HomeMy WebLinkAbout1ARCHITECT: CSO 600 96TH STREET, SUITE 550 INDIAAPOLIS, INDIANA 46240 13171 8 .7800 13171 574.1869 FAX CONTRACTOR: 6W. REALTY CORPORATION. 600 E. 96th STREET SUITE 100 INDIANAPOLIS, IN 46240 PHONE: (317)808-6000 INDEX: OF DRAWIh "^S • MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH COVER 12 • 5A201 CONSTRUCTION PLAN � 5A202 REFLECTED CEILING &ELECTRICAL PLAN • 12.1 5A801 FINISH &ELEVATIONS PLAN • SM -5 HVAC PLAN KEYPLAN SCALE: NTS STATE FARM INSURANCE SIX PARKWOOD SPECIFICATIONS AND GENERAL NOTES 0 CONTRACT CONDITIONS 0.1 THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION, ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED AS FOLLOWS: ? 3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE PROCEEDING WITH CONSTRUCTION. 3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND WORKMANSHIP. 10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE , CONTRACTOR'S RESPONSIBILITY, 0.2 WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, RULES AND REGULATIONS. 0.3 ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. 0.4 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE SPECIFIED CAPACITIES OF THE EQUIPMENT. 0.5 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL GOVERN THE WORK. 0.6 NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THEE SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. 0.7 INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 1 GENERAL REQUIREMENTS 1.1 WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. 1.2 THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE AND 'FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING, AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR - REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. 1.3 CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISDNG ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. 1.4 SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR :THE FOLLOWING ITEMS: .1 METAL FABRICATIONS. .2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. .3 DOORS, FRAMES AND HARDWARE. .4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6' ACOUSTICAL PANEL ). .5 VCT FLOORING AND BASE ( COLOR SAMPLES ). .6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ). .7 PAINT ( 6' X 6' ON ACTUAL SURFACE ). .8 WALLCOVERINGS ( 9' X 9' DYE LOT CUTTING ). .9 SIGNAGE ( SAMPLE SIGN ). .10 LIGHT FIXTURES ( CATALOG CUTS ). 1.5 TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, TEMPORARY ENCLOSURES, FIRE PROTECTION, HEAT AND POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S AGENT 1.6 THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT ADDITIONAL CHARGE TO THE PARTY AFFECTED. 1.7 THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTIVE DEVICES AND ALARMS TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. 1.8 SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBMIT THE FOLLOWING INFORMATION: .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. .2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. .3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO ACCOMMODATE THE SUBSTITUTION. .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL AFFECT THE CONTRACT SUM AND CONTRACT TIME. 1.9 STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. 1.10 THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS. 1.11 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 1.12 PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. 2 DEMOLITION 2.1 COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW WORK. 2.2 WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. 2.3 WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL BE INCLUDED. 2.4 REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE DRAWINGS. 2.5 ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS TWD METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW FINISHES. 2.6 EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR NOTED TO BE REPAIRED. 2.7 SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. 2.8 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK IN SCOPE OF CONTRACT. 2.9 PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. 2.10 CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE - OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO DEMOLITION OPERATIONS. UTILITY SERVICE SHAH BE DEFINED AS PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS. CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A RECORD SEPIA TO SERVE AS PART OF THE "AS -BUILT' SET. 2.11 PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. 5 METAL FABRICATIONS 5.1 PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS REQUIRED TO COMPLETE WORK. 6 WOOD AND PLASTIC 6.1 CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE "CONSTRUCTION GRADE' LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE CONTENT. 6.2 PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32'. 6.3 FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. 6.4 FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE" AWI STANDARDS. .1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR TO FABRICATION OF MULTIPLE UNITS. 6.5 COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS). .1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL SURFACES. .2 PROVIDE 2" DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE ELECTRICAL OR DATA OUTLET LOCATIONS. 6.6 CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 400B FOR PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. .1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: GP -50 (0.050' NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 (0.028' NOMINAL THICKNESS); EDGES: GP -28 (0.028" NOMINAL THICKNESS). .2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28. .3 CABINET HARDWARE SCHEDULE: .1 HINGES: FULLY CONCEALED, SELF-CLOSING "1000 SERIES' BY GRASS OR EQUAL. .2 PULLS: WIRE PROJECTING TYPE, DRILLING 4' ON CENTER, #4483 OR EQUAL AS MANUFACTURED BY STANLEY. .3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS MANUFACTURED BY STANLEY. .4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES WITH POSITIVE STOP AND LOCKOUT POSITION, WITH HEAVY-DUTY FULL EXTENSION; 11429 OR EQUAL AS MANUFACTURED BY KNAPE & VOGT. .5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT OR EQUAL. SUITE 585 NDIANAPOLIS, INDIANA 6.7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH 9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR 12 FURNISHINGS PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. PROTECT HARDWARE, PLATES AND SIMILAR TRIM.; AFTER PAINT IS DRY, 6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, REINSTALL SUCH ITEMS. 12.1 CASEWORK: WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHEb WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY .1 INTERIOR PAINT SCHEDULE: PROVIDE: THE FOLLOWING PAINT .1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE OPERATING FOR TEN DAYS. SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD FOLLOWING: 6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND FOR THE VARIOUS SUBSTRATES, AS INDICATED. .1 IMPERIAL CABINET CO., INC. STRAIGHT WITH NO DISTORTIONS. 1 .2 MERILLAT INDUSTRIES, INC. 1 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM 1. FERROUS METAL: .3 YORKTOWNE CABINETS f WIDTH NOT TO EXCEED 1/8 U.O.N. A. ACRYLIC SEMI -GLOSS ENAMEL -FINISH: 6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC 15/16 MECHANICAL AND ELECTRICAL OUTLETS. LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC 15/16.1 MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND HVAC) AND SEMI -GLOSS ENAMEL. ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED 4Y THE 7 JOINT SEALERS 2. NON-FERROUS METAL: RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS ' A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC 7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL AND FIXTURES: LATEX PRIMER. BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, .1 'DOW CORNING 786' DOW CORNING CORP. 2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND .2 "SCS 1702 SANliAR ; GENERAL ELECTRIC CO. SEMI -GLOSS FINISH ELECTRICAL SYSTEMS. .3 "863 1345 WHITE',- PECORA CORP. 3. FERROUS STRUCTURE: 15/16.2 GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF .4 "PROGLAZE WHITE',- TREMCO CORP. A. ACRYLIC DRY FOG FLAT FINISH: DESIGN/BUILD DRAWINGS FOR FIRE PROTECTION, MECHANICAL, AND .5 "OMNIPLUS"; SONNEBORN BUILDING PRODUCTS 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY: A REDUCIBLE ACRYLIC DRY FOG COATING CERTIFIED ENGINEER. 7.2 ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING 4. NON-FERROUS STRUCTURE: 15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S SURFACES: A. ACRYLIC DRY FOG FLAT FINISH: DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS .1 "CHEM -CALK 600"; BOSTIK CONSTRUCTION PRODUCTS DIV. 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) .2 AC -20"; PECORA CORP. REDUCIBLE ACRYLIC DRY FOG COATING. AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL .3 "SONOLAC'; SONNEBORN BUILDING PRODUCTS 8. WOOD: DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND .4 'TREMCO ACRYLIC LATEX 834'; TREMCO, INC. A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. 1. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX 15/16.4 SUBMIT FIRE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE 8 DOORS AND WINDOWS PRIMER -SEALER. OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT 2. FINISH: 2 COATS #83XX M!RROLAC-WB ACRYLIC SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS SEMI -GLOSS ENAMEL. COORDINATE WITH OTHER CEILING COMPONENTS. NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER. B. STAIN -VARNISH RUBBED FINISH: 15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED 1. FILLER: 1 COAT #4800 WONDER WOODSTAIN SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH. R (OPEN PASTE WOOD F ILLE (0 E GRAIN WOODS). ) OWNER'S AGENT. 8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH 2. STAIN: 1 COAT #96XX WONDER WOODSTAIN 15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED AND LOCKSETS. IALKYD STAIN. WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. , 8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 3. SEALER: 1 COAT #4900 WONDER WOODSEALER VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. QUICK DRY SEALER. EQUIPMENT. 4. FINISH: 2 COATS #4600 WONDER WOODSTAIN 15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL: BE 9 FINISHES ALKYD SATIN VARNISH. GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. 10. GYPSUM WALLBOARD: 15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. A. ACRYLIC LATEX SATIN ENAMEL FINISH: INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL 1. PRIMER: 1 COAT #50801 WONDER TONES LATEX COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND .1 INSTALL "ELIMINATOR' TYPE HEAD TRACK AT WALLS TERMINATING PRIMER -SEALER. TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE AT CEILING. USE PREFORMED OUTSIDE CORNERS. 2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC INSTALLATION SHALL OCCUR. LATEX SATIN ENAMEL. 15/16.9 DIMENSIONS, IF IDENTIFIED, ARE fO CENTERLINE OF OUTLET OR GANG OF 9.2 GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE 'X' TAPERED 13. PRECAST CONCRETE: A LATEX TEXTURE COATING -SAND FINISH (WET AREAS) OUTLETS, UNLESS OTHERWISE NOTED. EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES ANI} 15/16.10 ALL SWITCHES AND SWTTCHPLATES SHALL BE BUILDING STANDARD ' JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE 1. PRIMER: 1 COAT #1502 WGNDER-SHIELD ACRYLIC COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. LATEX HOUSE PAINT PRIMER. IVORY. 2. FINISH: 1 COAT #44101 DEV-VO-TEX LATEX 15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY .1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED TEXTURE COATING. SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH PROVIDING PROPER ACCESS TO RECEPTACLES. 4 MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA- 15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND 9.11 WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLEAN AND FOR SPECIFIC LOCATION. - FINISHING OF GYPSUM BOARD. WITHOUT WRINKLES, GAPS OR OVERLAPS. 15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET • LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO 9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM .1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT OBSERVE PRIOR TO ANY COMMENCEMENT OF 'ROUGH -IN' ' DAMAGED OR SOILED TILES. ACCEPTABLE. CONSTRUCTION. •2 SEAMS MUST BE AT LEAST 2' FROM INSIDE CORNERS AND 6' FROM , .1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS OUTSIDE CORNERS. IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL GN GENERAL NOTES REFLECTED CEILING PLAN SHALL GOVERN. 10 SPECIALTIES .2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS 10.1 FIRE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO UNLESS NOTED OTHERWISE. BUILDING STANDARD, PROVIDE A INDUSTRIES "AMBASSADOR" SERIES, PROCEEDING WITH CONSTRUCTION. SEMI RECESSED, DUO -PANEL, FIELD PAINTED. GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: 9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR CASED OPENING UNLESS NOTED OTHERWISE. A TO FINISHED FACE OF GYPSUM BOARD. B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. .1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET C. TO TOP OF FINISHED FLOORS. MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH D. TO BOTTOM OF FINISHED CEILINGS. CARPET. GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, 9.6 RESILIENT FLOORING: EXISTING CONSTRUCTION AND WALL TYPES. GNA TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED .1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS OTHERWISE. ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT GN.5 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER. SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, .2 BASE: AT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING WITH CONSTRUCTION. ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. 9.7 USE AN APPROVED CEMENTTTIOUS FILLER TO PATCH CRACKS, SMALL DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM OBSERVATION. SURFACE VARIATION OF %' IN 10 FEET, NON -CUMULATIVE. GN.7 FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4' IN 20'-0' NON- 9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. STANDARDS: GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO CLOSE -IN OF WALLS. FLAMMABILITY: ASTM 2859 GN.9 SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT SURFACE BURNING: ASTM E66 PERIMETER WITH ACOUSTICAL OR FIRE RATED SEALANT AS APPLICABLE. SMOKE DENSITY: ASTM PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. SOUND ABSORPTION: ASTM 0 PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED 1423 6E FADE RESISTANCE: AATCC 16E TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL STATIC RESISTANCE: AATCC 134 JUNCTION BOXES ARE NOT PERMITTED. WARRANTY: 10 YEARS GN.10 ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY CONTRACTOR. .1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. CITY OF CARMEL/CLAY TOWNSI-IIP Dept. of Community Services -- Building & Code Enforcement CARMEL. FIRE DEPARTMENT t One Civic Square I" Floor; Carmel, IN 46032 PLAN REVIEW PLAN AUTHENTICATION CERTIFICATIONS AND AGREEMENT As the authorized agent responsible for obtaining a permit or permits, I certify that these pl Zl are IDENTICAL to those released for construction by the Indiana Dept, of Fire & Buildin '�% Reviewed Services. I also understand that if it is determined that these plans are Receive��.G_------ _ P not identical, a STO WORK ORDER will be served, astequired under the O inances referenced below. Released_... Type () � �� T D 7� /�� Z , a �9T Q (1't(/ �C �1 City Permit.. . Authorized Signature Printed Name St. PerMiv 'Required under Chapter 7, Section 10 ofthe Carmel City Code, entitled "Building Code" and Section 29.4.2 and Section 29.4.3 entitled "Administration". Required by Carmel / Clay Township Zoning Ordinance, Section Reviewed BY 31.1 entitled "Violations and Penalties". r S: Permits /Forms /AuthentSticker1 1-01 Date Tit WQ CJ Z ZQ QO Z Lo Qac LL. 0Z Cj WQ 1�� Qp 2-13-02 CSO #21599 CONSTRUCTION NOTES DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE CONSTRUCTION PLAN SCALE: 1/8" = 1'-0" NORTH D -.O 0 R SCHEDULE cso 9 Infisriofs Landscape AfdAectune DOOR V HARDWARE i SIZE 0) • OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. 3" WOOD FRAME N m� OD STAINED (WS2) 3 2. SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION 0 = FRAME Z ►- (n ¢ w m Z DOOR WITH TEMPERED W , 3 BIRCH PRE— AND WALL TYPES. GLASS INSET, REFER TO DOOR SCHEDULE NOTE #3 Z FINISHED WALNUT C) __1 M g I 43 ►— �cnac�o Uj � I w �, co W M O 3. SAVE ALL REMOVED ITEMS FOR OWNER, PER OWNER'S U Iw- W F'- ¢ W i LEVER FP2 LEVER DIRECTION, UNLESS OTHERWISE SPECIFIED 3 ( 3 ( 3 ( 1 -j(navo 4. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF 3'-0" FULL HT 1 3/4" WD/GL D2 WOOD NEW FLOOR FINISHES AS SCHEDULED. ' 500OFFICE 501 OFFICE 3'-0" 5. ALL NEW DOORS TO BE HINGED 6" AWAY FROM WALL. WOOD D1 HM 5011 PS,S 502 6. PROVIDE CONCEALED WALL BLOCKING AS REQUIRED WHERE NEW FULL HT 1 3/4" 14'-7*IV- q* HM D1 L,S SHELVING, PLUMBING AND CASEWORK ARE NOTED. OFFICE 3'-0" FULL HT 1 3/4" WOOD D1 HM D1 PS,S - 501 CONFERENCE i 3'-0' FULL HT 7. ALL WALLS SHALL BE CHAULKED OFF FOR DESIGNER'S REVIEW D1 5A801 505 PS,S 505 TO NEW WALL CONSTRUCTION 3 FULL HT + P7 ` `•.`• FPI D1 8. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 506 RECEPTION 3'-0" FULL HT :3�::. WOOD D1 HM 18" CLEAR ON PULL SIDE OF DOOR UNLESS NOTED OTHERWISE • 500 1 FP4 ,:;::.: i 3 I TO MEET ADA CODE REGULATIONS. • 5A801 •, WORK oa 502 9. ALL NEW TRACK AND TRIM AT WALL/CEILING CONDITIONS SHALL MATCH FP6 EXISTING COLOR AND MATERIAL TO PROVIDE CONTINUOUS/CONSISTENT s .... .�'�. Ps 1 1 APPEARANCE THROUGHOUT CEILING. 502 :::: CLOSET i 10. BUILDING OWNER AND/OR G.C. TO PROVIDE MINISBLINDS AT ALL PERIMETER 506 WINDOWS. EXISTING MINIBLINDS TO BE RELOCATED ARE TO BE STORED •� DURING CONSTRUCTION PHASE, THEN CLEANED AND REINSTALL UPON 505 i COMPLETION OF CONSTRUCTION. 11. ALL NEW AND EXISTING FIRE EXTINGUISHER CABINETS TO BE PAINTED o -------------- TO MATCH ADJACENT WALL FINISH. LIFSAFETY CONTRACTOR TO VERIFY NEED FOR ANY ADDITIONAL FIRE EXTINGUISHER CABINET LOCATIONS. IF ADDITIONAL FIRE EXTINGUISHER CABINETS ARE REQUIRED, LOCATIONS OF MUST BE SUBMITTED TO CSO INTERIORS FOR LOCATION REVIEW FOR OFFICE 1 OFFICE �C AESTHETICS PURPOSES ONLY. 503 in 5c 5c CONSTRUCTION PLAN SCALE: 1/8" = 1'-0" NORTH D -.O 0 R SCHEDULE cso 9 Infisriofs Landscape AfdAectune DOOR FRAME HARDWARE REMARKS SIZE 0) • � 3" WOOD FRAME N m� OD STAINED (WS2) 3 w ¢ D V) 0 = FRAME Z ►- (n ¢ w m Z DOOR WITH TEMPERED W , 3 BIRCH PRE— = GLASS INSET, REFER TO DOOR SCHEDULE NOTE #3 Z FINISHED WALNUT C) __1 M g I 43 ►— �cnac�o Uj � I w �, co W M O Q U Iw- W F'- ¢ W II II II II 11 LEVER O Z LEVER �r = H HARDWARE W Z O W -j(navo 500 RECEPTION 3'-0" FULL HT 1 3/4" WD/GL D2 WOOD D2 L,S,CL,DB 501 OFFICE 3'-0" FULL HT 1 3/4" WOOD D1 HM D1 PS,S 502 WORK RM 3'-0" FULL HT 1 3/4" WOOD D1 HM D1 L,S 503 OFFICE 3'-0" FULL HT 1 3/4" WOOD D1 HM D1 PS,S 504 OFFICE 3'-0' FULL HT 1 3/4" WOOD D1 HM D1 PS,S 505 CONFERENCE 3'-0" FULL HT 1 3/4" WOOD D1 HM D1 PS,S 506 CLOSET 3'-0" FULL HT 1 3/4" WOOD D1 HM D1 PS,S D1 � DOOR ELEVATIONS SCALE: 1/4" = 1'-0" WALL LEGEND NOTE: ALL WALLS TO BE WALL TYPE (W1) UNLESS NOTED OTHERWISE EXISTING PARTITION TO REMAIN -77WX= NEW WALL CONSTRUCTION TO BE: 2-1/2" METAL STUDS @ 24" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING LINE. WX= NEW DEMISING WALL CONSTRUCTION TO BE: 2-1/2" METAL STUDS @ 24" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING LINE. PROVIDE 2 1/2" SOUND INSULATION IN WALL AND ON HORIZONTAL SURFACE ABOVE THE CEILING. INSULATION TO EXTEND 2'-0" IN BOTH DIRECTIONS FROM CENTER— LINE OF WALL. ® DENOTES AREA NOT IN CONTRACT DENOTES NEW MILLWORK 0 NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE. CONSTRUCTION PLAN NOTES 8 ALIGN FINISHED FACES. 9 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 1/5A201. FPS NEW RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION. PAINT TO MATCH ADJACENT WALL SURFACE. 6 PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED ICE MAKER/REFRIGERATOR. VERIFY EXACT LOCATION OF, ALL APPLIANCES, REQUIRING A WATER SOURCE. REFER TO PLUMBING: ISOMETRIC 3/5A201 AND ELEVATIONS ON SHEET 5A801. 9 PROVIDE COAT ROD AND SHELF, 1/3 TO BE AT AN ADA ACCESSIBLE HEIGHT; REFERENCE DETAIL 2/5A201 9COPIER PROVIDED AND INSTALLED BY TENANT. G.C.: TO PROVIDE POWER SOURCE 9 FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MANUF. MANUAL. REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER FP7 SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQ. WITH MANUF. MANUAL. �$ PROVIDE 3/4" x 6' x 4' FIRE RETARDANT PLYWOOD PHONE BOARD. TO BE HUNG BETWEEN STUDS INSIDE WALL, LENGTH FROM WALL TO DOOR FRAME AND 4' FROM CEILING. DRYWALL OVER FOR A CLEAN LOOK. DOOR SCHEDULE NOTES 1. ALL DOORS ARE TO BE NEW BIRCH MOHAWK DOORS, PREFINISHED MAHOGANY. 2. ALL DOOR FRAMES, EXCEPT ENTRY DOOR TO BE 2" TIMELY FRAMES, PREFINISHED LIGHT BEIGE (WE 508) 3. ENTRY WOOD DOOR FRAME TO BE STAINED TO MATCH BUILDING STANDARD MAHOGANY 4. PROVIDE NEW CHROME MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD WHERE NEEDED. 5. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 6. COORDINATE KEYING LOCKSETS WITH TENANT. 1 /2"HW, 1 /2 "CW, & 1-1/4"V TYPICAL WALL TYPE '— I PREFINISHED ALUMINUM RECEIVER 3/4" WHITE MELAMINE SHELF TRIM "GB350" — FASTEN AT WINDOW TYPICAL AT ALL EXTERIOR SILL & SET IN A CONTINUOUS BEAD OF WALLS 5/8" TYPE X G.W.B. ACOUSTICAL SEALANT. TRIM COLOR 3/4 HARDWOOD TRIM, FINISH BELOW EXISTING WINDOW SILL COVER TO MATCH BLDG. WINDOW MULLIONS. PAINTED (P1) I CONNECT MAINS LINE OF EXISTING WINDOW SILL COVER BELOW 3/4"D HARDWOOD END SUPPORTS (TYP. EACH END) 1-1/4" dia. CHROME ROD SINK I CD Ln NOTE: WHERE SPAN EXCEEDS 4'-0" A CENTER SUPPORT BRACKET IS TO BE USED METAL STUD CONTINUOUS BEAD OF ACOUSTICAL SEALANT WINDOW MULLION "1 DETAIL 5A201 J SCALE: NTS COAT ROD AND SHELF � SECTION 5A201 SCALE: 1/2"=1'-0° rLvInaINu 3� ISOMETRIC 5A201 J SCALE: NTS 2"W TO BUILDING DRAIN Duke P Y CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 cso 9 Infisriofs Landscape AfdAectune LOW &Mykv Six Parkwood Office 600 East 96th Street, Suite 550 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 0 0) • � 3" WOOD FRAME m� m� OD STAINED (WS2) 3 2" TIMELY D V) 0 = FRAME = 3' BIRCH STAINED Z DOOR WITH TEMPERED W , 3 BIRCH PRE— = GLASS INSET, REFER TO DOOR SCHEDULE NOTE #3 Z FINISHED WALNUT C) M g I 43 ►— MOHAWK DOOR Uj � I w �, " 1 4 TEMPERED Q GLASS SIDELITE o2 N U 0o N Lc) 0 o I LEVER o zo LEVER s W HARDWARE HARDWARE D1 � DOOR ELEVATIONS SCALE: 1/4" = 1'-0" WALL LEGEND NOTE: ALL WALLS TO BE WALL TYPE (W1) UNLESS NOTED OTHERWISE EXISTING PARTITION TO REMAIN -77WX= NEW WALL CONSTRUCTION TO BE: 2-1/2" METAL STUDS @ 24" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING LINE. WX= NEW DEMISING WALL CONSTRUCTION TO BE: 2-1/2" METAL STUDS @ 24" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING LINE. PROVIDE 2 1/2" SOUND INSULATION IN WALL AND ON HORIZONTAL SURFACE ABOVE THE CEILING. INSULATION TO EXTEND 2'-0" IN BOTH DIRECTIONS FROM CENTER— LINE OF WALL. ® DENOTES AREA NOT IN CONTRACT DENOTES NEW MILLWORK 0 NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE. CONSTRUCTION PLAN NOTES 8 ALIGN FINISHED FACES. 9 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 1/5A201. FPS NEW RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION. PAINT TO MATCH ADJACENT WALL SURFACE. 6 PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED ICE MAKER/REFRIGERATOR. VERIFY EXACT LOCATION OF, ALL APPLIANCES, REQUIRING A WATER SOURCE. REFER TO PLUMBING: ISOMETRIC 3/5A201 AND ELEVATIONS ON SHEET 5A801. 9 PROVIDE COAT ROD AND SHELF, 1/3 TO BE AT AN ADA ACCESSIBLE HEIGHT; REFERENCE DETAIL 2/5A201 9COPIER PROVIDED AND INSTALLED BY TENANT. G.C.: TO PROVIDE POWER SOURCE 9 FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MANUF. MANUAL. REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER FP7 SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQ. WITH MANUF. MANUAL. �$ PROVIDE 3/4" x 6' x 4' FIRE RETARDANT PLYWOOD PHONE BOARD. TO BE HUNG BETWEEN STUDS INSIDE WALL, LENGTH FROM WALL TO DOOR FRAME AND 4' FROM CEILING. DRYWALL OVER FOR A CLEAN LOOK. DOOR SCHEDULE NOTES 1. ALL DOORS ARE TO BE NEW BIRCH MOHAWK DOORS, PREFINISHED MAHOGANY. 2. ALL DOOR FRAMES, EXCEPT ENTRY DOOR TO BE 2" TIMELY FRAMES, PREFINISHED LIGHT BEIGE (WE 508) 3. ENTRY WOOD DOOR FRAME TO BE STAINED TO MATCH BUILDING STANDARD MAHOGANY 4. PROVIDE NEW CHROME MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD WHERE NEEDED. 5. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 6. COORDINATE KEYING LOCKSETS WITH TENANT. 1 /2"HW, 1 /2 "CW, & 1-1/4"V TYPICAL WALL TYPE '— I PREFINISHED ALUMINUM RECEIVER 3/4" WHITE MELAMINE SHELF TRIM "GB350" — FASTEN AT WINDOW TYPICAL AT ALL EXTERIOR SILL & SET IN A CONTINUOUS BEAD OF WALLS 5/8" TYPE X G.W.B. ACOUSTICAL SEALANT. TRIM COLOR 3/4 HARDWOOD TRIM, FINISH BELOW EXISTING WINDOW SILL COVER TO MATCH BLDG. WINDOW MULLIONS. PAINTED (P1) I CONNECT MAINS LINE OF EXISTING WINDOW SILL COVER BELOW 3/4"D HARDWOOD END SUPPORTS (TYP. EACH END) 1-1/4" dia. CHROME ROD SINK I CD Ln NOTE: WHERE SPAN EXCEEDS 4'-0" A CENTER SUPPORT BRACKET IS TO BE USED METAL STUD CONTINUOUS BEAD OF ACOUSTICAL SEALANT WINDOW MULLION "1 DETAIL 5A201 J SCALE: NTS COAT ROD AND SHELF � SECTION 5A201 SCALE: 1/2"=1'-0° rLvInaINu 3� ISOMETRIC 5A201 J SCALE: NTS 2"W TO BUILDING DRAIN Duke P Y CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 cso 9 Infisriofs Landscape AfdAectune LOW &Mykv Six Parkwood Office 600 East 96th Street, Suite 550 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 0 0) � N h m� m� OD vN 3 D V) 0 V 0 L U Z a W j U °- Z Z Q o Q D zCA U Lc) Z co o z � YV) WWDI.. < Z O 0 Q =X Z _ 0aQ L � Q z Z W O_ ~ Q 0 W Certified By: Drawing Number: 5A201 Of Sheets Duke Job Number: A/E Job Number: 21599S REFLECTED CEILING .PLAN ' SCALE: 1/8" = 1'-0" NORTH REELECTED CEILING PLAN NOTES 1 . MECHANICAL AND ELECTRICAL IS DESIGN—BUILD. DESIGN—BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN—BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. 2. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFEiY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR ASTHETIC REVIEW ONLY. 3. CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND CONDITION. 4. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. 5. CEILING HEIGHT IS 9'-0" A.F.F. UNLESS OTHERWISE NOTED. 6. IN LOCATIONS OF (2) TWO OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLODATED TO A GANG PLATE CONDITION. 7. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. ELECTRICAL PLAN SCALE: 1/8" = 1'-0" NORTH :LECTRI CAL NOTES E.C. TO COORDINATE ELECTRICAL REQUIREMENTS FOR SPECIAL EQUIPMENT WITH TENANT. E.C. TO PROVIDE JUNCTION BOXES AT TELEPHONE AND COMPUTER LOCATIONS AS INDICATED ON PLANS, COMPLETE TELEPHONE AND COMPUTER SYSTEMS (MATERIAL & LABOR) ARE PROVIDED BY TENANT UNLESS OTHERWISE INDICATED. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. E.C. TO INSURE DEDICATED OUTLET TYPES TO BE COMPATIBLE WITH EQUIPMENT WALL MOUNTED OUTLETS TO BE MOUNTED 0 18" A.F.F. UNLESS OTHERWISE NOTED. :LECTRI CAL PLAN NOTES PROVIDE POWER FOR COPIER. E.C. TO VERIFY POWER REQUIREMENTS. PROVIDE DEDICATED OUTLETS FOR TENANT SERVER, PHONE BD, COPIER & SECURITY SYSTEM PROVIDE BOX WITH PULL STRING FOR TENANT PROVIDED SECURITY SYSTEM LECTRICAL LEGEND �ABOL DESCRIPTION NEW DUPLEX WALL OUTLET �D NEW DEDICATED CIRCUIT OUTLET �GFI NEW GROUND FAULT INTERUPT CIRCUIT OUTLET NEW CORE DRILL FLUSH FLOOR MOUNTED QUADROPLEX AND DATA OUTLET 7 NEW PHONE/DATA WALL OUTLET (BOX AND PULL STRING) CEILING LEGEND NEW 2' X 4' FLOURESCENT FIXTURE, BUILDING STANDARD SPECIFICATION. NEW INCANDESCENT DOWNLIGHT FIXTURE, IK - BUILDING STANDARD SPEC. O NEW INCANDESCENT WALL WASHER FIXTURE, a --+— BUILDING STANDARD SPEC. 1 NEW CLILING MTD. EXIT LIGHT W/ DIRECTION INDICATION DUAL—LITE, BUILDING STANDARD SPECIFICATION NEW 2 X 2 LAY—IN GRID SUSPENSION SYSTEM TWO WAY SWITCH TO NEW DIMMER SWITCH NL NIGHTLI�HT LOCATION Ue REALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 cso Ar�ecbrre Erqkwwing kdwk rle landempe Arnhi wwre lend &vveyng Six Parkwood Office 600 East 96th Street, Suite 550 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®cc'PYright 2001 c 0 LD 0 0 • r m0 m� �OD d Im (n O (n i CD Q) U Z Q J a. W U J Q Z 0 Q Q D z U cl) L0 0 o W Z 00 o z LU Y(n pa WW -1 C) -Q. V Q = X Z Z Un d J o W W z U Q Q W W J LL W Certified By: Drawing Number: 5A202 Of Sheets Duke Job Number: A Job Number: 21599S I`co I N FINISH PLAN NOTES FINISH LEGEND 1. ALL DOORS TO BE PREFINISHED BIRCH MOHAWK DOORS WITH MOHAGANY STAIN. FLOORCOVERINGS WALLCOVERING 2. ALL DOOR FRAMES TO BE PREFINISHED TIMELY; HOLLOW METAL, LIGHT BEIGE. MFG: MDC, LEN-TEX ' 3. ALL WOOD TRIM TO BE FINISHED TO MATCH NEW DOORS.C1 CARPET - DIRECT GLUE W1 PATTERN: CORONADO LX 4. PROVIDE MINIBLINDS TO MATCH BUILDING STANDARD MINIBLINDS , AT ALL O MFG: SHAW COMMERCIAL COLOR: RAFFIA 3610 -CR PATTERN: MOVEMENT 50875 TYPE II PERIMETER AND INTERIOR WINDOWS. COLOR: PERSIAN 75580 5. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK, TO CARPET - DIRECT GLUE O MFG: D.L. COUCH, VIN L FAB ANDARCHITECT/OR DESIGNER FOR REVIEW AND APPROVAL, BEFORE C2 W2 PATTERN: PARCHMENT FINISHES BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS. D MFG: PATCRAFT COMMERCIAL COLOR: A04-581 SENATE SAGE TT PATTERN: ALL THAT JAll 30oz TYPE I WS1 6. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING COLOR: NEW WAVE 21592 OFFICE ; TRANSITIONS TO BE FEATHERED AS REQUIRED TO PROVIDE A SMOOTH 501 O TRANSITION FROM FINISH TO FINISH PAINT W2 ' vCT1 VINYL- COMPOSITION TILE I 7. G.C. TO SUBMIT LAYOUT DIAGRAMS, OF ALL NEW CARPETS IN PROJECT MFG: MANNINGTON MFG: ICI W1 SERFS: ESSENTIALS SCOPE FOR REVIEW AND APPROVAL BY ARHITECT AND/OR DESIGNER COLOR: SUDAN SAND 631 C2 Bt ' ' BEFORE PROCEEDING WITH FLOORING FINISH INSTALLATION. P1 C1 CONFERENCE 8. G.C. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE COLOR: 143 FLAX FINISH: EGGSHELL B1 505 WHERE CARPET AND VINYL TILE TRANSITIONS TAKE PLACE. PATTERN: RANDOM 70% "'rfCT1 W1 PLASTIC LAMINATE RECEPTION vcT2 I Pit VCT2 VINYL COMPOSITION TILE 5 C1 MFG: MANNINGTON i PL1 MANUFACTURER: NEVAMAR 00 I ORK RM Oj a I Bt i SERIES: DESIGNER ESSENTIALS COLOR: PURE SPUN YARN YSN-002T 502COLOR: 255 FROSTED JADE FINISH: TEXTURED P1 P B1 I P1 B1 PATTERN: RANDOM 30% C1 — — — _j CLO T BASE WOOD FINISH 506 i B1 VINYL, BASE -4" COVE BASE i URER: JOHNSONITE W000 STAIN AND SPECIES TO MATCH MANUFACT C1 W1 Bt i COLOR: T MOON ROCK WS1 MOHAWK PREFINISHED MOHAGANY DOORS O i FINISH PLAN SCALE: 1 /8"-1'-0" 1PPER CABINETS TO BE 'IMBERIE; FAIRFIELD, TOFFEE VITH 4' CHROME WIRE PULLS tND (2) ADJUSTABLE SHELVES 5" dX1-1 2" PLASTIC AMINATE (PL1) COUNTER 11TH 4" BACKSPLASH. N 1"-1 I e - N LOWER CABINETS TO BE TIMBERLAKE; FAIRFIELD, TOFFEE WITH 4" CHROME WIRE PULLS AND (2) ADJUSTABLE SHELVES AND NO DRAWERS b M BLOCKING IN WALL AS REQ'D 4" VINYL BASE (B1) CASEWORK 6 SECTION �10 SCALE: 1/2"=1'-0" N N OFFICE OFFICE 503 504 W2 9 G)(B I (Da NORTH UPPER CABINETS TO BE riMBERLAKE; BAINBRIDGE, WHITE WITH 4" CHROME WIRE PULLS 4ND (2) ADJUSTABLE SHELVES 2_5" dX1-1/2" PLASTIC -AMINATE (PL1) COUNTER NITH 4" BACKSPLASH. LOWER CABINETS TO BE _ TIMBERLAKE; BAINBRIDGE, WHITE C _ WITH 4" CHROME WIRE PULLS AND (2) ADJUSTABLE SHELVES o AND NO DRAWERS BLOCKING IN WALL AS REQ'D 4" VINYL BASE (B1) CASEWORK_ 5 SECTION 5A801 SCALE: 1/2"=1'-0" M UPPER CABINETS TO BE TIMBERLAKE; BAINBRIDGE, WHITE WITH 4" CHROME WIRE PULLS AND (2) ADJUSTABLE SHELVES 25" dX 1-1 /2" PLASTIC LAMINATE (L1) COUNTER WITH 4" BACKSPLASH. STAINLESS STEEL DOUBLE BOWL SINK WITH PADDLE HANDLE HARDWARE � ' �, �3/4" PLAS. LAM. (PL1) X i' REMOVABLE PANEL 6" w iv N J VINYL BASE ADA SINK 4 SECTION 5A$O1 SCALE: 1/2"=1'-0" 6 r"eRn1 '3 ELEVATION 5A801 J SCALE. 1 /2"-1'-O" UPPER CABINETS TO BE TIMBERLAKE; FAIRFIELD, TOFFEE WITH (2) ADJ SHELVES 25"DX1-1/2" PLASTIC LAMINATE (PL1) COUNTER WITH 4 BACKSPLASH. , LOWER CABINETS TO BE TIMBERLAKE; FAIRFIELD, TOFFEE WITH (2) ADJ SHELVES NOTE: FILLER PANELS AS REQUIRED " VINYL BASE t 4 5 5A801 5A801 t UPPER CABINETS TO BE TIMBERLAKE; BAINBRIDGE WHITE WITH 4" CHROME WIRE PULLS AND (2) ADJUSTABLE SHELVES I N 25" dX1-1 /2" PLASTIC LAMINATE (PL1) COUNTER WITH 4" BACKSPLASH. I cv LOWER CABINETS TO BE TIMBERLAKE; BAINBRIDGE, WHITE WITH 4" CHROME WIRE PULLS AND (1) ADJUSTABLE SHELF NOTE: FILLER PANELS AS REQUIRED o 4" VINYL BASE M NOTE: SINK TO BE DOUBLE BOWL STAINLESS STEEL WITH PADDLE 3'-O" 2'-O" HANDLE FAUCET. ADA ACCESSIBLE SLANTED REMOVEABLE WORKR M PLASTIC LAMINATE PANEL WITH 3/4" 1 L E VA T I O N PLASTIC LAMINATE (PL1) END PANELS E 5A801 SCALE: 1/2"=1'-0" r5 2,-6•• 2' WORK RM 2 ELEVATION 5A801 SCALE: 1/2"=1'-0" UPPER CABINE S TO BE TIMBERLAKE; BAINBRIDGE W ITE WITH 4" CHROME WIRE PULLS AND (2 ADJUSTABLE SHELVES 25" dX 1-1 /2" PLASTIC LAMINATE (PL1) COUNTER WITH 4" BACKSPLASH. LOWER CABINE S TO BE TIMBERLAKE; BAINBRIDGE, W ITE WITH 4" CHROME WIRE PULLS AND (1) ADJUSTABLE SHELF 2" FILLER PANELS AS NEEDED 7I Duke REALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 CPO Ardibicture Engneeiing Interiors Larsdmmpe Architecture LOW &rveying Six Parkwood Office 0 I N o L 317.848.7800 FAX 317.574.0957 ®Copyright 2001 C 0 Q) st 0 cq t CO r o� �� d gn (n d M L O i U Z Q W .j U Z � _ j Z W W ca U) o o 3'-0" CONFERENCE RM '3 ELEVATION 5A801 J SCALE. 1 /2"-1'-O" UPPER CABINETS TO BE TIMBERLAKE; FAIRFIELD, TOFFEE WITH (2) ADJ SHELVES 25"DX1-1/2" PLASTIC LAMINATE (PL1) COUNTER WITH 4 BACKSPLASH. , LOWER CABINETS TO BE TIMBERLAKE; FAIRFIELD, TOFFEE WITH (2) ADJ SHELVES NOTE: FILLER PANELS AS REQUIRED " VINYL BASE t 4 5 5A801 5A801 t UPPER CABINETS TO BE TIMBERLAKE; BAINBRIDGE WHITE WITH 4" CHROME WIRE PULLS AND (2) ADJUSTABLE SHELVES I N 25" dX1-1 /2" PLASTIC LAMINATE (PL1) COUNTER WITH 4" BACKSPLASH. I cv LOWER CABINETS TO BE TIMBERLAKE; BAINBRIDGE, WHITE WITH 4" CHROME WIRE PULLS AND (1) ADJUSTABLE SHELF NOTE: FILLER PANELS AS REQUIRED o 4" VINYL BASE M NOTE: SINK TO BE DOUBLE BOWL STAINLESS STEEL WITH PADDLE 3'-O" 2'-O" HANDLE FAUCET. ADA ACCESSIBLE SLANTED REMOVEABLE WORKR M PLASTIC LAMINATE PANEL WITH 3/4" 1 L E VA T I O N PLASTIC LAMINATE (PL1) END PANELS E 5A801 SCALE: 1/2"=1'-0" r5 2,-6•• 2' WORK RM 2 ELEVATION 5A801 SCALE: 1/2"=1'-0" UPPER CABINE S TO BE TIMBERLAKE; BAINBRIDGE W ITE WITH 4" CHROME WIRE PULLS AND (2 ADJUSTABLE SHELVES 25" dX 1-1 /2" PLASTIC LAMINATE (PL1) COUNTER WITH 4" BACKSPLASH. LOWER CABINE S TO BE TIMBERLAKE; BAINBRIDGE, W ITE WITH 4" CHROME WIRE PULLS AND (1) ADJUSTABLE SHELF 2" FILLER PANELS AS NEEDED 7I Duke REALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 CPO Ardibicture Engneeiing Interiors Larsdmmpe Architecture LOW &rveying Six Parkwood Office 600 East 96th Street, Suite 550 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 C 0 Q) st 0 cq t CO r o� �� d gn (n d M L O i U Z Q W .j U UPPER CABINETS TO BE TIMBERLAKE; BAINBRIDGE WHITE WITH 4" CHROME WIRE PULLS AND (2) ADJUSTABLE SHELVES I N 25" dX1-1 /2" PLASTIC LAMINATE (PL1) COUNTER WITH 4" BACKSPLASH. I cv LOWER CABINETS TO BE TIMBERLAKE; BAINBRIDGE, WHITE WITH 4" CHROME WIRE PULLS AND (1) ADJUSTABLE SHELF NOTE: FILLER PANELS AS REQUIRED o 4" VINYL BASE M NOTE: SINK TO BE DOUBLE BOWL STAINLESS STEEL WITH PADDLE 3'-O" 2'-O" HANDLE FAUCET. ADA ACCESSIBLE SLANTED REMOVEABLE WORKR M PLASTIC LAMINATE PANEL WITH 3/4" 1 L E VA T I O N PLASTIC LAMINATE (PL1) END PANELS E 5A801 SCALE: 1/2"=1'-0" r5 2,-6•• 2' WORK RM 2 ELEVATION 5A801 SCALE: 1/2"=1'-0" UPPER CABINE S TO BE TIMBERLAKE; BAINBRIDGE W ITE WITH 4" CHROME WIRE PULLS AND (2 ADJUSTABLE SHELVES 25" dX 1-1 /2" PLASTIC LAMINATE (PL1) COUNTER WITH 4" BACKSPLASH. LOWER CABINE S TO BE TIMBERLAKE; BAINBRIDGE, W ITE WITH 4" CHROME WIRE PULLS AND (1) ADJUSTABLE SHELF 2" FILLER PANELS AS NEEDED 7I Duke REALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 CPO Ardibicture Engneeiing Interiors Larsdmmpe Architecture LOW &rveying Six Parkwood Office 600 East 96th Street, Suite 550 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 C 0 Q) st 0 cq t CO r o� �� d gn (n d M L O i U Z Q W .j U Z � j Z W W ca U) o o in Z o00— Z 06 Y v WofJ CO) IX ~ 0-cl- 0 D X Q LL Q 0 z W W "j a W Z LL Certified By: Drawing Number: 5A8O1 Of Sheets Duke Job Number: A/E Job Number: 215995 1901 CFM - � 31� i P 1401 -019 2-13-02 F17.11i ROOR'.".4,,VAC. I.. II' �I�I� III ,. .,ilII .. . I,. ��6. IIP d' IL.I SCALE: 1/8"=l'-0" GENERAL NOTES., 1.ALL DUCT GALVANIZED CONSTRUCTION 2.ALL NEW DUCT, FLEX,DIFFUSERS,GRILLES AND REGISTERS 3.TOILET EXHAUST AND OUTSIDE AIR, PROVIDED BY SHELL HVAC CONTRACTOR. KEY PLAN NORM NO SCALE