HomeMy WebLinkAboutCJ181033.0135BFIELD DENSITY TEST REPORT
Report Number:
Service Date:
Report Date:
Task:
CJ181033.0135B
09/20/18
09/26/18
7770 W New York St
Indianapolis, IN 46214-2988
317-273-1690
Client
Gibraltar Construction Corp
Attn: Douglas Perry
2932 N Webster Ave
Indianapolis, IN 46219
West Park: The Groves
3030 West 116th St.
Carmel, IN 46032
Project
Project Number: CJ181033
Lab Test Data
(%)
Compaction
Project Requirements
(%)
Content
Water
No.
Mat.
Material Information
Density
Max. Lab
(%)
Content
Water
Optimum
Ref. No.
Proctor Laboratory
Classification and Description (pcf)Test Method
1 132.59.5CJ181033.0065 No. 53 Stone
Field Test Data
No.Test Location Elev.No.
Test Lift /Mat.Depth Density
Probe Wet
Content
Water
(%)
Content
Water
Density
Dry
(%)
Percent
Compaction
(in)(pcf)(pcf)(pcf)
Backfill bridge and stem wall panels
1 North side 15' East of West 8"1 6"144.3 12.3 9.3 132.0 99.6
" "
2 North side 20' West of East 8"1 6"143.6 11.7 8.9 131.9 99.5
" "
3 South side 10' West of East 8"1 6"142.9 11.2 8.5 131.7 99.4
" "
4 South side 5' East of West 8"1 6"143.8 12.0 9.1 131.8 99.5
" "
5 North side 10' West of East 8"1 6"142.4 10.9 8.3 131.5 99.2
" "
6 South side 35' East of West 8"1 6"143.7 11.6 8.8 132.1 99.7
Comments:
Datum:
Last Cal. Date:Model:Make:S/N:
Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Services:
Reported To:
Contractor:
Ron Hueston with Gibraltar Construction
Jeremy Clem
Project Manager
Report Distribution:
(1) Gibraltar Construction Corp, Douglas Perry (1) City of Carmel IN, Mike Sheeks
(1) Johnson Wilbur Adams, Inc., Michael Wilbur (1) Smith Group JJR, Jessie Fink
Reviewed By:
Earth Exploration, Inc. Rep.: Jamie Conwell
ASTM D6938Test Methods:
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CR0007, 11-16-12, Rev.7 Page 1 of 1