Loading...
HomeMy WebLinkAbouta0014'-3 3/8"7" 2'-3 1/8" 9'-10 1/4" 2'-11"3'-0"1'-7"1'-5" 2'-6 5/16" 2'-6"3"1'-4 15/16" 7'-0 3/4" 4'-0 1/2" 3'-8 1/2"7'-1 1/2"4"3'-3"2'-0" 6"3'-6 1/4" 2'-9 3/4" 3'-6 1/4" 3 1/2" 3 5/16" 2'-4 3/8"3 5/16"2'-8 5/8"2'-6" 4'-9 1/2" 4'-6 1/2"10 1/2"5'-7"1'-6 1/2" 10 1/2" TUB SET AT 30° ANGLE        SOLATUBE PROVIDE SOLID BRIDGING, MECHANICALLY FASTENED W/ APPROVED JOIST HANGERS, NOT LESS THAN 16" O.C. BELOW ALL NEW WALLS (TYP) CONSTRUCTION PLAN A-1 Adam Gibson and Adam Gibson Design, LLC does not represent or imply itself to be or employ licensed architects or engineers. Adam Gibson and Adam Gibson Design, LLC assume no responsibility for structural or dimensional errors or omissions. Owner is responsible to verify and check all notes, details, elevations, sections and floor plans for any errors or omissions prior to start of construction. No warranties are expressed or implied including compliance of this plan with applicable building codes. Owner is responsible to assure that the building meets or exceeds local codes and regulations. It is the responsibility of Owner to obtain any and all structural analysis, engineering and specifications that may be required in the municipality in which it is to be built. The selection and application of correct structural materials is the responsibility of Owner. It is suggested that owner hire a general contractor to monitor and comply with the responsibilities listed within this paragraph. In no event shall Adam Gibson or Adam Gibson Design, LLC be responsible for project budgeting or bidding of third parties based on Designer’s plans. In the event that any liability is imposed on Adam Gibson or Adam Gibson Design, LLC, Adam Gibson’s or Adam Gibson Design, LLC’s liability to Owner or any third party shall not exceed the price paid for the construction drawings. ½" = 1' U.N.O. TABLE OF CONTENTS SHEET CONTENT COMMENTS A-1 FLOOR PLAN & GEN NOTES RENDERINGS FOR ARTISTIC USE ONLY A-2 CABINET & SOFFIT PLAN A-3 ELEVATIONS A-4 ELEVATIONS & DEMO PLAN A-5 ELECTRICAL & LIGHTING PLAN SHEET: SCALE: ABBREVIATIONS ABB = ABBREVIATION AFF = ABOVE FINISHED FLOOR APPX = APPROXIMATELY ATT = ATTACHED BLDG = BUILDING BLK – BLOCK BOT = BOTTOM BRK = BRICK C = CENTER CAB = CABINET CANT = CANTILEVERED CEM = CEMENT CF = CUBIC FOOT CH = CEILING HEIGHT CIR = CIRCLE CL = CENTER LINE CLG = CEILING CM = CENTIMETER CMU = CONCRETE MASONRY UNIT CO = COMPANY CONC = CONCRETE CONF = CONFERENCE CONT = CONTINUOUS CONV = CONVENTIONAL CONST = CONSTRUCTION CT = CERAMIC TILE CU YD = CUBIC YARD D.R. = DINING ROOM DEC = DECORATIVE DED = DEDICATED DEG = DEGREE DEMO = DEMOLISH DES = DESIGN(ED) DIA = DIAMETER DIM = DIMENSION DW = DISHWASHER EA = EACH ELCT = ELECTRICAL EMER = EMERGENCY ENCL = ENCLOSURE ENG = ENGINEER(ED) EQ = EQUAL EQUIV = EQUIVALENT ETR = EXISTING TO REMAIN EXC = EXCAVATE EXG = EXISTING EXT = EXTERIOR FAB = FABRICATED FAC = FACILITATE FDN = FOUNDATION FF = FINISHED FLOOR FIN = FINISH FSD = FORMED STEEL DECKING FT = FOOT FTG = FOOTING GL = GLULAM BEAM GAL = GALLON GALV = GALVANIZED GC = GENERAL CONTRACTOR GFCI = GROUND FAULT CIRCUIT INTERRUPTER GFI = GROUND FAULT CIRCUIT INTERRUPTER GLS = GLASS GWB = GYPSUM WALL BOARD HC = HOLLOW CORE HD = HEAVY DUTY HGT = HEIGHT HOR = HORIZONTALLY ID = INSIDE DIAMETER INSUL = INSULATION INT = INTERIOR J BOX = JUNCTION BOX JST = JOIST KIT = KITCHEN LAM = LAMINATE LEV = LEVEL LF = LINEAR FOOT LGT = LIGHTING LH = LEFT HAND LV = LOW VOLTAGE MAT = MATERIALS MAX = MAXIMUM MECH = MECHANICAL MIN = MINIMUM MIR = MIRROR N = NORTH N/A = NOT APPLICABLE NEC = NECESSARY NOM = NOMINAL NTS = NOT TO SCALE OC = ON CENTER OD = OUTSIDE DIAMETER OH = OVERHEAD OPP = OPPOSITE PER = PERIMETER PTD = PAINTED REC = RECESSED RECP = RECEPTACLE REF = REFLECTED REM = REMOVE REP = REPLACE REQ = REQUIRED RET = RETURN REV = REVERSE RH = RIGHT HAND RM = ROOM RO = ROUGH OPENING S = STEPPED FOOTING SC = SOLID CORE SCH = SCHEDULE SF = SQUARE FOOT SIM = SIMILAR SQ = SQUARE SS = STAINLESS STEEL STL = STEEL SUB = SUBSTITUTE SUF = SURFACE SW = SWITCH SYS = SYSTEM T&G = TONGUE AND GROOVE T/O = TEAR OUT TBD = TO BE DETERMINED TBR = TO BE REMOVED TEL = TELEPHONE TEMP = TEMPORARY TYP = TYPICAL U.N.O. = UNLESS NOTED OTHERWISE UTIL = UTILITY W.C. = WATER CLOSET (TOILET) W/ = WITH W/D = WASHER AND DRYER W/O = WITHOUT DESIGNED FOR:M ARY JO AND STEVE W EDDING 5033 ST CHARLES PLACE CARM EL, IN 46033GENERAL NOTES: 1) THIS PLAN SET IS PRINTED IN COLOR. IF THIS SET DOES NOT SHOW COLOR YOU MAY BE MISSING IMPORTANT INFORMATION. 2) CONTRACTOR SHALL NOTIFY DESIGNER PRIOR TO MAKING ANY MODIFICATIONS TO THESE PLANS. TO REQUEST CLARIFICATION FROM DESIGNER VIA PHONE OR EMAIL, SEE SIDEBAR FOR CONTACT INFO. 3) DO NOT SCALE DRAWINGS. USE MARKED DIMENSIONS. 4) ALL RENDERINGS ARE FOR ARTISTIC DEPICTION. PLAN UPDATES MAY NOT BE REFLECTED IN RENDERINGS. RENDERINGS SHALL NOT BE USED FOR CONSTRUCTION. 5) CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE A COPY OF THESE PLAN AND ACCOMPANYING SPECIFICATIONS TO EACH EMPLOYEE OR SUBCONTRACTOR WHO MAKES DECISIONS REGARDING THE PROJECT AND ARE ENCOURAGED TO ACTUALLY READ THEM. 6) THE SPECIFICATIONS AND DRAWINGS ARE MINIMUM STANDARDS THAT SHOULD ADD TO AND EXCEED THOSE OF LOCAL BUILDING CODES, BUT THEY DO NOT REPLACE LOCAL BUILDING CODES, AND ARE NOT CONSIDERED EXHAUSTIVE. LOCAL BUILDING CODES SHALL BE OBSERVED OR EXCEEDED IN ALL CIRCUMSTANCES. 7) IN THE EVENT OF A CONFLICT BETWEEN THE SPECIFICATIONS AND DRAWINGS WITH LOCAL BUILDING CODES, THE LOCAL BUILDING CODES SHALL PREVAIL UNLESS THESE SPECIFICATIONS EXCEED THOSE OF THE LOCAL CODES. IF THIS OCCURS, CONTRACTOR SHALL NOTIFY DESIGNER PRIOR TO COMMENCEMENT OF ANY WORK RELATING TO THE CONFLICT. 8) CONTRACTOR SHALL BE RESPONSIBLE TO FIELD-VERIFY ALL SITE CONDITIONS AND MEASUREMENTS. 9) DIMENSIONS ARE TO FRAMING U.N.O. EXCEPT WINDOW AND DOOR OPENINGS WHICH ARE TO THEIR FRAMES (ALLOW FOR ROUGH OPENINGS). 10) CABINET DIMENSIONS ARE TO DRWYALL. 11) CABINET DIMENSIONS ARE INDICATED IN INCHES. 12) ALL OTHER DIMENSIONS ARE INDICATED IN FEET/INCHES. 13) ALL SOLID BACKSPLASHES AND CURBS SHALL HAVE A THICKNESS OF 2CM OR LESS. IN NO EVENT SHALL A 3CM PIECE OF COUNTERTOP BE APPLIED AS BACKSPLASH.ADAM G IBSO N DESIG N, LLC200 S. RANG ELIN E RD. SUITE 223CARM EL, IN 46032317.255.5001ADAM @ADAM G IBSO N.CO MDESIGNED BY:Wedding Master 13-X10 DATE: 11/10/2017 09/21/18 Mike Sheeks