 20 AMP, 3 WIRE, 120 V GA FOURPLEX RECEPTACLE NEMA 5-15R WITH GROUND FAULT PROTECTION CONVENIENCE OUTLET 20 AMP, 3 WIRE, 120 V FOURPLEX RECEPTACLE NEMA 5-15R Q ELEC. JUNCTION BOX FOR DIRECT CONNECTION OF EQUIPMENT VERIFY EQUIPMENT REQUIREMENTS b TELEPHONE BOX AND RISER, SIMPLEX b wm TELEPHONE BOX AND RISER, WALL MOUNT, SIMPLEX ELECTRICAL PANEL BOARD, LPA ELECTRICAL NOTES CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO INITIATING WORK. 2. CONTRACTOR TO COORDINATE WORK WITH ALL OTHER TRADES, 3. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL STATE AND LOCAL BUILDING CODES AND PER 1990 NEC. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECTS AS REQUIRED BY ALL NATIONAL, AND LOCAL CODES. 5. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL SERVICE WITH LOCAL POWER COMPANY, 6. ELECTRICAL CONTRACTOR SHALL PERFORM ALL WORK IN STRICT COMPLIANCE WITH NATIONAL ELECTRICAL CODES AND LOCAL CODES. 7. ELECTRICAL CONTRACTOR SHALL NOT PROVIDE OR USE ROMAX WIRE UNLESS APPROVED BY ARCHITECT AND BUILDING OWNER. 8. ELECTRICAL CONTRACTOR SHALL NOT EXCEED EIGHT (8) DUPLEX OUTLET PER CIRCUIT. 9. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL ELECTRICAL AND TELEPHONE OUTLETS ® 15" A.F.F. TO CENTER LINE, UNLESS SPECIFED OTHERWISE ON DRAWING. Cu 0 C) CU CD v 0 N 0 L tD C O Q� 3 CL L 0 0 oo) 0 O L cu Z G L cu 11 200A, 120/208V, 3 PH, 4 WIRE ELEC. PANEL ELECTRICAL PLAN W E- JYA PLAN 0 1 A•I�' !F Q ` 4 ':� o z O N O � N 'o o O .3 0 E O ,v � c O a � -0 O U yU on c H- O C 4r 'A L n'.:'� O C (n 'C O 3 U t C rte- n.Oc.� O O Q ` z � z a � Z Q N N O O Z O � o <c W L VU c.� O W VU ckf ~ U Z ch� Q f W U o crl U 0 c„ z Q W Or4 I— �w (f) o O Or, z -mac Q Z � a LLJ mE � Q U 00 00 Q ` z z N N O O O O � o <c ME L z c.� O w ch� Q f 0- o crl 0